Westermo LD-63 AC User manual

Linjedelare, optisk fiber
– RS-232/V.24, RS-422/485
Line sharin device, fibre optic
– RS-232/V.24, RS-422/485
Glasfaser Leitun steiler
RS-232/V.24, RS-422/485
Convertisseur Multipoint
RS232/422/485 – Fibre Optique
INSTALLATIONSANVISNING
INSTALLATION MANUAL
INSTALLATIONS ANLEITUNG
MANUEL D’INSTALLATION
6 72-2 4
www.westermo.se
LD-63 AC
LD-63 DC
©Westermo Teleindustri AB • 2000 • Rev. A
Galvanic
Isolation Transient
Protection CE
Approved

26072-2004
Specifikationer LD-63
Överföring Asynkront*, full/halv duplex eller simplex
Gränssnitt 1 EIA RS-232/ITU-T V.24
9-polig frånskiljbar skruvplint
EIA RS-422/RS-48 / ITU-T V.11
-polig frånskiljbar skruvplint
Gränssnitt 2 4 ST-kontakter, se tabell för effektbudget
Överföringshastighet Upp till 11 ,2 kbit/s (RS-232)
Upp till 1, Mbit/s (RS-422/48 )
Lysdioder Power, TD, RD, TX1, TX2, RX1, RX2
Temperaturområde – 0°C, omgivningstemperatur
Fuktighetsområde 0–9 % RH utan kondensation
Mått x100x128 mm (BxHxD)
Vikt 0,6 kg AC / 0,3 kg DC
Montering På 3 mm DIN-skena
Matningsalternativ
Funktionsbeskrivning LD-63
LD-63 är en linjedelare som möjliggör att bygga upp ett multidropp-nät via fiber där den
anslutna utrustningen antingen kan ha RS-422/48 eller RS-232/V.24 .
Modemet består av 2 fiberkanaler med en sändare respektive mottagare för vardera
kanalen TX1, TX2, RX1 och RX2. På frontpanelen finns dessutom 7 st lysdioder som ger
indikering av datatrafiken på kanalerna. De båda fiberkanalernas ingångar är transparanta
vilket betyder att inkommande data på RX1 ej kodas av utan sänds vidare av TX2 och
inkommande data på RX2 sänds vidare av TX1. LD-63 gör det möjligt att sända och ta
emot RS422/48 och RS-232/V.24, men inkommande data på gränssnitten kommer att
överlagras om data sänds samtidigt till gränssnitt RS-232/V.24 och RS-422/48 .
Antalet LD-63 som kan seriekopplas är begränsat. Se tabell sid 4.
* Synkront protokoll kan överföras under vissa förutsättningar.
Se beskrivning ”Val av antal bitar” sid 4.
Modellbeteckning LD-63 LD-63 LD-63 LD-63 LD-63
AC 11 V AC DC 36– V DC HV
Strömförsörjning 230V AC 11 V AC 24V DC 48V DC 9 –240 V AC±10%
+1 /–10% +1 /–10% + 0/– 0% +1 /–2 % 110–240 V AC±10%
Frekvens 48–62Hz 48–62Hz – – 48–62Hz / –
Säkring, F2 100mA S 100mA S 1,6A S 1,6A S 1A T Wickmann
x20 mm x20 mm x20 mm x20 mm
Littelfuse Littelfuse Littelfuse Littelfuse
Effektförbrukning 20mA 40mA 3W 3W 40mA
Isolationsspänning 3 000V 3 000V 1 00V 1 00V 3 7 0V
RMS

36072-2004
0/12 16,6 dB 14,6 dB
62, /12 18,6 dB 1 ,1 dB
100/140 2 ,9 dB
9/12 12,3 dB
0/12 µm 3,0 dB/km 1,0 dB/km
62, /12 µm 3, dB/km 1,2 dB/km
100/140 µm 4,0 dB/km
9/12 µm 0, dB/km
Fiber Dämpning
vid 82 nm
Dämpning
vid 13 nm
Dämpning
vid singelmod (13 nm)
0/12 10,7 dB 8,1 dB
62, /12 14, dB 11,6 dB
100/140 20,6 dB
9/12 6,3 dB
Enhet
82 nm 13 nm singelmod
Enhet
82 nm 13 nm singelmod
Min. budget Typ. budget
Effektbudget
Förluster i fiberoptisk kabel
Nedan angivna värden kan variera beroende på kvalité och fabrikat på den fiberoptiska
kabeln.
Förluster i kontakter Förluster i skarv
0,2–0,4 dB Svetsad 0,1 dB
Mekanisk 0,2 dB
”Min. budget” anger garanterat minsta effektbudget. Erfarenheten visar dock att värdet oftast ligger i
nivå med angivet ”Typ. budget”.
Fiber
Fiber

