Westermo Viper-012 User manual

www.westermo.com
Viper-012
Unmanaged EN 50155 Switch

26641-22410

3
6641-22410
General information
Legal information
The contents of this document are provided “as is”. Except as required by applicable law,
no warranties of any kind are made in relation to the accuracy and reliability or contents
of this document, either expressed or implied, including but not limited to the implied
warranties of merchantability and fitness for a particular purpose. Westermo reserves
the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income
or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at www.westermo.com

46641-22410
Safety and Regulations
Warning signs are provided to prevent personal injury and/or damages to the product.
The following levels are used:
Level of warning Description Consequence
personal injury
Consequence
material damage
WARNING
Indicates a potentially
hazardous situation
Possible death or
major injury
Major damage to the
product
CAUTION
Indicates a potentially
hazardous situation
Minor or moderate
injury
Moderate damage to
the product
NOTICE
Provides information
in order to avoid
misuse of the
product, confusion or
misunderstanding
No personal injury Minor damage to the
product
NOTE
Used for highlighting
general, but important
information
No personal injury Minor damage to the
product

5
6641-22410
Before installation:
Read this manual completely and gather all information on the product. Make sure that
you understand it fully. Check that your application does not exceed the safe operating
specifications for this product.
WARNING - SAFETY DURING INSTALLATION
The product must be installed by qualified service personnel
and built in to an apparatus cabinet or similar, where access is
restricted to service personnel only.
During installation, ensure a protective earthing conductor is
first connected to the protective earthing terminal (only valid for
metallic housings). Westermo recommends a cross-sectional area
of at least 4 mm2.
Upon removal of the product, ensure that the protective earthing
conductor is disconnected last.
WARNING - HAZARDOUS VOLTAGE
Do not open an energized product. Hazardous voltage may occur
when connected to a power supply.
WARNING - PROTECTIVE FUSE
The power supply wiring must be sufficiently fused.
It must be possible to disconnect manually from the power supply.
Ensure compliance to national installation regulations.
This product has no internal fuse and should be connected via an
external fuse for protection.
WARNING - REDUCE THE RISK OF FIRE
To reduce the risk of fire, use only telecommunication line cords
with a cable diameter of AWG 26 or larger. Regarding power
cable dimensions, see Interface Specifications.

66641-22410
CAUTION - HOT SURFACE
Be aware that the surface of this product may become hot.
When it is operated at high temperatures, the external surface
may exceed Touch Temperature Limit according to the product's
relevant electrical safety standard.
CAUTION - ELECTROSTATIC DISCHARGE (ESD)
Prevent electrostatic discharge damages to internal electronic
parts by discharging your body to a grounding point (e.g. use a
wrist strap).

7
6641-22410
Care recommendations
Follow the care recommendations below to maintain full operation of product and to
fulfill the warranty obligations:
• Do not drop, knock or shake the product. Rough handling above the specification
may cause damage to internal circuit boards.
• Use a dry or slightly water-damp cloth to clean the product. Do not use harsh
chemicals, cleaning solvents or strong detergents.
• Do not paint the product. Paint can clog the product and prevent proper operation.
If the product is used in a manner not according to specification, the protection provided
by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo technical support.
Product disposal
This symbol means that the product shall not be treated
as unsorted municipal waste when disposing of it. It needs
to be handed over to an applicable collection point for
recycling electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will
help to reduce hazardous substances and prevent potential
negative consequences to both environment and human
health, which could be caused by inappropriate disposal.
Declaration of Conformity
Hereby, Westermo declares that this product is in compliance with applicable EU
directives and UK legislations. The full declaration of conformity and other detailed
information is available at www.westermo.com/support/product-support.

86641-22410
Agency approvals and standards compliance
Type Approval / Compliance
EMC EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrialokokvironments
EN 61000-6-3, Emission residential environments
EN 61000-6-4, Emission industrial environments
EN 50121-3-2, Railway applications – Rolling stock – apparatus
EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus
Environmental EN 61373, Railway applications – Rolling stock equipment. Shock and vibration tests
IEEE 1478, Environmental conditions for transit rail car electronic equipment
EN 50124-1, Railway applications – Insulation coordination
EN 50155, Railway applications – Electronic equipment used on rolling stock
IEC 60068-2-27, (shock 100g, 6 ms, halfsine)
EN 45545-2, Fire safety standard
FCC Part 15.105
Notice:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful inter-
ference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
… Reorient or relocate the receiving antenna
… Increase the separation between the equipment and receiver
… Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
… Consult the dealer or an experienced radio/TV technician for help.

