Operating Instructions
Winterhalter Gastronom RoMatik 150
In order to guarantee many years of trouble-free
service, we recommend that you sign a mainte-
nance contract with your local Winterhalter
service centre.
Summary:
1. Intended purpose.....................................................................................................................................1
2. Installation and initial start-up..................................................................................................................2
3. Safety instructions for the operator .........................................................................................................2
4. Indicating elements..................................................................................................................................3
5. Operating the appliance ..........................................................................................................................3
6. Caring for the appliance ..........................................................................................................................3
7. Error messages .......................................................................................................................................4
8. Keeping the membrane moist..................................................................................................................6
9. Requirements for the Untreated Water (raw water)................................................................................6
10. Technical data .........................................................................................................................................6
1. Intended purpose
The Winterhalter Gastronom RoMatik 150 is designed for softening cold water (max. 25°C) in
preparation for use in commercial dishwashers.
The RoMatik 150 may only be connected to a dishwasher.
The feed water must conform to the specifications of the Ordinance on Drinking Water (see Page 6).
The appliance may only be used for this purpose and in accordance with the operating instructions provided.
Any change in the use or design of the RoMatik 150 without our written consent shall exempt us from all
guarantee and product liability obligations.

2
Winterhalter Gastronom GmbH
Tettnanger Str. 72
D-88070 Meckenbeuren
89005232-05
03/12 sch
2. Installation and initial start-up
The RoMatik 150 must be installed and connected to the on-site supply and waste pipes by a trained fitter in
accordance with the ”Installation Instructions for Winterhalter Gastronom RoMatik 150”.
The initial start-up procedure and briefing of the customer must be carried out according to the ”Start-up
Instructions for Winterhalter Gastronom RoMatik 150”.
For this purpose, contact the Winterhalter factory representative responsible for your site once the appliance
has been correctly connected up.
The RoMatik 150 is not ready for operation until all the necessary work has been completed.
3. Safety instructions for the operator
The following instructions must be observed in the interest of safe operation:
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they
have been given supervision or instruction
concerning use of the appliance by a person
responsible for their safety.
Children should being supervised to ensure
that they do not play with the appliance
Only operate the appliance as described in
these operating instructions.
Only use this appliance after having read and
understood the operating instructions and
been personally briefed on its workings and
operation.
The operating instructions are an integral part
of the appliance! In the event of a
resale of the RoMatik 150, be sure to pass on
the operating instructions to the new
owner/operator.
Risk of injury: Do not open any coverings or
machine parts for which the use of a tool is
required.
Electric shock hazard: Do not interfere with
the electrical equipment of the appliance
yourself under any circumstances: always
leave this to a qualified electrician.
The appliance may only be
connected to a cold water supply
(max. 25°C).
The appliance can only function properly if it is
permanently connected to the power and water
supply. If not, unpleasant odours may occur in
the water due to microbiological processes
and the appliance may be
damaged.
If the RoMatik 150 is to be taken out of
operation for more than 2 weeks
(disconnected from power and water sup-
ply), the membrane has to be moistened by
Winterhalter after-sales service.
Any faults which are not due to the on-site
water or power supply lines must be reported
to the Winterhalter after-sales service.
If a leak occurs in any part of the appliance,
shut off the water supply immediately and re-
move the mains plug in order to de-energise
the appliance.
Check all water connections for leaks once a
month. Leakages outside the appliance are not
detected by its safety system.
The appliance must not be stored in rooms
at temperatures below 5° C.
The appliance is not splash-proof. Do not
clean the outside with a wet cloth or with a
high-pressure or steam-jet cleaning device. Do
not use detergents. Only wipe the outside of
the appliance with a damp cloth. If the appli-
ance cannot be protected against splash water
for structural reasons, an additional substruc-
ture should be provided.
Take care to avoid crushing hoses or cables
when moving or cleaning the appliance.
If the mains lead has been damaged in some
way, it must be replaced by a qualified person
to avoid damage or injury.
The plug should be easily accessible after in-
stallation.

89005232-05
03/12 sch
Winterhalter Gastronom GmbH
Tettnanger Str. 72
D-88070 Meckenbeuren 3
4. Indicating elements
The indicating elements are located at the front of the appliance.
They enable the operator to monitor the water quality (”Purity level I, II and III”) during the water
purification process and also serve to display error messages.
If an error message occurs, contact the Winterhalter after-sales service and quote the displayed error
message.
Your appliance is working normally if the indicator for purity level II or III lights up no later than 2 minutes
after the commencement of water purification. If the indicator for purity level I lights up, this means that the
water quality has deteriorated.
The system then switches automatically to fault status (see error messages) and stops the purification
process.
5. Operating the appliance
Once your RoMatik 150 has been installed and calibrated by the Winterhalter service technician, it is ready
to be put into operation.
The RoMatik 150 is equipped with an electronic control system in order to simplify operation. During
normal operation, there are only a few points to be observed:
Observe indicating elements for the purity level in order to detect any deterioration in the water quality
at an early stage. This will also affect the washing results of your dishwasher.
Observe error messages in order to be able to notify the Winterhalter after-sales service in time and
so avoid damage to the appliance.
After producing purified water continuously for 15 minutes, the appliance automatically performs a
flushing cycle. This is not an error.
6. Caring for the appliance
Only use a damp cloth and no other cleaning agents on the RoMatik 150. Do not rinse the appliance
with water.
Check all water connections regularly. Condensation beneath the filter behind the front cover is not a
sign of leakage, and can be simply wiped dry. If the ”stop” indicator lights up due to an accumulation of
condensation, remove the mains plug after wiping and wait for 2 minutes before plugging it in again.
Check the indicating elements regularly for error messages.
calibration
Kalibriertaste
purification level
Reinheitsgrad
stop
on/off
filter I
IIIIII
filter II

