Yokis MD3300MRP User manual

DS1054-074B
EN
MD3300MRP 5454801 Radio: Load manager POWER
The complete instruction booklets in French, Spanish, German,
Nederlands, Danish / Norwegian and the device conguration
booklets via the Yokis PRO App can be downloaded by scanning the
following QR-Code.
1. GENERAL DESCRIPTION
The MD3300MRP device is designed to control electrical loads so as to
prevent, in case of simultaneous switching on of several devices, an overload
that may cause the maximum electrical energy consumption allowed by the
supplier to be exceeded and consequently the mains power supply to be
disconnected. For proper operation of the device it is necessary to:
• assign one or more MTR2000ERP(X) or MTR2000MRP(X) radio receiver
relays to the MD3300MRP device (up to 7 relays directly connected or
more than 7 using the RADIO BUS);
•
make the assignment between the receiver modules and the device
channels (max 8 channels, each with a different priority: channel 1 = priority
1 = highest priority), so as to indicate to the MD3300MRP load manager
which receiver modules are to be piloted according to the priorities.
It is possible to assign more than one receiver module to each
channel in order to disconnect several loads at the same time. This
also allows simultaneous control of phase and neutral on the same
load, where this is deemed necessary.
If the absorbed power exceeds the set threshold continuously for the
pre-alarm time (Ton), the MD3300MRP load manager provides the loads
disconnection (receivers), starting from the lowest priority, as long as the
value of the absorbed power does not result lower than the activation
threshold. Once the alarm reset time (Toff) has elapsed, the device provides
the loads connection (receivers) in reverse order. The load manager and
the actuators communicate exclusively via radio.
RADIO RANGE
POWER Range:
• Inside 100 m² apartments with perpendicular crossing of main wall or
ceiling.
• 250m in open range.
Range may be reduced by presence of metallic elements, crossing of
walls or partitions.
2. INSTALLATION
Precautions for the installer
• The device must only be installed by qualied personnel in a closed
and adequately protected electrical panel, in accordance with national
installation standards.
• Before performing the installation operations, check that the devices
and conductors are not live.
• In order to comply with the safety regulations, the device must be connected
to an electrical line protected upstream by a magnetothermic switch (curve
C) with a current suitable for the load.
• Do not power on or connect the device if any part of it is damaged.
• After installation, inaccessibility to the connection terminals without
appropriate tools must be guaranted.
• The device can be used in environments with category of measurement
III and pollution degree 2.
For proper operation, the MD3300MRP load manager must measure the
same current as the general energy meter. For this reason the ideal position
for the device connection is immediately downstream of the general switch.
3. WIRING
RADIO: LOAD MANAGER
Wires with cross-section area of 0.5 mm2or larger must comply with
IEC 60332-1-2; wires with cross section area smaller than 0.5 mm2must
comply with IEC 60332-2-2.
It is necessary to wire and power the MTR2000ERP(X) or MTR2000MRP(X)
receiver before the assignment with the MD3300MRP load manager.
Always make sure that the MTR module is congured with the default
values.
The MTR used for load control must manage electrical sockets. In this case, in
rest conditions, the MD3300MRP load control device periodically carries out
an automatic check of all the MTR modules, in order to restart them in a time
that can vary between 5 minutes and 40 minutes “.
4. FIRMWARE RELEASE
Press and hold the keys and for more than 3 seconds to display the
rmware release of the device.
5. RESET TO FACTORY SETTINGS
If you want to delete all the settings made and restore the factory values, press
the keys and simultaneously for more than 3 seconds. The display will
show “RESET”. Factory values:
- Setpoint: 3.3 kW
- Ton: 60 seconds
- Toff: 120 seconds
CAUTION!: Resetting to the factory settings does not delete the radio
assignments made on the MD3300MRP device. To delete radio assignments,
see in detail chapter “REMOVING ALL RADIO ASSIGNMENTS”.
