®Duet®Steam Washer
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
DRAIN SYSTEM OPTIONS
WFW9600T,
E ectrica : 120-vo t, 60 Hz, AC-on y,
15 or 20 amp fused e ectrica supp y. A time-de ay
fuse or circuit breaker and separate circuit is
recommended.
Because Whir poo Corporation po icy inc udes a continuous commitment to improve
our products, we reserve the right to change materia s and specifications without notice.
Dimensions are for p anning purposes on y. For comp ete detai s, see Insta ation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10254043
05/2009
5
1"
(1295 mm)
27
"
(686 mm)
38
"
(965 mm)
321/2
"
(813 mm)
Undercounter Insta ation - Washer On y
1
"
(25 mm)
4
"
(102 mm)
18
" min.
(457 mm)
311/2
"
(800 mm)
1
"
(25 mm)
27
"
(686 mm)
3
" (76 mm)
3
" (76 mm)
48 in.2*
(310 cm2)
24 in.2*
(155 cm2)
1
"
(25 mm)
6
" (152 mm)
27
"
(686 mm)
51/2
"**
(140 mm)
1
" ***
(250 mm)
1
" ***
(250 mm)
76
"
(1930 mm)
Washer on Pedesta
27
"
(686 mm)
1
"
(25 mm)
1
"
(25 mm)
39
" min.
(990 mm)
Dimensions shown are the recommended spacing.
Standpipe drain system - wall or floor (view A & B)
The standpipe drain requires a minimum diameter standpipe of 2"(50 mm). The
minimum carry-away capacity can be no ess than 17 ga . (64 L) per minute.
The top of the standpipe must be at east 30"(762 mm) high and no higher than
96"(2.4 m) from the bottom of
the washer.
Laundry tub drain system (view A)
The aundry tub needs a minimum
20 ga . (76 L) capacity. The top of
the aundry tub must be at east
30"(762 mm) above the f oor.
Floor drain system (view B)
The f oor drain system requires a siphon break
that may be purchased separate y.
The siphon break must be a minimum of 28"
(710 mm) from the bottom of the washer.
Additiona hoses might be needed.
*Min. top and
bottom air
openings for
c oset door.
**Externa exhaust
e bow requires
additiona space.
***Wa , door and
f oor mo ding may
require additiona
spacing.
Stacked Washer and Dryer
Recommended insta ation spacing for
cabinet insta ation
For cabinet insta ation, with a door, the minimum
venti ation openings in the top are required.
3
"
(76 mm)
3
"
(76 mm)
34
" min.
(864 mm)
48 in.2*
(310 cm2)
24 in.2*
(155 cm2)
1
"
(25 mm)
4
"
(102 mm)
311/2
"
(800 mm)
RECESSED AREA AND CLOSET INSTALLATIONS
For c oset insta ation, with a door, the minimum venti ation
openings in the top and bottom of the door are required (view B).
Louvered doors with equiva ent air venti ation openings are
acceptab e.
A. Side view - closet or confined area
B. Closet door with vents
AB
ABAB
WFW9450W