Yealink W90 User manual

W90 DECT IP Multi-Cell System
Quick Start Guide
http://support.yealink.com/
For W90DM/W90B rmware 130.85.0.15 or later
For W59R rmware 115.85.0.20 or later
For W53H rmware 88.85.0.20 or later
For W56H rmware 61.85.0.20 or later
For CP930W rmware 87.85.0.20 or later
For DD phone rmware 66.85.0.15 or later
(V85.16)

Table of Contents
English ..........................................1
Deutsch ........................................7
Español ......................................13
Français .....................................19

1
E
N
G
L
I
S
H
Package Contents
Installation
1. Connect the power and the network.
a. AC Power Option
b. PoE (Power over Ethernet) Option
IEEE 802.3acompliant
PoE Hub/Switch
Note:
•Iyou choose method a, use Yealink supplied power adapter (5V/1.2A).
A third-party power adapter may damage the device.
•Iyou choose method b, you do not need to connect the power adapter.
Make sure the hub/switch is PoE-compliant.
2. Mount W90DM/W90B on the wall.
InternetDC5V
InternetDC5V
Quick Start Guide
Optional
+
+
2
2
30 m m
25 m m
Max:8mm
(0.315”)
Min:6.5mm
(0.256”)
Max:4.5mm
(0.177”)
Max:3mm
(
0.118”
)
100mm
SN/MAC/RFPI
Label
100mm
SN/MAC/RFPI
Label
100mm
Internet
DC5V
SN/MAC/RFPI
Label
100mm
Internet
DC5V

2
E
N
G
L
I
S
H
Denin
g the Device Role
Accessing the Web User Interface
1. Do one othe ollowing:
•Find the current IP address othe device on the DHCP server in the list o
registered DHCP clients.
•Find the current IP address othe device through a PC scanning tool - Yea-
link Discovery Tool.
2. Open a web browser on your computer, enter the IP address into the
address bar (or example, "http://192.168.0.10" or "192.168.0.10"), and then
press the Enter.
3. Enter the user name (deault: admin) and password (deault: admin) in the
login page and click Login.
Base Mode
Option Role LAN LED ROLE LED DECT LED
1Base Green Green O
2DM Green Orange O
The ollowing shows the LED status ater the W90DM/W90B connects to the
power and network:
The W90DM is shipped as a DECT Manager (DM) and the W90B is shipped as
a base station.
Base Mode Options
90°
180°
3. Adjust the antenna angle.

3
E
N
G
L
I
S
H
Regulatory Notices
Operating Ambient Temperatures
•Operating temperature: +32 to 104°F (0 to 40°C)
•Relative humidity: 5% to 90%, noncondensing
•Storage temperature: -22 to +160°F (-30 to +70°C)
Warranty
Our product warranty is limited only to the unit itsel, when used normally in accordance
with the operating instructions and the system environment. We are not liable or damage
or loss resulting rom the use othis product, or or any claim rom a third party. We are
not liable or problems with Yealink device arising rom the use othis product; we are not
liable or nancial damages, lost prots, claims rom third parties, etc., arising rom the
use othis product.
DC symbol
is the DC voltage symbol.
Restriction oHazardous Substances Directive (RoHS)
This device complies with the requirements othe EU RoHS Directive. Statements o
Saety Instructions
Save these instructions. Read these saety instructions beore use!
To reduce risk o re, severe personal injury and damage to property, read the ollowing
saety inormation careully beore using the product.
Environmental Requirements
•Place the product on a stable, level and non-slip surace.
•Do not place the product close to heat sources, in direct sunlight or next to any
house hold appliance with strong magnetic eld or electromagnetic eld, such as a
microwave oven or a rerigerator.
•Do not allow the product to come into contact with water, dust and chemicals.
•Protect the product rom aggressive liquids and vapors.
•Do not place the product on or near any infammable or re-vulnerable object, such
as rubber-made materials.
•Do not install the product in rooms with high humidity, or example, in bathrooms,
laundry rooms and wet basements.
Saety Notes During Operation
•Use only spare parts and accessories supplied or authorized by Yealink. The
operation onon-authorized parts cannot be guaranteed.
•Do not place heavy objects on top othe handset or the base station in case odam
age and deormation caused by the heavy load.
•Do not open the handset or the base station by yoursel or repair purpose, which
could expose you to high votages. Have all repairs carried out by authorized service
personel.
Tel: +86-592-5702000
Fax: +86-592-5702455
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C

