Installation manual standard/external antenna
UNICOM 300
DDN003MHEN/10-2018/Rev.A1 2
1. Explosion safety instructions (Ex)
WARNING
UNICOM 300 is approved for use inside the explosion-hazardous environment.
UNICOM 300 is equipped with intrinsically safe circuits, which may be connected to
equipment set up in explosion-hazardous environments.
Should you have any questions or need clarification regarding explosion safety with respect to UNICOM 300,
please contact Wigersma & Sikkema (for this, please see the data at the last page).
General additional instructions on explosion safety:
1. If, for whatever reason, a mounted connecting cable has to be disconnected and reinstalled, it must be
checked that the cable is correctly mounted, that no loose wires are present and that the cable gland
is properly secured.
2. If the housing is opened, it must be ensured that no moisture enters the housing.
3. If there are any defects, UNICOM 300 should be repaired by Wigersma & Sikkema.
Additional instructions with regard to explosion safety requirements regarding installation of external
antennas.
4. It is allowed to use any external antenna in combination with the UNICOM 300, however it is
preferable to use the prescribed types to ensure proper operation of the UNICOM in combination with
the external antenna.
5. Shortening the cable of the external antenna is not permitted.
6. Prevent damaging the cable of the external antenna during installation. If the cable is damaged, the
antenna should be replaced as a unit with a non-damaged unit.
7. If the external antenna is placed in the Ex zone, the antenna must not have a gain greater than 2 dB.