6. TECHNICAL SPECIFICATIONS
Power supply: 230V~ (+10% -15%) - 50 Hz
Maximum own consumption: 4 VA
Direct current connection until 32A
Settable power threshold range: 0.8 ÷ 7 kW
Pre-alarm time range Ton: 10 ÷ 9999 seconds
Disconnection time range Toff: 10 ÷ 9999 seconds
Blocks for cables with maximum section of 6 mm2
Radio frequency band: 2400 - 2480 MHz
Maximum radio power transmitted: 10mW
Operating temperature: -10°C ÷ +45°C
Operating humidity: 10% ÷ 90% non condensing
Storage temperature: -10°C ÷ +65°C
Container: 2 DIN modules
Overvoltage category: II
Operating altitude: below 2000 m (from 0 to 6560 ft)
Protection degree: IP20 / IP40 (on the front panel)
Indoor usage only, non-wet location
Insulation: reinforced between accessible parts (front panel) and all other terminals
Dimensions (H x L x D): 87,5 x 35,6 x 65 mm
7. KEY TO SYMBOLS
Symbol Description
~
Alternating input voltage
See the installation manual of the device
8. SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, FDI Matelec SA., declares that the radio equipment type:
MD3300MRP load manager (code 5454801) is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity is available at the
following internet address: www.Yokis.com
RADIO ASSIGNMENT BETWEEN AN MTR RECEIVER MODULE AND THE
MD3300MRP LOAD MANAGER
For correct operation, it is essential to congure a radio assignment between
the MD3300MRP load manager and the MTR2000ERP(X) or MTR2000MRP(X)
radio receiver relays. The MD3300MRP device is able to manage up to 7
receiver modules directly connected. If you wish to manage more than 7
modules, it is necessary to create a radio bus to allow communication between
the MD3300MRP device and the subsequent modules.
Only one MD3300MRP device can be congured on each system.
▶On the MD3300MRP device, access the RADIO conguration menu by
simultaneously pressing keys and (for approx. 3 seconds) until the
display shows “bind.r1”.
You can cancel the assignment operation by pressing key.
▶Press key on the device to perform radio assignment.
▶While “InProG” is ashing (for 30 seconds), press briey with a sharp,
properly insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP device will briey display the message “PASS” if the
assignment has been successful. The receiver module is now correctly
assigned to the MD3300MRP device.
▶If the device displays the message “Err. 03” the assignment has not been
successful. Repeat the operation and make sure to press into the “Connect”
hole on the receiver module within the 30 seconds in which the MD3300MRP
load manager displays the message “InProG”.
In some cases, if the receiver is out of radio range, it is possible that the
load manager is unable to communicate with the receiver and displays
the message “Err. 03”. In this case, refer to paragraph “Extending the
range”.
▶It is necessary to repeat the entire assignment procedure for each receiver
module you wish to assign directly to the MD3300MRP device.
REMOVING ONE SINGLE RADIO ASSIGNMENT
It is possible to remove an assignment between an MTR receiver module and
the MD3300MRP load manager.
▶On the MD3300MRP device, access the RADIO conguration menu by
simultaneously pressing keys and (for approx. 3 seconds) until the
display shows “bind.r1”.
▶Press the arrow key or until “dEL .r6” is displayed.
You can cancel the assignment operation by pressing key.
▶Press to remove the assignment.
▶While “InProG” is ashing (for 30 seconds), press briey with a sharp,
properly insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP load manager will briey display the message “PASS” if
the receiver module assignment removal has been successful.
▶If the device displays the message “Err. 03” the assignment removal has
not been successful. Repeat the operation and make sure to press into the
“Connect” hole on the receiver module within the 30 seconds in which the
MD3300MRP load manager displays the message “InProG”.
>3s
Radio assignment
Removing a
radio assignment
Removing all
radio assignments
Procedure completed
Procedure failed
>4 sec.
>4 sec.
Scan
DEVICE SCAN FOR YOKIS PRO APP
The scanning operation allows the MD3300MRP device to be detected by
the Yokis Pro App in order to subsequently carry out the assignment to the
channels and the parameter conguration (Paragraphs 10 and 11) directly
from the App.
▶On the MD3300MRP device, access the RADIO conguration menu by
simultaneously pressing keys and (for approx. 3 seconds) until the
display shows “bind.r1”.
▶Press the arrow key or until “SCAn” is displayed.
You can cancel the scan by pressing key.
▶Press the key to start the detection.
▶While “InProG” is ashing (for 30 seconds), start the device search on the
Yokis Pro App and select it.
▶The MD3300MRP load manager briey displays the message “PASS” if
the device has been detected and selected by the Yokis Pro App.
▶If the device displays the message “Err. 03” the detection has not been
successful. Repeat the operation and make sure to start the device search
on the Yokis Pro App within the 30 seconds in which the MD3300MRP
load manager displays the message “InProG”.
For more details on channel assignment and conguration of the
MD3300MRP device through the Yokis Pro App, scan the QR Code
at the beginning of the booklet to download the booklet.
REMOVING ALL RADIO ASSIGNMENTS
It is possible to remove all assignments between the various receiver
modules and the MD3300MRP load manager.
