winsonic MFC1045S-XN40C User manual

User’s Manua
- Model #MFC1045S-XN40C
WINSONIC ELECTRONICS Co., LTD
No.290-1, Wen Chung Rd., Taoyuan City, Taiwan, R.O.C
l:+886-3-3704789
ax:+886-3-3704722
E-mail:[email protected]
www.ewinsonic.com
Te
F

AD Board Specification
Panel Specification
Safety Instruction
Product Installation
Contents
General Description
Optical Specifications
Absolute Maximum Ratings
Electrical Specifications
Precautions
Assembly
Trouble Shooting
3
4
5
22
5
6
7
18
21
29
30

Safety Instruction
Read and follow these instructions when connecting and using your LCD monitor:
Operation:
1. Keep the monitor out of direct sunlight and away from stoves or any other heat
source.
2. Remove any object that could fall into ventilation holes or prevent proper cooling
of the monitor's electronics.
3. Do not block the ventilation holes on the cabinet.
4. When positioning the monitor, make sure the power plug and outlet are easily
accessible.
5. If turning off the monitor by detaching the power cable or DC power cord, wait
for seconds before attaching the power cable or DC power cord for normal
operation.
6. Do not subject the LCD monitor to severe vibration or high impact conditions
during operation.
7. Do not knock or drop the monitor during operation or transportation.
Maintenance:
8. To protect your display from possible damage, do not put excessive pressure on
the LCD panel. When moving your monitor, grasp the frame to lift; do not lift the
monitor by placing your hand or fingers on the LCD panel.
9. Unplug the monitor if you are not going to use it for an extensive period of time.
10. Unplug the monitor if you need to clean it with a slightly damp cloth. The screen
may be wiped with a dry cloth when the power is off. However, never use organic
solvent, such as, alcohol, or ammonia-based liquids to clean your monitor.
11. To avoid the risk of shock or permanent damage to the set, do not expose the
monitor to dust, rain, water, or excessive moisture environment.
12. If your monitor gets wet, wipe it with dry cloth as soon as possible.
13. If foreign substance or water gets in your monitor, please turn the power off
immediately and disconnect the power cord. Then, remove the foreign substance
or water, and send it to the maintenance center.
14. Do not store or use the LCD monitor in locations exposed to heat, direct sunlight
or extreme cold.
15. In order to maintain the best performance of your monitor and use it for a longer
lifetime, please use the monitor in a location that falls within the following
temperature and humidity ranges. Temperature: 5-35°C 41-95°F

Product Installation
1. Switch off the power on both your monitor and your computer. The Power Switch
is located in the right of the monitor.
2. Connect the power cord to the AC outlet, and connect the power to the monitor
through the AC/DC adapter.
3. VGA Signal-Plug one end of the 15-pin signal cable to the video signal connector
at the rear of the PC system and the other end to the monitor. Secure the
connectors with the screws on the cable connector at both ends.
4. (Optional) DVI Signal-Plug one end of the DVI signal cable to the video signal
connector at the rear of the PC system and the other end to the monitor. Secure
the connectors with the screws on the cable connector at both ends.
5. (Optional) HDMI Signal-Plug one end of the HDMI signal cable to the video
signal connector at the rear of the PC system and the other end to the monitor.
Secure the connectors with the screws on the cable connector at both ends.
6. (Optional) RS232 Connection- Plug one end of RS232 cable to com-port
connector on your PC system and the other end to the monitor. Secure the
connectors with the screws on the cable connector at both ends.

Panel Specification
1. GENERAL DESCRIPTION
1.1 OVERVIEW
MFC1045S-XN40C is a 10.4” TFT Liquid Crystal Display module with 2-CCFL backlight unit and 30-pin-and-1ch
LVDS interface. This product supports 1024 x 768 XGA format and can display true 16.2M colors (6-bits
colors with FRC). The inverter module for backlight is not built-in.
1.2 FEATURES
-Excellent brightness (400 nits)
- Ultra high contrast ratio (1200:1)
- Fast response time (Ton+Toff average 25 ms)
- High color saturation NTSC 57%
- XGA (1024 x 768 pixels) resolution
- DE (Data Enable) only mode
- LVDS (Low Voltage Differential Signaling) interface
- Ultra wide viewing angle: 176(H)/ 176(V) (CR>10) Super MVAtechnology
-180 degree rotation display option
-Color reproduction (Nature color)
1.3 APPLICATION
- TFT LCD for Avionics and Industrial applications
- High brightness, multi-applications display
1.4 GENERAL SPECIFICATI0NS
Item Specification Unit Note
Active Area 210.4 (H) x 157.8 (V) (10.4” diagonal) mm
Bezel OpeningArea 215.4 (H) x 161.8 (V) mm (1)
Driver Element a-si TFT active matrix - -
Pixel Number 1024 x R.G.B. x 768 pixel -
Pixel Pitch(Sub Pixel) 0.0685 (H) x 0.2055 (V) mm -
Pixel Arrangement RGB vertical stripe - -
Display Colors 16.2 M color -
Display Operation Mode Transmissive mode / Normally black - -
Surface Treatment Anti-Glare coating (Haze 25%)
Hard coating (3H) - -
1.5 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal(H) 225 225.5 226 mm
Vertical(V) 175.8 176.3 176.8 mm (1)
Module Size Depth(D) - 10.17 10.67 mm -
Weight 430 480 530 g -
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.

