VSLA Fresh Air Space Pro User manual

Purification coverage area approx. 3600 ft²
Fresh Air Space Pro
Owner's Manual
CAUTION: Read the manual carefully for proper procedures and operations.

Product Overall
The Fresh Air Space Pro provides continuous surface decontamination and air
purification in real-time without harmful chemicals. It is an automated, proactive,
and effective solution for your home or business.
It combines multiple complementary technologies, including H13 HEPA Filter,
Purification Plate, Plasma, and Certified Space Technology (RCI Technology)
which are the most potent surface and air purification technologies ever discovered. It
reduces most common airborne and surface contaminants, including viruses,
bacteria, VOCs, smoke, allergens, and odors.
Contents
Instructions…………………………………………………........……………...............
Product Features……………………………………......................………..............
Technical Parameters………………………………………………….............…..…
Pollution Sources that can be purified……………………….…............................
Scope of Application…………………...….................…………….........................
Inspection & Installation…………...….................……………..............................
Device Composition……………………………………..............……………...........
Operation……………………………………………….............……………...............
Settings and Adjustments…………………………..............…………….................
TFT Colorful Display Screen………………………………….....…………..............
Maintenance Reminders………………………….....…......…………….................
Maintenance Reminder…………………………………........……………...............
Removing the H13 HEPA Filter………................…………….............................
Removing the Purifier Plate & (RCI) Cell………...............……………................
Installing the (RCI) Cell & Purifier Plate …..............….……………....................
Installing the Rear Lint Screen....................…………….....................................
Indicators of Operation………........................……………..................................
Troubleshooting - What to Look for First…........................……………...............
Networking Steps of Fresh Air Space Pro...............….......……………..............
Creating Family & Adding Numbers…..............................……………...............
3
4
5
5
6
6
7
8
10
13
13
15
17
18
19
20
21
21
24
25
2
WARNING! - Do not operate this unit without the front and rear grill installed.
CAUTION!- The Away Mode feature of this unit is to be operated in
unoccupied areas only.

CAUTION!- Disconnect the power cord before servicing.
CAUTION!- Do not operate the unit near heat sources, open flames, or
combustible vapors or gases.
CAUTION!- Use extreme caution when using any appliance around children,
the elderly, or people with disabilities, and whenever the unit is operating
unattended.
CAUTION!- Keep unit out of reach of children.
Instructions
Congratulations, you have purchased one of the most effective, technologically
advanced air purifiers. Your Fresh Air Space Pro's design provides years of
trouble-free, low-maintenance operation. Be sure to read and follow all service
procedures outlined in this owner's manual, and use only genuine V.S.L.A.
replacement parts, which are available from your V.S.L.A. Business Owner.
If you have any questions concerning the unit or any V.S.L.A. product, contact your
V.S.L.A. Business Owner.
Please record the name and phone of your V.S.L.A. Dealer:
Name:__________________________________________
Phone:__________________________________________
Please record the serial number of your Fresh Air Space Pro:
Serial #:__________________________________________
3
WARNING!- Do not look directly at UV light; severe eye damage may result.

Product Features
● Positive and Negative Multipoint and RF Ion Generation
● Exclusive (RCI) Technology
● Washable Purification Plate
● H13 HEPA Filters
● TFT Colorful Display Screen
● Five-speed Fan Control
● Adjustable Purification Control (1-3600 ft², High Mode only)
● Away Mode Function w/ Adjustable Digital Timer
● Real-time display of air quality
● IntelliAir maintenance reminders
● Washable Front and Rear Grill
● Universal Power Supply with cords
● Multiplex control through the front of the unit, Remote Control or
Mobile App (Wi-Fi)
● Easy to use and low maintenance
● Able to remove airborne and surface contaminants like bacteria, and viruses
● Reduces odors, smoke, tobacco smells, allergens, and VOCs
● Safe for humans, pets and plants when used as directed
● Works 24/7 to protect from airborne and surface contamiants
4

Technical Parameters
● Technology included: Exclusive ( RCI ) Technology
Positive & Negative Multi-point and RF Ionizers
Purification Plate
H13 HEPA filter
● Electrical: Input Voltage: 100 ~ 240 VAC; 50/60 Hz
Power Supply: DC 24 Volts; 3A
Consumption: 43 Watts Max.
● Air Flow Rate: 45-65 CFM
●Dimensions: 306.5mm high x 230.5mm wide x 304.8mm deep
● Weight: 4250g
● Purifications Plate Output (High Mode): 5g/h
● Coverage:Covers a range of 300 ft.² | (28 m²) to 3600 ft.² (350 m²)*
* Depends on variables such as severity and frequency of pollution,
humidity, and temperature
● Operating Temperature:34ºF – 100ºF (-1ºC – 38ºC)
● Noise Level:40 dB(A) (on low); 50 dB(A) (on high)
● Warranty: Three years limited warranty
5
Pollution Sources that can be purified
● Formaldehyde, benzene and other harmful gases, etc.
● Peculiar smell and odor;
● Dust, smoke and tabacco smell;
● Bacteria and viruses;
●Pollen, animal hair, and dander, etc.

