Welch Allyn LX-150 User manual

Ught
S
ource
Menu
Service
Manual
Int'l
Manual
Welch
Allyn
LX-150"
Light
Source
Operating
Instructions

ww
Welch
Allyn
Thank
you
for
purchasing
the
Welch
Allyn
LX-150
Light
Source.
The
operating
and
maintenance
instructions
found
in
this
manual
should
be
followed
to
ensure
many
years
of
accurate
and
reliable
service.
Please
read
these
instructions
thoroughly
before
using
your
new
LX-150
Light
Source.
Warning
The
user
of
this
equipment
should
be
thoroughly
trained
in
the
medical
procedures
appropriate
to
the
instrumentation.
Further¬
more,
time
should
be
taken
to
read
and
understand
these
instruc¬
tions
before
performing
any
procedures.
Instructions
for
other
equipment
used
in
conjunction
(e.g.
electrosurgical
generators,
suction
machines,
etc.)
should
also
be
read
and
understood.
Failure
to
do
so
may
result
in
injury
to
the
patient
and/or
damage
to
the
instrument.

Specifications
Illumination
Lamp
Type
Lamp
Life
Brightness
Adjustment
Cooling
Method
150w
Halogen
(#04050)
50
Hours
Continuous
Diaphragm
Forced
Air
Air
Feeding
Pump
Type
Capacity
Max.
Flow
Rate
Control
Electromagnetic
Vibrator
6.6
p.s.i.
Max.
7.2
UMin.
Independent
Air
Switch
Dimensions
Weight
(W)11"
X
(H)51/2"
X
(D)9V2"
17.5
lbs.
Supply
Circuit
Voltage
Frequency
Current
115v
A.C.
±
10%
60Hz
2A
Ambient
Temp
lO^O'-C
Relative
Humidity
1

Nomenclature
1.
Main
Power
Switch-controls
all
power
into
light
source.
Without
activation,
all
other
controls
will
not
function.
2.
Air
Feed
Switch-activates
flow
of
air
at
air
output
connector
(on
right
side
of
box).
3.
Illumination
Control-controls
intensity
of
light
output
at
endoscope
connector
port.
4.
Endoscope
Connector
Port-accepts
endoscope
connector
terminal
of
endoscope
to
complete
illumination
pathway.
5.
Water
Bottle
Bracket-couples
water
bottle
to
light
source.
6.
Air
Output
Connector-couples
to
air
input
hose
on
water
bottle.
7.
Lamp
Access
Door-opens
to
allow
for
lamp
replacement.

Bottom
View
Water
Bottle
8.
Air
Input
Hose-couples
to
light
source
air
output
connector.
9.
Air/Water
Output-couples
to
dual
lumen
air/water
line
of
flexible
sigmoidoscope
(FX-100).
10.
Mounting
Bracket-couples
to
water
bottle
bracket
on
light
source
to
support
bottle.

Prior
to
Initial
Use
General
Precautions
.
The
cabinet
of
this
unit
should
always
be
grounded
correctly
and
securely
during
use.
Do
not
disable
the
line
cord
ground
connection.
.
LX-150
should
not
be
used
in
the
presence
of
any
flammable
gas.
.
The
LX-150
and
connected
endoscope
should
not
be
used
with
electrosurgical
instruments
that
exceed
safety
leakage
current
or
whose
safety
in
linkage
is
not
guaranteed.
.
Immediately
stop
using
the
light
source
if
liquid
enters
the
cabinet.
.
Do
not
look
directly
into
endoscope
connector
port
when
it
is
emitting
light.
Preparation
for
Use
.
The
light
source
should
be
set
upon
a
firm,
horizontal
surface.
Care
must
be
exercised
to
keep
both
sides
of
the
illuminator
free
of
obstructions
to
permit
efficient
circulation
of
air.
Connection
to
Supply
Source
*
Check
to
verify
that
the
power
switch
is
off.
.
Couple
the
supply
cord
to
a
115v/60Hz
hospital
grade
receptacle
that
meets
the
input
ratings
on
the
rating
plate.
Connecting
Endoscope
.
Insert
the
endoscope
connector
terminal
into
the
endoscope
connector
terminal
port.
(Note:
Endoscope
alignment
pin
should
point
toward
the
bottom
of
the
light
source).
.
Push
the
terminal
firmly
into
the
port
until
it
“clicks”
into
place.
Connecting
Water
Bottle
.
Remove
cap
and
fill
the
water
bottle
with
clean
tap
water
until
314
full.
.
Replace
cap
and
tighten
firmly.
.
Hook
water
bottle
to
bracket
on
right
side
of
light
source.
(Note:
DO
NOT
attempt
to
fill
water
bottle
while
it
is
connected
to
light
source.)
.
Couple
air
output
connector
hose
to
air
output
connector
on
light
source.
.
Couple
dual
lumen
air/water
line
to
top
of
water
bottle.
Connect
remaining
fittings
to
corresponding
air/water
input
connectors
on
endoscope.
4

