2
The indictor A is red when power is on
The indictor A is red and flashing when receiving the wireless signal
The indictor A is green and flashing when in code pairing mode
The indictor B is green when calling for heat
The indictor B is red when set to external limitation protection
The indictor B red flashing shows a sensor error
The indictor B green flashing shows entering the external limitation value select
Press the button for 8 seconds untill the indictor B flashes green,the receiver is now in
external probe limitation setting mode.
Press the button softly to cycle between the following four states.
Indicator A - green shows external limited at 30oC
Indicator A - red shows external limited at 40oC
Indicator A - yellow shows external limited in 55oC
Indicator A - without light shows no external limitation set.
The receiver will save current setting automatically when nothing is pressed for 8 seconds and will
quit the limitation setting mode.
Green Calling for heat
Red Limitation protective
Red ashing Sensor ERR
Green ashing Selected the limitation value
Green ashing Entering limitation value selected
Red Power
Red Flashing Receiving Signal
Green Flashing Code Pairing State
Green external limited at 30°C
Red external limited at 40°C
Yellow external limited at 55°C
None external limited closed
Description of work state Limitation value select (for external probe (if used))
Indicator A
Indicator A
Indicator B
Indicator B
Button
Press for
8 sec
*All wiring must be completed by a qualified professional in line with current regulations
E06
E8.413RF/E8.423RF Wireless Receiver (Single Zone)
✆ 0800 5420 816 www.wundatrade.co.uk
THE BRAND YOU CAN TRUST
Revision Date: 30/04/2018