4
Winterhalter Gastronom GmbH
Tettnanger Str. 72
D-88070 Meckenbeuren
89005232-05
03/12 sch
7. Error messages
To protect both the user and the appliance itself from incorrect use, the RoMatik 150 is equipped
with various built-in safety devices for interrupting the operation of the appliance.
The following table explains the possible causes of common warnings. If the cause of the error cannot be
eliminated, the Winterhalter after-sales service should be contacted.
The symbols used have the following meanings:
Indicator extinguished
Indicator illuminated
Indicator flashing
Display Cause of error Remedy
Indicates internal leakages or con-
densation on the base plate
Splash water from outside
If all connections are wa-
tertight, the Winterhalter
after-sales service should
be notified
Water supply is shut off or interrupted Remove mains plug, open
water shut-off valves, wait
for 2 minutes, then
re-insert plug mains plug
Important: the device
must be connected
permanently to the power
and water supplies
Contaminated strainer in dirt trap of
shut-off valve or solenoid valve of
water inlet
Close shut-off valve, clean
strainer and re-open
shut-off valve.
If the error message
persists, the strainer in the
solenoid valve may be
blocked.
In this case, notify the
Winterhalter after-sales
service
Filter I is clogged Notify Winterhalter after-
sales service
or
The water pressure is too low on a
permanent basis. The RoMatik was
not able to automatically restart
Check parts that could
influence the water pres-
sure (water line, dirt
screen).
Have a membrane-type
pressure vessel installed.

89005232-05
03/12 sch
Winterhalter Gastronom GmbH
Tettnanger Str. 72
D-88070 Meckenbeuren 5
Display Cause of error Remedy
Filter II needs replacing
Note: this indicator lights up after a
maximum of 6 months or 1000 hours
of permeate production
Notify Winterhalter
after-sales service
Indicates reduced water quality
Error in the water quality measuring
device
Notify Winterhalter
after-sales service
Error in the water quality measuring
device Notify Winterhalter
after-sales service
Poor rinsing result due to low
water production / throughput Membrane may be clogged
Error in control system
Notify Winterhalter
after-sales service
Unpleasant odours in water RoMatik 150 has been disconnected
from the water or power supply
Microbiological processes (due to
lack of flushing) have produced un-
pleasant odours in the water
Notify Winterhalter
after-sales service
Water pressure that is too low RoMatik automatically
starts after 3 minutes,
after 20 minutes and after
4 hours *
*Starting with Lot No. 70 600 001, the RoMatik 150 automatically starts when a malfunction arises because
of water pressure that is too low.
The RoMatik 150 can also be manually restarted by pressing the calibration button until the "filter I" and
"stop" LEDs go out.

6
Winterhalter Gastronom GmbH
Tettnanger Str. 72
D-88070 Meckenbeuren
89005232-05
03/12 sch
8. Keeping the membrane moist
If the RoMatik 150 is to be taken out of operation for more than 2 weeks (disconnected from power and
water supply), the membrane has to be moistened by Winterhalter after-sales service, who should be
notified again before operation is resumed after the break.
9. Requirements for the Untreated Water (raw water)
The feed water must conform to the specifications of the Ordinance on Drinking Water:
Extract from the German Ordinance on drinking water:
Substance Limit value
Copper max. 2.0 mg/l
Manganese max. 0.05 mg/l
Sulphate max. 240 mg/l
Furthermore, the following tightened limit values are valid:
Bezeichnung Limit value
Raw water temperature1 max. 25 °C
Conductivity of the raw water 1max. 1500 µs/cm
Total hardness max. 31°e (25 °dH) (4,5 mmol/l)
Water flow pressure min. 1.5 bar (150 kPa)
Water flow pressure max. 6 bar (600 kPa)
Chlorine max. 0.3 mg/l
Iron max. 0.2 mg/l
10. Technical data
Dimensions Height: 465 mm
Width: 225 mm
Depth: 460 mm (395mm excluding handle and hoses)
Weight 29 kg without water (on delivery)
33 kg with water
Capacity (clean water amount) Max. 3.1 (±0.5) litres/minute with 15°C water inlet
temperature and constant flow
Electrical connection 230V/1/N/PE/50-60Hz, 10 A, earthing contact
Water connection Cold water; min. 1.5 bar flow pressure (8 l/min); max. 6 bar
Power consumption 530 W
Noise emission < 60 dB(A)
Operating range
Air temperature
Air humidity
5 - 42°C
25 - 95%
Conductivity of the clean water (permeate)1 80 µs/cm (with conductivity of the raw water of 1500 µs/cm
and a raw water temperature of 15° C)
Yield rate 65%
1The conductivity of the clean water depends on the conductivity and the temperature of the raw water.
If raw water conductivity of greater than 1500 µs/cm exists, conductivity of the clean water of 80 µs/cm can
only be achieved when the raw water temperature is lower by a corresponding amount.
Table of contents
Popular Water Dispenser manuals by other brands

BRIO
BRIO CLCTTL520 Setup manual

Lincoln Electric
Lincoln Electric COOL ARC 55 Operator's manual

LF
LF Matic Instruction and maintenance

Oster
Oster Chill & Filter Powered Water Dispenser instruction manual

Quality Espresso
Quality Espresso Water/Steam Dispenser user manual

Elkay
Elkay LMABF-BAC Series Installation, care & use manual

Better Water
Better Water PB2 Operator's manual

Cosmetal
Cosmetal AQUA-LITY Installation, use and maintenance handbook

BRIO
BRIO CLPOU520UVRO4B Installation and operation manual

Fast & Fluid Management
Fast & Fluid Management TM300 manual

EcoWater
EcoWater ERO-375 owner's manual

Coway
Coway Nurisu CHP-01BR user manual