weewell WHC 750 User manual

I
WHC750 User Manual 1
I
WHC 750 USER MANUAL 1
WHC 750
USER MANUAL
MODE D’EMPLOI
KULLANIM KILAVUZU
EN
FR
TR
COLD & WARM HUMIDIFIER WITH IONIZER
HUMIDIFICATEUR
IONIZERLI SOGUK & SICAK BUHAR ÜFLEYICI
HAVA TEMİZLEYİCİLER VE NEMLENDİRİCİLER

IWHC750 User Manual2
Contents
Introduction.......................................................................................................3
Descripon........................................................................................................4
Control Panel......................................................................................................4
Display...............................................................................................................4
WorkingPrinciple................................................................................................5
Features.............................................................................................................5
Correct Humidity Level.......................................................................................5
Water Filter.........................................................................................................5
Operaon Instrucons........................................................................................6
Operang Instrucons........................................................................................6
Control Buons..................................................................................................8
Lcd Display..........................................................................................................8
Trouble Shoong Guide......................................................................................9
Maintenance......................................................................................................9
How To Clean The Filter System.........................................................................10
Method A.........................................................................................................10
Method B.........................................................................................................10
How To Clean The Transducer............................................................................10
How To Clean The Basin Unit............................................................................10
Technical Data..................................................................................................11

I
WHC750 User Manual 3
Introducon
Thank you for purchasing this WHC750 ultrasonic humidier which has been designed and
manufactured to give you much year free service. You may already be familiar with using a
similar product, but do please take me to read these instrucons –they have been wrien
to ensure you get
the very best from your purchase. If you are experiencing any problem with the product
please apply Authorized Weewell Service. Safety is important. To ensure your safety and
the safety of others, please ensure you read the Safety Instrucons before you operate this
product. Keep this informaon in a safe place for future reference.

IWHC750 User Manual4
Descripon
1. «Steam» output nozzle
2. Lid
3. Handle for carrying the water tank
4. Water tank
5. Filter-cartridge
6. Water tank lid
7. Water level sensor
8. Operang chamber
9. Water tank lighng
10. Sprayer
11. Touch buons of the control panel
12. Display
13. Remote control
Control panel:
15. «POWER» on/o buon
16. «HUMIDITY» humidity level indoors seng buon
17. «MAX/MIN» humidity intensity control buon
18. «TIMER» on/o buon
19. «HEATING» heang element on/o buon
20. «OZONE» ionizaon on/o buon
Display:
21. On/o indicaon
22. Steam output intensity scale
23. Digital indicaons of room tempera ture /
mer operang me
24. Digital indicaons of room humidity / preset
humidity
25. Water heang mode indicaon
26. Empty water tank indicaon
27. Ionizaon mode indicaon
Remote control:

I
WHC750 User Manual 5
28. On/o buon
29. Ionizaon mode on/o buon
30. Water heang on/o buon
31. Timer seng buon
32. Humidity level indoors seng buon
33. Humidity intensity seng buon
Working Principle: Ultrasonic Humidier use the ultrasonic high-frequency oscillator to
break up water into ny water parcles with the diameter of about 1-5um.The venlaon
system blows out this water into the dry air where they evaporate to give the required
humidity.
Features:
High ecient in humidicaon with large output.
Low energy consumpon, save 85-90 percent of electricity of normal stream humidier.
Long lifeme
Automac control to humidity level, lack-water security protecon.
Heang Funcon: Touch the symbol of Heang to make warm mist. Press again to stop the
heang funcon.
Ozone(Anion): Touch the symbol of Ozone(Anion) to spread a number of ozone (Anion)
elements. Press again to stop the Ozone(Anion) funcon.
Correct Humidity Level:
The percentage of water mist in a given space with a given air temperature is named as
relave humidity, usually marked as %RH, i.e. 45%RH.. Atomosphereic air always contains
water vapor, the percentage of which depends on the meteorological condions. The higher
the temperature is, the more water vapor the air keeps. When the cold air is heated up to
the comfort temperature level in winter, the relave percentage of the water vapor falls.
In order to keep a comfortable and healthy environment at home, we need some arcial
addion of water vapor to room air.
• Ideal relave humidity levels under dierent situaons.
The most comfort RH for human being 45-65%RH
Ideal RH for prophylacc and curave purpose: 40-55%RH
Computer and telecom apparatuses: 45-60%RH
Furniture and musical instrument: 40-60%RH
Library art gallery and museums: 40-60%RH
Water lter:
1.The plasc part is mixed with NANO-SILVER material to prohibit the bacterium.
2.Ceramic balls can soen the hard water.
3.Ceramic lter can eliminate smells in the water.
Security Guide:
Warning: Please be aware of the following points otherwise you might be in danger if high
voltage charges.
1.Never disassembly the base unit without consult qualied personnel.
2.If the supply cord is damaged, it must be replaced by the manufacturer, its service agent

