5. Characteristics and Reliability Test
Test Items Test Condition and Procedure Requirements
C1 S.W.R. Set DUT on Network Analyzer; make individual
calibration to test
Directive DUT specification
C2 Antenna
Gain
Set DUT on Antenna Chamber; make individual
calibration to test
Directive DUT specification
M1 Vibration MIL-STD-202G, 201A
Amplitude: 0.03 inch (0.76mm); Freq: 10 to 55 Hz
3 directions; 2 hours for each direction
1. No Visual Damage
2. Frequency Tol.<= 5%
M2 Random
Drop
Height: 1.5 Meter;
3 directions; 1 time for each direction
1. No parts separated
2. Frequency Tol.<= 5%
M3 Solderability MIL-STD-202G, 210F, cond. A
Solder iron: 350±10°C; Duration: 5 seconds
1. Mounted on PCB
2. No Visual Damage
M4 Terminal-
Pull Test
MIL-STD-202G, 211A, cond. A
Holding with individual specification; force applied
to axis of terminal
1. Directive DUT specification
2. Frequency Tol.<= 5%
M5 Terminal-
Torque Test
MIL-STD-202G, 211A, cond. E
Holding with individual specification; applied
clockwise and counterclockwise to the axis of
terminal
1. Directive DUT specification
2. Frequency Tol.<= 5%
M6 Dimension Inspection of dimension, color, material, package,
surface process
Directive DUT specification
E1 Salt Spray MIL-STD-202G, 101E, cond. B
Temp: 35°C; RH: >= 95%; NaCl solution: >= 5%;
Time: 48 hours
After 2 Hours Recovery
1. No Visual Damage
2. Frequency Tol.<= 5%
E2 Humidity MIL-STD-202G, 103B, cond. B
Temp: 40°C; RH: >= 95%; Time: 48 hours
After 2 Hours Recovery
1. No Visual Damage
2. Frequency Tol.<= 5%
E3 Thermal
Shock
1 Cycle: - 40°C (30 minutes) to + 80°C (30 minutes)
Cycles: 24
After 2 Hours Recovery
1. No Visual Damage
2. Frequency Tol.<= 5%
E4 Life (High
Temp.)
MIL-STD-202G, 108A, cond. A
Temp: 85°C; Time: 96 hours
After 2 Hours Recovery
1. No Visual Damage
2. Frequency Tol.<= 5%
R1 RoHS With Reference to IEC 62321:2008 with flow chart Directive RoHS 2002/95/EC
R2 PFOS With Reference to USA EPA 3540C:1996 by LC/MS Directive RoHS 2006/122/EC
R3 PFOA With Reference to USA EPA 3540C:1996 by LC/MS Directive RoHS 2006/122/EC