RT REVISIONS TABLE
Mod. PAGURO
6000/9000/14000/18000/
6
50
0/8500
Date: 12.03.2020_Rev: 0.0
1
REVISIONS TABLE
CHAPTER DESCRIPTION REVISION DATE
WA Warnings 0.0 12.03.2020
1 Technical specifications 0.0 12.03.2020
2 Operating conditions 0.0 12.03.2020
3 Operator 0.0 12.03.2020
4 Transport and handling 0.0 12.03.2020
5 Installation of the machine 0.0 12.03.2020
6 Installation errors 0.0 12.03.2020
7 Start and stop procedure 0.0 12.03.2020
8 Remote control panel 0.0 12.03.2020
9 General safety information 0.0 12.03.2020
10 Maintenance 0.0 12.03.2020
11 Types of risks and safety pictograms included 0.0 12.03.2020
12 Electrical drawings 0.0 12.03.2020

EC Declaration of Conformity (Annex IIA Machinery Directive 2006/42/EC)
The undersigned:
VTE S.r.l.
Via Luciano Lama, 5
33059 – Fiumicello Villa Vicentina (UD)
- Italy -
Declares that the machine called MARINE DIESEL GENERATOR of own production:
Model…………………..PAGURO XXXXX
Serial no.…...................XXXXXX
Year of construction...........2020
to which this declaration relates is in accordance with the following directives:
- Machinery Directive 2006/42/EC
- Low Voltage Directive 2014/35/UE
- Electromagnetic Compatibility Directive 2014/30/UE
and to the following harmonized standards:
- UNI EN ISO 12100:2010 “Machine safety – General design principles - Risk
assessment and risk reduction”
- CEI EN 60204-1 “Machine safety – Electric equipment of the
machines. Part 1: General rules”
We also declare the machine is CE marked
The person authorised to compile the Technical File:
VTE Srl
Via Luciano Lama, 5
33050 Udine (UD) - Italy
The legal representative:
____________________________
Fiumicello, GG.MM.2020 (Mr. Riccardo Snaidero)

IN INDEX
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date:
12.03.2020_Rev: 0.0
1
INDEX PAGE
WARNINGS
Premise….……………………………………………………………………………………….…. 1
Introduction……………………………………………………………………………………….… 1
Purpose and contents of the User and Maintenance Manual……………………………….... 1
General warnings….…………………………………………………………………………….…. 1
Terminology used in the User and Maintenance Manual……………………………………… 2
Obligation to keep the User and Maintenance Manual safe…..………………………….……. 3
Manufacturer Details……………………………………………………………………………….. 3
Technical Assistance……………………………………………………….………………………. 3
General safety notes………………………………………………………………………………… 3
Warranty………….………………………………………………………….………………………. 4
General safety warnings…………….…..………………………………………..……………….. 4
Operator instruction………………………………………………………………………………… 4
Work area……………………………………………………………………………………………. 4
Additional warnings…………………….…………………………………………………………… 5
Description of the generator..................................................................................................... 5
Operation principle………………………………………………………………………………….. 6
Protections of the generator…….……………………………………………………………………. 6
Explosive atmosphere…………….…………………………………………………………………. 7
Disposal of waste products…………..………………………….…….………………………….… 7
Demolition and disposal of the generator……....……...………………………………………….… 7
Disposal of harmful substances………...................................................................................... 7
1. TECHNICAL SPECIFICATIONS
1 Technical specifications….………………………………………………………………… 1
1.1 “CE” identification plate…………………………………………………………… 1
1.2 Technical specifications….……………………………………………………….. 1
1.3 Copyright…………………………………………………………………………… 4
2. OPERATING CONDITIONS
2 Operating conditions…….…………………………………………………….…..…….. 1
2.1 Containment compartment…………………………………………………….. 1
2.2 Minimum air change distance………………………………………………….. 1
2.3 Characteristics of the operating environment…...…………..……………….. 1
2.4 Lighting …………………………………………………………………………… 2
2.5 Vibration emission………………….…………..……………..………………… 2
2.6 Noise power emission….…………..……………..……………..……………… 4
3. OPERATOR
3 Operator….…………………..………………………..…………………………….…….. 1
3.1 Operator training…………….……………………………………..……………... 1
3.2 Clothing……..………………………………………………………..………….…. 1
3.3 Operator general tasks……..………………………………….……………………… 1
3.3.1 Installer………………………………………………………………………. 1