▶On the MD3300MRP load manager, access the RADIO communication
menu by simultaneously pressing keys and (for approx. 3 seconds)
until the display shows “bind.r1”.
▶Press the arrow key until “CLEAr” is displayed.
▶Press the key to delete all assignments.
▶The MD3300MRP device will briey display the message “PASS”. All
assignments with receiver modules have been removed.
EXTENDING THE RANGE
All YOKIS radio receivers also work as signal repeaters. The addition of one
or more modules allows extending the radio range by creating a Radio Bus
between the various modules on the system.
1) Creating the Radio Bus
▶Press once the Connect button of A module (the LED of A module starts
ashing), then press once the Connect button of B module (connection
between A and B is created and the 2 modules stop ashing).
▶The two buttons must be pressured within a maximum of 30 seconds.
▶Perform the same operation between B and C modules and so on with
the other modules.
Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012
on waste electrical and electronic equipment (WEEE)
The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that
this product must not be disposed of with your other household waste. Instead, it is your
responsibility to dispose of your waste equipment by handing it over to a designated collection
point for the recycling of waste electrical and electronic equipment. The separate collection and recycling
of your waste equipment at the time of disposal will help to conserve natural resources and ensure that
it is recycled in a manner that protects human health and the environment. For more information about
where you can drop off your waste equipment for recycling, please contact your local city ofce, your
household waste disposal service or the shop where you purchased the product.
9. RADIO CONFIGURATION MENU
Wiring via MTR2000ERP(X)
230V
50Hz
L
N
C1
N
C2
BP
L
5454801 5454462
Two-pole
thermo-magnetic
circuit breaker
Wiring via MTR2000MRP(X)
230V
50Hz
L
N
5454801
5454464
Two-pole
thermo-magnetic
circuit breaker
>3 seconds
DS1054-074B
EN
MD3300MRP 5454801 Radio: Load manager POWER
The complete instruction booklets in French, Spanish, German,
Nederlands, Danish / Norwegian and the device conguration
booklets via the Yokis PRO App can be downloaded by scanning the
following QR-Code.
1. GENERAL DESCRIPTION
The MD3300MRP device is designed to control electrical loads so as to
prevent, in case of simultaneous switching on of several devices, an overload
that may cause the maximum electrical energy consumption allowed by the
supplier to be exceeded and consequently the mains power supply to be
disconnected. For proper operation of the device it is necessary to:
• assign one or more MTR2000ERP(X) or MTR2000MRP(X) radio receiver
relays to the MD3300MRP device (up to 7 relays directly connected or
more than 7 using the RADIO BUS);
•
make the assignment between the receiver modules and the device
channels (max 8 channels, each with a different priority: channel 1 = priority
1 = highest priority), so as to indicate to the MD3300MRP load manager
which receiver modules are to be piloted according to the priorities.
It is possible to assign more than one receiver module to each
channel in order to disconnect several loads at the same time. This
also allows simultaneous control of phase and neutral on the same
load, where this is deemed necessary.
If the absorbed power exceeds the set threshold continuously for the
pre-alarm time (Ton), the MD3300MRP load manager provides the loads
disconnection (receivers), starting from the lowest priority, as long as the
value of the absorbed power does not result lower than the activation
threshold. Once the alarm reset time (Toff) has elapsed, the device provides
the loads connection (receivers) in reverse order. The load manager and
the actuators communicate exclusively via radio.
RADIO RANGE
POWER Range:
• Inside 100 m² apartments with perpendicular crossing of main wall or
ceiling.
• 250m in open range.
Range may be reduced by presence of metallic elements, crossing of
walls or partitions.
2. INSTALLATION
Precautions for the installer
• The device must only be installed by qualied personnel in a closed
and adequately protected electrical panel, in accordance with national
installation standards.
• Before performing the installation operations, check that the devices
and conductors are not live.
• In order to comply with the safety regulations, the device must be connected
to an electrical line protected upstream by a magnetothermic switch (curve
C) with a current suitable for the load.
• Do not power on or connect the device if any part of it is damaged.
• After installation, inaccessibility to the connection terminals without
appropriate tools must be guaranted.
• The device can be used in environments with category of measurement
III and pollution degree 2.
For proper operation, the MD3300MRP load manager must measure the
same current as the general energy meter. For this reason the ideal position
for the device connection is immediately downstream of the general switch.
3. WIRING
RADIO: LOAD MANAGER
Wires with cross-section area of 0.5 mm2or larger must comply with
IEC 60332-1-2; wires with cross section area smaller than 0.5 mm2must
comply with IEC 60332-2-2.
