Washroom-Wizard ECOBreeze User manual

Commercial
Air Filtration and Fragrance System
by
WASHROOM WIZARD LTD
Original Installation
Guide
Location Guidelines
Please note for best results the following factors have to be taken into
account:
1) The amount and positioning of airflow. (In and out flow, in flow only,
outflow only).
2) The number of users/units.
3) The size, layout of the location and the odour situation.
4) Recommended one Ecobreeze unit in every (3m x 4m room/area).
All these factors can impact the efficiency. For larger areas or
particularly odorous, busy locations extra units should be installed.
This appliance is to be used in commercial areas.
Translation of Original Instructions

Technical Information
Size (l + w +h) 220mmx180mmx62mm
Weight 670 grams.
Power cord 1.8m (2 core DC cable)
500mm (2 core AC cable)
Mains Connected 2 core hard wire (Stripped 10mm)
Power Inlet 85-260 VAC 50-60Hz
Power Adapter 6~13.5VDC
Power Consumption 12W (12V,1A)
Operating Temp: -10 to +50
Humidity: 95% RH
Polarity Protection Circuit is protected when VCC & GND are
exchanged.
PIR Sensor: Motion sensor, automatic activation,
override switch, fan speed switch,
Installations: Toilet/Baby change facilities: Permanent
with screws-to wall.
Corridors: Permanent with screws – to
wall.
Kitchens & Reception: Permanent with
screws to wall.
Alternatively in secure/controlled
environment on desk/counter.
CEC Regulation Level V
Class III Appliance: Must be used with “SELV” Power supply
only - (safety extra low voltage).
FRAGRANCE
FRESH AIR
ODOUROUS
AIR
62mm
180mm
220mm
IMPORTANT SAFETY INFORMATION
READ CAREFULLY BEFORE ATTEMPTING TO INSTALL
OPERATE OR MAINTAIN THE PRODUCT.
Protect yourself and others by observing all safety information.
Failure to comply with instructions could result in personal injury
and/or property damage.
KEEP THESE SAFETY INSTRUCTIONS IN A CONVENIENT AND
READILY ACCESSIBLE LOCATION.
Serial number:...................... Model number...................

tion General Safety Information
When using electrical appliances, basic precautions should always be followed to reduce the
• Read all instructions before servicing, cleaning or using Ecobreeze commercial unit
• The unit is intended for commercial use only.
• Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
• Before servicing or cleaning the unit ensure the power is switched by the safety
switch. This will happen when the front cover drops down.
‘motion sensor ON’. However there is access to a manual override switch located internally
at the base of the unit to ’turn OFF’the device in case of an emergency.
• Do not attempt to service the unit if the fan is still running.
• Only use allocated service key to unlock or lock unit.
• If the unit appears to be damaged/vandalised DO NOT attempt to service/clean the unit.
persons in order to avoid a hazard.
• Regular cleaning of the outside of the unit is recommended using a soft cloth, never use
strong solvents to clean the unit.
• Do not immerge unit or any working part in water or other liquid.
• Read service guide prior to servicing and follow instructions carefully as recommended by
manufacturer.
• If the installation and/or maintenance and servicing is to be completed by persons which
the manufacturer has no control or the authorized representative or maintenance persons
language is other than English, and if these instructions are required to be translated in
the correct language it is the responsibility of the agent, distributor or authorized repre-
sentative. Washroom Wizard LTD will not take liability if any such translation of original
documentation occurs.
• This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.

ARROWS INDICATE AIR FLOW OW
The following guidelines will help you
choose the optimum location for the
Ecobreeze unit.
• Ecobreeze units operate most efficiently when
installed away from outgoing (out flow) air vents.
• If there is a strong airflow in the facility the unit
should be fitted close to main odour source and
yet furthest away from extraction or air outlet.
• Ideal location is close to the main source of the
odour (near toilet or urinal).
• Male toilets - units must be installed directly
above urinal for optimum efficiency.
• Female toilets - units must be install near WC
and close to entrance door.
• Disabled Toilet/Baby change - unit must be
installed above nappy bin.
• For optimal height top screw hole height is 2
meters from floor.
• Wall mounted with appropriate screws is
recommended in public washrooms to reduce
the risk of vandalism.
4 Suggested electrical
installation situations:
1. Fix unit as per instructions to wall with screws and
screw plugs. Feed two core low voltage cable
behind the unit and through the ceiling via
transformer to closest electrical point. (Cable
guide found on back plate of unit).
2. As per installation (no.1) feed cable wire through
ceiling, fixing the transformer box in ceiling.
Feed extension back through ceiling and
connect to existing spur.
3. Electrician to install spur as to regulations,
hardwire AC to spur and securely mount
transformer with suitable safety cover.
4. Feed transformer through dry wall and run cable
to closest electrical point. Ensure transformer is
firmly secured in place.
4 Common electrical installation
situations:
1. A false ceiling installation. (Where the two core
low voltage cable is fed through the false
ceiling).
2. An existing spur installation. (Where there is an
existing spur present below ceiling).
3. An area where there are no false ceilings, or
existing spur points and only permanent walls.
4. An area with dry wall/stud walls and no existing
spur points.
Please note below are only suggested electrical installation instructions.. The unit is provided with
hardwire extension and a qualified person should connect all electrical wiring. Washroom Wizard
Ltd takes no responsibility for incorrect electrical installation or under qualified persons connect-
ing the electrical wiring.
Once the unit is mounted/fixed to the wall follow the basic electrical instructions below. Any further
queries relating to the instructions or general operating issues contact Washroom Wizard Ltd.

