wallas 4430 Manual

604398.ai 1 3.11.2011 13:38:19
4430
Remote Control System
en Installation, operation and service instructions

en
Contents
27 Technical information
27 Important notice
27 Package contents
28 Introduction
28 Operating
28 Technical information
29 Quick guide
30 Installation
30 General information
30 Subscriptions and SIM cards
30 Prepare the SIM card
31 Installing the SIM card
31 Installing the GSM aerial
31 Connecting of heaters 22 Dt, 30 Dt, 40 Dt, 26CC and 40CC
32 Connecting of heaters 1800 t and 2400 t
32 Connecting to the heater’s control panel
33 Relays
33 Data input
33 Power source
34 Preparing for start-up
34 Starting
34 GSM signals
35 Operation
35 Remote control via a web browser
35 Supported browsers
35 Registration
37 Settings
37 Heater settings
40 Panel settings
41 User settings
42 Use
43 Starting and stopping the heater
43 Adjusting heater temperature
44 Remote control by text messages
44 Controls
44 Control commands
44 “W” – Wallas heater control
45 Other commands
45 “S” status
45 Connections for a Wallas heater
45 Frequently Asked Questions
46 Resetting the factory settings (Reset)
47 Maintenance
47 Maintenance
47 Waste Electrical and Electronic Equipment
48 Disclaimer
48 Limited Warranty
D90020
- 2 -
4430
490538

4430
en
Technical information
Fastening screw 4,2 x 132 pcs
GSM/GPRS remote control
GSM/GPRS remote control aerial
Accessory bag
Connection cable
Mounting bracket, black
1 pcs
1 pcs
1 pcs
1 pcs
1 pcs
Installation, operation and maintenance instructions1 pcs
Package contents
Important notice
•Please read the instruction manual carefully.
•Make sure to observe all the warnings.
•Do not expose the unit to water or humidity.
•Clean the unit by wiping carefully with a dry cloth.
•Observe the installation instructions.
•Only use accessories, which have been recommended by Wallas-Marin Oy.
•Do not open the unit or try to repair it when any malfunction occurs. All repairs
must be performed by an authorised service provider. Additional information is
available from the equipment dealer.
DO NOT expose the unit to water or keep it in a humid room.
Water and other liquids can cause malfunctions. The warranty does
not cover such damages. The unit is intended for use indoors, and in
a dry environment.
Do not open the unit in the case of a malfunction. This will invalidate
the warranty.
The unit is remote-controlled and functions in a GSM and GPRS
network. The unit can be used if it is installed in an area with GSM
network coverage.
D80081
- 27 -
4430
490538

-20 - +40 °C
-30 - +50 °C
20 x 106 x 60 mm
5 A, 50 V
80 g
< 93 % RH
300-8011V16
en
Technical information
Introduction
The remote starter 4430 is intended for communicating data through a GPRS
network. The unit is intended for remote controlling of heating devices. The unit
can be used for starting and stopping the heater, for adjusting thermostat settings
(temperature), and for monitoring accumulator voltage and the temperature of the
premises being heated. Typical areas of application are ON/OFF switching of boat
and cottage heaters, and controlling of temperature and operating voltage. The
unit is controlled remotely by a PC via the most generally used web browsers, or
by smart phones. In an area with the GPRS network coverage the unit can also be
controlled by text messages in a GSM network.
Operating
The unit is controlled by a web browser programme (GPRS), or by text messages
(GSM). Controlling of the heater on a web browser the heater takes place in the
same way as in the control panel of the heater. In addition to signal lamps the vir-
tual panel on the browser displays the accumulator voltage and the room tempera-
ture (°C / F). By enquiring status data outside the GPRS network information about
all settings are communicated in a clear text message. The return text message is
in English.
In order to communicate data the remote starter requires at least GSM network
coverage. If the network coverage is poor we recommend using an external aerial.
The strength of the signal is displayed by the LED lights of the remote starter.
Green light means good signal, red lights means poor signal, and if there is no
signalthelightisoff.TheLEDlightashesonceeveryca7seconds.Ifatextcom-
mand is received the LED light stays green for 1–2 seconds.
Type
Average: 20 mA, 12 V DC
Relays: Each for 32 mA, 12 V DC
GSM with a direct MMCX connector
Class 4 (2 W), 850 / 900 MHz
Class 1 (1 W), 1800 / 1900 MHz
Operating voltage
Operating temperature
Maintenance temperature
Power consumption
Measurements
Weight
Aerial
Case
Relay
Humidity
Power
Technical information
push/push typeSIM card
Four frequency GSM / GPRS modem
(850, 900, 1800 and 1900 MHZ)
GSM / GPRS modem
7.5 -15.0 V DC
At least 1 A, operating output at least 1 W
IP class: IP20
D80071
- 28 -
4430
490538