Möjlig
retiming
46072-2004
Överföringshastighet/Vändtid/
Antal enheter i serie
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
20
Antal*
enheter
20
20
20
20
20
20
20
20
1
10
20
10
4
S1
ON
1234 6789
Val av V eller Y funktion
Y
S1
ON
1234 6789
V
S1
ON
1234 6789
Val av retiming funktion
Retiming
S1
ON
1234 6789
Retiming av
S1
ON
1234 6789
Val av antal bitar
9
S1
ON
1234 6789
10
S1
ON
1234 6789
11
S1
ON
1234 6789
*
S1
ON
1234 6789
V-funktion respektive Y-funktion enligt bild sid 5.
Inställningar LD-63
0,4 ms 2 400 bit/s
Vänd-
tid Överförings-
hastighet
0,2 ms 4 800 bit/s
0,1 ms 9 600 bit/s
7 µs 14 400 bit/s
0 µs 19 200 bit/s
37 µs 28 800 bit/s
2 µs 38 400 bit/s
16 µs 62 00 bit/s
11 µs 93 7 0 bit/s
9 µs 11 ,2 kbit/s
6 µs 187, kbit/s
3 µs 37 kbit/s
2 µs 00 kbit/s
1 µs 1,0 Mbit/s
0,7 µs 1, Mbit/s
*) nvänd denna inställning för synkrona
protokoll. Sändaren är aktiv fr o m
första databiten till 10 bittider efter
den sista höga databiten (se exempel
nedan). Hastigheten ställs till
≅
10 ggr
den önskade kommunikationshastig-
heten.
Vid användande av RS-232 är det inte nödvändi t att
konfi urera antal bitar samt överförin shasti het.
RS-232 ränssnittet kan hantera överförin shasti heter
från 0 upp till 115,2 kbit/s.
Retiming funktionen beräknar exakt bitlängd
utgående från inställd hastighet och återskapar
därifrån signalen vilket gör att fler enheter kan
kopplas i serie. Retiming fungerar endast för
angivna hastigheter. För ej angivna hastigheter
( t ex 1,2 Mbit/s) ska retiming inte användas.
*) För ett större
antal enheter
kontakta Westermo
Startbit
1 bit = 52µs
1 bit:1/19 200 = 52µs
Överföringshastighet 19 200
Sändare aktiv
Ställ hastigheten till 187,5 kbit/s
10x52µs = 520µs
↵
Exempel 19 200 bit/s

••• •
•• • •
•••
••• •
•••
•••
10 10 10 11 11 119
Översiktstabell vid val av databitar
7 bitar
8 bitar
Ingen paritet
Paritet
1 stopp bit
2 stopp bitar
Antal bitar
56072-2004
Terminering med fail-safe
Terminerad (2-tråd)
S2
Terminerad (4-tråd)
S2
Ingen terminering
S2
Uteffekt kanal 1
Låg
S2
Hög
S2
Uteffekt kanal 2
Låg
Fail-safe funktionen gör att mottagaren alltid uppfattar
signaltillståndet OFF då inkopplad sändare har tillståndet
tri-state (sändare ej aktiverad).
Terminering skall kopplas in på mottagaren belägen längst
bort från sändaren.
S3
Hög
S3
ON
1234
ON
1234
123456789
S2:1-5
S1:1-9
S3:4-1
ON
1234
ON
1234
Fabriksinställning
S1
ON
1234 6789
S3
ON
1234
S2
ON
1234
Val av 2- eller 4-tråd
4-tråd
S1
ON
1234 6789
2-tråd
S1
ON
1234 6789
Val av 2-tråd RS-485 eller 4-tråd RS-422.
Vid RS-232/V.24 används inte S1:1.
ON
1234
1234
ON
1234
ON
Beskrivning V/Y-funktion
LA-01Y
OR
OR
OR
LA-01V
OR
F/O
V-funktion
kanal 1 kanal 2
kanal 1 kanal 2
Y-funktion
F/O
F/O F/O
RS-232/V.24 / RS-422/48
RS-232/V.24 / RS-422/48
Normalt används hög uteffekt. Låg uteffekt används vid
fiberlängder under 100 meter.
Normalt används hög uteffekt. Låg uteffekt används vid
fiberlängder under 100 meter. S3: 2–4 används ej.