IWHC750 User Manual6
or similarly qualied persons in order to avoid a hazard.
3.Do not add detergents, chemical soluons into the unit.
4.Unplug appliance during lling, cleaning and maintenance.
5.If there is any abnormal smell during normal operaon, please switch o and disconnect
power supply and contact with service agent.
6.Never touch water in the Water Basin & components in the water when the unit is in
working.
7.Never switch on when there is no water in the water basin.
8.Never scrape Transducer.
9.Never clean Transducer with hazardous detergents, chemical soluons.
10.Never let water splash into inner Base Unit for avoiding components damage.
11.Be careful when using the appliance for emission of hot water vapor.
12.Before cleaning and maintenance, the appliance must be disconnected from the supply
main.
13.This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilies, or lack of experience and knowledge, unless they
have been given supervision or instrucon concerning use of the appliance by a person
responsible for their safety.
14.Children should be supervised to ensure that they do not play with the appliance.
15.Indoor use only.
16.Prior to cleaning or other maintenance, the appliance must be disconnected from the
supply mains.
Operaon Instrucons
Before the rst operaon, put unit under the room temperature for half of an hour before
operate.
It is recommended to use the unit under temperature of 20°C, in relave humidity less than
80%RH.
Use only clear water not over 40°C.
Check the water basin, make sure it is clear.
Operang Instrucons
1.Put the machine on a at surface.
2.Fill the water into the water tank, and then ghten the tank cover.

I
WHC750 User Manual 7
3.Put the water tank on the main body.
4.Check if the rated voltage meets the input voltage, and plug in the socket.
5.Switch on the machine; the background light of LED will be on. The machine begins to
work.
6.Touch the symbol “MAX-MIN”, you may adjust the mist volume. On the remote control,
just press the buon of “MIST VOLUME”.
7.Touch the symbol “OZONE”, the ozone generator works. On the LED display, it shows the
shape of trees. Touch again to stop the funcon.
8.Touch the symbol “HEATING”, the warm mist will come out aer 10 minutes. On the LED
display, it shows the shape of re. Touch again to stop the funcon. Mist will become cool.
9.Constant humidity: Before you touch the symbol “HUMIDITY”, LED display shows the
current humidity. You may set the humidity arranged from 45%RH to 90%RH. Press once,
it will increase by 5%RH. When it reaches 90%RH, press again, it will back to 45%RH. Aer
you set the expected humidity, the machine will keep the memory aer 5 seconds. 5
seconds later, LED display shows the current humidity. If the expected humidity is less than
the current humidity, the machine will be in sleeping state. But if the expected humidity is
higher than the current humidity, the humidify funcon will work.
10.Timer seng: There are 12 mer seng: 1,2,3,4,5,6,7,8,9,10,11,12 hours. Touch the
symbol “TIMER”, LED display shows the mer. The mer shows the rest operaon me
and decrease by 1 hours, i.e., if set the mer at 12 hours, LED display shows 11 aer one
hour. Once you have set the mer, the value of me remaining in mer and the room
temperature will display 30 seconds alternang in the middle of LED display.
1.Once the water in the basin is too lile to keep the machine working, the machine will
automacally stop working. LED shows the shape of lack of water. Rell the water, and the
machine will restart.

