manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. VUEPOINT
  6. •
  7. Rack & Stand
  8. •
  9. VUEPOINT FPM50 User manual

VUEPOINT FPM50 User manual

Other VUEPOINT Rack & Stand manuals

VUEPOINT FPM55 User manual

VUEPOINT

VUEPOINT FPM55 User manual

VUEPOINT F25 User manual

VUEPOINT

VUEPOINT F25 User manual

VUEPOINT FPM25MT User manual

VUEPOINT

VUEPOINT FPM25MT User manual

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CSAV, Inc. 2221 Hwy 36 West, Saint Paul, MN 55113 USA
Customer Service: 1-888-333-9952 • info@vuepointav.com • www.vuepointav.com
(6902-100060 <02>)
Thank you for choosing the VuePoint FPM50 monitor mount. The FPM50 is designed to support
flat-panel monitors 30 - 50 inches (76 - 127 cm), and weighing no more than 59 kg (130 lbs.).The
FPM50 is adjustable, allowing ±12˚ of tilt.
Do not use this product for any purpose not explicitly specified by VuePoint. Improper
installation may cause property damage or personal injury. If you do not understand these
directions, or have doubts about the safety of the installation, contact VuePoint Customer
Service or call a qualified contractor. VuePoint is not liable for damage or injury caused by
incorrect mounting, assembly, or use.
CAUTION
FPM50
002153.eps
VMPL50 / FPM50 - full assembly
OPT
OPT
Hardware and procedures for multiple mounting configurations are included.When
you see this symbol, choose the correct configuration to suit your needs. Not all
hardware included will be used.
6902-100060 <02>
Supplied Parts and Hardware
Before starting assembly, verify all parts are included and undamaged. If any parts are missing or damaged, do not
return the item to your dealer; contact VuePoint Customer Service. Never use damaged parts!
This product contains small items that could be a choking hazard if swallowed. Keep these items away
from young children!
WARNING
3/16 in.
(4.7 mm)
1/2 in.
(12.7 mm)
Avoid potential personal injuries and property damage! The monitor must be 30 - 50 inches (76 - 127 cm),
and must weigh no more than 59 kg (130 lbs.).The wall must be capable of supporting up to five times the
weight of the monitor and mount combined. If you have any doubts about the ability of the wall to support
the monitor, contact VuePoint Customer Service, or a qualified contractor. This product is not designed for
use in metal stud walls!
CAUTION
6902-100060 <02>
002154.eps
VMPL50 / FPM50 - wall plate and brackets
M4 x 12 mm M5 x 12mm M6 x 12 mm M8 x 16 mm
M4 x 30mm M5 x 30mm M6 x 35mm M8 x 40mm
M4 M5 M6 M8
M4 / M5 M6 / M8 M4 / M5 M6 / M8
5/16 in.
1/4-20 x 0.875 in.
001897.eps
VMPL Parts
[23] x 2
[10] x 4[09] x 4[08] x 4[07] x 4
[06] x 6[05] x 6[04] x 6
[02] x 1
[03] x 1[01] x 1
[14] x 4[13] x 4[12] x 4[11] x 4
[18] x 4[17] x 4[16] x 4[15] x 4
[22] x 4[21] x 8[20] x 4[19] x 4
[24] x 1
6902-100060 <02>
1-1
002162.eps
VMPL50 / FPM50 - Mount to wood stud
002162.eps
VMPL50 / FPM50 - Mount to wood stud
002162.eps
VMPL50 / FPM50 - Mount to wood stud
002162.eps
VMPL50 / FPM50 - Mount to wood stud
3/16 in.
[01]
[05]
[04]
30.5 - 60.9 cm
(12 - 24 in.)
Do not overtighten the lag bolts! Tighten the
lag bolts [04] only until the washers [05] are
pulled against the wall plate [01].
CAUTION
2.5 in.
6902-100060 <02>
002163.eps
VMPL50 / FPM50 - Mount to concrete
1-2
1/2 in.
002163.eps
VMPL50 / FPM50 - Mount to concrete
[05]
[04]
[01]
002163.eps
VMPL50 / FPM50 - Mount to concrete
>15 cm
(6 in.)
>64 mm
(2.5 in.)
Avoid potential personal injuries or property
damage! Never drill into the mortar between the
blocks. Be sure the plastic anchors [06] seat flush
with the blocks. If there is a layer of drywall or
other material, this drywall or other material may
not exceed 5/8 inch [15.8 mm] in thickness.
CAUTION
6x
Do not overtighten the lag bolts! Tighten the
lag bolts [04] only until the washers [05] are
pulled against the wall plate [01].
CAUTION
002163.eps
VMPL50 / FPM50 - Mount to concrete
[06]
6902-100060 <02>
2-1
002155.eps
VMPL50 / FPM50 - Back of monitor
002155.eps
VMPL50 / FPM50 - Back of monitor
[03]
[02]
[07], [08],
[09], [10]
[15], [16],
[17], [18]
[21], [22]
Use washer [21] with M4 or M5 hardware.
Use washer [22] with M6 or M8 hardware.
6902-100060 <02>
2-2
002155.eps
VMPL50 / FPM50 - Back of monitor
002155.eps
VMPL50 / FPM50 - Back of monitor
[03]
[02]
[11], [12],
[13], [14]
[15], [16],
[17], [18]
[21], [22]
[21]
[19], [20]
OPT
OPT
Use washer [21] with M4 or M5 hardware.
Use washer [22] with M6 or M8 hardware.
Use washer [21] with M4 or M5
hardware only.
OPT
OPT
6902-100060 <02>
3
002164.eps
VMPL50 / FPM50-Mount brackets to wall plate
002164.eps
VMPL50 / FPM50-Mount brackets to wall plate
[24]
2x
[23]
Avoid potential personal injuries or property damage! Be
sure to install the safety bolts [23]. Periodic tightening
may be required.
CAUTION
HEAVY! You will need assistance with this step.
6902-100060 <02>
4
002164.eps
VMPL50 / FPM50-Mount brackets to wall plate
[A]
Adjust up / down pitch.
Use the tension knob [A] to adjust the pitch tension.
OPT
OPT
CSAV, Inc. and its affiliated corporations and subsidiaries intend to make this manual accurate and complete. However, CSAV makes no claim that the information contained herein covers all
details, conditions, or variations.Nor does it provide for every possible contingency in connection with the installation or use of this product.The information contained in this document is
subject to change without notice or obligation of any kind. CSAV makes no representation of warranty, expressed or implied, regarding the information contained herein.CSAV assumes no
responsibility for accuracy, completeness or sufficiency of the information contained in this document.