Anslutnings- Spännings-
nr. anslutning
L 11 */230V
N AC matning
Skyddsjord
66072-2004
Anslutningar LD-63
Linjeanslutning
( -polig skruvplint)
Matningsanslutning
LD-63 DC
(2-polig skruvplint)
Terminalanslutning (DCE)
(RS-232-C/V.24, 9-polig skruvplint)
Riktning Anslutnings ITU-T V.11
nr. Benämning
Mottagare 1 A’ (R+)
Mottagare 2 B’ (R–)
Sändare 3 A (T+)
Sändare 4 B (T–)
Skärm
Riktning Skruvplint ITU-T V.24 Beskrivning
nr. Benämning
I8 103 TD/Transmitted Data
O7 104 RD/Received Data
–9 102 SG/Signal Ground
I= Ingång O= Utgång på LD-63
Anslutnings- Spännings-
nr. anslutning
1 – Spänning
2 + Spänning
Matningsanslutning
LD-63 AC
(3-polig skruvplint)
* LD-63 115V
Anslutnings- Spännings-
nr. anslutning
L + Spänning
N – Spänning
Skyddsjord
Matningsanslutning
LD-63 HV
(3-polig skruvplint)
12345 LN
LD-63
RS-422/485 POWER
R+
Rx1
Rx2
Tx1
Tx2
R- T+ T-
TD RDPWR
Lysdiodindikeringar LD-63
• PWR:Indikerar att enheten är spänningssatt.
• TD: Indikerar mottagen data på RS-232/V.24, RS-48 sidan.
• RD: Indikerar sänd data på RS-232/V.24, RS-48 sidan.
• Rx1: Indikerar mottagen data på fiberkanal 1.
• Rx2: Indikerar mottagen data på fiberkanal 2.
• Tx1: Indikerar sänd data på fiberkanal 1 från RS-232/V.24, RS-48 sidan.
• Tx2: Indikerar sänd data på fiberkanal 2 från RS-232/V.24, RS-48 sidan.
Definitionen R+/R–,T+/T–kan variera mellan olika
tillverkare.

76072-2004
RS-422/48
RS-232/V.24 eller
Anslutningsexempel
Fiberanslutning
LD-63
RX1 RX2
TX2
TX1
RX1 RX2
TX2
TX1
LD-63 LD-63
RS-422/48
RS-232/V.24 eller RS-422/48
RS-232/V.24 eller
RX1 RX2
TX2
TX1
LD-64
Rx1
Rx2
TD RD C EPWR
OPTO LINK MONITOR
Ch1 CE
Ch2
12345 LN
RS-422/485 POWER
R+
Rx2
Tx1
Tx2
R- T+ T- 12345 LN
RS-422/485 POWER
R+
Rx2
Tx1
Tx2
R- T+ T-
R+
RS-422
utrustning
R–
T+
SG TD RD
T–
RS-48
utrustning
T+T–
RS-232/V.24
utrustning
*) Benämningarna T+, T–, R+, R– är inte standardiserade och kan variera mellan olika tillverkare. Första steget vid
felsökning bör alltid vara att skifta respektive kabelpar (byt T+ med T– och/eller R+ med R–. Observera att
kablarna endast ska skiftas i ena änden.
**
OBS! När en multidroppslinga avslutas med en LD-63 och fiberparet
ansluts på kanal 2 måste S1:2 stå i läge ON (Y-funktion)
Anslutning RS-232/V.24, RS-422, RS-485

86072-2004
Specifications LD-63
Transmission Asynchronous*, full/half duplex or simplex
Interface 1 EIA RS-232/ITU-T V.24
9-position detachable screw-terminal
EIA RS-422/RS-48 /ITU-T V.11
-position detachable screw-terminal
Interface 2 4 ST-connectors, see table of power budget
Indicators Power, TD, RD, TX1, TX2, RX1, RX2
Data rates Up to 11 ,2 kbit/s (RS-232)
Up to 1. Mbit/s (RS-422/48 )
Temperature range – 0°C, ambient temperature
Humidity 0–9 % RH without condensation
Dimension x100x128 mm (WxHxD)
Weight 0.6 kg AC / 0.3 kg DC
Mounting On 3 mm DIN-rail
Power supply alternatives
Description LD-63
The LD-63 is a line splitter designed for use in multi-drop fibre optic neworks. The LD-63
allows the conversion between RS-422/48 , RS-232/V.24 and fibre optic. The LD-63 consists of
two F/O channels, each with its separate transmitter and receiver (TX1, TX2, RX1and RX2)
On the front of the unit there are seven LED’s indicating the datatransmission on the channels.
The fibre optic interface is transparent which means that data received on RX1 is retransmit-
ted on TX2 and data received on RX2 on TX1. The LD-63 allows communication on both RS-
422/48 and RS-232/V.24 but data should never be transmitted to both RS-422/48 and RS-
232/V.24 at the same time as it will be oversampled and be impossible to read correctly.
The number of LD-63’s that can be connected in series is limited. See chart on page 11.
* Synchronous protocols can be transmitted under certain circumstances.
See ”selection of bits” page 10.
Model description LD-63 LD-63 LD-63 LD-63 LD-63
AC 11 V AC DC 36– V DC HV
Power supply 230V AC 11 V AC 24V DC 48V DC 9 –240V AC±10%
+1 /–10% +1 /–10% + 0/– 0% +1 /–2 % 110–240V DC±10%
Frequency 48–62Hz 48–62Hz – – 48–62Hz / –
Fuse, F2 100mA S 100mA S 1.6A S 1.6A S 1A T Wickmann
x20 mm x20 mm x20 mm x20 mm
Littelfuse Littelfuse Littelfuse Littelfuse
Power consumption 20mA 40mA 3W 3W 40mA
Isolation
RMS 3 000V 3 000V 1 00V 1 00V 3 7 0V

