manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. WAGO
  6. •
  7. I/O System
  8. •
  9. WAGO 750-556 User manual

WAGO 750-556 User manual

This manual suits for next models

1

Other WAGO I/O System manuals

WAGO 750-433 User manual

WAGO

WAGO 750-433 User manual

WAGO I/O SYSTEM 750 Service manual

WAGO

WAGO I/O SYSTEM 750 Service manual

WAGO WAGO-I/O-SYSTEM 750-424 User manual

WAGO

WAGO WAGO-I/O-SYSTEM 750-424 User manual

WAGO 750 Series User manual

WAGO

WAGO 750 Series User manual

WAGO 750-370 User manual

WAGO

WAGO 750-370 User manual

WAGO 750-482/000-001 User manual

WAGO

WAGO 750-482/000-001 User manual

WAGO 750 Series User manual

WAGO

WAGO 750 Series User manual

WAGO 750-530 User manual

WAGO

WAGO 750-530 User manual

WAGO 750-563 User manual

WAGO

WAGO 750-563 User manual

WAGO WAGO-I/O-SYSTEM 750 XTR Series User manual

WAGO

WAGO WAGO-I/O-SYSTEM 750 XTR Series User manual

WAGO I/O SYSTEM 750 User manual

WAGO

WAGO I/O SYSTEM 750 User manual

WAGO I/O-SYSTEM 750 Parts list manual

WAGO

WAGO I/O-SYSTEM 750 Parts list manual

WAGO I/O System 750 Series User manual

WAGO

WAGO I/O System 750 Series User manual

WAGO 750-830 User manual

WAGO

WAGO 750-830 User manual

WAGO WAGO-I/O-SYSTEM 750 XTR Series User manual

WAGO

WAGO WAGO-I/O-SYSTEM 750 XTR Series User manual

WAGO I/O SYSTEM 750 750-671 User manual

WAGO

WAGO I/O SYSTEM 750 750-671 User manual

WAGO 750-496 User manual

WAGO

WAGO 750-496 User manual

WAGO LONWORKS 750-319 User manual

WAGO

WAGO LONWORKS 750-319 User manual

WAGO I/O-SYSTEM 750-517 User manual

WAGO

WAGO I/O-SYSTEM 750-517 User manual

WAGO 750-404 User manual

WAGO

WAGO 750-404 User manual

WAGO DeviceNet 750-306 Parts list manual

WAGO

WAGO DeviceNet 750-306 Parts list manual

WAGO I/O-SYSTEM 750 User manual

WAGO

WAGO I/O-SYSTEM 750 User manual

WAGO 750-871 User manual

WAGO

WAGO 750-871 User manual

WAGO 750-540 User manual

WAGO

WAGO 750-540 User manual

Popular I/O System manuals by other brands

SMC Networks EX600-AXA Installation & maintenance manual

SMC Networks

SMC Networks EX600-AXA Installation & maintenance manual

Siemens SIMATIC ET 200SP HA Equipment manual

Siemens

Siemens SIMATIC ET 200SP HA Equipment manual

Advantech PCM-27J3AU Startup manual

Advantech

Advantech PCM-27J3AU Startup manual

Hitachi HX-RIO3 Series user manual

Hitachi

Hitachi HX-RIO3 Series user manual

ICP DAS USA tM-AD2 quick start

ICP DAS USA

ICP DAS USA tM-AD2 quick start

IFM AL1200 operating instructions

IFM

IFM AL1200 operating instructions

Allen-Bradley D Series installation instructions

Allen-Bradley

Allen-Bradley D Series installation instructions

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley

Allen-Bradley 1794-OF8IH installation instructions

Allen-Bradley SLC 500 1746-FIO4I user manual

Allen-Bradley

Allen-Bradley SLC 500 1746-FIO4I user manual

System Sensor M201E installation instructions

System Sensor

System Sensor M201E installation instructions

M-system R7D-YV2A instruction manual

M-system

M-system R7D-YV2A instruction manual

NTP Technology Penta 721 digital I/O installation guide

NTP Technology

NTP Technology Penta 721 digital I/O installation guide

Bosch B208 user manual

Bosch

Bosch B208 user manual

Acces I/O products MPCIE-ISODIO-16 Hardware manual

Acces I/O products

Acces I/O products MPCIE-ISODIO-16 Hardware manual

ExpertDAQ EX-9017F Operation manual

ExpertDAQ

ExpertDAQ EX-9017F Operation manual

SeaLevel SeaI/O-580E user manual

SeaLevel

SeaLevel SeaI/O-580E user manual

Technosoft iPOS360x MX Technical reference

Technosoft

Technosoft iPOS360x MX Technical reference

National Instruments 776570-00 user manual

National Instruments

National Instruments 776570-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Fieldbus Independent
I/O Modules
2 AO DC ±10 V
750-556
Manual
Version 1.0.2
ii • General
WAGO-I/O-SYSTEM 750
