XtendLan XL-DM317G User manual

XL-DM317G
User manual

Contents
Chapter I Summary and System Structure..........1
1. Summary ......................................................................1
2. Checking the Package..................................................2
3. SafetyWarning and Attentions....................................... 4
4. General Operation Standards andAttentions................6
4.1. Operation Standards................................................ 6
4.2. Attentions.................................................................. 7
5. Structures and Functions..............................................9
6. Instructions of Fixed Icon DisplayArea ..................... 16
7. Charging Battery Icon ............................................... 17
8. Install TF Card ........................................................... 17
9. Install UIM/SIM Card ................................................. 18
10. Battery Usage ......................................................... 19
11.Main Specification of the Equipment ....................... 22
Chapter II Specifications and Functions ......... 23
1. Technical Specifications .............................................23
1.1 Rf Performance Index .......................................... 23
1.2. xDSL Index (optional) ........................................ 23

1.3. Optical Power Index (optional) ........................... 24
1.4. Visual Fault Locator (optional) ........................... 24
2. General Functions .................................................. 25
2.1. On/Off ................................................................ 26
2.2. Standby and Wakeup.............................................25
2.3. Table Management .............................................26
2.4 Open / Close net card ......................................... 30
2.5 PPPoE dial .......................................................... 31
2.6 Task Manager ......................................................32
2.7 Dialer ................................................................. 33
2.8 Answer the phone ............................................... 34
2.9 Input Method ....................................................... 35
2.10 Flashlight .......................................................... 38
2.11 Camera ............................................................. 38
2.12 Breathing indicator ............................................ 38
2.13 Mass storage mode .......................................... 38
2.14 Headset ............................................................ 40
2.15 Vibration ............................................................ 40
2.16 GPSone Passive positioning ............................. 41
2.17 WIFI hotspot ...................................................... 41

Chapter III Usage of Main Functions ............. 43
1 Test Functions .............................................................44
2. SN Code ................................................................... 66
3. Test Setting ................................................................68
4. Records ..................................................................... 73
5. Read Serial ............................................................... 74
6. Control of the electric quality and wireless dial ......... 75
7. Web ........................................................................... 77
8. Dialer ......................................................................... 79
9. Contacts .................................................................... 80
10. Messaing ................................................................. 82
11.Clock ....................................................................... 83
12. Calendar ................................................................. 85
13. Settings ................................................................... 86
14. Camera ................................................................... 94
15. Gallery ..................................................................... 96
16. My Files ................................................................... 97
17. Calculator .............................................................. 100
18. Video ..................................................................... 100
19. Music ..................................................................... 101

20. Recorder ............................................................... 103
21. Downloads ............................................................ 104
22. G-Sensor Calibration ............................................ 104
23. How to Install and Uninstaill Software ................... 105
24. How to Install the USB Driver ............................... 107
Chapter IV Usage and Maintenance ............... 110
Chapter V Faults and Solutions ..................... 112
Chapter VI market ........................................... 115
1. Summary ................................................................ 115
2. Components ............................................................ 115
3. Usage of Main Functions ........................................ 116
3.1 Download software package ........................... 116
3.2 Installation and Update ................................... 119
3.3 Remarks ........................................................... 120
3.4 Feedback .......................................................... 121
4. Trouble Shooting ...................................................... 123
Chapter VII The Instruction of Program
Installation after Resetting ...... 125

XL-DM317G Multi-service Access
Test PDA
6
Chapter I
Summaryand System Structure
1.
Summary
XL-DM317G is designed for meeting entire
network
requirement, whose functions including WFMS processing,
wireless signal collection, GPS positioning, xDSL test, LAN test,
optical power test, visual fault locator, tracing and PDA. XL-
DM317G has wireless voice and communication module, which
can logon Internet through wireless network, and finish the
task quickly. Meanwhile, collecting all kinds of specifications
of wireless signals, upload to server, achieve some test
functions. And also test all kinds of xDSL line (xDSL includes
ADSL, ADSL2, ADSL2+, READSL etc.),
LAN test. It not only can test xDSL physical layer
parameters to confirm whether the line is proper to provide
xDSL service or not; but also evaluate the quality of the
service you provide. The tester can emulate the user’s PC to
test broadband IP line or perform PPPoE dial through user’s
Modem in order to test the connectivity of IP network and the
problem of user’s Modem or eliminate malfunctions that leads to
failing logon Web Pages caused by user’s PC. XL-DM317G
adopts 480*800 TFT IPS true color LCD resistive touch
screen, and embedded with Android 4.1.2 JB operation system.
It is easy to operate and check the test