Inspection
Prior
to
every
examination,
the
equipment
should
be
pre-tested
following
the
procedures
outlined
below.
If
an
abnormality
is
detected
or
suspected,
contact
Welch
Allyn
Customer
Service
for
assistance.
Activating
Light
Source
*
Switch
power
switch
to
“on”.
.
Set
brightness
knob
midway
between
(-
1
-)
and
(-)
settings.
.
Check
the
distal
tip
of
endoscope
to
verify
that
light
is
being
emitted
from
distal
light
guides.
.
Verify
that
internal
cooling
fan
is
operating
by
listening
to
whirring
noise
from
light
source.
.
If
unit
does
not
power
up,
contact
Welch
Allyn
Customer
Service
(315)
685-4560.
.
If
fan
is
activated
but
no
light
is
emitted,
lamp
is
defective.
Refer
to
maintenance
section
for
replacement
procedure.
Adjusting
Light
Intensity
.
Light
emitted
from
the
distal
tip
of
the
endoscope
will
increase
as
the
brightness
knob
is
rotated
toward
the
(
+
)
and
conversely
the
intensity
will
diminish
when
rotated
toward
(-).
Air/Water
Feed
.
With
power
switch
“on”,
turn
on
the
air
switch.
.
Verify
that
air
and
water
flow
normally
from
distal
tip
of
endoscope
when
corresponding
valves
are
depressed.
NOTE:
If
air/water
flow
falls
below
normal,
contact
Welch
Allyn
Customer
Service.
Storage
.
Disconnect
and
empty
the
water
bottle.
Wash
with
mild
soapy
water
and
rinse.
.
Disconnect
power
cord
from
receptacle.
.
Wipe
external
surface
of
source
and
power
cord
with
gauze
moistened
in
alcohol.
.
Store
in
a
clean,
dust-free
environment
at
room
temperature.
Avoid
direct
sunlight
and
areas
of
high
temperature/humidity.
.
Do
not
wind
power
cord
so
tightly
that
it
will
crush,
twist
or
bend.
5

Maintenance
Lamp
Replacement
1.
Turn
power
switch
to
“off”
position
and
unpiug
power
cord
from
receptacie.
2.
Uncoupie
air
input
hose
and
remove
water
bottie
from
bracket.
3.
Fiip
the
iight
source
180°
and
piace
top
face
down
on
a
horizontai
surface.
4.
Open
iamp
access
door
by
inserting
a
coin
in
siot
and
turning
reiease
iatch
1/4
turn
counterciockwise.
(Note:
before
touching
iamp,
aiiow
for
sufficient
time
to
cooi.)
5.
After
iamp
has
cooied,
puii
the
iamp
hoiding
iever
toward
the
back
of
the
unit
untii
the
iever
reaches
an
aimost
verticai
position.
6.
Remove
expired
iamp
from
the
iamp
hoider.
7.
Prior
to
instaiiing
new
iamp,
remove
protective
cap.
8.
Return
the
iever
to
its
originai
position.
The
new
iamp
may
then
be
inserted
into
the
hoider
and
advanced
untii
it
“snaps”
into
piace.
(Note:
iamp
must
be
fuiiy
inserted
to
assure
proper
contact).
9.
Ciose
and
secure
iamp
access
door.
(Note:
Use
repiacement
iamp
#04050)
Service
For
service,
ship
iight
source
to:
For
assistance,
teiephone:
Weich
Aiiyn
Customer
Service
(315)
685-4560
Welch
Allyn
Welch
Allyn,
Inc.
4341
State
Street
Road
Skaneateles
Falls,
NY
13153-0220
Attention:
Repair
Department
Printed
in
U.S.A.
Part
No.
451502
Table of contents
Other Welch Allyn Power Supply manuals