WAGNERARCHITECTURAL.COM
LUBT INST R1
888.243.6914 // SYSTEMS@MAILWAGNER.COM
10600 West Brown Deer Road // Milwaukee, WI 53224, USA
BANTAM SUPPLIED PARTS:
DC/DC
mA Converter
LULFXT
Bantam
Poke-Home
Junction Box
Poke-Home
Thru-Wire
Stainless Steel Security
Mounting Screw and Bit
BANTAM™
ANOTHER
LUMENRAIL®
COMPONENT
FOR LIFE SAFETY
AND LIGHT.
PAGE 1 OF 2
INSTALLATION INSTRUCTIONS
BANTAM™
RAILING SAFETY INSTRUCTIONS:
WAGNER ARCHITECTURAL SYSTEMS ARE ENGINEERED TO MEET IBC, ADA AND NFPA WHEN PROPERLY INSTALLED.
• Check and confirm all local railing code requirements
• A structural analysis may be required per local codes and is the responsibility of the customer
• Verify with the railing manufacturer that intended retrofit installations will not degrade the integrity of their railing
• CAUTION: It is highly recommended that a professional railing installer be used for ANY rail system, illuminated or not
• Please contact the factory for field installations: 888-243-6914 or email us: systems@mailwagner.com
LIGHTING SAFETY INSTRUCTIONS:
READ THE INSTALLATION INSTRUCTIONS IN THEIR
ENTIRETY BEFORE INSTALLING. IT IS IMPORTANT
TO LEAVE THESE INSTRUCTIONS WITH THE OWNER
OR FACILITY MANAGER OF THE BUILDING FOR
FUTURE REFERENCE.
• CAUTION: Installation must be performed by a licensed electrician and all wiring must conform to
local, state and national electrical codes
• LED driver: 24VDC, Class 2, configured in a listed system of components
• Mount remote driver(s) in a NEMA rated enclosure
• Systems may be used in a wet location with a suitably rated enclosure and connections
• All electrical components must be grounded and connected to GFCI per local codes and/or the NEC
• This product must be installed in a manner consistent with its intended use
• For trouble-shooting, installation questions and replacement component orders, contact Wagner
at 888-243-6914
WARNING: TO REDUCE
RISK OF ELECTRIC
SHOCK, TURN OFF THE
ELECTRICAL SUPPLY
BEFORE INSTALLING OR
SERVICING THE LIGHT
FIXTURES AND DRIVER.
FAILURE TO DO SO MAY
RESULT IN SERIOUS
INJURY AND/OR DAMAGE
TO THE COMPONENTS.
SCAN QR CODE for technical
information, downloads,
instructions, and system
configuration guides
© 2017 R&B WAGNER, INC
WAGNERARCHITECTURAL.COM
LUBT INST R1
888.243.6914 // SYSTEMS@MAILWAGNER.COM
10600 West Brown Deer Road // Milwaukee, WI 53224, USA
1. Ensure all Bantam mounting holes (0.625”) are de-burred inside
and out. Removal of all sharp edges is necessary to protect
conductors that pass through the openings.
2. Install 24VDC positive (+) and negative (-) wires (by others) down the
length of the hand rail. Refer to the remote distance chart for wire
gauge/distance recommendations.
3. Carefully pull a loop of the 24VDC main wires out of each Bantam
mounting hole. Cut the wires at the center of each loop and strip
insulation ends back 1⁄8”.
4. Install the Poke-Home Junction Box connectors (Red) to both ends
of the 24VDC main wires and the DC converter input. Ensure that the
polarity of conductors from the converter (+ = red, - = black) connect
to the correct polarity of the main 24VDC wires.
5. Dimming: the DC converter has a 3rd input to be used for a dedicated
0-10V control. Attach the 3rd Poke-Home Junction Box connector
(Red) to the labeled (DIM) lead. Also attach the input control and
branch conductors (for additional fixtures, if applicable) into the
connector.
No Dimming: simply leave the Junction Box connector on the (DIM)
lead as a termination.
6. Install a Poke-Home Thru-Wire connector (White) to both output
wires, positive (+) and negative (-) on the DC/DC converter. Connect
the corresponding polarity leads from the Bantam on the other end.
7. Carefully feed wires, Poke-Home connectors, and DC converter
through the mounting hole, into the railing. Push components into rail
to clear mounting hole.
8. Carefully feed the remaining wire into the rail and align the Bantam
with the screw hole and tighten the security screw ½ way. Repeat
process for additional fixtures.
9. After the system is tested, loosen fixtures and place a 1⁄8” x 1⁄2” bead
of silicon caulk between the mounting and wiring holes on the back of
the housing.
10. Apply Loctite®Threadlocker Blue 242®(or equal) to the exposed
screw threads to prevent loosening and then finish seating the
Bantam fixtures. Repeat process for additional fixtures.
INSTALLATION
TO REDUCE RISK OF ELECTRIC SHOCK, TURN OFF THE ELECTRICAL SUPPLY BEFORE INSTALLING OR SERVICING
THE LIGHT FIXTURES: For retrofit applications and field drilling for Bantam installations, resealing the protective
coating on railings that are not inherently corrosion resistant is required. Paint, cold galvanizing, or an equivalent
material must be used to seal the bare metal surfaces prior to fixture installation.
1
6 7
10
2
3
4
BANTAM™
ANOTHER
LUMENRAIL®
COMPONENT
FOR LIFE SAFETY
AND LIGHT.
PAGE 2 OF 2
9
MAXIMUM REMOTE DISTANCE 100W/24VDC DRIVER WITH 5' SPACING
DC Driver Current &
Conductor AWG QTY Distance to First Fixture
from Driver
Distance to Last Fixture
from Driver
500mA - 18ga 21 10' 200'
350mA - 18ga 24 10' 200'
500mA - 16ga 21 130' 320'
350mA - 16ga 24 130' 320'
INSTALLATION INSTRUCTIONS
BANTAM™
Actual distances may vary depending on the total load, DC/DC current and fixture spacing. Verify all distance
calculations with overall design of system. Conductor supply and project gauge specification by others.