IWHC750 User Manual8
Control Buons
LCD DISPLAY

I
WHC750 User Manual 9
Trouble Shoong Guide
Any trouble found in normal operaon, please kindly refer to the following points:
Trouble Possible reasons Shoong Way
Power lamp o, does
not work
No power supply Connect power supply,
switch on
Power lamp on, no
mist outlet with wind
No water in water tank Fill water into water tank
Security switch is too slight Make the switch ght
Abnormal smell mist New unit Take out water tank,
open cover, let it stay 12
hours in cool posion
Dirty water or long me
staying water
Cleaning water tank, ll
in clear water
Power lamp on, unit
doesn’t work
Too much water in the
water basin
Pull out same water from
the water basin, closed
the cover of water tank
ghtly
Mist fog is too small Too much scale in the water
basin
Clean transducer
Water is too dirty or water
kept too long in the tank
Clean water tank, change
to fresh clear water
Abnormal noise Resonant in water tank
when water is too less
Fill water into water tank
Unit is on a unstable surface Move the unit to a stable
at surface
Mist fog coming out
from around nozzle
There are gaps between the
nozzle and water tank
Dip the nozzle in water
for a while and then x
it to the socket on water
tank
Maintenance:
In case when the water is hard which means water contains too much calcium and
magnesium, they can cause “white powder” problem and give limes on the surface of water
basin, transducer and inner surface of the water tank. Limes on the surface of transducer
will unable the unit work properly.
We recommend:
1.Use cold boiled water or dislled water.
2.Clean the transducer, water tank and basin unit every week.
3.Change the water in water tank more oen to keep it fresh.
4.Make sure to pull out the water from the water tank and dry the water basin before you
store the unit unused for a long period of me.
5.Clean the whole unit, and make sure that all parts of the unit are dried completely before
unused for a long period of me.

IWHC750 User Manual10
How To Clean The Filter System
Method A
1.Clean and acvate the ceramic balls aer use of 1000L water regularly.
2.Take the lter system away from the tank cover.
3.Put the lter system into the white vinegar for about 10 minutes.
4.Take the lter system away from the white vinegar; shake for several mes, clean it with
clear water.
5.Make it dry. Pack it into a polybag. Keep it in a cool and shady place.
Method B
1.Clean and acvate the ceramic balls aer use of 1000L water regularly.
2.Take the lter system away from the tank cover.
3.Put out the ceramic balls and clean it with clear water.
4.Sun them for several hours under sunshine.
5.Put ceramic balls back to lter cartridge.
6.Pack it into a polybag. Keep it in a cool and shady place.
How to clean the transducer
1.Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes;
2.Brush out the scale on the surface.
3.Rinse the transducer with clean water.
How to clean the basin unit
1.Cleaning the water basin with so cloth and the cleaning abluent if there is scale in it.
2.If the scale is covered on the security switch, drop the cleaning abluent on the scale and
clean it out with the brush.
3.Rinsing the water basin with clean water.

I
WHC750 User Manual 11
Technical Data
Model: WHC750
Power supply: 220-240V 50Hz
Heang power: 100W
Humidify power: 30W
Total power: 130W
Water tank capacity: 5L
Evaporaon Rate: ≥250ml/H
Noise level: ≤35dB(A)
Ozone concentraon: ≤0.05 PPM
DISPOSAL: Do not dispose this product as unsorted municipal waste, collecon of
such waste separately for special treatment is necessary.

I1
WHC750 Mode D’emploi
Table Des Maères
Principe De Fonconnement...................................................................................2
Caractérisques......................................................................................................3
Foncons................................................................................................................3
Instrucons De Sécurité...........................................................................................4
Instrucons Pour L’ulısaon..................................................................................5
Guide De Dépannage...............................................................................................7
Entreen................................................................................................................8
NousRecommandons..............................................................................................8
Comment Neoyer Le Système De Fıltraon...........................................................8
Méthode A.............................................................................................................9
Méthode B.............................................................................................................9
Fıche Technıque......................................................................................................9

I
2WHC750 Mode D’emploi
Principe de fonconnement: L’humidicateur à ultrasons ulise l’oscillateur à haute
fréquence à ultrasons pour briser l’eau en minuscules parcules d’eau avec un diamètre
d’environ 1-5um. Le système de venlaon soue cee eau dans l’air sec où elles
s’évaporent pour donner l’humidité nécessaire. Le jet de vapeur est clairement visible.