en
Quick guide
1. Switch off the main power from the heater (disconnect the
accumulator cable)
2. On web page remote.wallas. check that the SIM card opera-
tor is included in the tested operator list.
3. Check that the PIN code request of the SIM card is disabled.
If necessary, disable it.
4. Install the SIM card in the remote control
5. Connect the remote control to the heater’s operating switch
GSM aerial interface
6. Install and connect the aerial
7. Switch of the heater’s main power
8. Ensure that the green LED light starts ashing with 7 sec
intervals
9. Register as a user on the web page remote.wallas. by using
the instructions on the screen
10.Save the control page as a bookmark (ask to conrm your
password), this facilitates the use of the remote control
D30081
- 29 -
4430
490538

1 2 3
5
4
en
Installation
General information
1) Data communication serial port
2) Power supply input (heaters 1800 t and 2400 t)
3) Relay output
4) Buttons and the LED light relays activation on the spot.
5) LED light indicating the GSM signal status.
Subscriptions and SIM cards
All data communication takes place in a GSM/GPRS network. In order to communi-
cate with the unit it is required to install a SIM card in it. The unit accepts SIM cards
of different operators, the list of approved/tested operators is available on the web
page remote.wallas.. Ask the unit dealer for more information concerning suitable
SIM cards, since there is a number of different SIM cards available.
Note:
It is advisable to get a monthly charged SIM card with data transmission features
for your unit.
If you use prepaid SIM cards do not forget to reload them, when the balance is
about to run out. 4430 does not function properly if the SIM card is not used cor-
rectly.
Prepare the SIM card
4430 requires the SIM card’s PIN code request to be OFF.
Deactivating the PIN code request feature.
1. Install the SIM card in the GSM phone.
2. Activate the phone and enter the PIN code.
3. Go to the security settings of the phone and disable the PIN code request fea-
ture. See more detailed instructions in the GSM phone’s user manual.
In some SIM cards the PIN code request feature is not activated, which means that
the card is ready for use.
D10241
- 30 -
4430
490538

TXU
RXI
GND
T1
T2
GND
l1
l2
S
GND
+12V
GND
R1
R2
R3
R4
Installation en
Installing the SIM card
1. Make sure that 4430 has not been connected to the operating switch through a
cable.
2. Placethecardinthepositionshownonthegurebelow.
GSM aerial interface
3. Push the SIM card into the card slot. A click indicates that the card has been
locked in place.
To remove the SIM card push it inwards and it springs up from the SIM card slot.
Installing the GSM aerial
Try to position the aerial vertically as high as possible.
Note that the aerial MUST NOT be mounted directly on a metal surface or near
metal objects. These can interfere with GSM signals. GSM aerials covering all the
four frequency areas with MMCX connector can be used as aerials.
Connecting of heaters 22 Dt, 30 Dt, 40 Dt, 26CC and 40CC
The cables are pre-connected to the connectors at the manufacturer’s plant.
Connect the connectors to the 4430unitasshownonthegure.
Note that the 4430 unit gets its operating voltage from the heater’s control panel,
no separate power supply is required.
White
Green
Yellow
Brown
D10241
- 31 -
4430
490538