6
Scope of Application
● Living Room/ Bedroom/Study Room, etc.
●Restaurants/ Hotel Rooms
● Office Room/ Meeting Room
● Hotel Private Room / KTV Room
● Hospital
● Schools
● Doctor’s Offices
● Vet Clinics
● Motorhome
● Hair Salon / Bars and other public places
● Any other places requiring air purification, sterilization, deodorization and
smoke removal
Inspection & Installation
1. Remove protective packaging.
2. Remove the unit from the shipping carton.
3. Remove all protective materials.
4. Check for shipping damage and loose or broken parts.
5. Read the Owner's Manual thoroughly prior to installation.
6. Install batteries in the remote.
7. Determine placement Iocation for the unit (See "Placement of Unit" on page 10).
Plug the unit into a working electrical socket.
8. Use the remote control, the Power button, or the mobile APP to turn the unit
ON.

7
Power socket
Removable & Washable
Air Inlet Grill
Power Cord
Power Plug Power Supply
Device Composition
Removable & Washable
Air Outlet Grill
Control Panel
TFT Colorful
Display Screen
Wi-Fi Receiver
Remote Control
Receiver

Operation
1. Adjust the fan speed to your preference, keeping in mind that higher fan speeds
will give better results
2. Using the MODE button, set the unit to NORMAL for typical use or HIGH for
increased smoke and odor control
3. For HIGH MODE, using the Area Purifier UP and DOWN buttons, adjust the
purification level to its lowest setting (300ft²/ 28m²) for the first 24 hours of
operation, then gradually adjust up (if needed) to the square footage of the
indoor area
Fan Speed
8
4. To operate the AWAY MODE feature (in unoccupied areas only*) press the
AWAY button until the desired time is reached (2,4,6, or 8 hours). The unit will
display AWAY and the remaining time. To interrupt the AWAY mode, press the
MODE button
If you are operating your central heating and air conditioning fan or other
ventilation systems continuously, set the coverage up to the total ventilated
indoor area. Otherwise, set the coverage up to the size of the room. Do not
exceed the size of the ventilated indoor area when setting the purifier lever.
* Please note: “unoccupied areas” include pets. Some pets, like humans, may
experience adverse reactions from exposure to increased levels of ozone and
should not be present during AWAY mode operation.
NORMAL: The unit’s display shows the fan speed (1 bar to 5 bars) and NORMAL
to indicate that the (RCI) cell and plasma are both functioning normally
(RCI) Cell and Plasma

HIGH: The unit’s display shows the fan speed (1 bar to 5 bars), the purifier setting
(1 bar to 12 bars), and the purifier coverage in square feet for U.S. models.
9
HIGH
3600
Fan Speed
Purifier Setting
Purifier Coverage
AWAY: The fan will show maximum (5 bars), and AWAY will replace the purifier
area setting. The amount of time remaining will depend on how long you have
selected for the AWAY mode function to operate. The colon (:) will flash to
indicate time being counted down
Fan Speed (MAX)
Time Remaining
Away Mode

Placement of Unit
10
Place the unit as high as possible to insure
complete purification (on top of a bookshelf,
high cabinet, etc.)
Suggested locations (listed in the order of
preference):
1. Near the worst source of pollution.
2. Near cold-air vents, to thoroughly
circulate the benefits of your Fresh Air
Space Pro throughout the area
3. In the most frequently used area, to achieve
maximum benefit.
NOTE:
● The rear end of the unit should always have
at least one inch of open area to allow
unrestricted airflow.
● Point the unit towards the center of the
room for maximum dispersion of ions
● To prevent injury, be sure the power cord
is not accessible to small children
Settings and Adjustments
Fresh Air Space Pro can be turned on or off and adjusted using the included
remote control or the control panel on the front of the unit or the mobile app. With
the exception of the RESET button, the remote control, the control panel buttons,
and the mobile app have the same functions
POWER (Stand by)
Turns the unit ON and OFF.
FAN UP/FAN DOWN
Adjusts the five-speed fan.
PURIFIER UP/PURIFIER DOWN (HIGH mode only)
Works when the unit is in HIGH mode, which allows you to set the
purifier level for the indoor area. This level is both indicated by a
horizontal bar graph and square footage. The unit will switch to
NORMAL mode if the PURIFIER DOWN button is pressed when the
square footage is set to 300 ft²