Panel Specification
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT Value
Item Symbol Min. Max. Unit Note
Storage Temperature TST (-20) (+70) ºC (1)
Operating Ambient Temperature TOP (-10) (+60) ºC (1), (2)
Shock (Non-Operating) SNOP -(220) G (3), (5)
Vibration (Non-Operating) VNOP - (1.5) G (4), (5)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) The maximum operating temperature is based on the test condition that the surface temperature of
display area is less than or equal to 80 ºC with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in your product design to prevent the surface temperature
of display area from being over 80 ºC. The range of operating temperature may degrade in case of
improper thermal management in your product design.
Note (3) 2 ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 300 Hz, 10 min, 1 time each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough so that
the module would not be twisted or bent by the fixture.
0
10
20
30
40
50
60
70
80
90
100
-30 -20 -10 0 10 20 30 40 50 60 70 80
Temperature (ºC)
Relative Humidity (%RH)
Storage Range
Operation Range

Panel Specification
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE Value
Item Symbol Min. Max. Unit Note
Power Supply Voltage Vcc -0.3 4.0 V
Input Signal Voltage VIN -0.3 3.6 V (1)
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE Ta = 25 ± 2 ºC
Value
Parameter Symbol Min. Typ. Max. Unit Note
Power Supply Voltage VCC 3.0 3.3 3.6 V (1)
Power Supply Ripple Voltage VRP - - 100 mV
Rush Current IRUSH - - 1.8 A (2)
White - 1.1 1.4 A
Black - 0.8 - A
Power Supply Current Vertical Stripe ICC - 1.0 - A (3)
Differential Input High
Threshold Voltage VLVTH - - +100 mV
Differential Input Low
Threshold Voltage VLVTL -100 - - mV
Common Input Voltage VLVC 1.125 1.25 1.375 V
LVDS
Interface
Terminating Resistor RT100 ohm
Input High Threshold Voltage VIH 2.7 - 3.3 VCMOS
interface Input Low Threshold Voltage VIL 0 - 0.7 V
Note (1) The assembly should be always operated within above ranges.
Note (2) Measurement Conditions:

Panel Specification
Note (3) The specified power supply current is under the conditions at Vcc = 3.3 V, Ta = 25 ± 2 ºC, fv= 60
Hz, whereas a power dissipation check pattern below is displayed.
Active Area
c. Vertical Stripe Pattern
R
R
R
R
RR
R
R
G
G
G
G
B
B
B
B
B
B
G
G
G
G
B
B
B
B
R
R
Active Area
Active Area
a. White Pattern b. Black Pattern
Vcc rising time is 470us
470µs
+3.3V
GND
0.9Vcc
0.1Vcc

Panel Specification
3.2 BACKLIGHT UNIT
3.2.1 CCFL (Cold Cathode Fluorescent Lamp) CHARACTERISTICS (Ta = 25 ± 2 ºC)
Value
Parameter Symbol Min. Typ. Max. Unit Note
Lamp Voltage VW460 VRMS IL= 7.0mA
Lamp Current IL6.5 7 7.5 mARMS (1)
770(25 ) VRMS (2)
Lamp Starting Voltage VS960(0 ) VRMS (2),
Operating Frequency FO45 80 KHz (3)
Lamp Life Time LBL 50,000 Hrs (4)
4. BLOCK DIAGRAM
4.1 TFT LCD MODULE
TFT LCD PANEL
(1024x3x768)
DATA DRIVER IC
SCAN DRIVER IC
DC/DC CONVERTER &
REFERENCE VOLTAGE
INPUT CONNECTOR
(JAE,FI-XB30SRL-HF11)
GND
Vcc
FRAME BUFFER
RX0(+/-)
RX1(+/-)
RX2(+/-)
RX3(+/-)
RXCLK
(
+/-
)
TIMING
CONTROLLER

