WorkPro BLS2 LITE MKII User manual

BLS2 LITE MKII
User Manual
Version1.1

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 1
SAFETY INSTRUCTIONS
1. Read this manual carefully.
2. Follow all instructions and warnings.
3. Only use accessories specified by WORK PRO.
4. Follow the safety instructions of your country.
5. Be careful with sound levels.
SYMBOLS
The following symbols are used in this document:
This symbol indicates a potential risk of harm to a person or damage to the product. You
can also notify the user of the instructions that must be followed strictly to ensure the
installation or safe operation of the product.
This symbol notifies the user about the instructions that must be followed strictly to ensure
the correct installation or operation of the product.
This symbol notifies the user about additional information or optional instructions.
WELCOME TO WORK PRO
Thank you for choosing the BLS2 LITE MKII system from WORK PRO.
This document contains essential information on the use of the system. Read this document carefully to
become familiar with the system.
Please check the WORK PRO website regularly to download the latest version of the document and
software updates: https://www.workpro.es/

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 2
CONTENT
1. INTRODUCTION.................................................................................................................................3
2. Components of the BlueLine Digital MKII System ............................................................................4
3. AUDIO SENDERS................................................................................................................................4
3.1.1. Audio streaming formats ............................................................................................ 4
4. BLS2 LITE MKII...................................................................................................................................5
Features .....................................................................................................................................6
Device description......................................................................................................................6
4.2.1. Display ......................................................................................................................... 7
4.2.2. Analog audio input ...................................................................................................... 8
4.2.3. LAN port ...................................................................................................................... 8
4.2.4. Main supply input........................................................................................................ 9
Device setup...............................................................................................................................9
4.3.1. Setup through WorkCAD3 Configurator ..................................................................... 9
Accessories...............................................................................................................................11

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 3
1. INTRODUCTION
The devices of the BlueLine Digital MKII series allow the streaming of audio over IP through
Ethernet, complying with the TCP / IP protocol stack. Using the BlueLine Digital MKII system
it is possible to perform from a simple point-to-point audio transmission to a complex multi-
channel system with alarm control and management.
BlueLine Digital MKII can make use of the existing physical network infrastructure in the
installation, due to its low bandwidth consumption. On the other hand, it is compatible with
commonly used low or high impedance amplification systems.
Thanks to the modular design of the system, BlueLine Digital MKII adapts perfectly to the
features of each installation, being able to expand the system in the future if the
characteristics of the installation require it.
Features:
•Management of audio strteamers and receivers.
•Different types of coding (PCM, MP3).
•Different audio extraction modes (Dual, Single, Mono).
•Control by OSC commands.
•Control by GPIO.
•Complement with the family of Light Mouse devices.
•Real-time system monitoring.
•Configuration by software.
•External power supply or PoE.

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 4
2. Components of the BlueLine Digital MKII System
In this chapter you will find information about the different devices that make up the BlueLine
Digital MKII system.
The BlueLine Digital MKII system has four kinds of devices:
STREAMERS
BLS2 LITE MKII
One stereo channel sender
BLS2 SD MKII
One stereo channel sender with SD player
RECEIVERS
BLR2 LITE MKII
One stereo channel receiver
BLR2 MKII
One stereo channel receiver with 2xGPIs/2xGPOs
BLR2 A plus MKII
One stereo channel receiver with
2xGPIs/2xGPOs and low impedance amplifier
PAGING
SPS 8
Paging station
WALLMOUNT
CONTROLLERS
BLC 1
Wallmount controller for local receiver
WNC 1
Wallmount controller through the network
WAC 7
Customizable wallmount controller
Note: The BlueLine Digital MKII series is compatible with the previous series of devices, so you
can include devices of both series in your installation.
3. AUDIO SENDERS
The BlueLine MKII senders are devices that are responsible for transmitting a stereo audio
channel to the network. There are two types of senders:
- BLS2 LITE MKII: Transmitter of a stereo channel with analog input.
- BLS2 SD MKII: Transmitter of a stereo channel with SD player and analog input.
The BlueLine senders consume bandwidth continuously, regardless of whether you connect
anything to its analog input or do not reproduce anything through the SD module.
The BlueLine senders (BLS2 LITE MKII and BLS2 SD MKII) can transmit audio without coding
or with coding, the audio format chosen will depend on the needs of your installation.
Depending on the chosen audio format, the bandwidth consumption by the senders will be
different.
The following is the maximum number of devices that you can use in a dedicated subnet, with
a bandwidth of 25Mbps.
PCM
Up to 16 stereo channels for 25Mbps dedicated bandwidth.
MP3
Up to 64 stereo channels for 25Mbps dedicated bandwidth.
3.1.1.
Audio streaming formats

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 5
Next, the features of each audio format and its bandwidth consumption are detailed:
-PCM: Format of audio digitization without losses. This implies that it is the format with
the highest audible quality and with the highest bandwidth consumption, 1.5 Mbps
per sender.
-MP3: Audio coding format with losses, that making use of psychoacoustic techniques,
manages to reduce the amount of information to be transmitted with the minimum
audible degradation. It has a bandwidth consumption of 220 Kbps per sender.
The number senders in an installation with BlueLine Digital MKII devices will depend
on the available bandwidth of the subnet.
It is recommended to make use of the multicast filtering (IGMP snooping) in the switches of
your LAN, to make an efficient consumption of the bandwidth. Review the Network & OSC
manual for detailed information.
4. BLS2 LITE MKII
The BLS2 LITE MKII is an audio sender of one stereo channel, with unbalanced input, that
supports PCM / MP3 audio modes. The device can be powered by either PoE or external
power supply.