IN INDEX
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date:
12.03.2020_Rev: 0.0
2
PAGE
3.3.2 Qualified technician............................................................................. 1
3.4 Categories of operators authorised to work and intervene on the generator.... 1
3.4.1 Installers………………………………………………………………………. 1
3.4.2 Ordinary maintainers……………………………………………………... 2
3.4.3 Extraordinary maintainers…………………………….……………….… 2
3.5 Exposure to hazards and risks from materials…………………………………... 2
3.6 Operators training…………..………………….……….………………..………… 2
4. TRANSPORT AND HANDLING
4 Transport and handling………………………………………………………………………. 1
4.1 General notions……..…………………………………………………………….... 1
4.2 Transport and handling…………………………………………………………….. 2
4.2.1 Lifting and handling by crane or overhead crane………….…..……… 2
4.2.2 Lifting and handling with forklift………………………………………….. 4
4.3 Unpacking……………………………………………………………………….….. 5
4.4 Handling the unpacked generator……..……………………………………...…... 5
4.5 Storage…..……………………………………………………………………….…. 7
4.6 Shipping…..………………………………………………………………..……..… 7
4.7 Inspection on arrival…….………………………………………………………….. 7
5. INSTALLATION OF THE GENERATOR
5 Installation of the generator..………………………………………..……………….…….… 1
5.1 Set up for installation…………….……..………………………………….……..… 1
5.2 Fixing the generator…………………………………………………..……………… 1
5.3 Ventilation……………………………………………………………………….…… 2
5.4 External connections………………………………………………………………… 3
5.5 Exhaust system installation (on request)…………………………….……………. 4
5.5.1 Traditional system…………………………………………………………… 5
5.5.2 On-board system with space shortage………………………………….…. 6
5.5.3 On-board system with long exhaust line…………………………………... 7
5.6 Fuel line…………………..………………………………….………………….. 7
5.7 Installation of the cooling system……………………………………………..…..…. 9
5.7.1 Siphon-break valve…………………………………………………………. 10
5.7.2 Raw water intake (on request)…………………………………………..… 11
5.8 Electrical connection………………………………………………………………….. 11
5.8.1 Connection to starting battery…………………………….......................... 11
5.8.2 Main output voltage………………………….…………….….………. 12
5.8.3 Transfer switch over shore line/generator ……………………..….. 13
5.8.4 Remote control panel………………………………………………..... 14
5.9 Pre-start inspections………………………………………………………………….. 15
5.10 Testing.............................................................................................................. 15
6. INSTALLATION ERRORS
6 Installation errors……………………………………………………………………………… 1
6.1 Water intake…….…………………………………………………………….………… 1
6.2 Waterline…………………………………………………………………………….. 1

IN INDEX
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date:
12.03.2020_Rev: 0.0
3
PAGE
6.3 Exhaust line………………………………………………………..………………… 1
7. STARTING/STOPPING PROCEDURE
7 Starting/Stopping procedure……………………………………………………………….. 1
7.1 Checks to be carried out before starting……………….……………….…….….. 1
7.2 Startup procedure……………………………………………………………………. 1
7.3 Operating the generator…………………………………………………..……… 2
7.4.1 Check list……………………………………………………………………... 2
7.5 Stopping the generator………..……………………………………..……………… 3
8. REMOTE CONTROL PANEL
8 Remote control panel………………………………………………………………………… 1
8.1 Control panel description…….......................................................................... 1
8.2 Alarm management………………………………………………………………… 2
8.2.1 Reset alarms…………………………………………………………..…… 2
8.3 Electrical connections (8 wires blue cable / control panel)………….………….. 3
8.4 Automatic starting device (on request)………………………………………….…… 3
9. GENERAL SAFETY INFORMATION
9 General safety information…………..…….................................….………..………..….... 1
9.1 Preventing electric shock……………....................……………..……………..…… 1
9.2 Preventing fire…………………………………………………………….………..…. 1
9.3 Preventing explosions………………………………………………………………. 1
9.4 Accidental power on………………………………………………………………… 2
9.5 Explosion of batteries……………………………………………………………….. 2
9.6 Battery acid…………………………………………………………..……………… 2
9.7 High noise………………………………………………………………..………...… 2
10. MAINTENANCE PAGE
10 Maintenance.………………….…………………………………….…..……………….... 1
10.1 Cutting of the energy sources…..…..………………………….………………… 1
10.2 Ordinary maintenance...…..………………………….….…….…………………. 2
10.2.1 Maintenance state…………………………………………………….. 2
10.2.2 General safety warnings…………….…..……………………………….. 2
10.2.3 Functional checks on safety devices……………..…………………….. 3
10.2.4 Maintenance of the electrical system.………….…..………………….. 3
10.2.5 General advices……………………………….…..…………………….... 4
10.2.6 Maintenance plan…….………………………….…..……………………. 4
10.2.7 Ordinary maintenance table…..……………….…..………….…………. 4
10.3 Extraordinary maintenance.…..………………………….…………………..……. 6
10.4 Troubleshootings……………….……....…..…………….………………….…… 7
10.5 Maintenance procedures……………………………………………………………. 10
10.5.1 Replacing the sea water pump impeller............................................... 10
10.5.2 Cleaning the sea inlet filter…………………………………………..….. 11
10.5.3 Extraction of used engine oil…….…………………………………..….... 11
10.5.4 Checking engine oil………………………….……………………..……... 12

