Specification
Conforms to:
EN 300 220-1 / V2.1.1 (2006-04)
EN 301 489 -1, / V1.6.1 (2004-12)
EN 301 489-3, / V 1.4.1 (2002-08)
Environmental conditions:
-10°C to 40°C, relative humidity 70% non-
condensing
Radio: Microcontroller controlled
433.92MHz AM transmitter.
Battery: 1X 3V CR2032 Lithium Coin Cell,
2Years life at 50 activations per day.
Programming & testing
Program your door/window contact
beforeinstallation and test afterwards.
Please see your current system instruction
book.
Location
Locate the door/window contact
accessory taking into account the
following points:
•Mount as high as possible
•Do not aim a PIR at this door or window
Installation
Screw mounting
1Break through the knockouts (where the
plastic is thinner).
2Using the holes as a template, drill holes
in the surface and insert wall plugs if fixing
into plaster or brick. Screw the rear case
to the wall using the knockouts.
Self adhesive installation
Clean the surface with a suitable
degreaser.
1Remove the protective covering from
one side of the double sided adhesive pad
and firmly apply to the back of the device.
2Remove the other cover and firmly press
the item onto the desired location.
Do not use the adhesive pad method of
installation on a surface with peeling or
cracked paint, or on a rough surface.
3Mount the detector base on the frame
and align the magnet.
•The magnet should not be more than
8mm from the detector when the door is
closed.
•Ensurethe tamper switch spring is
positioned so that it makes contact with
the mounting surface through the tamper
switch aperture.
•When fitting to a window,fix the magnet
to the moving partand the detector to the
frame.
4Fix the detector on its base and secure
with screw.
Yale UK
School Street, Willenhall
West Midlands WV13 3PW
Tel +44 (0)1902 364647
Fax +44 (0)1902 364692
www.yale.co.uk E1 12/06