  9. Wizmart NB338 Series Quick start guide

Wizmart NB338 Series Quick start guide

WIZMART NB338 Photoelectric Smoke Detector
Installation Wiring Diagram
TYPICAL WIRING DIAGRAM
Figure 1(a) shows the typical wiring diagram of the
2-wire multiple-station smoke detector system.
INITIATING
LOOP
EN54 LISTED
COMPATIBLE
CONTROL
PANEL
+
-
FIRST DETECTOR BASE LAST DETECTOR BASE
EOL
RESISTOR
5
252
61 34 61 34
+-+
REMOTE
INDICATOR
CLASS A OPTIONAL WIRING
N
O
TE: IF REM
O
TE INDI
C
AT
O
R I
S
N
O
T
US
ED. P
O
LARITY T
O
DETE
C
T
O
R MAY BE REVER
S
ED.
-
DO NOT PLACE LINKS BETWEEN THE WIRING POSITIONS
OF TERMINALS 2 AND 5 TO PROVIDE POWER
SUPERVISION
Figure 1(b) shows the typical wiring diagram of the
4-wire multiple-station smoke detector system.
DO NOT PLACE LINKS BETWEEN THE WIRING POSITIONS
OF TERMINALS 2 AND 5 TO PROVIDE POWER
SUPERVISION
WARNING
TO PREVENT DETECTOR CONTAMINATION AND
SUBSEQUENT WARRANTY CANCELLATION, THE
SMOKE DETECTOR MUST REMAIN COVERED UNTIL
THE AREA IS CLEAN AND DUST FREE.
INSTALLING THE BASE
1. To insure proper installation of the detector head to the
base, all the wires should be properly addressed at
installation:
(A) Position all the wires flat against terminals.
(B) Fasten the wires away from connector terminals.
2. If you use a jumper wire to connect the poles of
terminal 2 and 5 when testing the detector loop
continuity, be sure to remove the jumper wire prior to
the installation of the detector head.
3. The end-of-line device shown in fig. 1(a) and 1(b)
should be compatible with the control unit. The
end-of-line supervisory relay used should be rated for
the DC power voltage used.
4. Open area smoke detectors are intended for mounting
on a ceiling or a wall in accordance with the fire
standard in your country.
5. The base of the smoke detector can be mounted
directly onto an electrical junction box such as an
octagonal (75mm, 90mm or 100mm), a round (75mm),
or a square (100mm) box without using any type of
mechanical adapter.
INSTALLING THE HEAD
1. Align the components as shown in Figure 2.
2. Mate the detector head onto the base and twist
clockwise to secure it.
3.Do not install the detector head until the area is
thoroughly cleaned of construction debris, dusts, etc.
The maximum number of smoke detector installed in
the same loop is 30 units.
Fig. 2 Mating detector head onto base
ADJUSTING THE RELAY FOR NO/NC
The normal condition for the relay is “normally open”
(NO).
1. To adjust the normal condition of the relay to
“normally closed”(NC), insert a screwdriver into the
rectangular hole located on the side between the front
cover and base and rotate to remove the front cover.
2. Refer to figure 3. There is a jumper head next to the
relay on the PCB. Remove the jumper head and reinsert
it in the NC position.
3. Carefully replace the front cover.
Relay contact rating:
1A@30VDC,
0.5A@125VAC.
TESTING
1.All the alarm signal services, releasing device and
extinguisher system should be disengaged during the
test period and must be re-engaged immediately at the
conclusion of testing.
2. After energizing the detector head for approximately
one minute, check to see the indicator green LED
flashing once every 3~5 seconds. If green LED fails to
flash, it indicates the non-functioning of the detector or
faulty wiring. Re-check the wiring or replace the
detector if necessary.
3. Allow smoke from a cotton wick or a test smoke
aerosol to enter the detector-sensing chamber for at
least 10 seconds. When sufficient smoke has entered
the chamber, the detector will signal an alarm, this
being visible by a continuous illumination of the LED.
Reset each detector and/or control unit before
attempting to test any additional detectors in the same
zone. If the alarm fails in this step, it indicates a
defective unit, which requires service.
Fig. 3 Schematic of detector structure
When front cover is open.
HEAT SENSOR TESTING
The detector to be tested should be subject to a flow of
warm air at a temperature of between 65°C and 80°C.
(This requirement can be met by some domestic hair
dryers).
Proceed as follows:
1. Switch on the warm airflow and check that temperature
is correct and stable.
2. From a distance of several inches, direct the airflow at
the guard protecting the thermistor. The detector
should alarm within 30 seconds.
3. Upon alarm immediately remove the heat source and
check that the red LED of the detector is illuminated.
Reset the detector from the control panel.
4.If detector fails to go into alarm mode within 30
seconds it is too insensitive and needs to be returned
to the distributor for servicing.
5. After testing, check that the system is set for normal
operation and notify the appropriate authorities that the
testing operation is complete and the system is active
again.
NOT SUITABLE FOR INSTALLATION IN AREAS
WHERE AIR VELOCITIES EXCEED 300 ft/min
MAINTENANCE
The recommended minimum requirement for detector
maintenance consists of an annual cleaning of dust from
the detector head by using a vacuum cleaner cleaning
program should be agreed to the individual environment
in conformance with NFPA-72A standard.
CAUTION: DO NOT ATTEMPT TO DISASSEMBLY OF THE
FACTORY SEALED SMOKE DETECTOR. THIS
ASSEMBLY IS SEALED FOR YOUR PROTECTION AND IS
NOT INTENDED TO BE OPENED FOR SERVICING BY
USERS. OPENING THE DETECTOR HEAD WILL VOID
THE WARRANTY.
REFERENCE TO THE TECHNICAL BULLETIN ISSUE NO.
NBTB20031106,REV.A
SPECIFICATION
Model 2/4
wire Ther
mal Voltage
DC Standby
Current
(Max.)
Alarm
Current
(Max.)
Surge
Current
(Max.)
Star-Up
Time
(Max.)
Permissible
Current
(Max.)
Frequency Alarm
Sound level Alarm contact Base model
NB338-2 2 28/12V
90μA 70mA 120μA60 Seconds 80mA 3-5 Seconds - P/N772912
NB338-2L 2 28/12V 90μA 70mA 120μA60 Seconds 80mA 3-5 Seconds - P/N774912
NB338-4-12 4 12V
320μA 35mA 120μA60 Seconds 80mA 3-5 Seconds - Form A P/N774912
NB338-4-24 4 24V
320μA 35mA 120μA60 Seconds 80mA 3-5 Seconds - Form A P/N774912
NB338-2H 2 57°C 28/12V 100μA 70mA 130μA60 Seconds 80mA 3-5 Seconds - P/N772912
NB338-2HL 2 57°C 28/12V 100μA 70mA 130μA60 Seconds 80mA 3-5 Seconds - P/N774912
NB338-4H-12 4 57°C 12V 320μA 35mA 130μA60 Seconds 80mA 3-5 Seconds - Form A P/N774912
NB338-4H-24 4 57°C 24V 320μA 35mA 130μA60 Seconds 80mA 3-5 Seconds - Form A P/N774912
Remarks: H-heat/ L-remote LED indicator output
LIMITED WARRANTY STATEMENT
WIZMART TECHNOLOGY, Inc. represents that this product is free from defects in material and workmanship. And it will
repair or replace any product or part thereof which proves to be defective in workmanship or material for a period of twelve
(12) months from the date of purchase but not to exceed eighteen (18) months after shipment by the manufacturer. For a full
description of WIZMART TECHNOLOGY’S LIMITED WARRANTY, which, among other things, limits the duration of
warranties of merchantability and fitness for a particular purpose and excludes liability for consequential damages. Please
read the entire LIMITED WARRANTY on the WIZMART quotation. Acceptance of order and/or original invoice which will
become part of your sales agreement. Please contact WIZMART TECHNOLOGY directly for a return merchandise
authorization (RMA) number before returning goods to the factory. Shipment must be prepaid and WIZMART will repair or
replace your returned detector.