96072-2004
0/12 µm 3.0 dB/km 1.0 dB/km
62. /12 µm 3. dB/km 1.2 dB/km
100/140 µm 4.0 dB/km
9/12 µm 0. dB/km
Fibre Attenuation
at 82 nm
Attenuation
at 13 nm
Attenuation
at single mode (13 nm)
Attenuation in fibre cable
The values below can differ depending on quality and manufacturer of the fibre-optic
cable.
Attenuation in connectors Attenuation in splice
0.2–0.4 dB Fusion 0.1 dB
Mechanical 0.2 dB
0/12 16.6 dB 14.6 dB
62. /12 18.6 dB 1 .1 dB
100/140 2 .9 dB
9/12 12.3 dB
0/12 10.7 dB 8.1 dB
62. /12 14. dB 11.6 dB
100/140 20.6 dB
9/12 6.3 dB
Unit
82 nm 13 nm single mode
Unit
82 nm 13 nm single mode
Min. budget Typ. budget
Power budget
”Min. budget” states the minimum guaranteed power budget. Experience shows however that the
typical value is in the range of the indicated ”Typ. budget”.
Fibre
Fibre

1 6072-2004
Selection of V or Y function
Y
S1
ON
1234 6789
V
S1
ON
1234 6789
Selection of retiming function
Retiming
S1
ON
1234 6789
Retiming of
S1
ON
1234 6789
Selection of bits
9
S1
ON
1234 6789
10
S1
ON
1234 6789
11
S1
ON
1234 6789
*
S1
ON
1234 6789
V-function and Y-function are described
on page 11.
*) Use this setting for synchronous
protocols.
The transmitter will be active from the
start bit to 10 bit-times after the last
high databit
(see example below).
The speed shall be set to
≅
10 times
the required communication speed.
The retiming function calculates the exact bit-
length based on the speed set and recreates
the signal. This allows for more units in series.
The retiming works only for the indicated
speeds. For other speeds (e g 1.2 Mbit/s)
retiming can not be used.
Start bit
1 bit = 52µs
1 bit:1/19 200 = 52µs
Data rate 19 200
Transmitter active
Set the speed to 187.5 kbit/s
10x52µs = 520µs
↵
Example 19 200 bit/s Retiming
possible
Turning/Transmission/
Number of units connected in serie
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
20
Number*
of units
20
20
20
20
20
20
20
20
1
10
20
10
4
S1
ON
1234 6789
Switch settings LD-63
0.4 ms 2 400 bit/s
Turning-
time Transmission
rate
0.2 ms 4 800 bit/s
0.1 ms 9 600 bit/s
7 µs 14 400 bit/s
0 µs 19 200 bit/s
37 µs 28 800 bit/s
2 µs 38 400 bit/s
16 µs 62 00 bit/s
11 µs 93 7 0 bit/s
9 µs 11 .2 kbit/s
6 µs 187. kbit/s
3 µs 37 kbit/s
2 µs 00 kbit/s
1 µs 1.0 Mbit/s
0,7 µs 1. Mbit/s
When usin RS-232 interface it is not necessary to
select number of bits and transmission rate. The RS-232
interface can handle transmission rates from 0 up to
115.2 kbit/s.
*) For additional units
please contact
Westermo

116072-2004
••• •
•• • •
•••
••• •
•••
•••
10 10 10 11 11 119
Supervision table when selecting data bits
7 bits
8 bits
No parity
Parity
1 stop bit
2 stop bits
Number of bits
Termination with fail-safe
Termination (2-wire)
S2
Termination (4-wire)
S2
No termination
S2
Transmitted power channel 1
Low
S2
High
S2
Transmitted power channel 2
Low
The fail-safe function forces the signal state of the
receiver to OFF when the connected
transmitter is in tri-state (transmitter inactive).
The receiver located furthest away shall be terminated.
S3
High
S3
ON
1234
ON
1234
123456789
S2:1-5
S1:1-9
S3:4-1
ON
1234
ON
1234
Factory settings
S1
ON
1234 6789
S3
ON
1234
S2
ON
1234
Selection of 2- or 4-wire
4-wire
S1
ON
1234 6789
2-wire
S1
ON
1234 6789
Selection of 2-wire RS-485 or 4-wire RS-422.
For RS-232/V.24 S1:1 can be ignored.
ON
1234
1234
ON
1234
ON
LA-01Y
OR
OR
OR
LA-01V
OR
F/O
V-function
Y-function
F/O
F/O F/O
RS-232/V.24 / RS-422/48
RS-232/V.24 / RS-422/48
channel 1 channel 2
channel 1 channel 2
Description V/Y-function
Normally high power is used. Low power is used with fibre
lengths shorter than 100 m.
Normally high power is used. Low power is used with fibre
lengths shorter than 100 m. S3: 2–4 is not used.