TXU
RXI
GND
T1
T2
GND
l1
l2
S
GND
+12V
GND
R1
R2
R3
R4
Installation en
White
Green
Yellow
Red
Black
BATTERY
Shield the free cable end to
prevent short circuits
Connecting of heaters 1800 t and 2400 t
With the heaters 1800 t and 2400 t the operating switch turns on 8V voltage, which
runs the 4430 unit, but the voltage reading on the display is incorrect (8V). It is ad-
visable to take the power for these units directly from the accumulator via a sepa-
rate fuse, in which case the reading on the display will be correct.
The power cable must have
at least a 1 A fuse
Connecting to the heater’s control panel
D10241
- 32 -
4430
490538

Installation en
Relays
4430 has 2 zero-voltage relays. These can only be controlled by text messages or
with two buttons on the equipment. Relay outputs are marked as R1 and R2.
Data input
4430 has 2 data interfaces, TXU and RXI. They are intended only for connecting to
an external Wallas equipment using the cable included in the delivery.
Power source
A Wallas heater functions as a power source in the following equipment 22 Dt, 30
Dt, 40 Dt, 26CC and 40CC.
When heaters 1800 t and 2400 t, are used, it is advisable to connect the 4430 unit
directly to the same 12V accumulator, which is used by the heater.
Do not switch the power on (connect the power cable to the heater)
before all connections have been made.
When the power is connected to the heater it is prohibited to touch
(disconnect or connect) any 4430 connectors.
D10241
- 33 -
4430
490538

Installation en
Preparing for start-up
Starting
After all the connections have been made and the SIM card (with disabled PIN
code) has been installed, the 4430 unit may be started.
Switch on the heater’s main power / heaters power cable back, and monitor the
LED light on the remote control.
• During the starting stage the LED light is red, and after a while its colour turns
greenanditstartsashinguniformlywith7secondintervals.
• IftheSIMcardismissingoriftheSIMcardisfaulty,theLEDlightstartsash-
ing green after a couple of seconds. In this case check the PIN code and
ensure that the card is well in its place.
• Errorsaresignalledbytwoshortrepetitiveashes(twoashes–apause–two
ashes…)(e.g.ifthePINcoderequesthasnotbeendisabled).
• AredashingLEDlightsignalsofanerrorintheself-checkingprogram.
Please contact the equipment dealer.
GSM signals
The strength of the GSM signal can be determined by the LED light of the signal.
TheLEDlightasheswiththeintervalofca7seconds.
• A green light means that the signal is good.
• A red light means that the signal is weaker/ poor.
• No light means that there is no signal. In this case the unit cannot be remotely
controlled.
In the two latter cases try to move the GSM aerial to improve the signal. One of the
options is to purchase an external aerial. GSM aerials covering all the four frequen-
cy areas with MMCX connector can be used as aerials.
Boat trips between several countries:
If you intend to take boat trips to more than one country, please
check whether the SIM card features are suited for the local operator
(Roaming)
Please note that applicable charges differ considerably under differ-
ent Roaming agreements!
If necessary remove the SIM card from the unit to prevent excessively
high charges.
If you intend to stay abroad for a long time, it is advisable to pur-
chase a SIM card of a local operator, if you intend to use the 4430
remote starter.
D10241
- 34 -
4430
490538

1
2
en
Operation
Remote control via a web browser
Supported browsers
Internet Explorer (IE), Mozilla Firefox, Safari, Chrome.
The browser must allow JavaScript and cookies (during the session).
Registration
1. Open the web browser at remote.wallas..
2. Move the cursor to the link [Create a new account] and click. This opens a new
log-in screen.
3. Enteryourrstname.
4. Enter your last name.
5. Enter your e-mail address (Wallas will send you the password to this address).
Two units cannot be registered with one and the same e-mail address.
6. You may uncheck the box ”I want to be involved in the development of Wallas
Remote Control and get information about new Wallas innovations” if you do
not wish to receive any e-mails from Wallas-Marin Oy.
7. Click [Next] to go to the next page.
D30071
- 35 -
4430
490538

