Wiseair WADS Series User manual

User Manual
for
Dew Point
Sensor Series
WADS
201 / 202 / 203 / 204
User Manual
2021 Release 2
WiseAir Technologies India LLP
[email protected] +91 90477 78715
Page 1 of 20
WADS SERIES
DEW POINT SENSOR
MEASURE TO MANAGE

User Manual
2021 Release 2
WiseAir Technologies India LLP
[email protected] +91 90477 78715
Page 2 of 20
WADS SERIES
DEW POINT SENSOR
MEASURE TO MANAGE
TABLE CONTENTS
Section Contents Page No.
1
2
3
4
5
6
7
8
9
10
11
12
13
General Information
About WADS Series Dew Point Sensor
What's in the Box?
How to Choose the Correct Sensor for your Application
Product Specifications
Installation - Mechanical
Installation - Electrical (Wiring)
Communication Settings
Warranty
Calibration
Need Help
Technical Support
Commissioning Report
3
5
7
8
10
11
14
15
15
16
16
17
18

User Manual
2021 Release 2
WiseAir Technologies India LLP
[email protected] +91 90477 78715
Page 3 of 20
WADS SERIES
DEW POINT SENSOR
MEASURE TO MANAGE
Section 1 : General Information :
1.1 Please read this user manual in full and carefully observe the notes
and instructions before and during installation, operation and maintenance. The
manufacturer cannot be held liable for any damage which occurs as a result of
non-observance or noncompliance with this user manual.
Should the device be tampered with in any manner other than a
procedure which is described and specified in this manual, the warranty is
cancelled and the manufacturer is exempt from liability. The device is designed
exclusively for the described application.
This user manual should be read carefully by the technician / qualified
personnel and the end user. This manual should be kept with the Dew Point
Sensor and made available to relevant personnel as needed.
1.2 Compressed Air Safety
Any contact with quickly escaping air or bursting parts of the compressed
air system can lead to serious injuries or even death.
Do not exceed the maximum permitted pressure
Only use pressure tight installation material.
Avoid getting hit by escaping air or bursting parts.
The system must be pressure-less during maintenance work.
1.3 Electrical Safety
Any contact with energized parts of the product, may lead to an electrical
shock which can lead to serious injuries or even death. Consider all regulations
for electrical installations.
The system must be disconnected from any power supply during
maintenance work.
Any electrical work on the system is only allowed by authorised qualified
personnel.

User Manual
2021 Release 2
WiseAir Technologies India LLP
[email protected] +91 90477 78715
Page 4 of 20
WADS SERIES
DEW POINT SENSOR
MEASURE TO MANAGE
1.4 Installing the Dew Point Sensor, Calibration & Maintenance
The product must be installed properly and frequently calibrated,
otherwise it may lead to the wrong measurement values, which can lead to
wrong results.
Do Not Exceed the Maximum Operation Temperature at the
Sensors Tip.
Please observe national regulations before/during installation
and operation.
Do not disassemble the product.
Always use a spanner to mount the product properly
1.5 Using the Dew Point Sensor
Do not use this product in explosive areas.
Do not exceed the permitted operating parameters. Any operation
exceeding these parameters can lead to malfunctions and may lead to damage
on the instrument or the system.
Do not exceed or go below the permitted storage and operation
temperature and pressure.
This product should be maintained and calibrated frequently, at least
annually.
1.6 Storage and transportation
Make sure that the transportation temperature of the sensor is
between - 10°C to 60 °C.
Please make sure that the storage temperature of the sensor is
between -10 °C to 50 °C and the humidity is <90%, no condensation. Avoid direct
UV and solar radiation during storage.

User Manual
2021 Release 2
WiseAir Technologies India LLP
[email protected] +91 90477 78715
Page 5 of 20
WADS SERIES
DEW POINT SENSOR
MEASURE TO MANAGE
2.1 Importance of Dew Point:
When it comes to monitoring compressed air systems, nothing offers a
better payback than a dew point sensor. Once you have moisture in your system,
everything becomes a problem. If you have ever had this occur, you'll know the
problem occurred days before you discovered it and it took even longer to dry out
after the issue was fixed.
Most people don't think of dew point sensors as providing efficiency, but
wet compressed air will do irreparable damage to components, create reliability
issues throughout your entire plant and allow bacteria, rust and corrosion to
build up in your system. Moisture issues are extremely difficult to rectify and
component failures will go on for years.
If you have a system running a desiccant dryer or with a specified purity
requirement, then you are already demonstrating your dew point is a critical
component of your system and therefore should be monitored continuously.
2.2 Indicators on Refrigerant Dryers Don't Measure Dew Point
The indicator on your refrigerant dryer is exactly that, an indicator, it is not
measuring the dew point entering your plant. It is only measuring the
temperature of the refrigerant gas. Any number of issues before and after your
dryer can lead to the dew point deteriorating and they will not be shown on the
dryer indicator.
Compared to your compressed air system, dew point sensors are cheap,
easy to install and have low maintenance requirements. They are the most cost
effective sensor purchase you are ever likely to make.
2.3 Benefits of Monitoring Dew Point
Improve system reliability
Reduce product contamination risks
Reduce system maintenance
Reduce operating and energy costs
Reduce the risk of rust and corrosion build up
Improve dryer reliability