manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Whirlwind
  6. •
  7. Control Unit
  8. •
  9. Whirlwind EMOD CO8A User manual

Whirlwind EMOD CO8A User manual

WARRANTY
99 Ling Road - Rochester, NY 14612
800-733-9473 / 585-663-8820 Fax: 585-865-8930
Website: http://www.whirlwindusa.com
Email: [email protected]
This product is guaranteed to be free from defects in materials and workmanship to the
original purchaser for a period of 5 years from the date of purchase. Should service be
required, return the unit postage prepaid along with the original sales receipt to:
Whirlwind
Attention - Repair
99 Ling Road
Rochester, New York 14612
The warranty on this product shall not apply to defects or damage resulting from abuse,
abnormaluseorfromrepairsormodificationsperformedbyanyoneotherthanWhirlwind.Ifitis
determinedamanufacturingdefecthasoccurred,Whirlwindwillrepairorreplacetheunitatour
optionandpaythepostagebacktoyou.
± .56 dBv 20-20 kHz
< .0026 % 20-20 kHz
Frequency Response
Total Harmonic Distortion + Noise 106 dBv
Dynamic Range
Specifications for Whirlwind CO8a
Maximum Output Level +20 dBv
Output Impedance 45 Ohms balanced, pad off
600 Ohms balanced, pad on
VU LED thresholds Red 0 dBv headroom
Yellow 12 dBv headroom
Green 36 dBv headroom
Isolation between output channels 93 dBv 20-20 kHz
Power Consumption 39 Watts max. 21.25 Watts idle
Fan Thresholds
3 stage fan cooling:
Off for internal temperatures below 40°C
Low speed for internal temperatures from 40-50°C
High speed for internal temperatures above 50°C
Power Requirements 85 to 264 VAC, 50 or 60 Hz
Size
Internal Mains fuse
AC dropout voltage
1 RU
2.5 Amp 250V Type SP 0001.1008
85 VAC
All specifications subject to change without notice
With digital input at 0 dBfs, internal pad and gain dip
switches set balanced outputs to: +20 dBv, +6 dBv, +4
dBv, or -10 dBv. There is a 16 dB pad on the output and
a 14 dB gain stage. Factory default is pad off and gain
off which is +6 dBv output with 0 dBfs input level.
Remove cover screws and slide cover forward to clear
LEDs. Lift off to access dip switches.
OUTPUT LEVEL SELECT
CO8A
Line Out Module
The CO8A is Whirlwind's 8-channel CobraNet output module. Use it to deliver
networked digital audio wherever multiple analog outputs are required such as line
level returns in PA systems, feeding powered speaker arrays, paging systems,
multichannel multimedia presentations and more.
Setup and operation are simple and easy. Just set the bundle select wheels to the
appropriate bundle number and the eight channels of audio will be converted to
analog and presented at line level on balanced XLR jacks.
FEATURES
Uses CobraNet networking protocol compatible with all other CobraNet devices
from over 40 manufacturers.
Auto-detects 20 or 24 bit word length.
Auto-detects 5.33 ms, 2.66 ms or 1.33 ms latencies.
Nominal output level is set by internal dipswitches. Factory setting is +6 dBv.
Outputs mute upon power disruptions for system protection.
Front panel LED meters indicate analog signal level.
Integrated universal power supply for 90-250 VAC, 50/60 Hz operation.
Standard 19” rack mount, 1 RU, all connections on rear.
6
7
8
9
Three position LED meters monitor the analog signal at the XLR outputs. The green LED illuminates at -36
dBV, the yellow at -12 dBV and the red at the point of output driver clipping.
CobraNet Parameter Control through Discovery (Disco) v3.4.4.
Setting all the Bundle Select Switches to 00000 allows remote setting of CobraNet parameters through the
network with CobraNet Discovery software, v3.4.4 available at www.cirrus.com/cobranetsoftware. Some of
the parameters that can be controlled on the CO8A include bundle numbers, number of channels in the
bundles, digital word length, latency and persistence.
These parameters are unlike the selections made with the encoders. Bundle numbers and bitwidth:latency
selections made with the switches are hard coded and remembered when the power to the CO8A is cycled.
Settings made through Disco are volatile and forgotten on a power cycle, unless persistence is turned on
and Bundle Select Switches are set to 0. There are also eight receivers available through Disco instead of
just the one through the encoders.
Disco will temporarily override encoder settings other than 00000 on a CO8A. These settings will not be
remembered on power cycling regardless of the persistence setting in Disco.
CobraNet Bundle Select switches are used to select the bundle number to be received by the CO8A. All
65,279 CobraNet bundles are directly accessible from the encoders. Bundles 1-255 are Multicast bundles
and 256-65,279 are Unicast. Individual CobraNet devices must have the same bitwidth and latency to
communicate with each other properly. The setting of the transmitting unit must be acceptable to the device
set to receive that bundle. Many receive devices, including the CO8A, have an autodetect feature that will
match the bitwidth and latency to that of the transmitter. The leftmost encoder also has 3 special functions.
With the encoder in the 7xxxx position, the front three status LEDs (LINK, ACT, FAULT) will flash a code for
the software version in the CO8A. The LEDs will blink the number of the software version with a long pause
between the series of blinks; e.g., four flashes followed by a long pause equals version four. Should the
CO8A ever need to be rebooted, the 8xxxx position of the encoder will cycle a reset of the unit every two
seconds. Unplugging and reconnecting the power cord will also reset the CO8A. The 9xxxx position of the
encoder is a self test for all the LEDs except the power LED. Setting all switches to 0 allows remote setting
of bundle parameters through the network with CobraNet Discovery software v3.4.4. or higher.
CobraNet jack connects the CO8A to the Ethernet switch carrying the CobraNet network. A green LED
indicates network link and a yellow LED indicates data activity. These are duplicated by two green LEDs on
the front panel along with a red Fault LED indicator.
Power inlet is a standard IEC connection. The power supply is internationally universal with a voltage range
of 85 to 264 VAC at 50 or 60 Hz.
1
2345678
Controls and Connections
1
124
43
5
CobraNet LINK, ACT, and FAULT LEDs indicate the status of the CobraNet network connection;
LINK LED illuminates only when the Ethernet cable is connected to a network with other CobraNet devices.
ACT (activity) LED is on only when there is a match between the bitwidth:latency and bundle settings of the
CO8A and those of the transmitting device.
FAULT LED is used to blink a numeric code to the user with a series of blinks followed by a pause. The
number of blinks indicate the following:
Mismatched format or bundle settings
Received audio format is not supported (eg. 96 kHz)
Invalid bundle number selected (greater than bundle # 65279)
Ethernet cable disconnected or no other CobraNet devices on network.
CobraNet can not communicate with DSP in the CO8A.
This code blinks once on power up and whenever an encoder setting change is
detected, to warn the user that persistence is enabled through CobraNet Discovery
v3.4.4 and that changing the encoders from 00000 will defeat Disco control at the
next power cycle. Persistence enabled means that the unit will remember its last
Fan provides cooling to the internal components of the CO8A. There is a foam filter on the front, which
should be cleaned periodically to maintain good airflow. The front plastic fan guard snaps out to expose the
filter.
POWER LED illuminates when AC power is applied to the unit and the unit is operating.
XLR outputs A and B provide active balanced analog audio at line levels. Factory output level is set at +6
dBv. Internal dipswitches can be set to provide three other nominal output levels; -10 dBv, +4 dBv and +20
dBv.
AUDIO SHIELD TO EARTH Switch breaks the connection fromAC Earth to the audio common to reduce
hum when necessary.
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9