Panel Specification
5. INTERFACE PIN CONNECTION
5.1 TFT LCD MODULE
CN1 Connector Pin Assignment
Pin No. Symbol Description Note
1 NC No Connection (2)
2 GND Ground
3 RX3+ Positive transmission data of pixel 3
4 RX3- Negative transmission data of pixel 3
5 GND Ground
6 RXCLK+ Positive of clock
7 RXCLK- Negative of clock
8 GND Ground
9 RX2+ Positive transmission data of pixel 2
10 RX2- Negative transmission data of pixel 2
11 GND Ground
12 RX1+ Positive transmission data of pixel 1
13 RX1- Negative transmission data of pixel 1
14 GND Ground
15 RX0+ Positive transmission data of pixel 0
16 RX0- Negative transmission data of pixel 0
17 GND Ground
18 STV Vertical Start Pulse Output
19 GND Ground
20 NC No Connection
21 NC No Connection
22 NC No Connection
23 NC No Connection
24 RPF Display Rotation (3)
25 GND Ground
26 GND Ground
27 GND Ground
28 VCC Power supply: +3.3V
29 VCC Power supply: +3.3V
30 VCC Power supply: +3.3V
Note (1) Connector Part No.: JAE,FI-XB30SRL-HF11 or compatible
Note (2) Reserved for internal use. Left it open.
Note (3) Low : normal display (default), High : display with 180 degree rotation

Panel Specification
5.2 BLOCK DIAGRAM OF INTERFACE CN1
Rx3+
Rx3
-
51
51
51
51
51
51
51
51
51
51
100pF
100
p
F
100pF
100pF
100pF
CLK
-
CLK+
Rx2-
Rx2+
Rx1-
Rx1+
Rx
0
-
Rx0+
LVDS Receiver
THC63LVDF84A
LVDS Transmitter
THC63LVDM83A
(LVDF83A)
DCLK
Timing
Controller
DE
B
0
-B7
G0
-
G
7
R0-R7
RxOUT
PLL
PLL
TxIN
Host
Graphics
Controller
DE
B
0
-B7
G0
-
G
7
R0-R7
R0~R7 : Pixel R Data ,
G0~G7 : Pixel G Data ,
B0~B7 : Pixel B Data ,
DE : Data enable signal
Note (1) The system must have the transmitter to drive the assembly.
Note (2) LVDS cable impedance shall be 50 ohms per signal line or about 100 ohms per twist-pair line when it is
used differentially.

Panel Specification
5.3 LVDS INTERFACE
TRANSMITTER
THC63LVDM83A INTERFACE
CONNECTOR RECEIVER
THC63LVDF84A
SIGNAL PIN INPUT Host TFT-LCD PIN OUTPUT
TFT CONTROL
INPUT
R0
R1
R2
R3
R4
R5
G0
G1
G2
G3
G4
G5
B0
B1
B2
B3
B4
B5
DE
R6
R7
G6
G7
B6
B7
RSVD 1
RSVD 2
RSVD 3
51
52
54
55
56
3
4
6
7
11
12
14
15
19
20
22
23
24
30
50
2
8
10
16
18
25
27
28
TxIN0
TxIN1
TxIN2
TxIN3
TxIN4
TxIN6
TxIN7
TxIN8
TxIN9
TxIN12
TxIN13
TxIN14
TxIN15
TxIN18
TxIN19
TxIN20
TxIN21
TxIN22
TxIN26
TxIN27
TxIN5
TxIN10
TxIN11
TxIN16
TxIN17
TxIN23
TxIN24
TxIN25
TA OUT0+
TA OUT0-
TA OUT1+
TA OUT1-
TA OUT2+
TA OUT2-
TA OUT3+
TA OUT3-
Rx 0+
Rx 0-
Rx 1+
Rx 1-
Rx 2+
Rx 2-
Rx 3+
Rx 3-
27
29
30
32
33
35
37
38
39
43
45
46
47
51
53
54
55
1
6
7
34
41
42
49
50
2
3
5
Rx OUT0
Rx OUT1
Rx OUT2
Rx OUT3
Rx OUT4
Rx OUT6
Rx OUT7
Rx OUT8
Rx OUT9
Rx OUT12
Rx OUT13
Rx OUT14
Rx OUT15
Rx OUT18
Rx OUT19
Rx OUT20
Rx OUT21
Rx OUT22
Rx OUT26
Rx OUT27
Rx OUT5
Rx OUT10
Rx OUT11
Rx OUT16
Rx OUT17
Rx OUT23
Rx OUT24
Rx OUT25
R0
R1
R2
R3
R4
R5
G0
G1
G2
G3
G4
G5
B0
B1
B2
B3
B4
B5
DE
R6
R7
G6
G7
B6
B7
NC
NC
NC
24 bit
DCLK 31 TxCLK IN TxCLK OUT+
TxCLK OUT- RxCLK IN+
RxCLK IN- 26 RxCLK OUT DCLK
R0~R7: Pixel R Data (7; MSB, 0; LSB)
G0~G7: Pixel G Data (7; MSB, 0; LSB)
B0~B7: Pixel B Data (7; MSB, 0; LSB)
DE: Data enable signal
Notes(1) RSVD(reserved)pins on the transmitter shall be “H” or “L”.

