1Check before Use
Thank you for purchasing our A2200 series. When you receive
the product, make sure that you have all the parts and that
none have been damaged during transportation. I f any part
is damaged or missing, contact your sales representative or
our sales office directly.
2Overview
The A2200 series digital power meter is a compact 4 1/2-digit
indicating meter that meets DIN standards for external
dimensions. Power is +5 V to 24 V DC type. The maximum
indication is a 19999.
2.1 Type Configuration
2.2 Checking the Accessories
The A2200 series comes with an Operation Manual (1 copy).
Should you have any questions about the manual, please
contact your sales representative or our sales office
directly.
2.3 Mounting Method
2.3.1 Panel Cutout Dimensions
For the panel cutout when mounting the A2 200 series panel
meter, follow the figure below.
2.3.2 Panel Mounting Method
To mount the A2200 series panel meter onto a panel, press
the snaps on the sides of the case and fit the meter onto
the panel from the front (see figure below).
2.4 Description of Terminals
2.4.1 Terminal Connection Diagram
2.4.2 Connection Method
The connection terminal of the A2200
series panel meter's terminals is
located inside the case.
When connecting a wire, insert it into
the case from the rear of the meter and
fasten it with a screw using a Phillips
screwdriver from the top of the rear of
the case.
Appropriate leads: 16 to 22 AWG
Recommended covering stripping
size: 6 to 7 mm
3Decimal-point Setting Method
* CAUTION
Be sure to turn off the panelmeter before changing the
decimal point position.
4Calibration Method
To calibrate this panel meter, a voltage/current generator
with an accuracy of ±0.01% or higher is required. Calibrate
it using the following procedure under ambient conditions
of 23℃±5℃and 35 to 85% R.H.
(1) Connect power to the meter and run it for more than 20
minutes.
(2) Conduct a full-scale adjustment
Apply a voltage or current equivalent to a full scale of
19900 to the input section and turn the full-scale volume
knob (figure below) so that the reading shows "1990 0."
Then apply voltage or current of the negative polarity
to check that the reading shows "-19900±(0.1% of FS)."
Digital Panel Meter
ModelA2200Series
OperationManual
(1) Using the product in ways other than specified may result in a failure of the
protection provided for the product.
(2) Please note that the information contained in this manual is subject to change
without notice due to product improvements.
(3) Every effort has been made to ensure accuracy in the presentation of this manual.
Should any errors or omissions come to your attention, or should you have any
questions, however, please contact your sales representative or our sales office
directly.
(4) After reading this manual, keep it nearby so that you can refer to it as needed.
(5) In order to prevent damage by static electricity, before changing the decimal
point position, touch a metal existing around you with the hand to discharge
static electricity charged on your body.
CAUTIONS
!
45 +0.6
-0
22.2 +0.3
-0
35mmormore
65mmormore
Panelmeter SnapSnap Mountingpanel
(Recommendedpanelthickness:
0.8 to3.5 mm)
1 2 3
Terminal
No.
1
2
3
Name
HI
LO
HOLD
Description
+ sideofinput signal
-sideof inputsignal
External controlterminal
4
50V
+V -sideofpowerterminal
+ sideofpowerterminal
4 5
!
WATANABE ELECTRIC INDUSTRY CO., LTD
Full-scalevolumeknob
-2
* The CE mark doesn’t adhere to 14 rangees.
No sign LED Standard luminance
H LED High luminance
12 12 range (±1.9999V)
Luminace :
:
Input range:
13 13 range (±19.999V)
14 14 range (±199.99V)
2 Isolated power (+5V to 24V)Power :
* High luminance LED becomes about three
times brightness for standard luminance.
022A
(Depend on our comparison.)
Insert a flat-blade screwdriver or the like into the small
hole in the lower part of the front panel acrylic section
and pry the front panel out.
When putting the front panel back into the instrument,
fit in the lugs in the upper part of the acrylic section
first.
The stud pin at the lower right is a decimal-point switch.
Short the short-circuit sockets concerned to
light the decimal point.
103-digit decimal point 102-digit decimal point
101-digit decimal point
104-digit decimal point
Operation Manual MODEL A2200 Series
UW-33507r
2021.07
5Specifications
5.1 Input Specifications
5.2 Power Specifications
●Isolated type
Supply voltage: 4.75 to 26.4 V DC
Current consumption: 5V:Approx. 80 mA
12V:Approx. 50 mA
24V:Approx. 30 mA
5.3 General Specifications
Measuring function : DC voltage measurement