Popular Control Unit manuals by other brands

Omron C500-SNT31-V4 Operation manual

Omron

Omron C500-SNT31-V4 Operation manual

ABB SCU200 user manual

ABB

ABB SCU200 user manual

Deif PPU 300 Operator's manual

Deif

Deif PPU 300 Operator's manual

ATEN Altusen PN9108A quick start guide

ATEN

ATEN Altusen PN9108A quick start guide

FoxESS Mira-HV25 user manual

FoxESS

FoxESS Mira-HV25 user manual

TUYA WBR1D-IPEX manual

TUYA

TUYA WBR1D-IPEX manual

Lunos 5/ACM installation manual

Lunos

Lunos 5/ACM installation manual

Advantech SOM 144 Design specification

Advantech

Advantech SOM 144 Design specification

SKUTCH CK-1P8 manual

SKUTCH

SKUTCH CK-1P8 manual

Panasonic WX-CC412BP operating instructions

Panasonic

Panasonic WX-CC412BP operating instructions

Elkron DK510M-P manual

Elkron

Elkron DK510M-P manual

ADTRAN 1200222L1 user manual

ADTRAN

ADTRAN 1200222L1 user manual

Nerival MBD1201 manual

Nerival

Nerival MBD1201 manual

Emerson Fisher F Series instruction manual

Emerson

Emerson Fisher F Series instruction manual

Genie 38647R.S Replacement instructions

Genie

Genie 38647R.S Replacement instructions

Sel SEL-2600 instruction manual

Sel

Sel SEL-2600 instruction manual

SCHUNK ELKE 24 operating manual

SCHUNK

SCHUNK ELKE 24 operating manual

rtd DM35424HR user manual

rtd

rtd DM35424HR user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.