Panel Specification
5.4 COLOR DATA INPUT ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input for
the color. The higher the binary input, the brighter the color. The table below provides the assignment of
color versus data input.
Data Signal
Red Green Blue
Color
R7 R6 R5 R4 R3 R2 R1 R0 G7 G6 G5 G4 G3 G2 G1 G0 B7 B6 B5 B4 B3 B2 B1 B0
Basic
Colors
Black
Red
Green
Blue
Cyan
Magenta
Yellow
White
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
1
0
1
0
1
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
0
0
0
1
1
1
0
1
Gray
Scale
Of
Red
Red(0) / Dark
Red(1)
Red(2) :
:
Red(253)
Red(254)
Red(255)
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
1
:
:
0
1
1
0
1
0
:
:
1
0
1
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
Gray
Scale
Of
Green
Green(0) / Dark
Green(1)
Green(2)
:
:
Green(253)
Green(254)
Green(255)
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
1
:
:
0
1
1
0
1
0
:
:
1
0
1
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
Gray
Scale
Of
Blue
Blue(0) / Dark
Blue(1)
Blue(2):
:
Blue(253)
Blue(254)
Blue(255)
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
0
0
0
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
0
:
:
1
1
1
0
0
1
:
:
0
1
1
0
1
0
:
:
1
0
1
Note (1) 0: Low Level Voltage, 1: High Level Voltage

Panel Specification
6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
The input signal timing specifications are shown as the following table and timing diagram.
Signal Item Symbol Min. Typ. Max. Unit Note
Frequency 1/Tc 55 65 75 MHZ
LVDS Receiver Clock Input cycle to
cycle jitter Trcl - - 200 ps
Setup Time Tlvsu 600 - - ps
LVDS Receiver Data Hold Time Tlvhd 600 - - ps
Frame Rate Fv 50 60 70 Hz
Total Tv 770 806 950 Th Tv=Tvd+Tvb
Display Tvd 768 768 768 Th -
Vertical Active Display Term
Blank Tvb 2 38 182 Th -
Total Th 1100 1344 1800 Tc Th=Thd+Thb
Display Thd 1024 1024 1024 Tc -
Horizontal Active Display Term Blank Thb 76 320 776 Tc -
Note (1) Since this assembly is operated in DE only mode, Hsync and Vsync input signals should be set to
low logic level. Otherwise, this assembly would operate abnormally.
INPUT SIGNAL TIMING DIAGRAM
Tv
Tvd Tvb
Th
DE
Thb
Valid display data (1024 clocks)
DCLK
TcThd
DATA
DE

Panel Specification
LVDS RECEIVER INTERFACE TIMING DIAGRAM
Tc
RXCLK+/-
RXn+/-
Tlvsu
Tlvhd
14
3T14
5T14
7T14
9T14
11T14
13T
14
1T

Panel Specification
6.2 POWER ON/OFF SEQUENCE
To prevent a latch-up or DC operation of LCD assembly, the power on/off sequence should be as the diagram
below.
0.5 T110ms
0T250ms
0T350ms
500ms T4
50%
0V
0V
50%
T6
T5
T3T1
0.1Vcc
0.9 VCC
0.1VCC
0.9 VCC
T4
T2
VALID
Power On
Power Supply
VCC
Signals
Power Off
Backlight (Recommended)
500ms T5
100ms T6
Power ON/OFF Sequence
Note (1) The supply voltage of the external system for the assembly input should follow the definition of Vcc.
Note (2) Apply the lamp voltage within the LCD operation range. When the backlight turns on before the LCD
operation or the LCD turns off before the backlight turns off, the display may momentarily become
abnormal screen.
Note (3) In case of Vcc is in off level, please keep the level of input signals on the low or keep a high
impedance.
Note (4) T4 should be measured after the assembly has been fully discharged between power off and on period.
Note (5) Interface signal shall not be kept at high impedance when the power is on.