9
6641-22410
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
ESD EN 61000-4-2 Enclosure Contact: ±6 kV
Air: ±8 kV
Fast transients EN 61000-4-4 Power port ±5 kV
Signal ports ±2 kV
Earth port ±1 kV
Surge EN 61000-4-5 Power port L-E: ±2 kV, 12Ω, 9 μF, 1.2/50 μs
L-L: ±1 kV, 2Ω, 18 μF, 1.2/50 μs
L-E: ±2 kV, 42Ω, 0.5 μF, 1.2/50 μs
L-L: ±2 kV, 42Ω, 0.5 μF, 1.2/50 μs
L-E: ±8.4 kV, 100Ω, 0.05/0.1 μs
L-L: ±8.4 kV, 100Ω, 0.05/0.1 μs
Ethernet ports L-E: ±2 kV, 2 Ω
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50, 60 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m
Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 MHz – 2.7 GHz)
1 kHz sine, 80% AM
10 V/m @ (2.7 – 6 GHz)
1 kHz sine, 80% AM
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet ports 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission CISPR 16-2-3 Enclosure Class B (30 – 6000 GHz)
ANSI C63,4
(FCC Part 15)
Class B (30 – 6000 GHz)
Conducted RF emission CISPR 16-2-1 Power port Class B
Ethernet ports Class B
Dielectric strength EN 60950-1 Power port
to all other ports
1.5 kV ACrms, 50 Hz, 1 min
Fast Ethernet ports
to all other ports
1.5 kVACrms, 50 Hz, 1 min
Environmental
Temperatures EN 60068-2-1
EN 60068-2-2
Operating –40 to +70°C (–40 to +158°F)*
Storage and transport –50 to +85°C (–58 to +185°F)
Humidity EN 60068-2-30 Operating 5 to 95% relative humidity
Storage and transport 5 to 95% relative humidity
Altitude Operating 2 000 m / 70 kPa
Service life Operating 15 years
MTBF 636,000 hours MIL-C217F2, GB, 25°C (+77°F)
Vibration IEC 60068-2-6
(sine)
Non operating long
life simulation
7.9 m/s² (RMS) 5 – 150 Hz
IEC 60068-2-64
(random)
Operating 1 m/s² (RMS) 5 – 150 Hz
Shock IEC 60068-2-27 Operating 10 g, 30 ms, 20 g, 11 ms, 100 g, 6 ms
Bump IEC 60068-2-27 Operating 10 g, 11 ms
Enclosure Zinc Fire enclosure
Dimension W x H x D
With connectors
See "Dimensions" chapter for details
Weight 1.4 kg
Degree of protection EN 60529 Enclosure IP67**
Cooling Convection
* Refer to “Safety” section
** Provided all connectors are connected with IP67 cabling or fitted with protective caps (delivered with the unit),
tightened to the specified torque

10 6641-22410
Description
Designed for harsh industrial environments
The Viper-012 is a unmanaged rugged Ethernet switch designed for applications with
severe operating conditions and extreme environments.
With an ultra robust design, sealed to IP67 and vibration resistant to and exceeding
on-board rail standards this unit is ideal for situations where mechanical stress, moisture,
condensation, dirt or continuous vibrations could adversely affect the function of
standard Ethernet switches. Fully approved for onboard rolling stock, this unit can be
deployed in e.g. trains, trams, busses, mining trucks, army vehicles and drilling rigs.
Product model
3641-0540 Viper-012 unmanaged switch.

