Technical changes reserved. 1/ 2 947-QR-002-E
Quick Reference Multi TC Release 1.0
WYLER AG
Im Hoelderli 13 E-Mail: wyler@wylerag.com Outside Switzerland:
8405 Winterthur Tel. +41 52 233 66 66 contact our representatives
Switzerland Website: www.wylerag.com www.wylerag.com/en/contact/representatives/
Thank you for choosing WYLER!
Read this quick reference before start working with the Multi TC.
Please note the safety instructions.
Brand and Type
Brand: Multi TC
Type: 065-003-000-001
Warning! The following sign is used in this Quick Reference:
This is intended to indicate special danger.
Safety instructions
The Multi TC complies with the applicable directives and standards, see:
-This Quick Reference
-The type label
- The CE Declaration of Conformity at www.wylerag.com
Intended Use
-The MultiTC is a system component and interface. It is designed exclusively to connect WYLER products
which are equiped with WyBus dll.
-Attention!: There is no other use allowed!
Not intended use
-Do not use as a hammer!
-Do not throw the device! The housing can cause serious injury.
-Do not use this device near sources of strong electromagnetic energy Radiation (e.g.,
unshielded radio frequency source) because they can interfere with operation.
DC-Characteristics Common Characteristics
Characteristics Value Characteristics Value
Power Supply +24V 12 – 30 V Interfaces RS232 on Port 0
Power Supply +5V 4.5 – 5.5 V RS485 on Port 1,2,3,4
Power Consumption max. 450 mW Connectivity Wyler USB-Cable
Input Low Voltage 0.8V wylerCONNECT
Input High Voltage 2.4V Temp. (Operation and use) -40 .. 85° C
Dimensions: Pinout Port 0:
Pinout Port 0, 1, 2, 3, 4:
Please Note: To lock the connectors, the
threaded ring is tightened until it is ‘finger-