12 6072-2004
Connections LD-63
Line connection
( -position screw-terminal)
Terminal connection (DCE)
(RS-232-C/V.24, 9-position screw-terminal)
Direction Connection ITU-T V.11
no. Description
Receiver 1 A’ (R+)
Receiver 2 B’ (R–)
Transmitter 3 A (T+)
Transmitter 4 B (T–)
Shield
Direction Screw ITU-T V.24 Description
no. Description
I8 103 TD/Transmitted Data
O7 104 RD/Received Data
–9 102 SG/Signal Ground
I= Input O= Output on LD-63
12345 LN
LD-63
RS-422/485 POWER
R+
Rx1
Rx2
Tx1
Tx2
R- T+ T-
TD RDPWR
LEDs for indication on LD-63
• PWR: Indicates that the converter has power.
• TD: Indicates that the converter is receiving data on RS-232/V.24, RS-48 side.
• RD: Indicates that the converter is sending data on RS-232/V.24, RS-48 side.
• Rx1: Indicates received data on fiber channel 1.
• Rx2: Indicates received data on fiber channel 2.
• Tx1: Indicates that the converter is sending data on fiber channel 1 from RS-232/V.24, RS-48 side.
• Tx2: Indicates that the converter is sending data on fiber channel 2 from RS-232/V.24, RS-48 side.
The definations R+/R–,T+/T–can be various between
different manufactures.
Connection Power
no. supply
L 11 */230V
N AC power
PE/ Protective Earth
Power connection
LD-63 DC
(2-position screw-terminal)
Connection Power
no. supply
1 – Voltage
2 + Voltage
Power connection
LD-63 AC
(3-position screw-terminal)
Connection Power
no. supply
L + Voltage
N – Voltage
PE/ Protective Earth
Power connection
LD-63 HV
(3-position screw-terminal)
* LD-63 115V

LD-64
Rx1
Rx2
TD RD C EPWR
OPTO LINK MONITOR
Ch1 CE
Ch2
12345 LN
RS-422/485 POWER
R+
Rx2
Tx1
Tx2
R- T+ T-
12345 LN
RS-422/485 POWER
R+
Rx2
Tx1
Tx2
R- T+ T-
R+
RS-422
equipment
R–
T+
SG TD RD
T–
RS-48
equipment
T+T–
RS-232/V.24
equipment
*) The designations T+, T–, R+, R– are not standardised and may vary between different manufactures. The first
step in fault finding is to reverse the cables (swap T+ with T– and/or R+ with R–). Please note that this should
be done only at one end!
**
136072-2004
RS-422/48
RS-232/V.24 or
How to connect
Connection of RS-232/V.24, RS-422, RS-485
Fibre optic connection
LD-63
RX1 RX2
TX2
TX1
RX1 RX2
TX2
TX1
LD-63 LD-63
RS-422/48
RS-232/V.24 or RS-422/48
RS-232/V.24 or
RX1 RX2
TX2
TX1
NB When a multidrop connection ends with an LD-63 and the fibre pair is
connected on channel 2, the switch S1:2 must be set (Y-mode)

14 6072-2004
Technische Daten LD-63
Übertragungsarten Asynchron*, Voll-/Halbduplex oder Simplex
Schnittstelle 1 EIA RS-232-C/ITU-T V.24
9 polige Schraubklemme
EIA RS-422/RS-48 /ITU-T V.11
polige Schraubklemme
Schnittstelle 2 4 ST-Anschlüsse, siehe Tabelle Dämpfung
Leuchtdioden Betrieb, TD, RD, TX1, TX2, RX1, RX2
Übertragungsraten bis zu 11 ,2 kbit/s (RS-232)
bis zu 1, Mbit/s (RS-422/48 )
Umgebungstemperatur – 0°C
Luftfeuchtigkeit 0–9 %, nicht kondensierend
Abmessungen x100x128 mm (BxHxT)
Gewicht 0,6 Kg AC / 0,3 Kg DC
Installation auf 3 mm Din Schiene
Spannungsversorgung Alternativen
* Synchrone Protokolle können unter bestimmten Umständen übertragen werden.
Siehe ” nzahl der Bits” Seite 16.
Beschreibung LD-63
Das LD-63 ist ein Leitungsteiler der für Multidrop Glasfasernetze entwickelt wurde. Er
erlaubt die Umsetzung zwischen RS-422/48 , RS-232/V.24 und Glasfaser. Das LD-63 hat 2
Glasfaser Kanäle, jeder mit separater Sende- und Empfangseinheit (TX1,TX2, RX1 und RX2).
Auf der Frontplatte sind sieben LED’s zur Überwachung der Datenübertragung angebracht.
Die Glasfaserschnittstelle ist transparent, somit werden Daten die an RX1 empfangen wer-
den an TX2 ausgegeben, und Daten von RX2 an TX1. Das LD-63 ermöglicht die
Kommunikation mit RS-232/V.24 genauso wie mit RS-422/48 , aber die Daten können nie
gleichzeitig an beide Schnittstellen übertragen werden. Dies würde zu
Datenverstümmelungen und inkorrekten Daten führen.
Die Anzahl der in Reihe schaltbaren LD-63 ist limitiert. Siehe Umschaltzeit Seite 16
Modell Bezeichnung LD-63 LD-63 LD-63 LD-63 LD-63
AC AC 11 V DC 36– V DC HV
Spannungs- 230V AC 11 V AC 24V DC 48V DC 9 –240V AC±10%
versorgung +1 /–10% +1 /–10% + 0/– 0% +1 /–2 % 110–240V DC±10%
Frequenz 48–62Hz 48–62Hz – – 48–62Hz / –
Sicherung, F2 100mA S 100mA S 1,6A S 1,6A S 1A T Wickmann
x20 mm x20 mm x20 mm x20 mm
Littelfuse Littelfuse Littelfuse Littelfuse
Leistungsaufnahme 20mA 40mA 3W 3W 40mA
Isolationsspannung
RMS 3 000V 3 000V 1 00V 1 00V 3 7 0V