XL-DM317G Multi-service Access
Test PDA
7
results. It can meet the installation and maintenance
requirements of wireless device, xDSL access, LAN access
and optical access and so on. Meanwhile, it’s a powerful
tool for improving the efficiency of maintaining Internet.
StandardAccessories:
Please make sure all the following accessories are in
good condition:
Charger Direct Ethernet Network line
USB data line Touch Pen
Touch pen rope Carrying Bag

XL-DM317G Multi-service Access
Test PDA
8
User Manual
OtherAccessories:
(It is different due to different modules.)
Test Line USB inverting power line
Tracing receiver Belt
2.
SafetyWarning and Attentions
In order to use the tester safely and efficiently, please
read the following information before using.
➢
Please use the tester according to the rules when you
in the hospital.

XL-DM317G Multi-service Access
Test PDA
➢
Please keep far away from the precision instrument
➢
Do not use chemical solvent to clean the equipment.
➢
Do not throw away the waste battery. Put it into the
battery recycling bins.
➢
Please do not use or store the equipment as well as its
accessories under the environment of high temperature, low
temperature, high humidity or dust.
➢
Please put the equipment and its battery in a safety
place and avoid strong shake and impact.
➢
When use the equipment for the first time, please
charge the battery completely.
➢
Don't disassemble the equipment by yourself. If you
need, please go to the appointed professional organization
to mend it.
➢
Please put the equipment and its accessories in the
place out of children’s reach.
➢
Please take care of the UIM card and avoid static,
scratch, as well as bending.
➢
Please use the original accessories of the product.
➢
Please use the standard battery, charger and other
accessories. We will not be responsible for anything if you
use the accessories from the third party.
➢
Same as other mobile equipment, with built-in antenna
on the bottom of the product, there is some radiation and
interface of this product. If you want to operate the product
in light-hearted, as well as take of your personal safety, any
part of your body do not too close to the antenna.
5

➢
Please use the equipment within network coverage
range.
➢
The LCD display effect will change a little in the
temperature severely-changed and long-time conversation
environment.
3.
General Operation Standards and
Attentions
3.1. Operation Standards
➢
Test Interface
Please firstly connect the test cord to test interface and
then connect to the test line. Please don’t touch the metal
pars of clamps to avoid the high dangerous voltage.
➢
USB port
Please do not short the port with metal; otherwise the
internal circuit will be damaged.
➢
Cleaning
The shell of this instrument is mainly made of plastic,
when cleaning, use dry and soft cloth, and do not use
volatile chemicals, otherwise, it will cause discoloring and
deformation.
➢
Protecting the case and operating panel
Do not pour volatile agents on the case or operation
panel, and avoid prolonged contacting with rubber and PVC;
otherwise, it may result malfunctioning.
6

7
➢
When moving the instrument
Please make sure the power cord and connection
cables are removed before shift the instrument. And unplug
all the connecting cables from socket after using.
➢
When the instrument is unused for a long time
If the instrument is unused for a long time, the battery
characteristics may have deteriorated. And it will also take a
longer time to charger. If it take a very short time to charger
and the operating time is extremely short, please replace
the battery.
➢
Faults
If there are strange sound, smell, or smock coming
from the instrument, please turn off the instrument and
unplug of the power, and then contact with us immediately.
3.2. Attentions
➢
Please charger the battery full when using it for the first
time as well as each time.
➢
Please use touch pen and click the screen gently to
operate function keys, do not click it roughly, otherwise, the
LCD may be damaged.
➢
If there is any abnormal phenomenon during the
process of operating, please turn off and restart it.
➢
Please don’t put the instrument under the strong direct
sunlight or put it near the origin of heat. Or else, there will be
bad effect to internal circuit as well as the shell.
➢
Condensation may occur if the instrument is moved to
another place where the temperature is higher or the room

8
XL-DM317G Multi-service Access
Test PDA
temperature change rapidly. In such situation, let the
instrument adjust to the new environment for at least one
hour before using the instrument.
➢
Using the instrument near strong magnetic field
sources will have adverse affects on the internal circuit of
the instrument. That because the electromagnetic wave
from the mobile may effect the normal identification. If you
are using a portable phone to transmit measured data,
move the portable phone at least 1m away from the
instrument.

