Nano UPS Quick Guide V.1.0
Package Contents
You should have received the following items inside of package:
- UPS Unit
- Quick Guide
-Power cable (only for the IEC-type model)
1
2
Front View:
4Installation & Initial Startup
NOTE: Before installation, please inspect the unit. Be sure that
nothing inside the package is damaged.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate
air flow. Please place the UPS away from other units at least 20 cm to avoid
interference. Do NOT operate the UPS where the temperature and humidity is
outside the specific limits. (Please check the specs for the limitations.)
Connect to Utility and Charging
Before initial use, please plug in the AC input cord to the
wall outlet and turn on the UPS for charging. For the best
results, suggest to charge the battery at least 8 hours
before initial use. The UPS charges its battery while
connecting to the utility with power on.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply
turn on the power switch of UPS unit, then devices connected to the UPS will
be protected by UPS unit.
CAUTION: NEVER connect a laser printer or scanner to
the UPS unit. This may cause the damage of the unit.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by
pressing again the power switch.
Indicators & Alarm Table for Operation
Back View:
8 hours
AC input
Output receptacles
Circuit breaker
Power switch
UPS status indicator
Fault/Battery status indicator
(Check the Indicator & Alarm Table for the details)
1
2
3
IEC Type
1
2
3
NEMA Type Universal Type Schuko Type
Product Overview
3
Product Introduction
1
2
3
20cm 20cm
The Nano UPS provides comprehensive protection in a small and economic package.
The UPS is more compact and offers greater comprehensive power protection against
surges and spikes. This UPS will continue providing stable power to connected
equipment and enable to shutdown PC safely during power failure. Its embedded
microprocessor controller guarantees high reliability and it’s perfect for any home
or small office application.
Conditions Visual Indications Alarm
Off
Green LED lighting
Green LED flashing
every 10 seconds
Green LED flashing every
second & Red LED lighting
Sounding every 10 seconds
Sounding every second
AC mode
Battery mode
Low battery at
battery mode
Fault Red LED lighting Continuously sounding
1
2
3
2
3
1
Alarm for over-
temperature
protection
Red LED flashing every 0.5
seconds Off
Trouble Shooting
6
Use the table below to solve minor problems.
Important Safety Warning
(SAVE THESE INSTRUCTIONS)
5
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and
humidity controlled indoor area free of conductive contaminants. (See the
specifications for the acceptable temperature and humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling
vents and avoid exposing the unit to direct sunlight or installing the unit near heat
emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment,
life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place
beverages or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the
power cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! If the UPS is with metal chassis, for safety purpose, grounding is a must
during UPS installation in order to reduce leakage current below 3.5mA.
Attention hazardous through electric shock. Also with disconnection of this unit
from the mains, hazardous voltage still may be accessible through supply from
battery. The battery supply should be therefore disconnected in the plus and minus
pole at the quick connectors of the battery when maintenance or service work inside
the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep unauthorized
personnel away from batteries.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not
open or mutilate the battery or batteries. Released electrolyte is harmful to the skin
and eyes.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! A battery can present a risk of electric shock and high short circuit
current. The following precaution should be observed before replacing batteries:
1) Remove watches, rings, or other metal objects.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
Specifications
7
Problem Probable Cause Solution
No LED display
on the front
panel.
Alarm continuously
sounds when the
mains is normal.
Alarm sounds every
2 seconds when the
mains is normal.
When power fails,
backup time is
shorten.
The mains is normal
but green LED is
flashing.
Low battery.
Battery fault.
The UPS is not turned on.
The UPS is overload.
UPS fault
Battery defect
Charging circuit is damaged.
The UPS is overload.
Battery voltage is too low.
Battery defect.
Power cord is loose.
Charge the UPS at least 8 hours.
Replace the battery with the
same type of battery.
Press the power switch
again to turn on the UPS.
Remove some loads first.
Before reconnecting equipment,
please verify that the load
matches the UPS capability
specified in the specs.
Return the unit to service center.
Replace the battery with the
same type of battery.
Return the unit to service center.
Remove some critical load.
Charge the UPS at least 8 hours.
Replace the battery with the
same type of battery.
Reconnect the power cord
properly.
Model Nano 400 Nano 600 Nano 800
CAPACITY
INPUT
Voltage
Voltage Range
Frequency
OUTPUT
Output Voltage (AC mode)
Output Voltage (Bat. mode)
Transfer Time
Waveform
BATTERY
Type & Number
Charging Time
PROTECTION
Full Protection
PHYSICAL
Dimension (DxWxH mm)
Net Weight (kgs)
ENVIRONMENT
Humidity
Temperature
400 VA / 240 W 600 VA / 360 W 800 VA / 480 W
12 V/4.5 AH x 1 12 V/ 7 AH x 1 12 V/9 AH x 1
8 hours recover to 90% capacity
Overcharge, discharge, short circuit, and thermal protection
110/120 VAC or 220/230/240 VAC
90~145 VAC or 180~270 VAC
50 Hz or 60 Hz
same as input
120 VAC ± 10% / 230 VAC ± 10%
2-6 ms (Typical)
Simulated Sine Wave
0-90 %
0-40 C (non-condensing)
228 x 82.5 x 207
2.2 2.7 3.1