156072-2004
0/12 µm 3,0 dB/km 1,0 dB/km
62, /12 µm 3, dB/km 1,2 dB/km
100/140 µm 4,0 dB/km
9/12 µm 0, dB/km
Faser Dämpfung
bei 82 nm Dämpfung
bei 13 nm Dämpfung
bei Monomode (13 nm)
Dämpfungen in Glasfaserkabeln
Die genannten Werte können von Qualität und Hersteller des Glasfaserkabels variieren.
Dämpfung in Verbindern Spleißdämpfung
0,2–0,4 dB geschweißt 0,1 dB
mechanisch 0,2 dB
0/12 16,6 dB 14,6 dB
62, /12 18,6 dB 1 ,1 dB
100/140 2 ,9 dB
9/12 12,3 dB
0/12 10,7 dB 8,1 dB
62, /12 14, dB 11,6 dB
100/140 20,6 dB
9/12 6,3 dB
Einheit
82 nm 13 nm
Einheit
82 nm 13 nm
Min. Werte Typ. Werte
Zulässige Dämpfung
“min Werte” sind die maximal zulässigen Dämpfungen. Die Erfahrung hat jedoch gezeigt, daß die
“Typ. Werte” eher zutreffen.
Faser
Faser Mono-
mode
Mono-
mode

16 6072-2004
Das LD-63 bietet verschiedene Einstellmög-
lichkeiten zur Abstimmung auf verschieden-
ste Betriebsverhälnisse. Um die DIP-Schal-
ter einzustellen muß die Gehäuseabdeckung
z.B. mit Hilfe eines Schraubendrehers abge-
nommen werden.
Y- oder V-Betrieb
Y
S1
ON
1234 6789
V
S1
ON
1234 6789
Retiming Funktion
Retiming
S1
ON
1234 6789
Retiming AUS
S1
ON
1234 6789
Anzahl der Bits
9
S1
ON
1234 6789
10
S1
ON
1234 6789
11
S1
ON
1234 6789
*
S1
ON
1234 6789
V- und Y-Betrieb werden auf Seite 17
Beschrieben.
*) Benutzen Sie diese Einstellung für synchro-
ne und andere asynchrone Protokolle.
Der Sender ist aktiv ab dem Startbit. Nach
dem letzten Hibit bleibt er noch für 10Bit
Zeit aktiv ( siehe Beispiel). Die Geschwindig-
keit sollte etwa 10 mal höher der benötigten
Geschwindigkeit gesetzt werden.
Die Retiming Funktion berechnet die exakte
Bitlänge anhand der eingestellten Geschwindigkeit
zur Wiederherstellung der Daten. Durch sie
können mehr Geräte in Reihe geschaltet werden.
Die Funktion arbeitet nur für die gennanten
Geschwindigkeiten. Bei z.B. 1,2Mbit/s sollte sie
nicht benutzt werden.
Start Bit
1 Bit = 52µs 1 Bit:1/19 200 = 52µs
Übertragungsgeschwindigkeit 19 200
Sender aktiv für 10x52 µs = 520 µs
Wählen Sie 187,5 Kbit/s
↵
Beispiel 19 200 Bit/s
Retiming
möglich
Umschaltzeit/Übertragungsrate
Anzahl der in Serie schaltbaren Geräte
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
S1
ON
1234 6789
20
Anzahl der
Geräte
20
20
20
20
20
20
20
20
1
10
20
10
4
S1
ON
1234 6789
DIP-Schalter Einstellung
0,4 ms 2 400 bit/s
Umschalt-
zeit Übertrag-
ungsrate
0,2 ms 4 800 bit/s
0,1 ms 9 600 bit/s
7 µs 14 400 bit/s
0 µs 19 200 bit/s
37 µs 28 800 bit/s
2 µs 38 400 bit/s
16 µs 62 00 bit/s
11 µs 93 7 0 bit/s
9 µs 11 ,2 kbit/s
6 µs 187, kbit/s
3 µs 37 kbit/s
2 µs 00 kbit/s
1 µs 1,0 Mbit/s
0,7 µs 1, Mbit/s
Bei Benutzun der RS-232 Schnittstelle ist es nicht
notwendi die Anzahl der Bits und die Übertra un s-
eschwindi keit einzustellen. Die RS-232 Schnittstelle
kann von 0 bis 115.2KBit/s ein esetzt werden.
*) Fragen sie Westermo
für zusätzliche Geräte