IN INDEX
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date:
12.03.2020_Rev: 0.0
4
PAGE
10.5.5 Filling engine oil………..…………………………………………………... 12
10.5.6 Cleaning of the heat exchanger tube and replacing cooling liquid………13
10.5.7 Generator cleaning……….………..……………….…..……………..….… 13
10.5.8 Maintenance of the batteries…………………………………………..…. 13
10.5.9 Endothermic engine maintenance………………………………………..…14
10.6 Generator inactivity…………………………………………………………………… 14
11. TYPES OF RISKS AND SAFETY PICTOGRAMS INCLUDED
11 Types of risks and safety pictograms included……………………………………….. 1
11.1 Risks of a mechanical nature...………….……………….…………………… 1
11.1.1 Generator stability……….………..……………….…..………………… 1
11.1.2 Breakage dangers during the functioning of the generator…………. 1
11.1.3 Dangers and risks caused by flying objects…………………………. 1
11.2 Design and physical features of safety guards…...….……………….………. 2
11.3 Safety pictograms on-board the generator………….….……………………….. 2
11.4 Electrical risks………….…………………..………….….……………………….. 2
11.5 Other nature risks or residual risks……..………….….……………………….. 3
11.5.1 Risk of fire………..….……..……………….……….…………………… 3
11.5.2 Risk of explosion…..….……..……………….…..…….……………….. 3
11.5.3 Dangers and risks from toxic exhaust gases……….…….……….…. 3
11.5.4 Dangers and risk arising from parts subject to extreme temperatures.. 3
12. ELECTRICAL DRAWINGS
12 Electrical drawings……………………………………..………………………………….. 1
12.1 Paguro 6000-9000 electrical drawing...……….………….………………… 1
12.2 Paguro 14000 - 18000 electrical drawing...…………………….…………… 2
12.3 Paguro 6500 electrical drawing...…………………….………………………. 3
12.4 Paguro 8500 electrical drawing...…………………….………………………. 4
12.5 Alternator electrical drawing Paguro 6000 - 9000...………….…………….. 5
12.6 Alternator electrical drawing Paguro 14000 - 18000….……………………. 6
12.7 Alternator electrical drawing Paguro 6500 - 8500…….……………………. 7
ATTACHMENTS
Attachments………………………………………………………………………………………………. 1

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
1
WARNINGS
PREMISE
This User and Maintenance Manual of the Marine Diesel Generator mod. Paguro
6000/9000/14000/18000/6500/8500 contains the instructions that allow the operator to use the generator to
the best of its operational capabilities and provides all necessary information and instructions to operate in
observance of the Machinery Directive 2006/42/EC.
Its accurate design eliminates or significantly reduces any risks to the user being the operator.
It is therefore possible to affirm that the Marine diesel generator is safe when used correctly.
The user is required to strictly follow the instructions provided herein and particularly those pertaining to safety
regulations.
A single copy of the User and Maintenance Manual is provided when the generator is delivered and installed.
If the operator is not able to keep the manual safe without ruining it, it is necessary to prepare a photocopied
copy of it. In any case it is possible to contact the Manufacturer to ask for another copy.
This manual is an integral part of the generator and must be kept safe along with the generator with the utmost
care and follow this last one in each and every eventual property steps.
The VTE S.r.l company will not be held liable for any inaccuracies in the instruction manual if due to printing
errors or inadvertent errors.
Furthermore, the VTE S.r.l company reserves the right to make modifications to their generators as it deems
necessary or useful without undermining the essential characteristics.
INTRODUCTION
Purpose and contents of the User and Maintenance Manual
This User and Maintenance Manual describes the Marine Diesel Generator mod. Paguro
6000/9000/14000/18000/6500/8500 for the production of electricity on board.
The generator can operate within the limits indicated in the cap. 1 "TECHNICAL SPECIFICATIONS”.
For an easy consultation of the manual, the Marine Diesel Generator will hereinafter simply be referred to as
the "generator". The manual is written to put operators in a position to:
– gain knowledge of issues relating to the generator.
– work safely.
The manual contains therein the user instructions and maintenance advice, together with rules on safety and
accident prevention.
General warnings
Before proceeding with the generator starting procedure the operator must read carefully this manual and must
have vested a deep knowledge of the technical specifications and of the generator commands.
They contain important information for:
– the safety of people involved in installation, start up and maintenance;
– the safety and efficiency of the generator;
Operation of the generator is not allowed if there is any doubt regarding the correct interpretation of the
instructions. Contact the Manufacturer or service centre if further explanation is required.
The Manufacturer is available to provide technical training at the Customer's facilities.
Requests, time, costs and arrangements must be agreed in advance.

