Xvent MiracleAir 400-B Installation guide

Verze 001-GBR (19.05.2021) Stránka 1 z 2 D-502-0174
QUICK MANUAL FOR USE AND INSTALLATION Xvent s.r.o.
Poděbradská 289
53009 Pardubice-Trnová
Technical parameters
Regulation of the unit
all control elements located on the body of the unit that are designed for user control are energized by 10VDC (safe voltage)
The Quick Manual will guide you through a quick installation of the product, but in no case could it replace the full operating manual. A
complete operating manual is available on our website www.xvent.cz or can be downloaded using a QR code.
Use the smart device (mobile
phone, tablet, etc.) equipped
with this technology to read
the QR code.
Miracleair unit shall not be used:
Before starting all installation work, make sure that the mains power outlet you want to use for unit connection is equipped
with a protective contact (pin) and meets the requirements for unit power supply (production plate).
Use of the unit
M
iracle
A
ir
300
-
A; M
iracle
A
ir 4
00
-
B
- The Miracleair unit is designed for indoor covered and dry areas with an ambient temperatures from 5 °C to +40 °C and with a maximum
relative humidity of 70% - non-condensing, without too high a dust load in the surrounding air.
- The aerosol extraction unit MiracleAir 300-A is designed to extract the aerosol-fume that may occur in medical operations related to the
treatment of the patient, e.g. dental treatment, anaesthetic treatment.
- Air purifier–the MiracleAir 400-B unit–is designed to filter air in the internal environment, e.g.: medical facilities, waiting rooms, cosmetic
facilities, offices
- The unit is designed for the extraction and filtering of particles larger than 0,1 μm (filtering efficiency 99,95 per cent).
-
Neither the manufacturer nor the supplier is liable for damage caused by improper use of the units. The risk is borne solely
by the user.
- for suction of burning or glowing
substances
- for exhausting readily flammable or
explosive gases.
- to exhaust aggressive media
- to exhaust liquids of any kinds in an
environment with increased risk
- of explosion, flammable substances
and increased dust.
- Neither the manufacturer nor the
supplier is liable for damage caused by
improper use of the units.
Main control panel Signal diode
It is signalling the operation of the entire unit. If
the diode is lit, the unit is on. If the diode is not
on, the unit is switched off.
The indicator light of the
filter box clogging: it lights
up when the filter box is
clogged. Like this, it also
informs the user about the
necessity to change the
filter box.
The main control element (dial), allows
continuous adjustment of the power of the unit
in any position from the minimum to maximum
power according to user requirements. The
"OFF" position allows the entire regulator to be
switched off.

Verze 001-GBR (19.05.2021) Stránka 2 z 2 D-502-0174
QUICK MANUAL FOR USE AND INSTALLATION Xvent s.r.o.
Poděbradská 289
53009 Pardubice-Trnová
Commissioning
General Information – Safety
- Before starting all installation work, make sure that the mains power outlet you want to use to connect the unit is equipped with
a protective contact (pin).
- The electric supply plug must always remain accessible to allow safe disconnection of the unit from the mains in case of danger
- The electrical cable to be connected to the mains must not be broken
- When handling the unit, disconnect the device from the mains first (pull out the plug from mains socket).
- It is forbidden to interfere in any way with the internal connection of the unit
Switching on the unit
- Check that all fixation elements used during transport are removed
- Connect the MiracleAir to the mains using the mains cable (part of the unit).
- On the back side of the unit, switch on the main switch from the 0 position to the I position
- Turn the main control element (dial) approximately to the mid-position of the output scale (vertical)
- On the main control panel, the blue signal diode lights up, which indicates the operation of the unit
- The unit starts to run at speed to achieve the set output. The rise time of the unit fan may take about 5 sec.
- Unit ready for operation
Performance setting for the MiracleAir 300-A aerosol extractor
The setting for effective exhaust performance is graphically shown on the scale of the main control (dial) by the symbol of the exhaust
arm;
effective suction output is marked with dark colour.
MINIMUM RECOMMENDED PERFORMANCE SETTINGS
FOR EXTRACTION UNIT –EFFICIENT EXTRACTION
DISTANCE IS approx. 20 cm
MAXIMUM PERFORMANCE SET UP FOR THE EXTRACTION
UNIT –EFFICIENT EXTRACTION DISTANCE IS 30 cm
Performance setting for air cleaner
–
MiracleAir 400
-
B unit
- To adjust the filtration output, use the main control (dial) over the full scale.
- To select the correct output of the filter unit, always consider conditions of the area in which you will operate it.
- Depending on the surface size of the filtered area, select the appropriate unit performance settings.
MiracleAir 300
-
A; MiracleAir 400
-
B