This manual suits for next models

8

Popular Smoke Alarm manuals by other brands

Honeywell SS4-AS Installation guide and operating manual

Honeywell

Honeywell SS4-AS Installation guide and operating manual

Smartek NB40LPS1 manual

Smartek

Smartek NB40LPS1 manual

System Sensor WMSOU-RR-P01 installation instructions

System Sensor

System Sensor WMSOU-RR-P01 installation instructions

Det-Tronics X3300 instructions

Det-Tronics

Det-Tronics X3300 instructions

NEAT Electronics SMOKE user manual

NEAT Electronics

NEAT Electronics SMOKE user manual

Siemens OH921 installation instructions

Siemens

Siemens OH921 installation instructions

olympia electronics BSR-6055 quick start guide

olympia electronics

olympia electronics BSR-6055 quick start guide

DMP Electronics 1165 Installation sheet

DMP Electronics

DMP Electronics 1165 Installation sheet

Emos P56502 manual

Emos

Emos P56502 manual

System Sensor 2012H Installation and maintenance instructions

System Sensor

System Sensor 2012H Installation and maintenance instructions

Comelit 48BFC000 manual

Comelit

Comelit 48BFC000 manual

Code one A owner's manual

Code one

Code one A owner's manual

Firex A manual

Firex

Firex A manual

Bellman & Symfon BE1287 user manual

Bellman & Symfon

Bellman & Symfon BE1287 user manual

Nexa FS-558/RF manual

Nexa

Nexa FS-558/RF manual

DSC WS4916 Series Installation and operation instructions

DSC

DSC WS4916 Series Installation and operation instructions

Firex 242 Specification sheet

Firex

Firex 242 Specification sheet

First Alert SA710AB Product specifications

First Alert

First Alert SA710AB Product specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.