Vive DMD1029WHT User manual

HIGH
NORMAL
CHANGING THE DATE AND TIME
• With the device turned off, press the “ ” button to display the
settings menu.
• On the screen, you will see “YR” and a number blinking underneath. Select
the current year by pressing the “ ” button to increase the year.
• Once the year has been selected press the “ ” button to conrm
the selection.
• The month will blink next. Press the “ ” button to select up and press “ ”
to set the month.
• The day will blink next. Press the “ ” button to select up and press “ ” to
set the day.
• The hour will blink next. Press the “ ” button to select up and press “ ” to
move on.
• The minute blink next. Press the “ ” button to select up and press “ ” to
move on.
• The device is now ready to be used.
• Press the “ ” button to exit settings screen.
ACCESSING PREVIOUS AND AVERAGE MEASUREMENTS
• While the unit is off, press the “ ” button.
• The rst reading displayed will be the average of all of the saved history. You
will see the “Average” icon displayed on the screen.
• Press the “ ” button to toggle up and the “ ” button to toggle down.
• Press the “ ” button to exit reading history.
CLEARING DEVICE MEMORY
• While the unit is off, press the “ ” button and the “ ” button simultaneously.
USER INFORMATION
Tips for Measurement
It can cause inaccuracy if the measurement is taken in the
following circumstances.
1. Within 1 hour after eating or drinking.
2. Within 20 minutes after taking a shower/bath.
3. In a very cold environment.
4. Immediate measurement after tea, coffee, or smoking.
5. When talking or moving your ngers.
6. When you need to urinate.
Maintenance
In order to get the best performance, please follow the instructions below.
WARNING
If you have any problems with this device, such as setting up, maintaining or
by yourself. Please report to vivehealth.com. if any unexpected operations or
events occur. Please use a soft cloth to clean the whole unit. Don’t use any
abrasive or volatile cleaners.
ABOUT BLOOD PRESSURE
What is systolic pressure and diastolic pressure?
When ventricles contract and pump blood out of the heart, the blood pressure
reaches its maximum value in the cycle, which is called systolic pressure. When
the ventricles relax, the blood pressure reaches its minimum value in the cycle,
which is called diastolic pressure.
What is the standard blood pressure classification?
The chart below is the standard blood pressure classication
published by American Heart Association (AHA).
AHA Home Guideline for Upper Limit of Normal BP
We recommend you seek medical advice. Please note that the device does not
replace a cardiac examination, but serves to detect pulse irregularities at an
early stage.
Why does my blood pressure fluctuate throughout the day?
1. Individual blood pressure can change on a daily basis. It is also affected
by the way you apply the cuff and the measurement position. Please take
measurements using the same method to ensure accuracy.
2. The variations in the pressure can be greater or smaller, depending on the
actual medicine taken.
3. Waiting at least 3 minutes for another measurement.
Why do I have different readings when I take my blood pressure at
the doctor’s office and my home?
Blood pressure can uctuate over a period of 24 hours based on: weather,
emotions, exercise, stress, etc.
When you take your blood pressure at home, make sure to pay close attention
to the following:
• If the cuff is secured properly.
• If the cuff is too tight or too loose.
• If the cuff is secured on the upper arm.
• If you feel anxious.
You had better take 2-3 deep breaths. Advice: Wait at least 4-5 minutes until you
calm down.
Can you take measurement from both arms?
You may choose to measure both arms and then average the two readings to
get your blood pressure result. The norm is to measure the left arm closest to your
heart. For accuracy use the same method each time.
IRREGULAR HEARTBEAT INDICATOR
1. Your digital blood pressure monitor features an Irregular Heartbeat
Detector. Irregular Heartbeats may inuence the results of the
measurement. If the monitor detects the Irregular Heartbeats during
measurement, the symbol “ ” will appear on the display with the
measurement values. You can take another measurement to make sure the
values are not inuenced by moving during measurement or
Irregular Heartbeat.
2. If this symbol appears frequently, we recommend you consult your physician.
3. This device does not replace a cardiac examination, but serves to detect
pulse irregularities at an early stage.
HYPERTENSION INDICATOR
This unit features our unique Hypertension Indicator. The World Health
Organization has established globally accepted standards for assessment of
high or low blood pressure readings. The below chart should be considered only
as a guideline, always consult with your physician or health care professional to
interpret your individual results.