176072-2004
••• •
•• • •
•••
••• •
•••
•••
10 10 10 11 11 119
Übersichtstabelle für Datenlänge
7 Bit
8 Bit
keine Parität
Parität
1 Stop Bit
2 Stop Bits
Anzahl der Bits
Termination mit fail-safe
2-Draht Termination
S2
4-Draht Termination
S2
keine Termination
S2
Die fail-safe Funktion zwingt den Empfänger in US-
Zustand zu gehen, wenn der angeschlossene Sender
im Tri-State Zustand ist (Sender nicht aktiv).
123456789
S2:1-5
S1:1-9
S3:4-1
Übertragungsleistung Kanal 1
niedrig
S2
hoch
S2
Übertragungsleistung Kanal 2
niedrig
S3
hoch
S3
ON
1234
ON
1234
ON
1234
ON
1234
Werkseinstellungen
S1
ON
1234 6789
S3
ON
1234
S2
ON
1234
2-/4 Draht Betrieb
4-Draht
S1
ON
1234 6789
2-Draht
S1
ON
1234 6789
Einstellung für 2-Draht RS-485 oder 4-Draht RS-422.
Bei RS-232/V.24. S1:1 nicht benutzt.
ON
1234
1234
ON
1234
ON
LA-01Y
OR
OR
OR
LA-01V
OR
F/O
V-Betrieb
Y-Betrieb
F/O
F/O F/O
RS-232/V.24 / RS-422/48
RS-232/V.24 / RS-422/48
Kanal 1 Kanal 2
Kanal 1 Kanal 2
Beschreibung V/Y-Betrieb
Normalerweise wird die Einstellung hoch benutzt. Niedrig
ist nur für Strecken kürzer als 100 m.
Normalerweise wird die Einstellung hoch benutzt. Niedrig
ist nur für Strecken kürzer als 100 m.
S3: 2–4 nicht benutzt.

18 6072-2004
Anschlüsse LD-63
Leitungsanschluß
( -polige Schraubklemme)
Anschluß RS-232-C/V.24 DÜE
(9-polige Schraubklemme)
Richtung Klemme ITU-T V.11
Nr. Bezeichnung
Empfänger 1 A’ (R+)
Empfänger 2 B’ (R-)
Sender 3 A (T+)
Sender 4 B (T-)
Schirmung
Richtung Klemme Nr.ITU-T V.24 Beschreibung
Nr. Bezeichnung
I8 103 TD/Transmitted Data
O7 104 RD/Received Data
–9 102 SG/Signal Ground
I= Eingang O= Ausgang des LD-63
12345 LN
LD-63
RS-422/485 POWER
R+
Rx1
Rx2
Tx1
Tx2
R- T+ T-
TD RDPWR
LED Anzeigen des LD-63
• PWR: Anzeige für Betriebsspannung
• TD: Datenempfang an der RS-232/V.24/RS-48 Schnittstelle
• RD: Datensendung an der RS-232/V.24/RS-48 Schnittstelle
• Rx1: Datenempfang an Glasfaserschnittstelle 1
• Rx2: Datenempfang an Glasfaserschnittstelle 2
• Tx1: RS-232/V.24/48 Datensendung auf Glasfaserschnittstelle 1
• Tx2: RS-232/V.24/48 Datensendung auf Glasfaserschnittstelle 2
Die Bezeichnungen R+/R–, T+/T– können abhängig
vom Hersteller variieren.
Klemme Spg.-Versorgung
Nr.
L 11 */230V
N AC Versorgung
PE/Schutzerde
Spannungsversorgungs
Anschluß LD-63 DC
(2-polige Schraubklemme)
Klemme Spg.-
Nr. Versorgung
1 – Pol
2 + Pol
Spannungsversorgungs
Anschluß LD-63 AC
(3-polige Schraubklemme)
Klemme Spg.-
Nr. Versorgung
L + Pol
N – Pol
PE/Schutzerde
Spannungsversorgungs
Anschluß LD-63 LV
(3-polige Schraubklemme)
* LD-63 115V

