Installation
All WISI Antennas are manufactured using well certified materials and assembly components that
ensure a reliable and long life product.
During installation, for proper use and safety, screws and bolts have to be used in proper indicated
place without exchange in position (e.g. do not use a M4 bolt where an M6 is foreseen).
The personnel in charge of installation will be the sole responsible of the pole fixation on roof or wall,
and have to take care of the proper tightening between antenna components. If not elsewhere indi-
cated, the following table report the recommended tightening torque, in Newton * meter, to be applied
on different mechanical couplings.
Thread size Tightening Torque
Bolt/Nut assembly
Tightening Torque
Bolt/Insert assembly
pitch min [Nm] max [Nm] min [Nm] max [Nm]
M3 1.1 1.5 0.7 1.1
M4 2.2 3.1 1.5 2.2
M5 4.2 6.0 2.9 4.2
M6 7.3 10.4 5.1 7.3
M8 17.1 24.4 12.0 17.1
M10 35.1 50.1 24.5 35.1
Maintenance Plan
Antennas have shown good durability even in worst conditions, provided that no perma-nent
damages to plating or painting have been procured during the installation or due to other origins
after installation.
Nevertheless, a periodic maintenance enforce the warranty validity and help in order to elongate the
life of the assembly.
Period Every two years or in case of storm wind and/or strong hailstorm
General care Verify the integrity of the antenna assembly.
Clean with a conventional duster the dish surface and the LNB feed -do not use solvents
for normal cleaning- dry cleaning is normally enough, use water or alcohol to remove
solid attached elements, dry with a cloth.
Paint If the painting has been ruined, remove gently the rust, if present, using a fine abrasive
paper (type 00), then clean with acetone, chloroform or similar oil free solvent, dry and
than repaint with two pass of -water based- opaque paint of the proper RAL. (Conven-
tional paint used in car repair. Please refer to the paint Manufacturer recommendations
for the latency time between the painting).
Chemical solvents are flammable and volatile : do not expose directly, protect with mask and gloves.
Use only opaque paints. Brilliant paints can over heat the LNB “cooking” it with permanent damages.
Zinc plating If damaged due to environmental corrosion, zinc plating can be restored with a chemical
zinc spray (ZINK TK0105 by TEKNICA -Italy- or similar products from other Manufacturers
like TALKEN, etc.). Using a metallic brush remove oxidation and rust if present, clean with
acetone, chloroform or similar oil free solvent and live it to dry. Apply one or two pass of
spray zinc, having care to cover uniformly all the exposed surfaces (this apply specifically
the clamp brackets). Carefully follow the indications of the spray zinc Manufacturer.
The spray contain Toluene: flammable, do not expose to fire, do not smoke, do not dry with direct
flame or hot air irons at temperature higher than 80°C. Vapors can cause irritation and narcotic
effects, protect with mask and gloves.
GENERAL INSTALLATION INSTRUCTION