WHAT’S INCLUDED
• Automatic Wrist Blood Pressure Monitor
• 2 AAA Batteries
• User Manual
QUICK START GUIDE
1. Insert the batteries
2. Wrap the cuff around the wrist with the
palm facing upwards and leaving a half
to one inch gap between the bottom
of the palm and the cuff.
3. Keep your arm still and position your
wrist at the same level as your heart.
4. Press the “ ” button to initiate measurement. The device will beep and
begin inating.
5. The device will beep when measurement is complete (about 30 seconds).
6. The measurement will show on the screen, including systolic, diastolic,
and pulse.
UNDERSTANDING YOUR READINGS
Palm Up
Position
the cuff
SYS < 120mm Hg
DIA < 80mm Hg
press
artery vein
blood discharging
Systolic
relax
blood entering
Diastolic
Indicates Systolic
Rate
Indicates Diastolic
Reading
Indicates Pulse Rate
Irregular Heartbeat
Indicator
Hypertension Indicator
indicates high or low
blood pressure
HIGH
NORMAL

Probable CauseProblem Recommended Action
Batteries are drained. Replace all batteries with new ones .
Replace all batteries with new ones .
Replace all batteries with new ones .
Warm up the batteries, or use the
device in a warmer setting.
Adjust patient and wrist cuff
to measure.
Relax, and try to take a
measure again.
Rest a while, relax and
measure again.
Check that the wrist cuff is
fastened properly and retake
the measurement.
Refrain from moving
during measurement.
Do not take measurements after
exercise or coming back from
the outdoors.
Push the power button again,
and then begin measure again.
Use Alkaline batteries and replace
all batteries at the same time
with same brand batteries.
Reinsert batteries in the
correct position .
Batteries are drained.
Batteries are drained.
Perhaps the cuff was
improperly positioned .
Blood pressure naturally varies
throughout the da y.
Bodily movement during device use.
The wrist cuff is not fastened properly .
It could be a normal action if the
user’s blood pressure is higher than
the initial pressure value, the device
automatically pumps to a higher
pressure by 40mmHg each time.
Measurement shortly after exercise
or exposure to the outdoors.
System design.
In colder temperatures batteries
have weaker electrical charges.
Different battery brands have
different life spans.
Batteries are not correctly
aligned with terminals.
Low Battery
Symbol appears.
Nothing appears in
the display even
when the power is
turned on.
Suspicious heart
rate results,
Suspicious blood
pressure results,
No reading after
measurement.
Power switches off
automatically.
Device operation
time is inconsistent.
During measuring,
air reinflates.
© Copyright and Distributed by Vive Health
8955 Fontana Del Sol Way, Naples, FL 34109
All Rights Reserved. Made in China.
Email: [email protected]
ERROR CODES
TROUBLESHOOTING
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
SPECIFICATIONS
• 2 AAA batteries required (Included)
• Screen Size: 3cm x 3.8 cm (1.18” x 1.5”)
• Weight: 120g (excluding battery)
• Provides Systolic and Diastolic Pressure readings
• Memory: Records 60 measurements
• Shows average measurement on bottom left
• Adjustable Cuff range: 12.5cm - 21cm (4.9” - 8.3”)
• Secure using velcro
• Measurement Range:
• Pressure: 30 - 280 mmHg Pulse
• Pulse: 40 - 199 / minute
• Calibration Accuracy:
• Pressure: +-3mmgh
• Pulse: +- 4% of reading
WARNING
• This device is intended for adult indoor use only,
• This device is intended for non-invasive measuring and monitoring of arterial
blood pressure. It is not intended for use on extremities other than the arm or
for functions other than obtaining a blood pressure measurement.
• Do not confuse self-monitoring with self-diagnosis. This unit allows you to
monitor your blood pressure. Do not begin or end medical treatment.
Consult your physician for treatment or advice.
• If you are taking medication, consult your physician to determine the
most appropriate time to measure your blood pressure. Never change a
prescribed medication without consulting your physician.
• If the cuff pressure exceeds 40kPa (300 mmHg), the unit will automatically
deate. Should the cuff not deate when pressure exceeds 40 kPa (300
mmHg), detach the cuff from the arm and press the START/STOP button to
stop ination.
• To avoid measurement errors, carefully read this manual before using
the product.
• The equipment is not AP/APG equipment and not suitable for use in the
presence of a ammable anesthetic mixture with air of with oxygen or
nitrous oxide.
• The operator shall not touch output of batteries and the patient simultaneously.