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
2
Terminology used in the User and Maintenance Manual
- WORK AREA The operating area is defined as the area for the installation of the generator.
- INSTALLATION: Installation is defined as the mechanical and plant integration of the generator on the boat.
- COMMISSIONING: Commissioning is defined as the functional verification of the installed system.
- DEMOLITION AND DISPOSAL OF THE GENERATOR: Decommissioning is defined as the mechanical
removal of the generator. Disposal of the generator is defined as the activity of demolition and disposal of the
components that make up the generator.
- MAINTENANCE AND REPAIR: Maintenance and repair work is defined as the periodic inspection and/or
replacement of parts or components of the generator to identify the cause of a failure that has occurred, which
ends with the restoration of the functional conditions of the project.
- IMPROPER USE: Improper use is intended as the use of the generator outside the limits of the technical
documentation.
- DANGEROUS AREA: Any area inside and/or near the generator where a person is exposed to a risk to their
safety or health.
- EXPOSED PERSON: Any person who is wholly or partly in a hazardous area.
– OPERATOR: the person responsible for operating the generator each within the limits of the tasks assigned
to it.
– INSTALLER: the person responsible for performing mechanical and plant installation, calibration,
commissioning, each within the limits of the tasks assigned to it.
– QUALIFIED TECHNICIAN: a specialised person, employed by the Manufacturer or by the authorised service
centre, specifically trained and authorised to make interventions of extraordinary maintenance (of electric or
mechanical nature) or repairs which require a particular knowledge of the generator, their functioning, of the
safety devices provided and of its modes of intervention.
In the following manual will be defined the tasks, the skills and the work limitations of the various operators.
Installers must not perform operations reserved for maintenance technicians or qualified technicians.
The Manufacturer will not be held liable for damages arising from the failure of such prohibition.
Certain activities (such as installation and commissioning, initial calibration and registration, repair,
overhaul, moving and decommissioning of the generator) require the presence of qualified technicians
or the authorized service centre.
To understand the instructions (text and pictures), the generator operators must meet (or acquire, through
training and instruction) at least the following requisites:
– a sufficient level of general and technical knowledge to read and understand the content of those parts
of the manual that concern him/her, and to be able to interpret the drawings and diagrams correctly;
– ability to understand and interpret the symbols, safety pictograms;
– knowledge of the main accident prevention and technological regulations;
– Know what to do in an emergency, and how to use Personal Protective Equipment (PPE) correctly.
Maintenance technicians must possess the same requisites and also have a good level of technical knowledge
obtained by a professional qualification and/or adequate experience in their field of work.
They must also have the specific and specialized technical knowledge (mechanical, electrical) that are required
for the tasks proposed in the User and Maintenance Manual. Important! The MANUFACTURER must:
– verify that staff actually possess the required level of knowledge to read and fully understand the User
and Maintenance Manual.
– carry out practical training and ensure, even using tests, that the appointed operator is able to
operate the generator properly and safely.