345
6
7
8
910 11
Operation en
8. Enter the password received by e-mail here.
9. Enter your new password.
10. Repeat your new password here again.
11. To log in, click [Login to the panel].
D30071
- 36 -
4430
490538

1
2
3 4
5
6
Operation en
Settings
Heater settings
1. Select your heater from the drop-down menu [Device type].
2. Select your country from the drop-down menu
3. Select from the drop-down menu the operator [Operator] whose SIM card you
have got for your 4430. The accepted/ tested operators for the country selected
in the previous menu [Country] are displayed in the drop-down menu; choose
your own from the options provided. Only SIM cards provided by the operators
includedinthelistareacceptable;theunitwillmaketheappropriatecongura-
tion.
4. Enter the phone number for the SIM card in the 4430unitintheeld[Phone
number]. The area code for the respective country will be displayed according
tothecountryyouselectedinStep2.Notethattherstzero(0)ofyourphone
number has to be omitted (e.g. +358441234567, not +3580441234567)
5. Enter the SIM card number in the 4430unitintheeld[SIMcardnumber].(The
number can be found on the SIM card and it consists of at least 12 digits.)
6. Clickthe[Updateheatersetting]buttontoconguretheequipment.
D30071
- 37 -
4430
490538

0000000000000000000
00 0000000
0000000000000000000
00 0000000
1234567890123456789000
Operation en
Equipment validation takes a couple of minutes; an acceptance message will be
sent to your e-mail, and a green Psymbol is displayed on the screen; furthermore,
the IMEI code of the registered equipment is displayed on the settings page.
D30071
- 38 -
4430
490538

00 0000000
0000000000000
Operation en
If the validation was not successful, a red Osymbol is displayed on the screen.
Check whether you have entered the correct SIM card number, telephone number,
and have selected the correct operator, also ensure that the 4430 unit has been
connectedandagreenLEDisashingwithanintervalof7seconds.
Aftervericationclickthe[Updateheatersetting]buttonagaintocongurethe
equipment.
IftheGPRSsignalisweakorthetrafcoftheoperatorisovercrowdedregistration
can take a while. Wait calmly for registration, it can take even hours before the unit
is validated and you will receive a successful registration message to your e-mail.
Registration will continue even if you shut the browser on your computer.
Registered users can change the operator and SIM card data in the [Heater Set-
tings] tab. After having entered the new information click the [Update heater setting]
buttonagaintoconguretheequipment.
Wait calmly for registration, it can take even hours before the unit is
validated and you will receive a successful registration message to
your e-mail.
D30071
- 39 -
4430
490538

Operation en
Panel settings
On the Panel settings tab you can practice/ display the functioning of the control
panel in the test mode by checking the box [Enable test mode] and pressing [Save
settings].
In the test mode commands are not sent to the actual device, but instead the func-
tions of the unit are displayed in an accelerated cycle.
When the test mode is activated the control panel displays a warning “Test mode”.
The temperature unit displayed on the panel (Celsius /Farenheit) can be changed
here. After having made the selection save the setting by pressing [Save settings].
D30071
- 40 -
4430
490538

John Smith
Operation en
User settings
The User settings tab gives you access to modifying user data.
• Changetherstname
• Change the surname
• Change the e-mail address (two units cannot be registered with one and the
samee-mailaddress).Tochangethee-mailaddressitisrstnecessarytode-
lete the account by pressing [Delete account]; after this you have to complete
the entire registration process once again.
• Change the password
• Add and remove the Get information option
• Delete the account (two units cannot be registered with one and the same e-
mail address).
After having made the changes save the setting by pressing [Save user details].
If you sell the boat/ unit, do not forget to deregister the unit [Delete
account].
Show the new owner how to re-register as a user of the service.
D30071
- 41 -
4430
490538

