manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Willow
  6. •
  7. Breast Pump
  8. •
  9. Willow Wearable Breast Pump User manual

Willow Wearable Breast Pump User manual

reuse, refill, rejoice!
Willow Wearable Breast Pump Milk Container Quick Start Guide
For complete Instructions for Use, visit willowpump.com
1
Cap
Dial
Locking Ring
Spout
Tab
ContainerInsert
meet your milk container
Your Milk Container comes assembled, but has two parts - the Insert and Container.
Tunnel
Locked
Position
Unlocked
Position
Pour
Spout
Interior Valve
TopBackFront
Dial
Air Vent
(underneath Dial)
2
set dial to 1 to pump...
Rotate Dial so only the 1 is visible (and the 2 is hidden under Cap).
Rotate all the
way until
the Dial stops!
‘1’ = Pump
• Set Dial to 1 (Pump
position) at the start of
your session
• This keeps the air vent
open when you pump
TIP: The air vent is open while you pump.
See page 9 for tips to avoid leaks.
3
...and 2 when you’re done!
Rotate Dial so only the 2 is visible (and the 1 is hidden under Cap).
Rotate all the
way until
the Dial stops!
‘2’ = Flip to Finish
• Set Dial to 2 (Flip
to Finish position)
when you’re finished
pumping
• This closes the air
vent for Flip to Finish
• NOTE: If Dial is in
the wrong position
during Flip to Finish,
milk will leak from
the air vent
4
sterilize for first-time use
1. Disassemble Milk Container
2. Boil Container and Insert for ten minutes to sterilize before you use it
(just for the rst time!). Place on a clean surface to air dry.
Peel back
Cap
Rotate blue
locking ring to
unlocked position
1Push hard on Insert
tunnel (use both thumbs!)
until it pops out
2Separate
Container and
Insert
3 4
DO NOT put Container or Insert in a microwave or microwave sterilizer bag.
5
Insert Flextube™Container Pump
get ready to pump
Just 4 parts - and you’re ready to pump!
6
assemble container &insert
Press firmly to
seal to Container
2
Place Insert into
Container (tab facing up)
1Rotate to
locked position
3Make sure
Cap is closed
4
7
Rotate Dial so only
the 1 is visible (and the
2 is under Cap)
7
Connect Flextube™ tip
to Insert spout.
Push tip all the way down!
5Push Flextube™
collar in so it sits firmly
against Cap
6
8
align and attach pump
For more on alignment, pumping, and breaking latch, visit:
willowpump.com for Willow Wearable Breast Pump Instructions for Use
Center your nipple in
the Insert tunnel.
Turn Pump on and bring straight on to
Milk Container with your other hand to
connect. Press Play to initiate latch.
21
9
Watch videos in app or
at willowpump.com
pumping tips (stay dry!)
• The air vent (on the top
of the Milk Container) is
open while you pump.
• To prevent drips, avoid
bending too far forward
or back while you pump
so milk doesn’t leak from
the air vent.
• To pump in any position,
pump with our spill-proof
Milk Bags.
Get up
and pump...
!...but don’t lean
too far forward
or back
10
finished pumping?set dial to 2...
Pause Pump, then rotate Dial to
2 (Flip to Finish position) to close
air vent - or milk will leak!
1
Break latch and
remove Pump
2
Rotate so Cap
faces you
3
TIP: Rotate Dial to 2 (Flip to Finish position) before you
remove Willow from your bra to avoid spills.
11
then flip to finish
Watch videos in app or
at willowpump.com
FLIP all the way over and wait
until gulps stop (a total of 8 gulps)
6
TILT until pump
starts to gulp
4
HOLD until
milk disappears
from tunnel
5
12
time to transfer!
1Flip Pump over so
Milk Container faces up
2Separate Milk
Container from Pump
3Pour any remaining milk
out of tunnel or Flextube™
TIP: Squeeze Flextube™ to
get milk remaining out
of Tunnel and Flextube™
13
6Pour from pour spout on top -
keep Flextube™ assembled.
5
Open Cap
4Rotate Dial to position
1 before opening Cap
TIP: To avoid splashing when
opening Cap, rst rotate Dial
to position 1, then open Cap
14
keep your milk container clean
❏Separate Flextube™ from Milk Container to clean, then
follow instructions on p. 4 to disassemble into parts.
❏Rinse immediately under running water for at least 1 minute.
❏Soak in warm, soapy water for a minimum of 5 minutes
(use mild dishwashing soap, and agitate while they soak).
❏Use the Large Cleaning Brush from your Willow Pump Kit to clean
(wash for at least 60 seconds, minimum 30 seconds of brushing).
Use the Small Cleaning Brush to clean the Insert spout.
❏Rinse with hot water for at least 50 seconds.
❏Place parts on clean paper towels or a drying rack to air dry.
After each use, disassemble, then wash your Container and Insert
in the dishwasher (top rack only) or follow the instructions below!
CAUTION: Do not remove Dial, locking ring, or interior valve to clean.
For cleaning instructions for your Flextube™ and Pump, visit:
willowpump.com for Willow Wearable Breast Pump Instructions for Use
15
!Scrub around
interior valve -
don’t push a brush
through it!
See any signs of milk after cleaning? Repeat the steps above.
!Final step: Rinse
through the
valve from the
Flextube™ side
16
For more information on Willow’s lights, visit:
willowpump.com for Willow Wearable Breast Pump Instructions for Use
milk container alerts & lights
Willow’s lights tell you what’s going on with your Milk Container. Here’s what they mean.
White Solid:
Your Container is full. Flip to Finish (see
p. 10-11), transfer to a bottle or bag, then
press Pump/Pause to continue pumping.
Orange Blinking Solid:
Assembly error. Separate Container and
Pump. Check that Flextube™ is firmly
attached. When attaching Pump, bring
straight on to Container, not at an angle.
pump wherever life takes you.
care@willowpump.com
willowpump.com/help
1-888-WILLOW-3
ART-1084-B
©2019 Willow. All rights reserved. Willow and Flextube are trademarks or
registered trademarks of Willow in the United States and other countries.

