manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wunda
  6. •
  7. Receiver
  8. •
  9. Wunda E06 User manual

Wunda E06 User manual

Popular Receiver manuals by other brands

Televes ZAS HD SAT user manual

Televes

Televes ZAS HD SAT user manual

Realistic DX-75 Operating and service instructions

Realistic

Realistic DX-75 Operating and service instructions

Saris 4620 Assembly instructions

Saris

Saris 4620 Assembly instructions

Mini DTR 206C PVR user manual

Mini

Mini DTR 206C PVR user manual

RF Elements TwistPort manual

RF Elements

RF Elements TwistPort manual

Denon DN-200WS user guide

Denon

Denon DN-200WS user guide

Yamaha RX-V467 owner's manual

Yamaha

Yamaha RX-V467 owner's manual

Russound SaphIR 858 instruction manual

Russound

Russound SaphIR 858 instruction manual

Quasonix RDMS Firmware update procedure

Quasonix

Quasonix RDMS Firmware update procedure

Pioneer XV-HTD1 Service manual

Pioneer

Pioneer XV-HTD1 Service manual

ATZ HDMI-V2-44HE150 manual

ATZ

ATZ HDMI-V2-44HE150 manual

Sony XNV-770BT MyTomTom Specifications

Sony

Sony XNV-770BT MyTomTom Specifications

Grundig STR 7122 TWIN Service manual

Grundig

Grundig STR 7122 TWIN Service manual

Creative Blaster Modem user guide

Creative

Creative Blaster Modem user guide

Panduit ATLONA AT-OME-RX11 installation guide

Panduit

Panduit ATLONA AT-OME-RX11 installation guide

VOLTCRAFT UTPS-40 operating instructions

VOLTCRAFT

VOLTCRAFT UTPS-40 operating instructions

JVC KW-ADV794 instructions

JVC

JVC KW-ADV794 instructions

Litelink VT-1001 operating instructions

Litelink

Litelink VT-1001 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Mounting Steps
1: Release the front cover by inserting a screwdriver into
bottom channel and twisting.
3: Mount the backing plate in the wall socket using
a screwdriver and screws supplied.
2: To release backing plate, slide wire retaining clip upwards.
4: After connecting the receiver as per wiring diagram (see diagram)*, mount the thermostat on to the
backing plate and push down wire retaining clip, remount the frame.
*All wiring must be completed by a qualified professional in line with current regulations
Wiring Diagram
Potential free
output
Main control
circuit
E06
E8.413RF/E8.423RF Wireless Receiver (Single Zone)
✆ 0800 5420 816 www.wundatrade.co.uk
THE BRAND YOU CAN TRUST
Revision Date: 30/04/2018
2
The indictor A is red when power is on
The indictor A is red and flashing when receiving the wireless signal
The indictor A is green and flashing when in code pairing mode
The indictor B is green when calling for heat
The indictor B is red when set to external limitation protection
The indictor B red flashing shows a sensor error
The indictor B green flashing shows entering the external limitation value select
Press the button for 8 seconds untill the indictor B flashes green,the receiver is now in
external probe limitation setting mode.
Press the button softly to cycle between the following four states.
Indicator A - green shows external limited at 30oC
Indicator A - red shows external limited at 40oC
Indicator A - yellow shows external limited in 55oC
Indicator A - without light shows no external limitation set.
The receiver will save current setting automatically when nothing is pressed for 8 seconds and will
quit the limitation setting mode.
Green Calling for heat
Red Limitation protective
Red ashing Sensor ERR
Green ashing Selected the limitation value
Green ashing Entering limitation value selected
Red Power
Red Flashing Receiving Signal
Green Flashing Code Pairing State
Green external limited at 30°C
Red external limited at 40°C
Yellow external limited at 55°C
None external limited closed
Description of work state Limitation value select (for external probe (if used))
Indicator A
Indicator A
Indicator B
Indicator B
Button
Press for
8 sec
*All wiring must be completed by a qualified professional in line with current regulations
E06
E8.413RF/E8.423RF Wireless Receiver (Single Zone)
✆ 0800 5420 816 www.wundatrade.co.uk
THE BRAND YOU CAN TRUST
Revision Date: 30/04/2018
3
Code pairing method
On Thermostat (E8.2RF) enter the advanced settings by first switch off thermostat by pressing then hold while
switching thermostat back on . Next Press 4 times untill the following is displayed.
On Receiver press the button for 4 secs then release, indicator A will flash green , the
receiver is now ready to be code matched.
(NOTE: Indicator light will go out after 30 seconds of inactivity and process
will need repeating)
On thermostat press and will flash 3 times and then go out, the indicator
light A will turn back to red indicating that code match has been successful.
Selection Table
Your notes:
Parameters
Voltage : AC230V
Current : Max 3A
Wireless Frequency Output: 433Mhz
Effective Transmission Distance: 200m empty space
External Limatiation Valve : 30°C,40°C and 50°C
(if external probe is fitted)
Factory Setting : 30°C
Limitation Switch Differentail : -2°C
Ambient Temperature : -5~50°C
Protective Housing: Ip20
Housing Material: Anti-Flammable PC
Model Current Output Type
E8.413RF 3A One receiver, built-in & floor sensor
One receiver, built-in & floor sensor with potential free output
3AE8.423RF
*All wiring must be completed by a qualified professional in line with current regulations
E06
E8.413RF/E8.423RF Wireless Receiver (Single Zone)
✆ 0800 5420 816 www.wundatrade.co.uk
THE BRAND YOU CAN TRUST
Revision Date: 30/04/2018
4
Your Notes:
Tech support opening hours are subject to change - please visit our website for the latest information
Revision Date: 30/04/2018