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
3
Obligation to keep the User and Maintenance Manual safe
You must keep this manual and all attached documents in an easily accessible place, near the
generator, and known to all operators.
The operators and maintenance staff must be able to quickly locate and consult, in any situation, the User and
Maintenance Manual.
THE MANUAL IS AN INTEGRAL PART OF THE GENERATOR FOR SAFETY REASONS. Therefore:
– must be kept intact (in all its parts).
– must follow the generator in each and every eventual property passes until its demolition (even when
rented, etc.).
Manufacturer Details
VTE S.r.l.
Via Luciano Lama, 5
33059 Fiumicello – Villa Vicentina (UD) - Italy
Telephone: +39 0431 96488
E-Mail: info@volpitecno.com
Website: www.volpitecno.com
Technical Assistance
The Technical Assistance Service is available for Customers to:
– provide clarifications and information;
– planning possible interventions at the Customer's premises, by sending specialized technical staff;
– send spare parts/components.
Requests can be made directly to the Manufacturer, to the Official Distributor or the Authorized service point;
they can be forwarded by email. For any technical service or spare parts order, always quote the serial number
of the generator.
IMPORTANT!
– the Customer-installer is always required to buy either original parts or the ones authorized in
writing by the Manufacturer;
– the assembly and removal of parts must be entrusted and performed by qualified technicians,
and carried out in accordance with the Manufacturer's instructions;
– the use of non-original parts and/or defective or incorrect assembly relieve the Manufacturer
of any liability AND VOID THE WARRANTY.
General safety notes
VTE S.r.l. cannot be held responsible for injuries and damages of any kind to persons/things or other, caused
by the non-observance of the indications given in this document or by the improper use of the generator.
The modification/deletion of the apparatuses in the generator or the modification/deletion of the protections
and safety devices provided with the generator, built by VTE S.r.l., involve the immediate warranty loss.

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
4
Warranty
The company VTE S.r.l. guarantees the generator according to the terms and times provided on the sales
contract.
The warranty does not cover wear parts such as brass, gaskets, etc.
The warranty is void if the failure/damage to the generator is caused by incorrect installation,
tampering, unauthorized service or the use of non-genuine spare parts.
Company VTE S.r.l. has no other obligations or fulfilment than what above stated.
For any technical communication with VTE S.r.l., always use the contacts listed in this User and Maintenance
Manual.
GENERAL SAFETY WARNINGS
The purpose of this section is to inform operators (installers and maintainers) of any risks and dangers of
particular relevance and of general and specific precautions for their elimination or neutralisation.
This section contains information and instructions on:
– dangerous situations that may occur during installation and maintenance of the generator;
– guards and safety devices and their proper use;
– residual risks and procedures to adopt (general and specific precautions to eliminate or limit them).
For clarity of information, some illustrations in this manual show parts of the generator without
protection guards. NEVER USE THE GENERATOR WITHOUT PROTECTIONS.
Operator instruction
Installers and maintainers must be familiar with the following before operating on the generator:
– the function and use of the controls;
– the position, the function and the use of all safety devices;
– the characteristics of the generator;
– this manual and how to consult it.
They also must:
– have received adequate training.
– have received written permission to use the generator.
If these requirements are not observed the Manufacturer declines each responsibility.
Any tampering or unauthorized replacement of one or more parts of the generator, the use of accessories,
tools, consumables other than those prescribed by the Manufacturer, can result in the risk of injury and
accordingly relieves the Manufacturer of any civil or criminal liability.
Work area
– The work area must be NEVER occupied by boxes, generator tools, or other objects, which can create
obstruction resulting in failures. Nothing should interfere with the freedom of movement of the
operators; furthermore, in emergency situations, staff must have unrestricted and quick access to the
generator.
– Access to the work area is forbidden to people who are not directly involved in installation or
maintenance.
– The compartment in which the generator is installed must be kept clean and well ventilated.
It is responsibility of the operator to enforce the rules and to report any non-observance to those in charge.