I/O Modules
Copyright ©2006 by WAGO Kontakttechnik GmbH & Co. KG
All rights reserved.
WAGO Kontakttechnik GmbH & Co. KG
Hansastraße 27
D-32423 Minden
Phone: +49 (0) 571/8 87 – 0
Fax: +49 (0) 571/8 87 – 1 69
E-Mail: [email protected]
Web: http://www.wago.com
Technical Support
Phone: +49 (0) 571/8 87 – 5 55
Fax: + 49 (0) 571/8 87 – 85 55
E-Mail: [email protected]
Every conceivable measure has been taken to ensure the correctness and com-
pleteness of this documentation. However, as errors can never be fully ex-
cluded, we would appreciate any information or ideas at any time.
E-Mail: [email protected]
We wish to point out that the software and hardware terms as well as the tra-
demarks of companies used and/or mentioned in the present manual are gener-
ally trademark or patent protected.
Content • iii
WAGO-I/O-SYSTEM 750
I/O Modules
Content
1Important Comments ................................................................................. 4
1.1 Legal Principles........................................................................................4
1.1.1 Copyright............................................................................................. 4
1.1.2 Personnel Qualification .......................................................................4
1.1.3 Intended Use ........................................................................................4
1.2 Symbols....................................................................................................5
1.3 Number Notation......................................................................................5
1.4 Safety Notes .............................................................................................6
1.5 Scope ........................................................................................................6
2I/O Modules ................................................................................................. 7
2.1 Analog Output Modules ...........................................................................7
2.1.1 750-556 [2 AO DC ±10 V]..................................................................7
2.1.1.1 View................................................................................................7
2.1.1.2 Variations........................................................................................7
2.1.1.3 Description......................................................................................8
2.1.1.4 Display Elements ............................................................................9
2.1.1.5 Schematic Diagram.........................................................................9
2.1.1.6 Technical Data ..............................................................................10
2.1.1.7 Process Image ...............................................................................11
2.1.1.7.1 Standard Format .......................................................................12
2.1.1.7.2 Special Formats........................................................................12
4 • Important Comments
Legal Principles
WAGO-I/O-SYSTEM 750
I/O Modules
1 Important Comments
To ensure fast installation and start-up of the units described in this manual,
we strongly recommend that the following information and explanations are
carefully read and abided by.
1.1 Legal Principles
1.1.1 Copyright
This manual is copyrighted, together with all figures and illustrations con-
tained therein. Any use of this manual which infringes the copyright provi-
sions stipulated herein, is not permitted. Reproduction, translation and elec-
tronic and photo-technical archiving and amendments require the written con-
sent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will entail
the right of claims for damages.
WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform modi-
fications allowed by technical progress. In case of grant of a patent or legal