Popular Light Fixture manuals by other brands

Sound Sation Twilight 60 ENDLESS user manual

Sound Sation

Sound Sation Twilight 60 ENDLESS user manual

MOLTO LUCE CONCEPT F Mounting instruction

MOLTO LUCE

MOLTO LUCE CONCEPT F Mounting instruction

Occhio Piu alto2 track CDM Series Mounting instructions

Occhio

Occhio Piu alto2 track CDM Series Mounting instructions

ACME Xperior 5R BEAM F user guide

ACME

ACME Xperior 5R BEAM F user guide

IKEA BASISK PENDENT LAMP 8" instructions

IKEA

IKEA BASISK PENDENT LAMP 8" instructions

RUTEC VARDAflex Nova Double quick start guide

RUTEC

RUTEC VARDAflex Nova Double quick start guide

Chauvet LED-PANEL4 user manual

Chauvet

Chauvet LED-PANEL4 user manual

Federal Signal Corporation BPL26L Installation and maintenance  instruction

Federal Signal Corporation

Federal Signal Corporation BPL26L Installation and maintenance instruction

Luxrite LR25140 Installation instruction

Luxrite

Luxrite LR25140 Installation instruction

Lightolier Decorative Arco 4833 specification

Lightolier

Lightolier Decorative Arco 4833 specification

Sammode RIMBAUD Mounting instruction

Sammode

Sammode RIMBAUD Mounting instruction

Sienna Hoftronic 1S3W user manual

Sienna

Sienna Hoftronic 1S3W user manual

Patriot Lighting LF1129-WH1-16LF0-T instructions

Patriot Lighting

Patriot Lighting LF1129-WH1-16LF0-T instructions

Flash F7100311 user manual

Flash

Flash F7100311 user manual

PR TANGO 750 FRAMING manual

PR

PR TANGO 750 FRAMING manual

tempLED RayLite Pro Series installation guide

tempLED

tempLED RayLite Pro Series installation guide

FONESTAR MOV-18L instruction manual

FONESTAR

FONESTAR MOV-18L instruction manual

ETC Desire D22 quick start guide

ETC

ETC Desire D22 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.