2
NOTE
SELECT THERMOSTAT LOCATION
Properlocation insures thatthe thermostat willprovide a
comfortable home temperature. Observe the following
general rules when selecting a location:
1. Locate thermostat about 5 ft. above the floor.
2. Install thermostat on a partitioning wall, not on an
outside wall.
3. Never expose thermostat to direct light from lamps,
sun, fireplaces or any temperature radiating equip-
ment.
4. Avoid locations close to windows, adjoining outside
walls, or doors that lead outside.
5. Avoid locations close to air registers or in the direct
path of air from them.
6. Makesuretherearenopipesorductworkinthatpart
of the wall chosen for the thermostat location.
7. Never locate thermostat in a room that is warmer or
coolerthantherestofthehome,suchasthekitchen.
8. Avoid locations with poor air circulation, such as
behind doors or in alcoves.
9. Thelivingordining roomisnormallyagoodlocation,
provided there is no cooking range or refrigerator on
opposite side of wall.
INSTALL THERMOSTAT
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
mainfuseorcircuitbreakerboxuntilinstallation
is complete.
Thethermostatmaybemountedonastandard2x4inch
verticaloutletboxor2-gangedoutletboxes.Whenmount-
ing to a 4 x 4 inch junction box is required, use of a
standardadapterplate(notprovided)isnecessary. USE
COPPER CONDUCTORS ONLY.
SPECIFICATIONS
Contact Structure: Snap action
Electrical Rating:
Mounting: Standard 2 x 4 inch outlet box or 2-ganged
outlet boxes. Mounting screws are provided with the
thermostat.Withastandardadapterplate(notprovided),
this thermostat may be mounted on a 4 inch square
junction box
Switch Action: SPDT
(Heating - open on rise)
(Cooling - close on rise)
Temperature Range: 36°F to 90°F (2°C to 32°C)
When the thermostat is set below 40°F (5°C),
damage to the building and/or contents may
result due to freezing. This is possible due to
factory calibration tolerances, thermostat loca-
tionandoperatingcharacteristicsoftheheating
equipment.
System Switch: Heat - Off - Cool
Fan Switch : Low - Medium - High
FAN
SYSTEM
LOW
HEAT
50 60
WHITE-RODGERS
70 80 90
40
40
50
60 70
80
90
4 x 4
JUNCTION
BOX
ADAPTER PLATE
(NOT PROVIDED)
USE 2 x 4 OR 4 x 4
JUNCTION BOX
1A11-2
MOUNTING
SCREWS (2)
VOLTAGE (AC) 120V 240V 277V
Full Load Amps. 5.5 2.75 2.3
Locked Rotor Amps. 33.0 16.5 13.8
Pilot Duty 125VA
CAUTION
!
INSTALLATION
Install the thermostat as follows:
1. Before mounting, connect system wiring to proper
color-codedleadsatrearofthermostat.Followequip-
ment manufacturer's instructions or refer to wiring
diagram for typical system hookups.
2. Remove thermostat cover by grasping top and bottom
ofcoverandpullstraightout.Dresswiringintojunction
boxand secure thermostatto outlet box with mounting
screws.
DO NOT PUSH OR DAMAGE THE KNOB SENSING
ELEMENT DURING INSTALLATION.
3. Installthermostatcover,turnknobtodesiredsetting,
andset selector switches forthe appropriate system
function and fan speed.
CAUTION
!