protection of utility patents all rights are reserved by WAGO Kontakttechnik
GmbH & Co. KG. Products of other manufacturers are always named without
referring to patent rights. The existence of such rights can therefore not be
ruled out.
1.1.2 Personnel Qualification
The use of the product detailed in this manual is exclusively geared to special-
ists having qualifications in PLC programming, electrical specialists or per-
sons instructed by electrical specialists who are also familiar with the valid
standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability re-
sulting from improper action and damage to WAGO products and third party
products due to non-observance of the information contained in this manual.
1.1.3 Intended Use
For each individual application, the components supplied are to work with a
dedicated hardware and software configuration. Modifications are only per-
mitted within the framework of the possibilities documented in the manuals.
All other changes to the hardware and/or software and the non-conforming use
of the components entail the exclusion of liability on part of WAGO Kon-
takttechnik GmbH & Co. KG.
Please direct any requirements pertaining to a modified and/or new hardware
or software configuration directly to WAGO Kontakttechnik GmbH & Co.
KG.
Important Comments • 5
Symbols
WAGO-I/O-SYSTEM 750
I/O Modules
1.2 Symbols
Danger
Always abide by this information to protect persons from injury.
Warning
Always abide by this information to prevent damage to the device.
Attention
Marginal conditions must always be observed to ensure smooth operation.
ESD (Electrostatic Discharge)
Warning of damage to the components by electrostatic discharge. Observe
the precautionary measure for handling components at risk.
Note
Routines or advice for efficient use of the device and software optimization.
More information
References on additional literature, manuals, data sheets and INTERNET
pages
1.3 Number Notation
Number Code Example Note
Decimal 100 normal notation
Hexadecimal 0x64 C notation
Binary '100'
'0110.0100'
Within ',
Nibble separated with dots
6 • Important Comments
Safety Notes
WAGO-I/O-SYSTEM 750
I/O Modules
1.4 Safety Notes
Warning
Switch off the system prior to working on bus modules!
In the event of deformed contacts, the module in question is to be replaced, as
its functionality can no longer be ensured on a long-term basis.
The components are not resistant against materials having seeping and insu-
lating properties. Belonging to this group of materials is: e.g. aerosols, sili-
cones, triglycerides (found in some hand creams).
If it cannot be ruled out that these materials appear in the component envi-
ronment, then additional measures are to be taken:
- installation of the components into an appropriate enclosure
- handling of the components only with clean tools and materials.
Attention
Cleaning of soiled contacts may only be done with ethyl alcohol and leather
cloths. Thereby, the ESD information is to be regarded.
Do not use any contact spray. The spray may impair the functioning of the
contact area.
The WAGO-I/O-SYSTEM 750 and its components are an open system. It
must only be assembled in housings, cabinets or in electrical operation
rooms. Access must only be given via a key or tool to authorized qualified
personnel.
The relevant valid and applicable standards and guidelines concerning the
installation of switch boxes are to be observed.
ESD (Electrostatic Discharge)
The modules are equipped with electronic components that may be destroyed
by electrostatic discharge. When handling the modules, ensure that the envi-
ronment (persons, workplace and packing) is well grounded. Avoid touching
conductive components, e.g. gold contacts.
1.5 Scope
This manual describes the Analog Output Module 750-556
2 AO DC ±10 V of the modular WAGO-I/O-SYSTEM 750.