11
If you are operating your central heating and air conditioning fan or other
ventilation systems continuously, set the coverage up to the total ventilated indoor
area. Otherwise, set the range up to the size of the room. Do not exceed the
size of the ventilated indoor area when setting the purifier level.
MODE
Toggles the unit between NORMAL mode (RCI and Ionization) and HIGH
mode (RCI, Ionization, and Purification Plate)
AWAY
Turns on and adjusts the timer for the AWAY mode function. Each press
of the AWAY mode button will increase the time by 2 hours, up to 8 hours,
then OFF. The AWAY mode should be operated in unoccupied areas only.
* Please note: “unoccupied areas” include pets. Some pets, like humans, may
experience adverse reactions from exposure to increased levels of ozone and
should not be present during AWAY mode operation.
RESET (control panel only)
Clears the maintenance reminders after performing routine maintenance
Power (ON/OFF)
Reset
Fan DOWN- Purifier DOWN-
Fan UP+ Purifier UP+
Away (ON/SET/OFF)
Mode (NORMAL/HIGH)

12
Power (ON/OFF) Reset
Purifier DOWN- Fan DOWN-
Purifier UP+ Fan UP+
Away (ON/SET/OFF) Mode (NORMAL/HIGH)

13
Maintenance Reminders
When the maintenance time is up, the Service Reminder appears in red and stays
flashing. The maintenance reminder will display the name of the component which
needs to be changed.
HIGH
3600
TFT Colorful Display Screen
The TFT colorful display screen displays all current settings (see page 8), as well
as any maintenance reminders
TFT Screen Backlight
After touching the display, the TFT backlight will turn on, and the settings on the
screen can be changed. If there is no change in 60 seconds, the backlight will
turn off.
If the maintenance time is up, a maintenance reminder or a service reminder
appears in red and stays flashing until the RESET button is pressed or the service
problem is corrected.
Fan Speed
Wi-Fi Icon
Purifier Coverage
Maintenance Reminder
Air Quality Real-Time Display
Purifier SettingReminders
(normally, blank-reminders appear here
when the unit needs maintenance)

14
REPLACE PURIFICATION PLATE
The purification plate is not functioning properly
● Replace the old plate with a new plate (availble from your local V.S.L.A.
Business owner)
REPLACE RCI CELL
The (RCI) cell is no longer working correctly
● Replace the (RCI) cell (availble from your local V.S.L.A. Business owner)
● Pleast NOTE: The (RCI) cell should be replaced every two (2) years, even if the
unit does not display this message
REPLACE PLATE
PERFORM CLEANING (approx every 30 days)
● Clean the front and rear grill openings
● Vacuum the (RCI) cell
● Clean the purification plate (see page 7)
● Vacuum front
Be sure to press the RESET button to clear the reminder following regular
maintenance (see on next page).
REPLACE RCI CELL
PERFORM CLEANING

15
Maintenance Reminder
Periodic maintenance is required to ensure that your Fresh Air Space Pro operates
appropriately. The unit will display a PERFORM CLEANING reminder when it’s time
to perform regular maintenance. If you are using your unit in a severely polluted
environment, the cleaning of the unit, purification plate, and RCI Cell should be
performed more frequently. Here are some basic procedures that should be carried
out to keep your unit running at top performance.
Failure to perform routine maintenance could adversely affect the proper function
of the unit or cause it to fail prematurely.
NOTE: If a unit is returned for repair, and it is determined that neglect of the unit
or unauthorized tampering with any mechanical or electronic component of the
unit caused the failure, this reserves us the right to void the product warranty. This
will require the owner to pay for any needed repairs.
CLEANING THE CASE:
Wipe the unit with a soft cloth dampened (not wet) with water. Do not use
chemicals or solvents. Vacuum the front and rear grills periodically to remove any
lint buildup.
CLEANING THE (RCI) CELL:
Remove the (RCI) cell and carefully vacuum any accumulated lint. Do not wash the
(RCI) cell. This may result in water damage.
REAR H13 HEPA FILTER CLEANING:
When visibly dirty, simply remove the HEPA filter from the unit (see page 17),
and with a hand-held vacuum, remove the heavy particulates. This method will
extend the life of the HEPA filter.
REAR H13 HEPA FILTER REPLACEMENT:
The HEPA filter should be changed when REPLACE FILTER appears on the display
or every six (6) months (whichever comes first). Contact your V.S.L.A. Business
Owner for a replacement HEPA filter. See pages 17 and 19 for removal and
installation instructions.
RESETTING THE REMINDERS
The only reminder that you need to reset is the HEPA filter replacement (after
performing the HEPA filter maintenance, press the RESET button, and the screen
will momentarily display CLEANED to let you know the reminder has been
cleared). All the other service reminders will clear automatically once the unit has
been turned off and back on, and the problem has been corrected.