Operation method : Double integration method
Input circuit : Single-ended type
Sampling rate : Approx. 2.5 times/second
Maximum display : 19999
Overrange warning : Flashing of "0000" or "-0000" if an input
signalexceeding the measurement range is
input.
Indication : Red 7-segment LED indication Character height
Approx. 10 mm
Polarity indication : If the calculation result is a negative
value,the "-" symbol is automatically
indicated.
Decimal point : Settable at any position using front-panel
short-circuit SW or sockets.
External control : Hold (shorted with the input LO terminal)
Operating temperature: 0 to 50℃, 35 to 85% R.H (no condensation)
and humidity ranges
Storage temperature : -10 to +70℃, 60% R.H or less (no condensation)
and humidity ranges
External dimensions : 48 mm (W) ×24 mm (H) ×40.0 mm (D)
Weight : Approx. 40 g
Withstand voltage : Power to input terminals 500VDC for 1minute
Case to each terminal 1500VAC f or 1minute
Insulation resistance: Power to input terminals 500VDC at 1M Ωor more
Compliance standard : EN61326-1
(*14 range is outside application)
/EMI : Class A
/EMS : Controlled EM environments
EN IEC 63000
Rated altitude : Up to 2000m
Degree of contamination : 2
Protective structure : IP40 or equivalent
*When using this product in combination with other products, customers
themselves need to ensure compliance with applicable standards, laws,
and regulations.
6External Dimensions
7Warranty and After-sales Service
7.1 Warranty
The warranty period of the product is one year from the date
of delivery. If a failure occurs during this period that is
clearly judged to be caused by a defect ascribable to
Watanabe Electric Industry, we will repair the failure or
replace any defective parts free of charge.
7.2 After-sales Service
The product has been manufactured, tested, and inspected
with strict quality control management before shipment.
Should the product break down, contact (send it to) your
sales representative or our sales office directly. (In this
case, write a detailed description of the problem and
enclose it with the product.)
Before use, ensure the safety of equipment and devices, When using this product under conditions of in an environment
not mentioned in this document, or when considering using this product for applications that may have great impact on
human life properties, therefore, requiring special safety, for example, nuclear energy control, railway, aviation,
vehicles, fuel systems, medical equipment, entertainment equipment, and safety equipment, ensure that the product is used
well below its rated parameters and performance limit, and give consideration to fail-safe and other safety measures.
Operation Manual MODEL A2200 Series
Accuracy: ±(0.1% of FS) (at 23℃±5℃, 35 to 85% R.H)
Range
12 ±1.9999V100 MΩor more ±50V
Input Impedance Maximum Allowable
Input
Maximum Resolution
Measurement Range
±19.999V
±199.99V
13
14
Approx. 1 MΩ
Approx. 1 MΩ
±120V
±250V
100μV
1mV
10mV
DC voltage measurement
48
24
10
5
40.0
7.7
4.3
FrontView
SideView
RearView
WATANABE ELECTRIC INDUSTRY CO., LTD.
6-16-19, Jingumae, Shibuya-ku, Tokyo 150-0001, Japan
Phone: (81)3-3400-6140
Homepage http://en.watanabe-electric.co.jp/
ASAHI KEIKI DIVISION
WATANABE ELECTRIC INDUSTRY CO., LTD.
6-16-19, Jingumae, Shibuya-ku, Tokyo 150-0001, Japan
Phone: (81)3-3400-6141
Homepage http://www.watanabe-electric.co.jp/en/

Other WATANABE ELECTRIC INDUSTRY Measuring Instrument manuals

WATANABE ELECTRIC INDUSTRY AM-215A User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY AM-215A User manual

WATANABE ELECTRIC INDUSTRY AS-203A Series User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY AS-203A Series User manual

WATANABE ELECTRIC INDUSTRY A7X14-X User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY A7X14-X User manual

WATANABE ELECTRIC INDUSTRY A7X18-X User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY A7X18-X User manual

WATANABE ELECTRIC INDUSTRY AM-212 Series User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY AM-212 Series User manual

WATANABE ELECTRIC INDUSTRY AL-512 Series User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY AL-512 Series User manual

WATANABE ELECTRIC INDUSTRY WPMZ-1 Series User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY WPMZ-1 Series User manual

WATANABE ELECTRIC INDUSTRY AP-301 Series User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY AP-301 Series User manual

WATANABE ELECTRIC INDUSTRY A7000 Series User manual

WATANABE ELECTRIC INDUSTRY

WATANABE ELECTRIC INDUSTRY A7000 Series User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.