It is necessary to wire and power the MTR2000ERP(X) or MTR2000MRP(X)
receiver before the assignment with the MD3300MRP load manager.
Always make sure that the MTR module is congured with the default
values.
The MTR used for load control must manage electrical sockets. In this case, in
rest conditions, the MD3300MRP load control device periodically carries out
an automatic check of all the MTR modules, in order to restart them in a time
that can vary between 5 minutes and 40 minutes “.
4. FIRMWARE RELEASE
Press and hold the keys and for more than 3 seconds to display the
rmware release of the device.
5. RESET TO FACTORY SETTINGS
If you want to delete all the settings made and restore the factory values, press
the keys and simultaneously for more than 3 seconds. The display will
show “RESET”. Factory values:
- Setpoint: 3.3 kW
- Ton: 60 seconds
- Toff: 120 seconds
CAUTION!: Resetting to the factory settings does not delete the radio
assignments made on the MD3300MRP device. To delete radio assignments,
see in detail chapter “REMOVING ALL RADIO ASSIGNMENTS”.
6. TECHNICAL SPECIFICATIONS
Power supply: 230V~ (+10% -15%) - 50 Hz
Maximum own consumption: 4 VA
Direct current connection until 32A
Settable power threshold range: 0.8 ÷ 7 kW
Pre-alarm time range Ton: 10 ÷ 9999 seconds
Disconnection time range Toff: 10 ÷ 9999 seconds
Blocks for cables with maximum section of 6 mm2
Radio frequency band: 2400 - 2480 MHz
Maximum radio power transmitted: 10mW
Operating temperature: -10°C ÷ +45°C
Operating humidity: 10% ÷ 90% non condensing
Storage temperature: -10°C ÷ +65°C
Container: 2 DIN modules
Overvoltage category: II
Operating altitude: below 2000 m (from 0 to 6560 ft)
Protection degree: IP20 / IP40 (on the front panel)
Indoor usage only, non-wet location
Insulation: reinforced between accessible parts (front panel) and all other terminals
Dimensions (H x L x D): 87,5 x 35,6 x 65 mm
7. KEY TO SYMBOLS
Symbol Description
~
Alternating input voltage
See the installation manual of the device
8. SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, FDI Matelec SA., declares that the radio equipment type:
MD3300MRP load manager (code 5454801) is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity is available at the
following internet address: www.Yokis.com
RADIO ASSIGNMENT BETWEEN AN MTR RECEIVER MODULE AND THE
MD3300MRP LOAD MANAGER
For correct operation, it is essential to congure a radio assignment between
the MD3300MRP load manager and the MTR2000ERP(X) or MTR2000MRP(X)
radio receiver relays. The MD3300MRP device is able to manage up to 7
receiver modules directly connected. If you wish to manage more than 7
modules, it is necessary to create a radio bus to allow communication between
the MD3300MRP device and the subsequent modules.
Only one MD3300MRP device can be congured on each system.
▶On the MD3300MRP device, access the RADIO conguration menu by
simultaneously pressing keys and (for approx. 3 seconds) until the
display shows “bind.r1”.
You can cancel the assignment operation by pressing key.
▶Press key on the device to perform radio assignment.
▶While “InProG” is ashing (for 30 seconds), press briey with a sharp,
properly insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP device will briey display the message “PASS” if the
assignment has been successful. The receiver module is now correctly
assigned to the MD3300MRP device.
▶If the device displays the message “Err. 03” the assignment has not been
successful. Repeat the operation and make sure to press into the “Connect”
hole on the receiver module within the 30 seconds in which the MD3300MRP
load manager displays the message “InProG”.
In some cases, if the receiver is out of radio range, it is possible that the
load manager is unable to communicate with the receiver and displays
the message “Err. 03”. In this case, refer to paragraph “Extending the
range”.
▶It is necessary to repeat the entire assignment procedure for each receiver
module you wish to assign directly to the MD3300MRP device.
REMOVING ONE SINGLE RADIO ASSIGNMENT
It is possible to remove an assignment between an MTR receiver module and
the MD3300MRP load manager.
▶On the MD3300MRP device, access the RADIO conguration menu by
simultaneously pressing keys and (for approx. 3 seconds) until the
display shows “bind.r1”.
▶Press the arrow key or until “dEL .r6” is displayed.
You can cancel the assignment operation by pressing key.
▶Press to remove the assignment.