I3
WHC750 Mode D’emploi
Caractérisques
Un débit de grande capacité pour une humicaon ecace..
Faible consommaon d’énergie, économie de 85-90 pour cent d’électricité comparé à un
humidicateur à ux normal.
Longue durée de vie
Contrôle automaque du niveau d’humidité, protecon de sécurité en cas de manque
d’eau.
Foncon chauage: Appuyez sur le symbole de chauage pour émere de un jet de brume
chaude. Appuyez à nouveau pour arrêter la foncon de chauage.
Foncon puricateur d’air par Ozone (anion): Appuyez sur le symbole de l’ozone (anion)
pour diuser des éléments d’ozone puricateurs (anion). Appuyez à nouveau pour arrêter la
foncon d’Ozone (anion).
Foncons
1: Humidité relave
1. La quanté de vapeur d’eau contenue dans l’air dans un espace donné à une température
donnée, s’exprime par un pourcentage appelé humidité relave qui se note % HR.. L’air
atmosphérique conent toujours de la vapeur d’eau, le pourcentage est en foncon des
condions météorologiques. Plus la température est élevée, plus l’air mainent la vapeur
d’eau. d’air.
2. Lorsque les installaons de chauage fonconnent pour réchauer l’air froid, le taux
d’humidité relave diminue. An de maintenir un environnement confortable et sain à la
maison, nous avons besoin de plus d’eau arcielle ou de vapeur d’eau dans l’air ambiant,
c’est la foncon de l’humidicatuer
3. L’humidité relave idéale dans diérents environnements:
Le meilleur confort pour l’être humain dans une chambre à coucher est un taux RH situé
entre 45-65%

I
4WHC750 Mode D’emploi
Dans la chambre d’un paent, le taux idéal se situe entre 40-55% RH
Pour les appareils d’informaque et des télécommunicaons : 45-60% RH
Pour les meubles et instruments de musique: 40-60% RH
Pour les galerie d’art, musées et bibliothèque: 40-60% RH
2: Filtre à eau:
1. La pare en plasque est composée de diérents matériaux nano-argent pour éliminer
les bactéries.
2. Les billes en céramique servent à adoucir l’eau.
3. Le ltre céramique élimine les mauvaises odeurs dans l’eau.
Instrucons de sécurité
Aenon: veuillez lire aenvement les instrucons de sécurité suivante an d’éviter des
risques corporels ou des chocs électriques
1) Ne jamais démonter l’appareil sans consulter un professionnel qualié.
2) Si le cordon d’alimentaon est endommagé, il doit être remplacé par le fabricant, son
agent de service ou un technicien qualié an d’éviter tout danger.
3) Ne pas ajouter de détergents, de soluons chimiques qui ne sont pas fabriqués par notre
société dans l’appareil.
4) Débranchez l’appareil pendant le remplissage, le neoyage et l’entreen.
5) Stockez les détergents, et les soluons chimiques loin des enfants.
6) Ne pas modier le raccordement électrique. Toute modicaon sur l’appareil doit-être
conée à un agent agrée par notre société.
7) En cas d’odeur anormale pendant le fonconnement, veuillez éteindre et débrancher
l’alimentaon et vous adresser à un professionnel qualié.
8) Neoyez l’appareil à l’eau claire. En cas d’ulisaon de produits détergents, si ces
produits chimiques éclaboussent la bouche ou les yeux, consulter d’urgence un médecin.
9) Ne jamais toucher l’eau dans le réservoir ou les composants de l’appareil lorsqu’il est en
fonconnement.
10) Ne jamais allumer l’appareil quand il n’y a pas d’eau dans le réservoir.
11) Ne jamais graer le transducteur cpl (émeeur de vapeur).
12) Ne jamais neoyer le transducteur cpl avec des détergents ou des soluons chimiques
qui ne soient pas recommandés par notre société.
13) Evitez toute projecon d’eau à l’intérieur de l’unité de base pour éviter d’endommager
les composants.
14) Soyez très aenf au risque de brulure lors de l’ulisaon de l’appareil avec la foncon
vapeur d’eau chaude.
15) Avant le neoyage et l’entreen, l’appareil doit être déconnecté de l’alimentaon
principale.
16) Cet appareil n’est pas desné à être ulisé par des personnes (notamment des enfants)
dont les capacités physiques, sensorielles ou mentales sont réduites, ou manquant
d’expérience et de connaissances, à moins qu’elles n’aient été formées et encadrées pour
l’ulisaon de cet appareil par une personne responsable de leur sécurité.
18) Les enfants doivent être surveillés pour s’assurer qu’ils ne jouent pas avec l’appareil.
19) Ulisaon à l’intérieur seulement.
20) Avant tous travaux d’entreen ou de neoyage, l’appareil doit être débranché du réseau