9
XL-DM317G Multi-service Access
Test PDA
4.
Structures and Functions

10
XL-DM317G Multi-service Access
Test PDA
NO
Name
Functions
1
Optical power
port
Connect with the fiber interface,
can be used as optical power
meter
2
VFL port
Connect with the fiber interface,
can be used as visual fault
locator.
3
Dust-proof cap
of optical port
Protect the optical port from dust
and water

11
XL-DM317G Multi-service Access
Test PDA
4
Scanning Head
Window of bar code scanning
engine, which is used to scan the
bar codes.
5
Dust-proof cap
of electric port
Protect the electric port from dust
and water
6
Ethernet port
The port to connect with Ethernet
7
Dust-proof cap
of USB
Protect the USB port and
Headphone from dust and water
8
USB Port
It is used to connect with PC or for
charging
9
Headphone
Jack
Connect the headphone
10
RJ11 port
Connect with telephone line to
test xDSL
11
Receiver
Receiver of the equipment
12
Indicator
It is used to indicate the
conditions of the equipment
13
Display screen
Display of the screen
14
Keyboard
Please refer to the following
instructions for more details.
15
Reset
Reset operation
16
MIC
MIC Hole
17
Touch pen
Touch pen of the equipment
18
Hand Belt
It is used for holding the
equipment.
19
Battery Cover
It is used to fix the battery

12
XL-DM317G Multi-service Access
Test PDA
20
Battery Cover
Screw
It is used for fix or loose the
battery cover
21
Fixed groove of
the hand belt
It is used to fix the hand belt.
22
Loudspeaker
Loudspeaker hole
23
Camera
Make a photo or video.
24
LED light
LED light also can be used as
flashlight.
25
RFID side key
RFID hotkey
26
Scan side key
Scan hot key
27
Volume key
Adjust volume of phone call or the
loud speaker.
Cable Tracing Receiver(It depends on the real item)
Number
Name
Function
1
Receiver probe
Antenna probe
2
Test button
Press it to test the signal
3
Loudspeaker
Audio signal generator
loudspeaker

13
XL-DM317G Multi-service Access
Test PDA
4
Switch and volume
adjustment key
Turn it down to increase the
volume and turn it up to
decrease the volume
Buttons:
Buttons
Name
Functions
Power button
Under power-on state, shortly
pressing the button can close
or light the screen; long
pressing the button can pop
up an operating menu of
"Device Options". Under
power-on state, long pressing
the button can close the
tester.
Return Button
Return back to the previous
page.
Main Screen
Button
Pressing this button to return
back to the main screen
window.
Menu Button
Under main screen interface
and application program
interface, pressing this button
can pop up the operating
menu.
Light Button
It is used to open the
flashlight.

14
XL-DM317G Multi-service Access
Test PDA
Camera
Button
Long pressing the button to
enter into camera interface,
and shortlypressing enter into
photo interface
Hang up
Button
When a call is coming, it can
hang up the call.
Dial/Answer
Button
Dial or answer the phone;
under standby condition,
pressing this button to enter
into call records.
Delete Button
When input text, it is used to
delete words before the
cursor.
Number
Button
It is used to input the
numbers.
Bar Code
Scan Button
Shortly pressing the button
can start to scan the bar code.
RFID Scan
Button
Shortly pressing the button
can start to scan the RFID
label.
Volume
Adjust Button
Can adjust the volume for
calling and louder speaker; up
is louder and down is lower.
Indicator lights:
The meaning of the 4 indicator lights from left to right is as

15
XL-DM317G Multi-service Access
Test PDA
following:
Indicator light 1: Mobile phone light, indicating the mobile
state, which have 3 glittering state.
1) Normal state: 0.5s on, 4.5s off
2) Incoming call state: 0.5s on, 0.5s off
3) Receive the message or missed call: 0.5s on, 1.5s
Indicator light 2: Unused
Indicator light 3: xDSL Link indicator; when it is in
activating mode, the indicator will glitter; when it is activated,
it will always light.
Indicator light 4: VFL and Cable Tracing indicator; when
the VFL or cable tracing signal is open, this indicator will
light.
Standby shortcut icon is as following:
: Click to enter into main menu interface.

16
XL-DM317G Multi-service Access
Test PDA
: Click to enter into dialing plate interface.
: Click to enter into message interface.
: Click to enter into browser interface.
: Click to enter into contacts
5.
Instructions of Fixed Icon Display Area
Display the current signal intensity of CDMA network
and EVDO: the more column bar is, the better the
signal intensity will be; means there is
no
signal; mean the 3G signal is strong.
Display the current signal intensity under roaming
condition: the more column bar is, the better the
signal intensity will be; ×means there is no signal.
Means that there is unread multimedia message
Means the signal intensity of theWLAN.
Means Bluetooth function has been opened.
Means uploading or downloading documents
Means that there is unread short message.
Means that there is unread short message.
Means it is in the flight mode.
Means the USB connection
Table of contents
Other XtendLan PDA manuals