Workzone 11334 User manual

ELECTRICAL
Stud
Detector
User Guide

Contents
Welcome Section
General Information & Safety
Instructions
Contents & Features
General Layout
Setting Up
• Installing The Battery
• Turning On/O
Operating
• Selecting A Mode
• Calibrating Before Use
• Stud Scanning Mode
• Stud Scanning On Dierent Surfaces
• Metal Scanning Mode
• AC Power Cable Scanning Mode
Trouble Shooting
Specifications
1.
2-3.
4.
5-6.
7.
8-13.
14.
15.
Copyright © 2018-2019 Thunderbolt Photography, Richard Ross. All rights reserved.
All Photos and Illustrations may not be reproduced or used in any manner whatsoever without the express
written permission of the copyright holder.

1.
Welcome Section
Congratulations!
You have made an excellent choice with the purchase of this quality WORKZONE®
product.
By doing so you now have the assurance and peace of mind which comes from
purchasing a product that has been manufactured to the highest standards of
performance and safety, supported by the high quality standards of Quesh Ltd.
We want you to be completely satised with your purchase, so this WORKZONE®
product is backed by a comprehensive manufacturer’s 3 year warranty and
outstanding after sales service through our dedicated helpline.
We hope you enjoy using this product for many years to come.
If you require technical support or in the unlikely event that your purchase is
faulty, please telephone our helpline for immediate assistance. Faulty product
claims made within the 3 year warranty period will be repaired or replaced free
of charge provided that you have a satisfactory proof of purchase.
(keep your receipt safe)
This does not aect your statutory rights. However be aware that the warranty
will become null and void if the product is found to have been deliberately
damaged, misused and/or disassembled.

General Information &
Safety Instructions
This Stud Detector is powered by a 9V square battery.
Do not dispose of batteries in your household waste.
Please contact your local authority for details on safe disposal.
Do not expose this product to damp or moist conditions.
• Never throw batteries into a re or expose to excessive heat sources.
• If batteries are swallowed, please seek immediate medical attention.
• Always ensure correct +/- battery polarity when installing batteries.
• Do not recharge non-rechargeable batteries.
Equipment, which is marked with the WEEE logo
(as shown on the left), should not be thrown away with your household
waste. Contact your local authority waste disposal department, as they
will be able to provide details of the recycling options available in your
area.
Electrical and electronic equipment (WEEE) contains materials, parts
and substances, which can be dangerous to the environment and
harmful to human health if the waste of electrical and electronic
equipment (WEEE) is not disposed of correctly.
Equipment, which is marked with the WEEE logo
(as shown on the left), should not be thrown away with your household
waste. Contact your local authority waste disposal department, as they
will be able to provide details of the recycling options available in your
area
The EU Declaration of Conformity
can be downloaded from www.quesh.co.uk.
2.

3.
General Information &
Safety Instructions
WARNING
DO NOT rely exclusively on the detector to locate items behind scanned
surfaces. Use information sources such as plans, visible electrical and pipe
outlets/entry points to locate objects before penetrating the surface.
• DO NOT assume that there is no live cabling within a wall.
• DO NOT take actions that could be dangerous.
• ALWAYS disconnect power, gas and water before penetrating a surface.
Failure to follow these directions may result in electrical shock, re and/or
serious injury/property damage.
Live AC Cable Detection
The detector has constant AC power cable warning alert that works in all modes.
When a live AC source is detected the icon will appear on the screen.
Exercise extreme caution in this circumstance where AC power is present.
General Product Care
• Keep the Stud Detector dry and clean
• Avoid shock, vibrations and extreme heat
• Check the battery before use
• Please remove the battery for long term storage

4.
Contents & Features
Contents
1 x Stud Detector
1 x 9V Battery
1 x User Guide
Features
• Detects wood, metal and unshielded AC cables
• Scans up to a depth of 2.36” (60mm)
• 3 preset stud depths
• 3 material presets
• Easy calibration
• Backlit screen
• Low power warning
• Battery powered
NO USER SERVICEABLE PARTS INSIDE

5.
General Layout
On/O
Calibrate
Screen
Mode
Centre Mark
STUD DETECTOR

6.
General Layout
SCREEN ICONS
1 Inch
Scan Depth
½ Inch
Scan Depth
Move Right
Metal Mode
1½ Inch
Scan Depth
Low Power
Move Left
AC Power
Mode
Wood Mode AC Power
Cable
Edge
Indicator
Left Edge
Indicator
Right Edge
Indicator
Center
Indicator

7.
Setting Up
Installing The Battery
This product is supplied with a 9V battery. To t the battery please remove the
battery from it’s wrapper. Open the battery bay by pushing the tab towards the
top of the detector on the battery cover and lifting the cover up.
Connect the 9V battery to the correct terminals and place it in the battery bay.
Replace the battery cover by inserting the holding pins rst at the top of the bay
and closing the cover down so the tab locks in to place.
Turning On/Off
To turn the Stud Detector on or o, give the ‘On/O’ button a quick press. If the
Stud Detector is left unused for 3 minutes, it will turn itself o.

8.
Operating
Selecting A Mode
The Stud Detector has three modes of use:
• Stud Detection
• Metal Detection
• AC Power Detection
You will need to repeatedly press the button to cycle through the available
modes to make your selection.
The options will be:
> > > >
The rst three options are for stud detecting at dierent depths, which are ½”
(12.7mm), 1” (25.4mm) and 1 ½” (38.1mm).
The forth option is for detecting metal, such as ½” rebar up to a depth of 2.36”
(60mm).
The nal option is for detecting AC power cables up to a depth of 2” (51mm).
Calibrating Before Use
After a mode has been selected you will need to calibrate the detector.
THIS MUST BE DONE EVERY TIME THE DETECTOR HAS BEEN TURNED
ON FOR USE. To do this place the detector at against any surface, but away
from AC cable and metal. Press and hold the ‘Calibrate’ button on the side of the
hand grip until you see the indicator bar drop on the screen and a beep can be
heard. Wait 2-3 seconds before use.
WARNING
DO NOT rely exclusively on the detector to locate items behind scanned
surfaces. Use information sources such as plans, visible electrical and pipe
outlets/entry points to locate objects before penetrating the surface.
Other manuals for 11334
2
Table of contents