I5
WHC750 Mode D’emploi
d’alimentaon.
Condions d’ulisaon
Avant la mise en marche, laissez l’appareil à la température ambiante de la pièce
d’ulisaon pendant au moins une demi-heure.
Il est recommandé d’uliser l’appareil à une température inférieure à 20 ° C, et une
humidité relave inférieure à 80% HR.
Uliser de l’eau claire ne dépassant pas les 40C.
Vériez le réservoir d’eau, assurez-vous qu’il soit propre.
Instrucons Pour L’ulisaon
1. Placez l’appareil sur une surface plane.
2. Remplissez d’eau le réservoir d’eau, puis serrer le couvercle du réservoir.
3. Mere le réservoir d’eau sur le corps principal.
4. Vériez que la tension électrique nominale corresponde à la tension d’entrée, et brancher
la prise.
5. Allumez la machine, la lumière de fond de l’écran LED s’allume. La machine commence à
travailler. NE JAMAIS FAIRE FONCTIONNER L’APPAREIL SANS EAU DANS LE RESERVOIR !
6. Eeurez le symbole «MAX-MIN» pour régler le volume de brume. Sur la télécommande,
appuyez simplement sur le bouton de «VOLUME MIST».

I
6WHC750 Mode D’emploi
7. Eeurez le symbole «OZONE» pour mere en marche le générateur d’ozone. L’écran LED
ache la forme d’un arbre. Appuyez à nouveau pour arrêter la foncon.
8. Eeurez le symbole «CHAUFFAGE», la brume chaude sorra au bout de 10 minutes.
L’écran LED ache un symbole de feu. Appuyez à nouveau pour arrêter la foncon. La
brume deviendra fraîche.
9. Humidité constante: Avant de toucher le symbole «HUMIDITE», l’achage LED indique
l’humidité actuelle. Vous pouvez régler le taux d’humidité souhaité de 45% RH à 90%
RH. Appuyez une fois, le taux aché va augmenter de 5% RH. Quand il aeint 90% HR,
appuyez à nouveau, il sera de retour à 45% d’humidité relave. Après avoir déni l’humidité
aendue, l’appareil le conserve en mémoire après 5 secondes. 5 secondes plus tard,
l’achage LED indique l’humidité actuelle. Si l’humidité aendue est inférieure à l’humidité
actuelle, la machine sera en état de veille. Mais si l’objecf d’humidité programmées plus
élevé que l’humidité actuelle, la foncon d’humidicaon se mera en marche jusqu’à
obtenon du taux souhaité.
10. Réglage de la minuterie: Il y a 12 réglage de la minuterie: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10,
11, 12 heures. Eeurez le symbole «MINUTERIE», l’achage LED indique la minuterie.
Le chronomètre ache le temps de fonconnement restant. Si on règle la minuterie
à 12 heures, l’achage LED indique 11 après une heure. Une fois que vous avez réglé
la minuterie, le temps de minuterie restant et la température ambiante s’achent 30
secondes en alternance.
11. Lorsque qu’il n’y a plus susamment d’eau dans le réservoir, l’appareil cesse
automaquement de fonconner. L’écran LED ache un symbole de manque d’eau.
Rajouter de l’eau, et la machine redémarrera.

I7
WHC750 Mode D’emploi
Guide de dépannage
En cas de problème rencontré avec l’appareil, merci de vous référez au tableau ci-dessous:
Problème Raisons possibles Mode de dépannage
Témoin d’alimentaon
éteint, pas de
fonconnement
Pas d’alimentaon de
courant
Connectez l’alimentaon,
allumez
Témoin d’alimentaon
allumé, pas de jet de brume
Pas d’eau dans le
réservoir d’eau
Remplissez le réservoir
d’eau
Interrupteur de sécurité
est trop faible
Ajustez l’interrupteur de
sécurité
Odeur anormale en
fonconnement
Appareil neuf rerez le réservoir d’eau,
ouvrez le couvercle,
laissez le réservoir
pendant 12 heures à l’air
frais.
Eau sale ou qui a
longtemps séjourné dans
le réservoir
Neoyez le réservoir
d’eau, remplissez le d’eau
claire
Témoin d’alimentaon
allumé, l’unité ne
fonconne pas
Trop d’eau dans le
réservoir d’eau
Rerez un peu d’eau du
réservoir et refermez-le