Other Willow Breast Pump manuals

Willow Go User manual

Willow

Willow Go User manual

Willow Breast Pump Generation 3 User manual

Willow

Willow Breast Pump Generation 3 User manual

Willow Wearable Breast Pump 2.0 User manual

Willow

Willow Wearable Breast Pump 2.0 User manual

Willow Wearable Breast Pump 2.0 User manual

Willow

Willow Wearable Breast Pump 2.0 User manual

Willow Willow Pump User manual

Willow

Willow Willow Pump User manual

Willow Milk Container User manual

Willow

Willow Milk Container User manual

Popular Breast Pump manuals by other brands

Philips SCF290/20 Specifications

Philips

Philips SCF290/20 Specifications

Philips AVENT SCF323 user manual

Philips

Philips AVENT SCF323 user manual

mamivac Lactive 287000 operating instructions

mamivac

mamivac Lactive 287000 operating instructions

Ameda MyaJoy Instructions for use

Ameda

Ameda MyaJoy Instructions for use

Medela Symphony Instructions for use

Medela

Medela Symphony Instructions for use

NUK jolie operating instructions

NUK

NUK jolie operating instructions

Philips AVENT SCF430 user manual

Philips AVENT

Philips AVENT SCF430 user manual

Pumpables SuperGenie quick start guide

Pumpables

Pumpables SuperGenie quick start guide

Philips Avent SCF312/01 user manual

Philips

Philips Avent SCF312/01 user manual

Apre 2 in 1 Electric Breast Pump user manual

Apre

Apre 2 in 1 Electric Breast Pump user manual

NIMO HNK-SUTPUMP-MNL user manual

NIMO

NIMO HNK-SUTPUMP-MNL user manual

Medela Mini Electric Instructions for use

Medela

Medela Mini Electric Instructions for use

Kitett KOLOR PLAY Instructions for use

Kitett

Kitett KOLOR PLAY Instructions for use

Philips AVENT Isis iQ Uno user guide

Philips AVENT

Philips AVENT Isis iQ Uno user guide

Medela Sonata Instructions for use

Medela

Medela Sonata Instructions for use

Ameda HygieniKit instructions

Ameda

Ameda HygieniKit instructions

Lansinoh SM ARTPUMP 2.0 Instructions for use

Lansinoh

Lansinoh SM ARTPUMP 2.0 Instructions for use

Beurer BY 40 Instructions for use

Beurer

Beurer BY 40 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.