1
Congratulations
Congratulations on your new Viverity®TrúEase Electric Breast Pump! The Viverity®TrúEase Electric Breast Pump is
perfect for many occasions.
● Collecting breast milk while you're away from your baby
○ for example: when you're at work
● Relieving engorgement
○ for example: when your baby's feeding habits change because they're eating more solids
● Maintaining your milk supply if you have to temporarily stop breastfeeding
○ for example: to express unsuitable milk while you are undergoing medical treatment
The Viverity ®TrúEase Electric Breast Pump provides many of the features busy moms love.
● 4 speed modes and 7 levels of suction
● Milk back-ow protection
● Quiet motor for discretion
● Small and lightweight
● 2 power options to t your needs
○ AC/DC Adapter
○ 4 AA Alkaline batteries (not included)
Indication for Use
The Viverity ®TrúEase Electric Breast Pump is a single user, electrical powered device used to express milk from the
breasts of lactating women. This device is not intended for hospital use.

2
Table of Contents
Congratulations ............................................................................................................................ 1
Indication for Use ......................................................................................................................... 1
Important Safeguards .................................................................................................................. 4
● DANGER ..................................................................................................................................... 4
● CAUTION ..................................................................................................................................... 4
● WARNING .................................................................................................................................... 4
Parts Guide .................................................................................................................................. 6
● Electrical Pump Main Unit .................................................................................................................. 7
● Expression Collection Combo Kit .......................................................................................................... 8
How to Assemble the Expression Collection Kit .......................................................................... 9
How to Assemble Electric-Pump Diaphragm Kit ........................................................................ 12
How to Assemble Expression Collection Combo Kit .................................................................. 13
Power Options............................................................................................................................ 15
● Using your AC/DC Adapter (included) .................................................................................................. 15
● Using 4 AA Alkaline Batteries (Batteries not included) ................................................................................ 16
● Install the Batteries (AA Alkaline) ........................................................................................................ 17
Pumping Instructions ................................................................................................................. 19
Cleaning Instructions ................................................................................................................. 22
● Sanitize Prior to First Use ................................................................................................................ 22
● Before Each Use ........................................................................................................................... 22
● General Cleaning Instructions ........................................................................................................... 22
● Tubing Cleaning Instructions ............................................................................................................. 23
Breastmilk Storage Guidelines .................................................................................................. 24
● Important Notes ............................................................................................................................ 24

3
Tips ............................................................................................................................................ 26
● Pumping Tips ............................................................................................................................... 26
● Breastfeeding Tips ........................................................................................................................ 27
Troubleshooting ......................................................................................................................... 28
● Interruption of Electrical Service ......................................................................................................... 28
● Radio Frequency Energy ................................................................................................................. 28
● Decreased Suction ........................................................................................................................ 28
● Breastmilk Buildup in the Breastshield Body ........................................................................................... 29
● Where to get Replacement Parts ........................................................................................................ 29
● Where to get Additional Accessories .................................................................................................... 29
● What Additional Accessories are Available ............................................................................................. 29
Technical Data ........................................................................................................................... 30
● Power Requirements ...................................................................................................................... 30
Warranty .................................................................................................................................... 31

4
Important Safeguards
The Viverity ®TrúEase Electric Breast Pump is designed for a single user and should never be
shared or resold; doing so will void the warranty.
READ ALL INSTRUCTIONS BEFORE USING
DANGER: To reduce the risk of electrocution:
● Always unplug this product immediately after using.
● Do not use while bathing.
● Do not place or store this product where it can fall or be pulled into a tub or sink.
● Do not place or drop into water or other liquid.
● Do not reach for an electrical product that has fallen into water. Unplug immediately.
CAUTION:
● Do not use this product for any other purpose than as indicated in the Instructions and Assembly.
● Make sure all the parts are assembled correctly before operating.
● Stop using the breast pump immediately if your breasts or nipples experience any discomfort.
● Please wash hands before using this product.
● Keep this product out of reach of babies and children.
● Do not drop or hit the product to avoid damage.
● Do not touch the product with bare hands right after sterilizing by boiling water to avoid scalds and burns.
● Do not over-boil to avoid premature aging of the product materials.
WARNING: To reduce the risk of burns, electrocution, re, or injury to persons:
● This product should never be left unattended when plugged in.
● Close supervision is necessary when this product is used near children or invalids.
● Use this product only for its intended use as described in this manual. Do not use attachments or parts not recommended by
Viverity ®.
● Do not operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged,
or if it has been dropped in water.
● Keep the cord away from heated surfaces.
● Do not use while sleeping or drowsy.
● Do not drop or insert any object into any opening or tubing.
● Do not use outdoors with the AC/DC Adapter or operate where aerosol spray products are being used, or where oxygen is
being administered.