Panel Specification
7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Item Symbol Value Unit
Ambient Temperature Ta 25±2oC
Ambient Humidity Ha 50±10 %RH
Supply Voltage VCC 5.0 V
Input Signal According to typical value in "3. ELECTRICALCHARACTERISTICS"
Lamp Current ILmA
Oscillating Frequency (Inverter) FWKHz
Vertical Frame Rate Fr 60 Hz
7.2 OPTICAL SPECIFICATIONS
The relative measurement methods of optical characteristics are shown in 7.2. The following items should
be measured under the test conditions described in 7.1 and stable environment shown in Note (6).
Item S
y
mbol Condition Min. T
yp
. Max. Unit Note
Contrast Ratio CR
(
1200
)
-
(
2
)
TR(15) ms
Response Time TF(10) ms (3)
Center Luminance of White L
C
(
400
)
cd/m2
(
4
)
White Variation δW
(
1.4
)
-
(
7
)
Cross Talk CT
(
4
)
%
(
5
)
Rx
(
0.627
)
-
Red R
y
(
0.351
)
-
Gx
(
0.304
)
-
Green G
y
(
0.566
)
-
Bx
(
0.146
)
-
Blue B
y
(
0.103
)
-
Wx
(
0.319
)
White W
y
Typ.
-0.03
Typ.
+0.03 (6)
Color
Chromaticity
Color Gamut CG
θx=0°,θY=0°
Viewing Normal
Angle
57 % NTSC
θ
x
+
(
88
)
Horizontal θ
x
-
(
88
)
θ
Y
+
(
88
)
Viewing
Angle Vertical θ
Y
-
CR≥10
(
88
)
Deg. (1)
(
0.338
)

Panel Specification
Note (1) Definition of Viewing Angle (θx, θy):
Viewing angles are measured by BM5A
θX- = 90º
θX+ = 90º
Normal
θx =θy = 0º
x+
y-
y+
x-
θy+ θy-
θx+
θx−
6 o’clock
θy- = 90º
12 o’clock direction
θy+ = 90º
Note (2) Definition of Contrast Ratio (CR):
The contrast ratio can be calculated by the following expression.
Contrast Ratio (CR) = L255 / L0
L255: Luminance of gray level 255
L 0: Luminance of gray level 0
CR = CR (5), where CR (X) is corresponding to the Contrast Ratio of the point X at the figure in Note
(7).
Note (3) Definition of Response Time (TR, TF):
TR
TFTime
Gra
y
Level 255
GrayLevel 0
GrayLevel 255
Optical
Response
100%
90%
10%
0%
.

Panel Specification
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point and 5 points
LC= L (5), where L (X) is corresponding to the luminance of the point X at the figure in Note (7).
Note (5) Definition of Cross Talk (CT):
CT = | YB– YA| / YA×100 (%)
Where:
YA= Luminance of measured location without gray level 0 pattern (cd/m2)
YB= Luminance of measured location with gray level 0 pattern (cd/m2)
Gray 128
(D,W)
(0, 0)
YA, L (D/8,W/2)
YA, D (D/2,7W/8)
YA, R (7D/8,W/2)
YA, U (D/2,W/8)
A
ctive Area YB, U (D/2,W/8)
(0, 0)
Gray 0
Gray 0
(D/4,W/4)
(3D/4,3W/4)
YB, R (7D/8,W/2)
Gray 128
YB, L (D/8,W/2)
YB, D (D/2,7W/8)
A
ctive Area
(D,W)
Note (6) Measurement Setup:
The LCD assembly should be stabilized at given temperature for 30 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 30 minutes in a windless room.
Light Shield Room
(Ambient Luminance < 2 lux)
Center of the Screen
LCD Panel
LCD
500 mm
Field of View = 2º
Photometer
(TOPCON BM-5A)

Panel Specification
Note (7) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 5 points
δW = Maximum [L (1), L (2), L (3), L (4), L (5)] / Minimum [L (1), L (2), L (3), L (4), L (5)]
Horizontal Line
X
3W/4
W/2
W/4
3D/4D/2D/4
43
21
5: Test Point
X=1 to 5
W
D
Vertical Line
Active Area
Table of contents
Other winsonic Monitor manuals

winsonic
winsonic MFC1705S-EN30C User manual

winsonic
winsonic MCH1505S-XN25C User manual

winsonic
winsonic MFC1045S-SN35C User manual

winsonic
winsonic CH1905-EN25L0 User manual

winsonic
winsonic MFM1905S-EN30C User manual

winsonic
winsonic MCH1045S-XN40C User manual

winsonic
winsonic VH-CH6504-QF35L0-0000R-MIL User manual