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 6
Features
Analog audio input
Number of channels
1 stereo channel (unbalanced)
Audio connector
Euroblock, 3 pin 5.08mm
Input sensitivity
0.7 dBu (840mVrms)
Network
Connector
RJ-45
Audio over IP
BlueLine UDP datagrams
Ethernet
100 base TX
Main supply
External power supply
12/24 Vdc (Not included)
PoE Class
Class 0 802.3af
Consumption
1.5 W
General
Control protocol
OSC
Audio streaming formats
PCM/MP3
Dimensions
109mm×133.75mm×40.45 mm
Weight
360 g
Device description

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 7
1. Reset button. Take the device to its factory configuration
2. Next button. It allows to advance between and through the different screens of the
display.
3. Display. It shows different features of the device.
4. Set button. It allows access to a certain display screen and set the digits of the different
screens.
5. LAN port. Connection port to the local network, RJ45.
6. Main supply input. 12/24 Vdc
7. Analog audio input. Unbalanced audio input, 3-pin Euroblock of 5.08 mm.
On the front of the device you will find a display through which you can view or modify different
parameters of the unit.
To navigate between the different parameters press the NEXT button if you want to edit any of
these parameters, press the SET button to access it. Next, specify which parameters are editable
and which are not:
-STATIC IP, editable.
-DYNAMIC IP, not editable.
-MAC, not editable
-SRC, editable.
STATIC IP, this is the static IP address. The device has a static IP address by default in the
subnet 10.0.0.0/8. For editing, use the SET (to select and set the digit) and NEXT (for editing
upwards) buttons.
NOTE: After a change, the device restarts to confirm the value.
DYNAMIC IP, this is the dynamic IP address of the device, which is assigned by a DHCP server.
MAC, this is the physical address of the device.
4.2.1.
Display

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 8
SRC, it refers to the channel (Source) in which the device transmits.
For editing, use the SET (to select and set the digit) and NEXT (for editing upwards) buttons.
The analog audio input of the device is unbalanced, keep in mind the following type of
connection:
STEREO
MONO
RJ45 port for LAN connection. Allows PoE power (Class 0 802.3af).
Next to the RJ45 connector you will find two LEDs indicating the status of the device:
LINK (green)
Indicates that the BLS2 LITE MKII is connected to the LAN
ACT (orange)
Indicates that packets are being sent or received
4.2.2.
Analog audio input
4.2.3.
LAN port

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 9
Power input for external power supply. The admitted voltage can be between 12/24 Vdc,
with a minimum current of 500 mA.
Check the current polarity before connecting the main supply
The external power supply is not provided with the device.
Device setup
The configuration of the device can be done by software (WorkCAD3 configurator) or through
display. The most comfortable way for the user is through WorkCAD3 configurator, since he
will have access to all the functionalities of the device and he can also see the interaction of
the device with the rest of the BlueLine Digital MKII network elements.
After making the IP level configuration of the device and updating it if would be necessary
(see WorkCAD3 Configurator manual), proceed with its setup.
If you click on the device with the left mouse button, the configuration interface will be opened
and the following parameters will appear:
4.2.4.
Main supply input
4.3.1.
Setup through WorkCAD3 Configurator

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 10
-Zone: This field refers to the zone to which the device belongs, in order to receive
OSC control commands. By default, all BlueLine senders are in zone -1. It is
recommended not to modify the zone in the senders.
-Channel: Channel number where the audio is emited. By default, all the senders are
in channel 0. In the case that there is more than one sender, you must modify the
channel in order to avoid conflicts, since only one sender can exist per channel.
-Parameters:
•PCM: Audio streaming without coding.
•MP3: Audio streaming with MP3 coding.
•Disable IGMP Query on source: Disable the IGMP querier in the case
that the sender is emitting on channel 0.

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 11
Accessories
The BLS2 LITE MKII includes a series of accessories for mounting on a wall or with the rack
accessory BL AR 19 (not included):
-2x Wings for mounting in a wall.
-4 screws.
-1x Bar to joint two devices.
- Optional –
BL AR 19
Fixing accessory for standard rack 19" 1 HU to accommodate up to 4 devices of the Blueline
MKII series.

BLS2 LITE MKII
USER MANUAL
VERSION 1.1
BLUELINE DIGITAL MKII SERIES www.workpro.es 12
This manual suits for next models
1
Table of contents