Important Safeguards (Continued)
● Make sure the voltage of the AC/DC Adapter is compatible with the power source.
● Plug the AC/DC Adapter into the electrical outlet rst, then plug the Power Cord into your Viverity ®Electric Breast
Pump.
● Viverity has provided an AC/DC Adapter with this device. Using any other AC/DC Adapter pack not approved by the
manufacturer voids the warranty.
● If you are infected with Hepatitis A, Hepatitis B, or have HIV (Human Immunodeciency Virus): pumping breast milk does not
reduce or remove the risk of transmitting the virus to your baby through breast milk.
● Wash the Expression Collection Combo Kit parts before each use.
● Do not operate a motor vehicle while using the Viverity ®Electric Breast Pump.
● Do not attempt to modify the product.
SAVE THESE INSTRUCTIONS along with your receipt for future reference.
5

Parts Guide
AC/DC Adapter
Bottle Adapter Kit
Breast Pump Main Unit
6
Expression Collection Combo Kit
Vacuum Tubing with Adapter
Spare Parts
(1 Valve and 2 O-Ring)

● Electrical Pump Main Unit
Parts Guide
Vacuum Adjusting Wheel
Expression Button
Battery Cover
Tubing Adapter Inlet
AC/DC Adapter Inlet
TOP VIEW BOTTOM VIEW
T1 T2 T3 T4
LED Screen
7
Power Button

● Expression Collection Combo Kit
Parts Guide
8
Cap
Diaphragm
Cup with O-Ring
Breastshield Body
One-Way Valve
Bottle Adapter
Collection Bottle
Bottle Base
Silicone Cushion
Electric-pump
Diaphragm Kit
Expression
Collection Kit

How to Assemble the Expression Collection Kit
Your Viverity ® Electric Breast Pump comes pre-assembled; however, you will need to re-assemble it after each cleaning
(For cleaning instructions, see page 22). Below is a step-by-step guide for assembling the Expression Collection Kit:
1. Hold the "horn" of the Breastshield Body in one hand. Make sure the bottle-thread side opening is facing up.
2. With the thumb and forenger of the other hand, hold the tip of the One-Way Valve and place the at circular bottom into the opening.
Be sure not to stretch, bend, or twist the tip of the One-Way Valve. Seal all the edges rmly.
Note: The One-Way Valve tip does not have to align with anything, as long as all the edges are securely sealed.
Flat Circular Bottom
Tip
9

How to Assemble the Expression Collection Kit (Continued)
3. With your thumb and forenger, gently seal any openings on the tip of the One-Way Valve and shape into a straight line.
Note: This is critical to the performance of the pump.
4. Carefully twist on the Bottle Adapter to the Breastshield Body for a secure t.
Note: Be sure not to bump the One-Way Valve when twisting the Breastshield Body and the Bottle Adapter pieces together. If you
bump the One-Way Valve, repeat step 3.
10

How to Assemble the Expression Collection Kit (Continued)
5. With the Bottle Adapter in one hand, twist on the Collection Bottle for a secure t.
11

How to Assemble Electric-pump Diaphragm Kit
1. With the Cup in one hand, place the Diaphragm in the Cup (matching the shape of the Cup). Press around the edges of the
Diaphragm for a secure t. Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them.
2. Place the Cap on the Cup & Diaphragm. (Be sure to align the hinge and hinge cover.) Press tightly to seal.
Hinge cover
Hinge
12

1. With the O-Ring side down, put the Electric Pump Diaphragm Kit into the top of the Breastshield Body opening. Twist the Electric-
Pump Diaphragm Kit clockwise into the Breastshield Body until it locks into place.
2. Take the open-end of Vacuum Tubing (the end without the adapter) and connect to the Tubing Connector located on the cap. Push
together rmly for a tight seal.
Note: Make sure there is no moisture in the Tubing.
How to Assemble the Expression Collection Combo Kit
Turn
Clockwise
13
Tubing
Connector

How to Assemble the Expression Collection Combo Kit (Continued)
14
3. With the Breastshield Body in one hand, place the Silicone Cushion in the Breastshield Body (matching the shape of the horn).
Secure the lip of the Cushion around the edges of the horn.
Note: Your Electric Breast Pump will work with or without the Silicone Cushion. Your comfort depends on your preference.
4. Make sure the Tubing Connector is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit.

Power Options
1. Plug the AC/DC Adapter into an electrical outlet.
2. Attach the Power Cord to the AC/DC Adapter inlet on the Electric Pump Main Unit.
Your Electric Breast Pump may be operated under any of the following power supply modes:
Using your AC/DC Adapter (included):
● Electrical safety can only be achieved when using the AC/DC Adapter which was provided with the pump. Use of
any another adapters causes concern for the safety of the product and/or the user and voids the warranty.
15

● Always replace all 4 AA Batteries at the same time.
● Remove all batteries from the Electric Pump Main Unit if the Pump is not going to be used for extended periods
of time.
● Properly dispose of all batteries, according to government regulations for environmental protection and recycling.
Note: Alkaline Batteries may present a risk of re or chemical burn if mistreated. Do NOT disassemble any battery.
Do NOT place batteries near heat source or re. Dispose of used batteries properly. Do NOT dispose of
batteries in re. Keep away from children.
AA Battery Compartment 4 AA Batteries
(not included)
Using 4 AA Alkaline Batteries (not included):
16

1. Open the battery cover.
2. Remove the old batteries if you are replacing them and properly dispose of them.
Install the Batteries (AA Alkaline):
17

Install the Batteries AA Alkaline (Continued):
3. Insert 4 new AA Alkaline Batteries.
Note: Make sure the polarity is correct as indicated.
4. Close the Battery Cover, making sure it "snaps" into place.