4
E
N
G
L
I
S
H
•Do not let a child operate the product without guidance.
•Keep the small accessories contained in your product out oreach osmall children
in case oaccidental swallowing.
•Beore plugging or unplugging any cable, make sure that your hands are completely
dry.
•Do not hold the handset up to your ear when speakerphone is on or when the ringer
is ringing as the volume can be very loud, which may be harmul to your hearing.
•During a thunderstorm, stop using the product and disconnect it rom the power
supply to avoid lightning strike.
•Ithe product is let unused or a rather long time, disconnect the base station rom
the power supply and unplug the power adapter.
•When there is smoke emitted rom the product, or some abnormal noise or smell,
disconnect the product rom the power supply, and unplug the power adapter
immediately.
•Remove the electrical cord rom an outlet by pulling gently on the power adapter,
not by pulling the cord.
Notices of Cleaning
•Beore cleaning the base station, stop using it and disconnect it rom the power
supply.
•Remove the battery beore cleaning the handset to reduce risk oelectric shock.
•Only clean your product with a piece oslightly moist and anti-static cloth.
•Keep the power plug clean and dry. Using a dirty or wet power plug may lead to
electric shock or other perils.
Tel: +86-592-5702000
Fax: +86-592-5702455
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C

5
E
N
G
L
I
S
H
ENVIRONMENTAL RECYCLING
Never dispose of the device with domestic waste
Ask your Town Council about how to dispose oit in an environmentally
riendly way. The cardboard box, plastic packaging and player compo-
nents may be recycled in accordance with prevailing recycling regula-
tions in your country.
Always adhere to prevailing regulations
Those who ail to do so may be ned or prosecuted in accordance
with the law. The crossed out garbage can that appears on the device
means that when it has reached the end oits useul lie, it should be
taken to a special waste disposal center and treated separately to
general urban waste.
Troubleshooting
The unit cannot supply power to Yealink device.
There is a bad connection with the plug.
1. Clean the plug with a dry cloth.
2. Connect it to another wall outlet.
The usage environment is out ooperating temperature range.
1. Use in the operating temperature range.
The cable between the unit and the Yealink device is connected incorrectly.
1. Connect the cable correctly.
You cannot connect the cable properly.
1. You may have connected a wrong Yealink device.
2. Use the correct power supply.
Some dust, etc., may be in the port.
1. Clean the port.
Contact your dealer or authorized service acility or any urther questions.
Contact Inormation
YEALINK NETWORK TECHNOLOGY CO.,LTD.
309, 3rd Floor, No.16, Yun Ding North Road, Huli District, Xiamen City, Fujian, P.R.C
YEALINK (EUROPE) NETWORK TECHNOLOGY B.V.
Strawinskylaan 3127, Atrium Building, 8th foor, 1077ZX Amsterdam, The Netherlands
YEALINK (USA) NETWORK TECHNOLOGY CO., LTD.
999 Peachtree Street Suite 2300, Fulton, Atlanta, GA, 30309, USA
Made in China
Tel: +86-592-5702000
Fax: +86-592-5702455
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C

6
E
N
G
L
I
S
HDeclaration oConormity
We,
YEALINK(XIAMEN) NETWORK TECHNOLOGY CO.,LTD,
Address: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C
CE DATE: 20th /September/2020
declare that the product
Type: DECT IP Multi-Cell Base Station, DECT IP Multi-Cell Dect Manager
Model: W90B,W90DM
meets the essential requirements and other relevant provisions according to the ollowing
EC directive
Directive: 2014/30/EU, 2014/35/EU, RED 2014/53/EU;
The presumption oconormity with the essential requirement is ensure according to:
Article 3.1 a : (protection othe health &the saety othe user)
Saety: EN 62368-1:2014/AC2015
SAR: ETSI EN 50385:2017
Article 3.1 b : (protection requirement with respect to electromagnetic compatibility)
EMC: EN55032:2012+AC:2013 and EN55032:2015+AC2016 EN55035:2017
EN301489-6 V2.2.2,EN301489-1 V2.2.2
Article 3.2 (eective use othe radio spectrum)
Radio: ETSI EN 301406 V2.2.2
Directive 2011/65/EU and (EU)2015/863 othe European Parliament and othe Council o
8 June 2011 and 4 June 2015 on the restriction othe use ocertain hazardous substanc-
es in electrical and electronic equipment(RoHS 2.0)
Directive 2012/19/EU othe European Parliament and othe Council o4.July.2012 on
Waste electrical and electronic equipment(WEEE)
Regulation (EC) No.1907/2006 othe European Parliament and othe Council o18.
December.2006 on Registration, Evaluation, Authorization, and Restriction oChemicals
(REACH)
YEALINK (EUROPE) NETWORK TECHNOLO-
GY B.V
Address: Strawinskylaan 3127, Atrium Building,
8th foor, 1077ZX Amsterdam, the Netherlands
Telephone: +31(0)646111373
Email: EUROPE@Yealink.com
Tel: +86-592-5702000
Fax: +86-592-5702455
YEALINK (XIAMEN) NETWORK TECHNOLOGY CO.,LTD
WWW.YEALINK.COM
Addr: 309, 3rd Floor, No.16, Yun Ding North Road,
Huli District, Xiamen City, Fujian, P.R.C
N
AME: Stone Lu
D
ATE:
20/Sep/2020
T
ITLE: Vice President
Other manuals for W90
2
Table of contents