This manual suits for next models

2

Other Voltronic Power UPS manuals

Voltronic Power Galleon One 6K User manual

Voltronic Power

Voltronic Power Galleon One 6K User manual

Voltronic Power Taurus UPS-7.5 User manual

Voltronic Power

Voltronic Power Taurus UPS-7.5 User manual

Voltronic Power 1K Online UPS For Dual-mains Input User manual

Voltronic Power

Voltronic Power 1K Online UPS For Dual-mains Input User manual

Voltronic Power 6K User manual

Voltronic Power

Voltronic Power 6K User manual

Voltronic Power 6K User manual

Voltronic Power

Voltronic Power 6K User manual

Voltronic Power Galleon II 3P User manual

Voltronic Power

Voltronic Power Galleon II 3P User manual

Voltronic Power +Power 30U-90 User manual

Voltronic Power

Voltronic Power +Power 30U-90 User manual

Voltronic Power Giant 3P/3P User manual

Voltronic Power

Voltronic Power Giant 3P/3P User manual

Voltronic Power 6K User manual

Voltronic Power

Voltronic Power 6K User manual

Voltronic Power 1K Online UPS For Dual-mains Input User manual

Voltronic Power

Voltronic Power 1K Online UPS For Dual-mains Input User manual

Voltronic Power Winner series User manual

Voltronic Power

Voltronic Power Winner series User manual

Voltronic Power Bonnie 50W User manual

Voltronic Power

Voltronic Power Bonnie 50W User manual

Popular UPS manuals by other brands

Adler Power CO-sinusUPS-500W/LCD Series user manual

Adler Power

Adler Power CO-sinusUPS-500W/LCD Series user manual

AEC NST5400 Series Operation manual

AEC

AEC NST5400 Series Operation manual

Eaton 3S850D Installation and user manual

Eaton

Eaton 3S850D Installation and user manual

Gewiss 3300 VA user manual

Gewiss

Gewiss 3300 VA user manual

Microcare 1kW24V manual

Microcare

Microcare 1kW24V manual

Vertiv Liebert PSA5 Installation and user guide

Vertiv

Vertiv Liebert PSA5 Installation and user guide

CyberPower Value600EI-AU user manual

CyberPower

CyberPower Value600EI-AU user manual

DSPM Power Lynx 1 Technical specifications

DSPM

DSPM Power Lynx 1 Technical specifications

Njoy Aira 600 user manual

Njoy

Njoy Aira 600 user manual

Newave 1000-3000VA user manual

Newave

Newave 1000-3000VA user manual

Helios SR250C user manual

Helios

Helios SR250C user manual

Phasak PH 9310 user manual

Phasak

Phasak PH 9310 user manual

CyberPower 649532210039 Specification sheet

CyberPower

CyberPower 649532210039 Specification sheet

Eaton 5P 1500 RT user manual

Eaton

Eaton 5P 1500 RT user manual

NEC 500 UPS user manual

NEC

NEC 500 UPS user manual

Powertronix Mizar user manual

Powertronix

Powertronix Mizar user manual

Beckhoff CX1100-09 Series Hardware documentation

Beckhoff

Beckhoff CX1100-09 Series Hardware documentation

Phasak PH 8010 user manual

Phasak

Phasak PH 8010 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.