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
5
ADDITIONAL WARNINGS
At this point in the User's and Maintenance Manual it is useful to provide a list of general safety requirements
for the most common operating situations:
– respect the indications of the safety pictograms on the generator board;
– before starting the generator, make sure that no one is performing maintenance on the generator.
– maintenance must be entrusted only to authorized personnel who must first put the generator in
maintenance status (see Chap. 10 “Maintenance”).
– under no circumstances should the guards (sound-absorbing enclosure) be removed while the
generator is running;
– it is absolutely forbidden to anyone to use the generator for a purpose other than the one expressly
intended.
Any other use of the generator not provided for in this operation and Maintenance Manual is
considered "IMPROPER USE".
In this case, the manufacturer declines all responsibility in relation to any damage caused to property
and/or persons and considers that any warranty on the generator and the accessories supplied has
lapsed.
DESCRIPTION OF THE GENERATOR
The Marine diesel generator mod. Paguro 6000/9000/14000/18000/6500/8500 is a generator designed to
produce electricity on board boats. This generator has been designed and built to be installed on a boat, (able
to house the generator in terms of size and weight).
The Paguro generator consists essentially of:
- Soundproofing capsule made of reinforced fiberglass with composite stratification and covering in
high-density sound-absorbing material for the reduction of the sound emission due to the internal
combustion engine;
- Double anti-vibration system, internal with 4 soft supports and external with 4 semi-elastic supports;
- Endothermic engine, powered by diesel, with 2/3/4 cylinders (depending on the model) and cooled by
means of a heat exchanger, whose purpose is to transform the energy of the input fuel into mechanical
energy (rotation of the shaft);
- Synchronous alternator, brushless and condenser regulation, water-cooled by an exchanger, driven
by the shaft of the endothermic engine, equipped with a battery charger for a dedicated starting battery.
The alternator converts mechanical energy into electrical energy;
- Electrical box equipped with alternator thermal protection reset button and capacitors;
- Heat exchanger provided with tube nest;
- Fresh water endothermic engine cooling system with heat exchanger;
- Self-priming water pump;
- Remote control panel with LCD display, for managing the operation of the generator;
- Manual engine oil extraction pump;
- Sea water and gas exhaust terminal with overtemperature switch.
The generator is easy to manage in maintenance and cleaning operations, according to the latest accident
prevention regulations.
The generator is supplied with a spare parts kit (impeller and impeller seal).

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
6
Operation principle
The operation of the generator, for the generation of energy, develops through the following phases:
1. The fuel arrives at the endothermic engine where, by means of the combustion process, it is
transformed into mechanical energy;
2. Mechanical energy is converted by the alternator into electrical energy;
3. The self-priming pump draws sea water for successive cooling of the following components:
Engine oil sump, via a contact exchanger;
Alternator;
Coolant contained in the engine cooling exchanger;
Exhaust terminal.
4. Exhaust gases and cooling water are expelled outside through the terminal.
PROTECTIONS OF THE GENERATOR
The generator is protected by a multilayer fiberglass capsule, lined internally with sound-absorbing material,
consisting of:
- N.1 lower containment element of the generator equipped with anti-vibration system.
- N.2 upper elements with interlocking profiles, held together by silicone elastic bands.
Lower protection of the generator
Lateral elastics Upper elastics
Lower
element
Upper
elements

WA WARNINGS
Mod. PAGURO
6000/9000/14000/18000/
6
500/8500
Date: 12.03.2020_Rev: 0.0
7
EXPLOSIVE ATMOSPHERE
This generator and its devices are made in standard version and can therefore not be installed and used in
premises where the concentration of dust may exceed acceptable limits and create potentially explosive
atmospheres.
DISPOSAL OF WASTE PRODUCTS
During normal operation, the generator generates waste or waste substances that must be collected, recycled
or disposed of in accordance with current laws in the country in which it is installed and used. These substances
are basically:
- engine oil;
- refrigerant liquid.
- exhausted lubrication oils;
- replaceable wearable parts.
To proceed with the disposal of these substances, please refer to the Regulations in the Country of residence
in accordance with the regulations in force and act accordingly.
DEMOLITION AND DISPOSAL OF THE GENERATOR
Once the generator has reached the end of its technical life, it must be put out of service so it will not be used
for the intended purpose and it is not possible to reuse parts and materials. The generator must be safely
disabled and demolished. VTE S.r.l. company assumes no liability for damages to things or people arising
from the reuse of individual parts of the generator for functions other than the original.
1. Before proceeding with demolition, it is necessary to empty the generator from all liquids;
2. Inform the responsible authorities for this task by written communication in accordance with the
regulations in force in the individual Country;
3. Dismount the generator depending on the various components, using tools and devices that can
normally be found in maintenance stores. Separate potentially hazardous components such as:
- Plastic materials, polymer-based materials, etc;
- Electrical components, cables, ecc…;
- Metal parts by type, such as aluminium, steel, etc…
4. After having received the authorization from the above authorities, proceed to the disposal of the
components in accordance with applicable laws and Regulations in this area.
Always keep in mind that the disposal of toxic and harmful waste is subject to special rules according to the
country of affiliation. Before doing such operations, you must be aware of these rules.
Disposal of harmful substances
To proceed with the disposal of these substances, please refer to the Regulations in the Country of residence
in accordance with the regulations in force and act accordingly.
Any irregularity committed by the Customer before, during or after the scrapping and disposal of the
generator components, in the interpretation and application of the relevant Regulations in this matter,
is solely responsible for the Customer himself.
If you have any questions or other information, please contact the technical assistance service of VTE S.r.l.