During transport all units are in the
locked/closed position. To open insert
service key at bottom of unit as
illustrated.
STEP 1
Push service
key into bottom
of unit, front
cover slides
down
Service
keys
access
STEP 2
Cable Guide
For electrical connection in
ceiling or spur near ceiling, tuck
cable into cable guide and feed it
through. This will ensure a ush
wall tting.
Cable
guide
on back
plate
STEP 3
Mount the back plate of the unit to the
selected location. Ensure you use the
correct wall plugs and xings for the
wall material to secure the unit. For ideal
positioning for best air circulation and
accessibility mount the unit 2 meters
(top screw hole positioning) from oor.
Screw holes
STEP 4
Once unit is xed to the wall select
appropriate setting for room.
(according to room size, odorous
environment, location, etc).
Red button
override switch
Black slide
switch for fan
speed
Note below are only suggested electrical installation and instructions. The unit is provided with
hardwire extension and a qualified person should connect all electrical wiring. Washroom Wizard
Once the unit is mounted/fixed to the wall follow the basic electrical instructions below. Any further
Safety ON/OFF
Switch (Internally)

Service Guide
Recommended Service Cycle:
Washroom Wizard Ltd cannot guarantee
performance if unit is not serviced on a regular
basis as per service instructions (Please contact
Washroom Wizard Ltd for any further advice or
recommendations with regards to replacements
and refills)
CONTACT: 020 7788 7702
or your local service provider.
Recommended
Disposal of
Consumables:
Carbon filters
Dispose of used
filters in general
waste.
Fragrance bottle
Dispose of in
appropriate recycle
waste.
STEP 1
Once
unit is
unlocked,
front
cover
drops /
slides
down.
Service key
access
Remove cap from fragrance bottle
Place inside allocated areas
STEP 2a
Fragrance bottle
chamber
Insert service key
in front filter
holder and pull
front filter holder
out.
and replace with
STEP 2b
Carbon Filter
chamber
Fragrance bottle
Slide front cover up to close
unit.
• 24 hour locations: every 6 weeks (high to medium fan speed)
• Odourous and limited airflow every 6 weeks (high fan speed)
• Medium to small areas and/or few odours every 8 weeks (medium to low fan speed).
• It is not recommended to keep the carbon filter and fragrance in unit for longer than 8 weeks without a full
exchange.
SAFETY
ON/OFF
Switch
MSDS sheets available on website.
NOTE: After placing fragrance bottle
and carbon in chamber, please
ensure front cover is firmly closed
before replacing front dust filter.
Final step...

Warning General Safety Information
When using electrical appliances, basic precautions should always be followed to reduce the
• Read all instructions before installing or using Ecobreeze commercial unit
• The unit is intended for commercial use only.
• Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
• According to wiring regulations (BS7671) and appropriate statutory regulations, it is
essential that the power source is disconnected and isolated, prior to installation or any
maintenance.
• The unit must be connected to a double pole, fused, switched connection unit (FCU)
where applicable: is in ceiling above ceiling board(s) or into existing spur that is located in
room).
the wiring rules.
• Ensure that mains supply (Voltage, Frequency and Phase) complies with the rating label.
• The unit should not be used where it is liable to be subject to direct water spray.
• The appliance is not intended to be installed, used or maintained by young children or
• If the cord is damaged it must be replaced by the manufacturer or its service agent or
• The location of the unit is important both for the safe operation and for the ecient
extraction and replacement of air within a room.
and as far away as possible from main source of air replacement in the room.
• If the installation and/or maintenance is to be completed by persons which the manufac-
turer has no control or the authorized representative or maintenance persons language is
other than English, and if these instructions are required to be translated in the correct
language it is the responsibility of the agent or distributor. Washroom Wizard LTD will
not take liability if any such translation of original documentation occurs.
IMPORTANT SAFETY INFORMATION
READ CAREFULLY BEFORE ATTEMPTING TO INSTALL
OPERATE OR ELECTRICAL MAINTAIN THE PRODUCT.
Protect yourself and others by observing all safety information.
Failure to comply with instructions could result in personal injury
and/or property damage
KEEP THESE SAFETY INSTRUCTIONS IN A CONVENIENT AND
READILY ACCESSIBLE LOCATION.
Serial number:...................... Model number...................

• For busy odourous locations fan can be set either to full or medium speed.
• For less busy or less odourous locations fan can be set to medium speed.
• For small less odorous locations fan can be set to medium/low speed.
•
•
•
• Female toilets - units must be installed near WC and close to entrance door.
• Disabled-use Toilet/Baby change - unit must be installed above nappy bin.
Please note: Once unit is installed and activated ensure fragrance bottle
placed in
carbon chamber. Inform service engineer / cleaning manager that unit
has been installed and activated.
It is recommended that in public lavatory facilities the fan should be on constantly. (Override button
pressed in and fan on full speed).
For reception areas, corridors or mainly odourless areas the fan should be on low speed.
(Please contact Washroom Wizard Ltd for any further information with regards to functions or
installation. In the unlikely event that the odorous situation has not improved after 14 days of installa-
tion please contact Washroom Wizard Ltd for further information and assistance).
CONTACT: 020 7788 7702
www.ecobreeze.com
or your local service provider.