196072-2004
RS-422/48
RS-232/V.24 oder
Beispiel: Multidrop
Anschluß RS-232/V.24, RS-422, RS-485
Anschluß RS-232/V.24, RS-422, RS-485
LD-63
RX1 RX2
TX2
TX1
RX1 RX2
TX2
TX1
LD-63 LD-63
RS-422/48
RS-232/V.24 oder RS-422/48
RS-232/V.24 oder
RX1 RX2
TX2
TX1
LD-64
Rx1
Rx2
TD RD C EPWR
OPTO LINK MONITOR
Ch1 CE
Ch2
12345 LN
RS-422/485 POWER
R+
Rx2
Tx1
Tx2
R- T+ T- 12345 LN
RS-422/485 POWER
R+
Rx2
Tx1
Tx2
R- T+ T-
R+
RS-422
Ausstattung
R–
T+
SG TD RD
T–
RS-48
Ausstattung
T+T–
RS-232/V.24
Ausstattung
*) Die Bezeichnungen T+, T–, R+, R– sind kein Standard und können Herstellerabhängig variieren. Der erste
Schritt bei einer Fehlersuche ist die Leitungen zu drehen, T+ mit T– und/oder R+ mit R–. Dies sollte nur an
einem Ende getan werden.
**
Bem.: Wenn eine Multidropverbindung mit einem LD-63 endet, und die Glasfaser an
Kanal 2 angeschlossen ist, so muß der DIP Schalter S1:2 gesetzt sein (Y-Betrieb).

2 6072-2004
Spécifications LD-63
Transmission Asynchrone*, full/half duplex ou simplex
Interface 1 EIA RS-232/ITU-T V.24
Bornier à vis débrochable 9 points
EIA RS-422/48 /ITU-T V.11
Bornier à vis débrochable points
Interface 2 4 connecteurs –ST, voir le tableau du budget
fibre optique.
Vitesse Jusqu’à 11 ,2 kbits/s (RS-232-C),
Jusqu’à 1, Mbit/s (RS-422/48 )
Indicateurs LED Power, TD, RD,TX1,TX2,RX1,RX2
Gamme température – 0°C température ambiante
Humidité 0–9 % RH non condensé
Dimensions x100x128 mm (LxHxP)
Poids AC 0,6 kg / DC 0,3 kg
Fixation Sur Rail DIN 3 mm
Tableau des différentes versions d’alimentation
Description fonctionnelle LD-63
Le LD-63 est un convertisseur fibre optique à partage de ligne permettant de réaliser un
réseau fibre optique multipoint. Le LD-63 effectue la conversion entre l’interface RS-232/V.24,
RS-422/48 et la fibre optique. Le LD-63 possède deux canaux fibre optique constitué chacun
d’une voie émission et réception séparée (TX1,TX2 et RX1,RX2).Sept LED sont disposées en
face avant pour indiquer l’état des différents ports de communication.
L’interface fibre optique est transparente, cela signifie que chaque donnée reçue sur RX1 est
re-transmise sur TX2 et, de même, pour les données reçues sur RX2 vers TX1. Le LD-63
permet de communiquer globalement sur les ports RS-232/V.24 et RS-422/48 mais les don-
nées ne pourront jamais être transmises simultanément sur ces 2 ports. Il en résulterait une
saturation de l’interface dont la lecture serait impossible.
Le nombre total de LD-63 pouvant être connectés simultanément est limité. Se reporter à la
page 22
* Les protocoles Synchrones peuvent être transmis dans certaines conditions.
voir Page 4 « sélection des bits »
Référence Modèle LD-63 LD-63 LD-63 LD-63 LD-63
AC 11 V AC DC 36– V DC HV
Tension 230V AC 11 V AC 24V DC 48V DC 9 –240V AC±10%
d’alimentation +1 /–10% +1 /–10% + 0/– 0% +1 /–2 % 110–240V DC±10%
Fréquence 48–62Hz 48–62Hz – – 48–62Hz / –
Fusible, F2 100mA S 100mA S 1,6A S 1,6A S 1A T Wickmann
x20 mm x20 mm x20 mm x20 mm
Littelfuse Littelfuse Littelfuse Littelfuse
Consommation 20mA 40mA 3W 3W 40mA
Isolation
RMS 3 000V 3 000V 1 00V 1 00V 3 7 0V
This manual suits for next models
1
Table of contents
Languages:
Popular Cables And Connectors manuals by other brands

HSS Hire
HSS Hire Hire-Weld HW890 Operating & safety guide

Altronix
Altronix eBridge100RMT Kit installation guide

Colorado Video
Colorado Video 613gs instruction manual

Leviton
Leviton black & white 3762 installation instructions

PCB Piezotronics
PCB Piezotronics IMI SENSORS 009M205/100 Installation and operating manual

Philips
Philips 5 m SWV3304W/10 Specifications