1 TECHNICAL SPECIFICATIONS
Mod. PAGURO
6000/9000/14000/18000/
6
50
0/8
5
00
Date: 12.03.2020_Rev: 0.0
1
1. TECHNICAL SPECIFICATIONS
1.1 “CE” IDENTIFICATION PLATE
The picture below illustrates the identification plate of the generator.
It is attached to the generator's capsule and shows:
- Manufacturer identification data;
- CE mark;
- Model;
- Type:
- Serial number;
- Year of construction.
The plate bears the CE symbol, certifying that the generator is compliant with the main health and work safety
regulations in the European Community as well as with Machinery Directive 2006/42/EC.
“CE” identification plate
1.2 TECHNICAL SPECIFICATIONS
In the following tables are listed the Generator technical characteristics in Your possession (please refer to the
individual model):
GENERATOR SPECIFICATIONS
DESCRIPTION U.M. PAGURO 6000 PAGURO 9000 PAGURO 14000 PAGURO 18000 PAGURO
6500
PAGURO 8500
Width (mm) 660 720 860 970 770 890
Depth (mm) 460 460 580 580 460 580
Height (mm) 600 620 650 650 620 650
Weight (incl.
capsule) (Kg) 130 160 210 230 170 200
Acoustic output DB(A) 52 52 54 54 49 49
Lombardini engine
model - LDW 502 M LDW 702 M LDW 1003 M LDW 1404 M LDW 1003 M LDW 1404 M
Number of
cylinders
- 2 2 3 4 3 4
Engine oil quantity (Kg) 1.5 1.5 2.4 3.2 2.4 3.2
MODEL
TYPE
SERIAL NUMBER
YEAR OF CONSTRUCTION

1 TECHNICAL SPECIFICATIONS
Mod. PAGURO
6000/9000/14000/18000/
6
50
0/8
5
00
Date: 12.03.2020_Rev: 0.0
2
GENERATOR SPECIFICATIONS
DESCRIPTION U.M. PAGURO 6000 PAGURO 9000 PAGURO 14000 PAGURO 18000 PAGURO 6500 PAGURO 8500
Engine cooling
system capacity l 2 2 3 4.25 3 4.25
Engine rotation
speed rpm 3000 (50 Hz) 3000 (50 Hz) 3000 (50 Hz) 3000 (50 Hz) 1,500 (50 Hz) 1,500 (50 Hz)
3,600 (60 Hz) 3,600 (60 Hz) 3,600 (60 Hz) 3,600 (60 Hz) 1,800 (60 Hz) 1,800 (60 Hz)
Continuous
electrical power
50 Hz 6 Kwa-5 kW 9 kVA-8 kW 14 kVA-14 kW 18 kVA-18 kW 6.5 kVA-6 kW 8.5 kVA-8 kW
60 Hz 6.5 kVA-8 kW
5.5 kW
10 kVA-8 kW
8.5 kW
16 kVA-8 kW
14 kW
21 kVA-8 kW
18 kW 6.5 kVA-6.5kW 8.5 kVA-8.5
kW
Single phase
output voltage (V)
230 (50 Hz) 230 (50 Hz) 230 (50 Hz) 230 (50 Hz) 230 (50 Hz) 230 (50 Hz)
115/230
60 Hz
115/230
60 Hz
115/230
60 Hz
115/230
60 Hz
115/230
60 Hz
115/230
60 Hz
Peak current A 70 (50 Hz) 102 (50 Hz) 180 (50 Hz) 230 (50 Hz) 72 (50 Hz) 102 (50 Hz)
140 (60 Hz) 204 (60 Hz) 360 (60 Hz) 460 (60 Hz) 144 (60 Hz) 204 (60 Hz)
Electric start
and stop system (V) 12 12 12 12 12 12
Specific diesel
fuel
consumption
l/kW/
h. 0.35 0.35 0.35 0.35 0.35 0.35
INTERNAL DIAMETERS SPECIFICATIONS
DESCRIPTION U.M. PAGURO
6000
PAGURO
9000
PAGURO
14000
PAGURO
18000
PAGURO
6500
PAGURO
8500
Water inlet (mm) 19 x 1/2” 19 x 1/2” 19 x 1/2” 19 x 1/2” 19 x 1/2” 19 x 1/2”
Exhaust line (mm) 40 40 45 45 40 45
Diesel fuel supply (mm) 8 8 8 8 8 8
Diesel fuel return (mm) 8 8 8 8 8 8
Anti-siphon valve (mm) 19 19 19 19 19 19
REMOTE CONTROL PANEL SPECIFICATIONS
DESCRIPTION U.M. VALUE
Dimensions (L x P x H) (mm) 99.9 x 69.6/108.4
Weight g ≈ 290
Electronic protection IP 65
Electronic protection - connectors IP 65
Operating temperature °C. 10 ÷ 60
Power supply (Vdc) 8/30
Consumption (pre alternator excitation) mA ≈ 122
LCD screen resolution pixels 128 x 1/64