Operation en
Use
You can access the control panel via the link [Heater] in the top right corner.
If you have not been adjusting the heater within one hour (1h) the browser logs
the user out. When you log in again, the browser will read the current status of the
heater.
The control panel functions the same way as the control panel on the equipment
itself. You can start or stop the heater, and adjust the set temperature of the ther-
mostat.
The control panel displays the temperature of the room being heated and the volt-
age supplied to the heater (updating every 20 second).
The display also shows statistics affecting the functioning of the equipment:
• when you connect to the equipment – Connecting
• when you adjust the thermostat set temperature – Set XX °C
• during the starting process – Starting
• during the stopping process – Stopping
• during the cooling process – Cooling
• if the remote control 4430 is not connected to the Wallas server – 4430 Discon-
nected
• if there are problems with connecting to the Wallas heater – Heater discon-
nected
• if there are problems with connecting to the browser – Network missing
• if the voltage is low – Low battery
• when the unit is in the locked state – Locked
• iftheamehasgoneout–Missingame
• in the case a problem occurs – Fault
D30071
- 42 -
4430
490538

Operation en
Starting and stopping the heater
During the heater starting or stopping process a dialog box appears where you can
conrmtheselection[YES][NO].Furthermore,italsocontainsanotice,warn-
ing that in the case there is a closable exhaust lead-through it is open before the
heater is started.
Adjusting heater temperature
There are two different options for adjusting the heater temperature, depending on
the operating system of your touch-screen phone.
Adjustment option 1:
To adjust the temperature, move the cursor of the mouse or, if you have a touch-
screen,yourngertothecontrolpaneladjustmentbutton.Byturningthebuttonthe
desiredtemperatureisdisplayedonthescreen;toconrmthetemperaturemove
thecursororthengerawayfromthebutton.Thesettemperatureisashingon
the screen. The set temperature is shown by the position of the button; the actual
measured temperature is displayed on the text display.
Adjustment option 2:
Toadjustthetemperaturetouch/tapwithyourngerorthemousecursoronthe
position of the power controller where you wish the controller to move. The control-
lerwillleaptotheselectedpositionandthetemperaturebeingsetisashingon
the screen. The set temperature is shown by the position of the button, the actual
measured temperature is displayed on the text display.
D30071
- 43 -
4430
490538

en
Operation
Remote control by text messages
The 4430 unit can be controlled remotely by sending text messages to the unit.
This can be done by a normal GSM phone.
The unit has a number of commands for guiding the process. Each command is dif-
ferent and contains a letter, which assigns a property to the text message. In addi-
tion to letters, numbers 1 and 0 are used as abbreviations for the ON/OFF function.
The setting can vary, but they are explained in this section.
Note that one text message can contain a combination of several commands.
General preconditions for sending a text message:
• Use the GSM phone and write your text message.
• Start the text message with the default code 1234, and then write the com-
mand.
• Send the message to the telephone number assigned to the SIM card of the
4430 unit.
Controls
S Status message.
W Wallas heater control.
NOTE:
Spaces are permitted between commands, but PROHIBITED in the middle of a
command.
“1234 W1 S4” is CORRECT, “1234 W 1 S 4“ is INCORRECT.
Control commands
“W” – Wallas heater control
Text message commands
S4 Status command
W0 Turn the Wallas heater off (stop)
W1 Turn the Wallas heater on (start)
W2xx Set the Wallas heater temperature.
Note:
The W2 command must be sent AFTER the W0 or W1 command.
W2 can be programmed within the range of +5 – +35°C. Note that the character +
does not have to be used for controlling a Wallas.
Example:
”1234 W230” means that the temperature of Wallas is 30°C.
It takes 15 seconds from the moment of entering the command to update the S4
data. Therefore it is recommended that the ON/OFF OFF/TEMPERATURE com-
mands are sent separately with an interval of at least 15 seconds.
D30061
- 44 -
4430
490538
Table of contents