11
6641-22410
Interface specifications
DC, Power port
Rated voltage 24 to 110 VDC
Operating voltage 16.8 to 143 VDC (14.4 to 154 VDC for 100 ms)
Rated current Viper-x12: Max 350 mA @ 24 V, max 90 mA @ 110 V
Viper-x12-T3G: Max 550 mA @ 24 V, max 120 mA @ 110 V
Rated frequency DC
Inrush current, I²t 1 mA²s @ 24 V and 6 mA²s @ 110 V
Startup current* 535 mA @ 24 V
145 mA @ 110 V
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to 1500 VAC rms to all other
Connection 4 pin male M12 A-coded connector, use Westermo cable
3146-1106 for 1.5 m
3146-1107 for 5 m
Connector size M12, recommended cable area 0.5 mm² recommended
(minimum 0.25 mm²), cable dimensions depend on choice of
M12 connector
* External supply current capability for proper start-up
X1-X12 Ethernet ports
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type Viper-x12:
X1-X12: TNV-1
Viper-x12-T3G:
X1-X3, X5-X7, X9-X11: TNV-1
X4, X8, X12: SELV
Transmission range Up to 150 m with CAT5e cable or better
Isolation to Viper-x12: 1500 VAC rms to all other ports
Viper-x12-T3G: X1-X3, X5-X7, X9-X11: 1500 VAC rms
to other ports
X4, X8, X12: 500 VAC rms to other ports
Connection 4-pin M12 D-code, auto MDI/MDI-X, use e g Westermo cable
3146-1100 M12-M12 – 1 m
3146-1101 M12-M12 – 5 m
3146-1103 RJ45-M12 – 1 m
3146-1104 RJ45-M12 – 5 m
Shielded cable Not required, but recommended in severe electromagnetic
environments
Conductive housing Yes
Number of ports 12

12 6641-22410
Location of interface ports and LED
DC
SRV 1
SRV 2
X1 X5 X9
X6 X10
X7 X11
X8 X12
X2
X3
X4
Ethernet connection TX
Power connection
LED indicators
Earth connection
For
Westermo
internal use
only

13
6641-22410
Power Connector Pin-out
LED Indicators
LED Status Description
DC
SRV 1
SRV 2
X1 X5 X9
X6 X10
X7 X11
X8 X12
X2
X3
X4
DC OFF Unit has no power.
GREEN Power OK on DC1 and DC1.
RED Power failure on DC1 or DC2.
X1 to
X12
OFF No Link.
GREEN Link established.
GREEN
FLASH
Data traffic indication.
YELLOW Port alarm and no link.
*SRV 1 & SRV 2 only for internal use by Westermo staff
*
Pin number Signal
2 1
3 4
No 1 +DC1
No 2 +DC2
No 3 -COM
No 4 -COM

14 6641-22410
Connection of cables
Recommended tightening torque for the M12 connectors: 0.6 Nm
Note that unused connectors must be covered by a protective cap (delivered with the
unit), tightened to the specified torque, in order to fulfill the specified ingress protection
code.
Removal
Disconnect all cables and unscrew the unit from the wall.
Time For Replacement < 15 minutes
Cooling
This unit relies on convection cooling. Make sure that it is installed so that the ambient
temperature is within the specified temperature range, e.g. by avoiding obstruction of the
airflow around the unit.
Wall mounting
There are four 6 mm bore holes intended for mounting the unit. The unit can be
mounted vertical or horizontal. Use four M5 screws with 12 mm washer on a flat and
stable surface.
DC
SRV 1
SRV 2
X1 X5 X9
X6 X10
X7 X11
X8 X12
X2
X3
X4

15
6641-22410
Dimensions
Measurements are stated in millimeters.
7,4
±0,5
36,7
±1
100
±1
56
±0,5
23
±1
6,7
±1
164
±1
142
±1
11
±1
M5
174
±1
22 ±1
6,5
-
0
0,5
(4x)
0
1
35
75
110
111
16
0
1,5
24
23,3
48
48,8
73,5
72
14
54,1
±1
65,4
±1
Material / Remark
Designation / Dimension
Description
Quantity
Pos No
1:1
Scale
Status
Designer
Drawing No.
PaPu
Approved
6001-0001-U-01
Sheet
1(1)
Denomination
Viper-12-series
Dimensional Drawing
© 2010 Westermo Teleindutri AB All rights reserved
Approved
Date
130225
Description
Designer
Rev
Date
Approved
ToDu
PaPu
01
Created
130225
ToDu

Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com
REV. B 6641-22410 2021-06 Westermo Network Technologies AB, Sweden
This manual suits for next models
1
Table of contents