• To avoid measurement errors, please avoid the condition of strong
electromagnetic eld radiated interference signal or electrical fast transient/
burst signal when using the AC adapter.
• The user must check that the equipment functions safely and see that it is in
proper working condition before being used.
• Please use ACCESSORIES and detachable parts specied/ authorized by
MANUFACTURE. Otherwise, it may cause damage to the unit or danger to the
user/ patients.
• Manufacturer will make available on request circuit diagrams, component
parts list, etc.
• This unit is not suitable for continuous monitoring during medical emergencies
or operations. Otherwise, the patient’s arm and ngers will become
anesthetic, swollen and even purple due to a lack of blood.
• Please use the device under the environment which was provided in the
user manual. Otherwise, the performance and lifetime of the device will be
impacted and reduced.
• During using, the patient will contact with the cuff. The materials of the cuff
have been tested and found to comply with requirements of ISO 10993-
5:2009 and ISO 10993-10:2010. It will not cause any potential allergic
reaction or contact injury.
• The device doesn’t need to be calibrated in two years of reliable service.
• Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT
according to the local guidelines.
• When the device was used to measure patients who have common
arrhythmias such as atrial or ventricular premature beats or arterial
brillation, the best result may occur deviation. Please consult your physician
about the result.
• The device is contraindicated for any female subject who may be
suspected of, or is pregnant. Besides provided inaccurate readings, the
effects of this device on the fetus are unknown.
• When using this device, please pay attention to the following situation which
may interrupt blood ow and inuence blood circulation of the patient, thus
cause harmful injury to the patient: Too frequent and consecutive multiple
measurements; The application of the cuff and its pressurization on any arm
where intra-vascular access or therapy, or an arteriovenous (A-V) shunt, is
present; Inating the cuff on the arm on the side of a mastectomy.
• Do not apply the cuff over a wound, otherwise it can cause further injury.
• Don’t kink the connection tube, otherwise, the cuff pressure may continuously
increase which can prevent blood ow and result in harmful injury to
the PATIENT.
• The patient is an intended operator. The patient can measure under normal
circumstances and maintain the device and its accessories according to the
user manual.
• The blood pressure monitor, and the cuff are suitable for use within the
patient environment. If you are allergic to dacron or plastic, please don’t use
this device.
• Please keep the unit out of reach of infants, children or pets, since inhalation
or swallowing of small parts is dangerous or even fatal.
• The device is not suitable for public use.
• The device is not intended for PATIENT transport outside a healthcare facility.
• The device cannot be used with HF surgical equipment at the same time.
EMC GUIDANCE
1. MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and
needs to be installed and put into service according to the EMC information
provided in the ACCOMPANYING DOCUMENTS
2. Wireless communications equipment such as wireless home network devices,
mobile phones, cordless telephones and their base stations, walkie-talkies can
affect this equipment and should be kept at least a distance d=3, 3m away from
the equipment.
(Note: As indicated in Table 6 of IEC 60601-1-2:2007 for ME EQUIPMENT, a typical
cell phone with a maximum output power of 2 W yields d=3, 3m at an IMMUNITY
LEVEL of 3V/m)
GUARANTEE REGISTRATION
You are protected by Vive Health’s industry leading guarantees
and customer service:
If you did not purchase through vivehealth.com, please register at vivehealth.
com/register to validate your guarantee.
Product Code: DMD1029WHT
HIGH
NORMAL
110
1201 30 1401 60 180
Systolic Blood Pressure
Optimal
Normal
High-Normal
Mild Hypertension (Grade 1)
Moderate Hypertension (Grade 2)
Severe Hypertension (Grade 3)
Diastolic Blood Pressure
Hypertension Indicator
mmHg
mmHg
100
90
85
80
HIGH
NORMAL
HIGH
NORMAL
HIGH
NORMAL
HIGH
NORMAL
HIGH
NORMAL
2 YEAR GUARANTEE
Err Cod Meaning
No Pulse or detected pulse not strong.
Leakage in Cuff Pressure/Inflation too lo w.
Pressure fault.
Deflation fault.
Memory Error.
Corrective Action
Err 0
Err 2
Err 3
Err
Err 1
Take off heavy clothes and try again.
The wrist cuff is not fastened properly . Re-apply
the cuff, and take measurement again.
Take off batteries to reboot the device, then
take another measurement .
Low Battery. Replace all batteries with new ones.
Rest a while, relax and try again.
The wrist cuff is not fastened properly . Re-apply
the cuff and take measurement again.