Handling, assembly and start-up are described in the manual of the Fieldbus
Coupler. Therefore this documentation is valid only in the connection with the
appropriate manual.
750-556 [2 AO DC ±10 V] • 7
View
WAGO-I/O-SYSTEM 750
I/O Modules
2 I/O Modules
2.1 Analog Output Modules
2.1.1 750-556 [2 AO DC ±10 V]
2-Channel Analog Output Module ±10 V
2.1.1.1 View
A1 A2
13 14
C
D
B
A
MM
SS
750-556
AO 2
Data contacts
Function AO 2
Function AO 1
AO 1
Shield
(screen)
Shield
(screen)
Common
(ground)
Common
(ground)
Fig. 2.1.1-1: 2-Channel Analog Output Module 750-556 g055600e
2.1.1.2 Variations
Item-No.: Designation Description
750-556 2 AO (±10 V) 2-Channel Analog Output Module , ±10 V
750-556/000-200 2 AO (±10 V)
with Siemens
(S5-FB 251)
2-Channel Analog Output Module , ±10 V,
adapted data format for S5-control systems
with the use of function block FB 251
8 • 750-556 [2 AO DC ±10 V]
Description
WAGO-I/O-SYSTEM 750
I/O Modules
2.1.1.3 Description
The analog output module 750-556 and its variation create a standardized sig-
nal of ±10 V.
The module has two short circuit protected output channels and enables the di-
rect wiring of two 2-conductor actuators to AO 1 and ground or AO 2 and
ground. The signals are transmitted via AO 1 or AO 2.
The channels have a common ground and a shield (screen) (S). The shield
(screen) is directly connected to the DIN rail. A capacitive connection is made
automatically when snapped onto the DIN rail.
The input signal is electrically isolated and will be transmitted with a resolu-
tion of 12 bits.
The operational readiness and the trouble-free internal data bus communica-
tion of the channels are indicated via a function LED.
Any configuration of the output modules is possible when designing the field-
bus node. Grouping of module types is not necessary.
The voltage supply is done via the internal system voltage.
Attention
This module has no power contacts. For field supply to downstream I/O mod-
ules, a supply module will be needed.
The analog output module 750-556 and its variations can be used with all cou-
plers/controllers of the WAGO-I/O-SYSTEM 750 (except for the economy
types 750-320, -323, -324 and -327).
750-556 [2 AO DC ±10 V] • 9
Display Elements
WAGO-I/O-SYSTEM 750
I/O Modules
2.1.1.4 Display Elements
LED Channel Designation State Function
off
No operational readiness or the
internal data bus communication
is interrupted
A
green 1 Function
AO 1
on Operational readiness and trou-
ble-free operational readiness
off
No operational readiness or the
internal data bus communication
is interrupted
13 14
C
D
B
A
CA
Fig. 2.1.1-2: Display
Elements g055202x C
green 2 Function
AO 2
on Operational readiness and trou-
ble-free operational readiness
2.1.1.5 Schematic Diagram
Shield
(screen)
AO 1 AO 2 AO
10nF
270pF
A
DLogic
Function
Shield
(screen)
Common
(ground)
Common
(ground)
1
2
3
4
5
6
7
8
750-556
Fig. 2.1.1-3: 2-Channel Analog Output Module 750-556 g055601e
10 • 750-556 [2 AO DC ±10 V]
Technical Data
WAGO-I/O-SYSTEM 750
I/O Modules
2.1.1.6 Technical Data
Module Specific Data
Number of outputs 2
Current consumption typ. (internal) 65 mA
Voltage supply via system voltage DC/DC
Signal voltage ±10 V
Load impedance > 5 kΩ
Linearity ±10 mV
Resolution 12 Bit
Conversion time approx. 2 ms
Output filter settle time typ. 300 µs
Measuring error 25°C <±0.1 % of the full scale value
Temperature coefficient <±0.01 % /K of the full scale value
Isolation 500 V (Field/System)
Bit width 2 x 16 bits data
2 x 8 bits control/status(option)
Dimensions (mm) W x H x L 12 x 64* x 100
* from upper edge of 35 DIN rail
Weight ca. 55 g
Standards and Regulations (cf. Chapter 2.2 of the Coupler/Controller Manual)
EMC-Immunity to interference (CE) acc. to EN 50082-2 (96)
EMC-Emission of interference (CE) acc. to EN 50081-1 (93)
EMC-Immunity to interference
(Ship building)
acc. to Germanischer Lloyd (97)
EMC-Emission of interference
(Ship building)
acc. to Germanischer Lloyd (97)