I
8WHC750 Mode D’emploi
Le jet de brume est réduit Réservoir d’eau encrassé Neoyez le transducteur
Eau sale ou qui a
longtemps séjourné dans
le réservoir
Neoyez le réservoir
d’eau, remplissage à l’eau
claire
Bruit anormal Résonance dans le
réservoir d’eau lorsque
qu’il en manque
Remplissez le réservoir
d’eau
L’unité est posée sur une
surface instable
Déplacer l’appareil sur
une surface plane et
stable
Le jet de brume sort
d’autour de la buse
Il y a des ouvertures entre
la buse et le réservoir
d’eau
Plongez la buse dans
l’eau pendant un certain
temps et puis rexez la
sur le réservoir
Entreen
Dans le cas où l’eau est dure c’est-à-dire qu’elle conent trop de calcium et de magnésium,
cela peut provoquer un problème de «poudre blanche» et former des dépôts de calcaire à
la surface du réservoir d’eau, du transducteur et sur la face intérieure du réservoir d’eau. Le
dépôt sur la surface du capteur empêcheront l’unité de fonconner correctement.
Nous recommandons
1) Ulisez de l’eau bouillie froide ou de l’eau disllée.
2) Neoyer le capteur, le réservoir d’eau et l’unité du réservoir chaque semaine.
3) Changez l’eau dans le réservoir d’eau plus souvent pour le garder propre.
4) Assurez-vous de rerer l’eau du réservoir d’eau et sécher le bassin d’eau avant de ranger
l’appareil qui n’est pas ulisé pendant une longue période de temps.
5) Neoyer l’unité enère, et assurez-vous que toutes les pièces de l’appareil soient
complètement séchées avant d’être inulisées pendant une longue période de temps.
Comment Neoyer Le Système De Filtraon

I9
WHC750 Mode D’emploi
Méthode A
1. Neoyer et acver régulièrement les billes en céramique après consommaon de 1000 L
d’eau.
2. Séparez le système de ltraon du couvercle du réservoir.
3. Meez le système de ltraon dans le vinaigre blanc pendant environ 10 minutes.
4. Rerez le système de ltraon du vinaigre blanc et agiter à plusieurs reprises, neoyer
avec de l’eau claire.
5. Faire sécher. Emballez-le dans un sachet. Gardez-le dans un endroit frais et ombragé.
Méthode B
1. Neoyer et acver régulièrement les billes en céramique après consommaon de 1000 L
d’eau.
2. Séparez le système de ltraon du couvercle du réservoir.
3. Sortez les billes en céramique et neoyez-les avec de l’eau claire.
4. Meez les pendant plusieurs heures sous le soleil.
5. Meez les billes en céramique de nouveau dans le ltre à cartouche.
6. Emballez-le dans un sachet. Gardez-le dans un endroit frais et ombragé.
Comment neoyer le transducteur:
1) Meez 5-10 goues de vinaigre blanc sur la surface du capteur, aendre 2-5 minutes;
2) Brossez le dépôt sur la surface.
3) Rincez la sonde avec de l’eau propre.
Comment neoyer le bassin de l’unité :
1) Neoyez le bassin d’eau avec un ssu souple et un peu de vinaigre blanc en cas de trace
de dépôt de calcaire.
2) En cas de dépôt sur l’interrupteur, meez un peu de vinaigre blanc et brossez légèrement.
3) Rincez le réservoir d’eau avec de l’eau propre.
Fiche Technique
Modèle: WHC750
Alimentaon électrique: 220-240V 50Hz
Puissance de chauage: 100W
Puissance d’humidicateur: 30W
Puissance totale: 130W
Capacité réservoir d’eau: 5L
Taux d’évaporaon: ≥ 250 ml / H
Niveau sonore: ≤ 35 dB (A)
Concentraon d’ozone: ≤ 0,05 ppm
ÉLIMINATION: Ne pas jeter ce produit avec les ordures ménagères, collectez ces
ordures pour un traitement adapté si nécessaire.
Other manuals for WHC 750
1
Table of contents
Languages:
Other weewell Humidifier manuals

weewell
weewell WHC726 User manual

weewell
weewell WHC 714 User manual

weewell
weewell WHC660 User manual

weewell
weewell WHC640 User manual

weewell
weewell WHC 750 User manual

weewell
weewell WHC 752 User manual

weewell
weewell WHC740 User manual

weewell
weewell WHC650 User manual

weewell
weewell WHC730 User manual