16
CAUTION: Unplug the unit before performing any maintenance procedures.
CLEANING THE PURIFIER PLATE:
Remove the rear H13 HEPA filter (see page 17). Carefully remove the plate
vertically by holding the center of one side of the plate facing you, and
slowly pull it straight out.
If you are in an environment where there are fats, oils, or grease, such as in a
kitchen, start by cleaning with rubbing alcohol and a soft bristle brush. This
will seperate the grease without leaving a residue.
For all applications - Clean with a mixture of one part water and one-part
ammonia to remove contaminants. Place the plate into a shallow dish, and pour
enough of the water/ammonia solution into the dish to cover the plate. Allow the
plate to soak for no more than 10 minutes.
CAUTION: Damage may result from soaking the purification plate longer than 10
minutes.
Remove the plate and scrub with a soft bristle brush. Rinse thoroughly. Let
air-dry for 24 hours, or use a blow dryer to dry thoroughly.
The unit will display a REPLACE PLATE message if the purification plate needs
to be replaced.
CLEANING THE (RCI) CELL:
The (RCI) cell should be changed when REPLACE RCI CELL appears on display
or every two (2) years (whichever comes first). To change the (RCI) cell,
follow the instructions on pages 17 and 19.

Removing the H13 HEPA Filter
17
Warning: Please cut off the power prior to maintenance
HEPA Filter, follow steps 1-5
Purifier Plate, follow steps 1-6
(RCI) Cell, follow steps 1-10
1.Unplug the unit.
2. Remove the
back cover screw.
3. Remove the back
cover. The arrows show
the magnetic suction
part; tilt the bottom to
remove it.
4.Remove the
two (2)
thumbscrews
securing the top
of the HEPA
filter.
5. Remove the HEPA
filter by pulling back
the top, then lifting
up and out.
To Remove:

18
Removing the Purifier Plate & (RCI) Cell
10.Slide the (RCI) cell down and out of unit.
WARNING: Do not operate Fresh Air Space Pro without properly installing the HEPA filter
and back cover.
6.To remove the
purification plate,
grasp the edge of
the plate in the
center and
gently pull it out.
NOTE: Gently
press down on the
lower metal contact
tab if the plate is too
difficult to remove.
7.Unlock the
(RCI) Cell
connector by
pressing on the
connector’s
locking tabs.
8.Pull the
connector
straight out
to unplug.
9. Remove the
two (2)
thumbscrews.

19
4. Gently insert the purifier plate
between the guides inside the
cage until it stops.
Installing the (RCI) Cell & Purifier Plate
Warning: Please cut off power prior to maintenance.
HEPA Filter, follow steps 5-9
Purifier Plate, follow steps 4-9
(RCI) Cell, follow steps 1-9
1. Slide the (RCI) cell up and into
the unit. Be sure the back lip of
the (RCI) cell engages the two
slotted protrusions at the rear of
the plate cage and that the angle
brackets and studs are correctly
aligned.
When installing the purifier plate, be sure the
metal tabs are making contact with the screen
on each side of the plate.
2. Replace the
two (2)
thumbsrews
and tighten.
3. Insert the (RCI)
cell connector
into the plug on
the plate cage.
Press the
connector firmly
until the two tabs
lock into place.
To Install:

20
Installing the Rear Lint Screen
5. Replace the HEPA
filter, inserting the
bottom first.
NOTE: The bottom of
the HEPA filter is held
into place by two (2)
alignment guides
(see inset).
6. Secure the top of the
HEPA filter by screwing in
the two (2) thumbscrews.
7. Position the
back cover by
snapping it into
place.
8. Fasten the back
cover screw.
9. Reinstall the
power cord.
WARNING: Do not operate Fresh Air
Space Pro without the HEPA filter and
back cover properly installed.
For disassembly instructions, see page 17.
Table of contents
Other VSLA Air Cleaner manuals