1 TECHNICAL SPECIFICATIONS
Mod. PAGURO
6000/9000/14000/18000/
6
50
0/8
5
00
Date: 12.03.2020_Rev: 0.0
3
Below is the Generator with a basic description of the main units and components installed.
Internal Paguro 6000/9000/14000/18000/65000/8500
Key:
1. Lifting eye; 8. Heat exchanger;
2. Engine oil dipstick; 9. Seawater pump;
3. Manual engine oil extraction pump; 10. Electrical box;
4. Lower capsule; 11. Lifting eye;
5. Bracket with soft vibration supports; 12. Exhaust manifold.
6. Oil filler cap; 13. Alternator;
7. Coolant filler cap;
1
2
3
7
6 9
11
12
10
5
13
4
8

1 TECHNICAL SPECIFICATIONS
Mod. PAGURO
6000/9000/14000/18000/
6
50
0/8
5
00
Date: 12.03.2020_Rev: 0.0
4
1.3 COPYRIGHT
ATTENTION! All rights are reserved under the "INTERNATIONAL COPYRIGHT CONVENTIONS", it is
forbidden to reproduce any part of this manual in any form, without the express written permission of the
Manufacturer VTE S.r.l.
The contents of this guide are subject to change without notice. Every care has been taken to collect and verify
the documentation contained in this manual in order to make the guide as complete and understandable as
possible.
Nothing in this publication shall be interpreted as warranty or explicit condition or implicit-included condition,
but not limited to the warranty of suitability for a particular purpose. Nothing in this publication shall also be
interpreted as modifying or asserting the terms of any purchase agreement.

2 OPERATING CONDITIONS
Mod. PAGURO
6000/9000/14000/18000/
6
500
/8
5
00
Date: 12.03.2020_Rev: 0.0
1
2. OPERATING CONDITIONS
2.1 COMPARTMENT
Paguro generator has been designed and manufactured to operate on board boats and in a well ventilated
and closed compartment, where there are no danger of explosion or fire.
The Marine generator containment compartment must ensure minimum distances for correct air replacement.
2.2 VENTILATION
The minimum distances indicated in the image below are recommended around the generator. The
environment in which the generator is installed must be naturally ventilated and have more than one opening
to the outside. Select a compartment that allows adequate air flow for the engine air intake.
Generator compartment - example
Minimum air change distance
2.3 CHARACTERISTICS OF THE OPERATING ENVIRONMENT
This generator has been designed and realized to work only at the environmental conditions listed here below:
Area temperature range: value between +5 °C and +40 °C.
Maximum RH without condensation: 90% at 20°C.
FRESH
AIR
INLET
HOT AIR
OUTLET
ENGINE
COMBUSTION AIR INTAKE
CONNECTIONS SIDE
200 MM
This manual suits for next models
5
Table of contents
Other Volpi Tecno Energia Portable Generator manuals
Popular Portable Generator manuals by other brands

Sony
Sony BKP-5974 quick start guide

DUROMAX
DUROMAX XP13000X user manual

Mosa
Mosa GE 40 YSX-5 Original instructions

Horizon Fuel Cell Technologies
Horizon Fuel Cell Technologies H-500XP user manual

SHL
SHL VETROSON Oxy-Gen VGS2015 Installation, operation & maintenance manual

Vitals
Vitals EST 8.5b Manual For Technical Use

kinetic
kinetic V660 instruction manual

Hyundai
Hyundai DHY12000SE(-3) user manual

King Canada
King Canada Power Force KCG-950G instruction manual

Parker
Parker NitroFlow HP user manual

Champion Global Power Equipment
Champion Global Power Equipment 201046 quick start guide

Agilent Technologies
Agilent Technologies E8267C Service guide