FILTER AND REPLACEMENT PART ITEM NUMBERS
Vortec Model 5 micron Air Filter Oil Removal Filter Magnetic
Mounting Base Replacement Item
901XSS 701S-24A 701S-48 610-26 -
902XSS 701S-24A 701S-48 610-26 -
903XSS 701S-36A 701S-48 610-26 -
TABLE 1: FILTER RECOMMENDATIONS
TABLE 2: DETERMINING COMPRESSED AIR LINE SIZE
1. Calculate total product compressed air consumption (SCFM, SLPM).
2. Determine length of compressed air line required for connection to main supply.
3. Locate pipe length in left column and read to the right to nd the compressed air requirements.
4. Locate pipe size at top of column.
MAXIMUM AIRFLOW (SCFM) THROUGH PIPE AT 5 PSIG PRESSURE DROP (100 PSIG AND 70OF)
Pipe Length
(Feet)
Pipe Size (Nominal) - Schedule 40
1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2
10 29 65 120 254 480 978 1483 2863 4536
20 21 46 85 180 340 692 1049 2024 3208
30 17 37 70 147 277 565 856 1653 2619
40 15 32 60 127 240 489 792 1431 2268
50 13 29 54 114 215 437 663 1280 2029
60 12 26 49 104 196 399 606 1169 1852
70 11 25 46 96 181 370 561 1082 1715
80 10 23 43 90 170 346 524 1012 1604
90 10 22 40 85 160 326 494 954 1512
100 9 21 38 80 152 309 469 905 1435
MAXIMUM AIRFLOW (SLPM) THROUGH PIPE AT 0.3 BAR PRESSURE DROP (6.9 BAR AND 21OC)
Pipe Length
(Meters)
Pipe Size (Nominal) - Schedule 40
1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2
3 821 1840 3396 7188 13584 27677 42117 81023 128369
6 594 1302 2406 5094 9622 19584 29687 57279 90786
9 481 1047 1981 4160 7839 15990 24225 46780 74188
12 425 906 1698 3594 6792 13839 20999 40497 64184
15 368 821 1528 3226 6085 12367 18763 36224 57421
18 340 736 1387 2943 5547 11292 17150 33083 52412
21 311 708 1302 2717 5122 10471 15877 30621 48535
24 283 651 1217 2547 4811 9792 14829 28640 45393
27 269 623 113 2 2406 4528 9226 13980 26998 42790
31 255 594 1075 2264 4302 8745 13273 25612 40611
Rubber hose maximum airow rating: 1/2” I.D. rubber hose = 3/8” pipe; 3/4” I.D. rubber hose = 1/2” pipe

STAINLESS STEEL AIR FLOW AMPLIFIER ASSEMBLY
(Drawings shown below are not to scale)
Locking collar
-015 size O-ring (901XSS)
-019 size O-ring (902XSS)
-031 size O-ring (903XSS)
Body components
GENERAL SAFETY CONSIDERATIONS
WARNING: COMPRESSED AIR COULD CAUSE
DEATH, BLINDNESS OR INJURY
1. Do not operate Stainless Steel Air Flow Ampliers
at air pressures above 150 psig (10.3 Bar).
2. Do not operate Stainless Steel Air Flow Ampliers
at line temperatures above 400
o
F (205
o
C) without
removing internal O-Ring. Once O-ring is removed,
operation up to 800
o
F (427
o
C) is permitted. Any
resulting air leak is minimal and will not noticeably
affect the performance.
3. Avoid direct contact with compressed air.
4. Do not direct compressed air at any person.
5. When using compressed air, wear safety glasses
with side shields.
NOTE: There is no need to limit compressed air pressure
to a maximum of 30 psig (2 bar). It is not possible to
block the ow of air from the airow amplier to register
30 psig (2 bar) on a test gauge.
INTRODUCTION
A stainless steel
Air Flow Amplier
uses a small amount
of compressed air to move a much larger air volume.
Amplication ratios may meet or exceed 19:1. The output
air volume can be easily adjusted - see the Operation
section.
COMPRESSED AIR SUPPLY
The compressed air supply must be ltered to remove
water and dirt using a 5 micron or smaller lter. Failure
to use a lter may cause clogging of the compressed air
paths inside the Vortec product. Filter recommendations
are given in Table 1.
Filter elements must be changed on a regular basis.
Frequency of change is determined by the condition of
the compressed air supply. Filters should be installed in
the compressed air supply line as close as possible to the
Vortec product.
The appropriate size of compressed air supply line should
be selected to ensure optimal performance of the Vortec
product. Please refer to Table 2 to determine what supply
line size is recommended for your application.
Contact Vortec at 1-800-441-7475 for further assistance.
INSTALLATION
Air Flow Ampliers can be installed by directly plumbing to
the appropriately-sized hard piped compressed air source
that does not exceed 150 psig (10.3 Bar). See Table 2.
When the Air Flow Amplier is to be used in the ducted
applications for fume or smoke removal, the duct should
be sized to provide a ow resistance of less than 2 inches
of water column. Ducting resistance can be minimized
by using large diameter ducts for long runs, avoiding
restrictions and making large radius bends. Ducting
resistance can reduce the Air Flow Amplier’s discharge
airow, substantially affecting product performance.
MAINTENANCE
To verify lter element changing frequency, inspect the
inside of the Air Flow Amplier periodically (6 months or
less).
1. Unscrew the knurled locking collar.
2. Unscrew the two body components.
3. If dirt is observed, clean all parts and shorten the lter
element changing frequency.
4. Reassemble, setting the gap between the two body
components to give required performance. If in doubt,
set gap at 0.002” (0.05mm).
Markings from 0 to 10 on the unit indicate the gap size
(Example: 4 = 0.004”).
5. Reassemble knurled locking collar onto the two body
components.
OPERATION
In order to vary the volume of airow from the Air Flow
Amplier, an appropriately-sized pressure regulator can
be used to control the compressed air pressure, (less
pressure = less airow).
The output airow volume can also be adjusted by varying
the internal air gap. This is accomplished by loosening the
knurled locking collar and rotating the outlet barrel counter
clockwise to increase airow, clockwise to decrease
airow).
TROUBLESHOOTING
Insufficient airow may be caused by the following:
1. Undersized compressed air line size.
2. Compressed air pressure too low.
3. Partial or complete blockage of internal compressed air
path, due to dirt. See Maintenance section for cleaning
instructions; and Compressed Air Supply section for lter
recommendations.
4. Insufficient compressed air volume.
If trouble persists, please contact Vortec at 1-800-441-7475.
LIMITED WARRANTY
Vortec compressed air products manufactured by ITW Air
Management will be replaced or repaired if found to be
defective due to manufacture defect within ten years from
the date of invoice.
Refer to our website www.vortec.com for full warranty
details and limitations. ITW Air Management makes no
specic warranty merchantability or warrant of tness to a
particular purpose.
This manual suits for next models
2
Other Vortec Amplifier manuals
Popular Amplifier manuals by other brands

Texas Instruments
Texas Instruments TPA2000D1 user guide

AUSTRALIAN MONITOR
AUSTRALIAN MONITOR AMD2100P Installation and operation manual

Linear Technology
Linear Technology LTC6363 manual

Cary Audio Design
Cary Audio Design CAD 211 FE owner's manual

Musical Fidelity
Musical Fidelity Tri-Vista Instructions for use

Kramer
Kramer 901 user manual