▶While “InProG” is ashing (for 30 seconds), press briey with a sharp,
properly insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP load manager will briey display the message “PASS” if
the receiver module assignment removal has been successful.
▶If the device displays the message “Err. 03” the assignment removal has
not been successful. Repeat the operation and make sure to press into the
“Connect” hole on the receiver module within the 30 seconds in which the
MD3300MRP load manager displays the message “InProG”.
>3s
Radio assignment
Removing a
radio assignment
Removing all
radio assignments
Procedure completed
Procedure failed
>4 sec.
>4 sec.
Scan
DEVICE SCAN FOR YOKIS PRO APP
The scanning operation allows the MD3300MRP device to be detected by
the Yokis Pro App in order to subsequently carry out the assignment to the
channels and the parameter conguration (Paragraphs 10 and 11) directly
from the App.
▶On the MD3300MRP device, access the RADIO conguration menu by
simultaneously pressing keys and (for approx. 3 seconds) until the
display shows “bind.r1”.
▶Press the arrow key or until “SCAn” is displayed.
You can cancel the scan by pressing key.
▶Press the key to start the detection.
▶While “InProG” is ashing (for 30 seconds), start the device search on the
Yokis Pro App and select it.
▶The MD3300MRP load manager briey displays the message “PASS” if
the device has been detected and selected by the Yokis Pro App.
▶If the device displays the message “Err. 03” the detection has not been
successful. Repeat the operation and make sure to start the device search
on the Yokis Pro App within the 30 seconds in which the MD3300MRP
load manager displays the message “InProG”.
For more details on channel assignment and conguration of the
MD3300MRP device through the Yokis Pro App, scan the QR Code
at the beginning of the booklet to download the booklet.
REMOVING ALL RADIO ASSIGNMENTS
It is possible to remove all assignments between the various receiver
modules and the MD3300MRP load manager.
▶On the MD3300MRP load manager, access the RADIO communication
menu by simultaneously pressing keys and (for approx. 3 seconds)
until the display shows “bind.r1”.
▶Press the arrow key until “CLEAr” is displayed.
▶Press the key to delete all assignments.
▶The MD3300MRP device will briey display the message “PASS”. All
assignments with receiver modules have been removed.
EXTENDING THE RANGE
All YOKIS radio receivers also work as signal repeaters. The addition of one
or more modules allows extending the radio range by creating a Radio Bus
between the various modules on the system.
1) Creating the Radio Bus
▶Press once the Connect button of A module (the LED of A module starts
ashing), then press once the Connect button of B module (connection
between A and B is created and the 2 modules stop ashing).
▶The two buttons must be pressured within a maximum of 30 seconds.
▶Perform the same operation between B and C modules and so on with
the other modules.
Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012
on waste electrical and electronic equipment (WEEE)
The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that
this product must not be disposed of with your other household waste. Instead, it is your
responsibility to dispose of your waste equipment by handing it over to a designated collection
point for the recycling of waste electrical and electronic equipment. The separate collection and recycling
of your waste equipment at the time of disposal will help to conserve natural resources and ensure that
it is recycled in a manner that protects human health and the environment. For more information about
where you can drop off your waste equipment for recycling, please contact your local city ofce, your
household waste disposal service or the shop where you purchased the product.
9. RADIO CONFIGURATION MENU
Wiring via MTR2000ERP(X)
230V
50Hz
L
N
C1
N
C2
BP
L
5454801 5454462
Two-pole
thermo-magnetic
circuit breaker
Wiring via MTR2000MRP(X)
230V
50Hz
L
N
5454801
5454464
Two-pole
thermo-magnetic
circuit breaker
>3 seconds
DS1054-074B
ASSIGNING AN MTR RECEIVER MODULE TO A CHANNEL
▶On the MD3300MRP load manager, access the PARAMETER conguration
menu by pressing the key . The icons /and “kW” will start
ashing.
▶Press the arrow key or until the icons and ash on the
display. Press the key to enter the CHANNEL conguration menu.
▶The device display shows “Add CH”. Press the key to assign the
receiver module to the channel.
▶The display shows “CH N. .8” where the parameter “N” indicates the
channel number (from 1 to 8) where the assignment to the receiver module
is made, the parameter 8indicates the maximum number of channels.
It is recommended to perform the assignment starting with the
channels with the highest priority. Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C - For technical information, go to www.yokis.com or call:
Customer Service: +39 011.23.39.810 - export dept. Phone: +39 011.24.00.250/256
▶Press the arrow keys or to select the channel “N” on which you want
to perform the assignment. Press the key to conrm.
▶While “InProG” is ashing for 30 seconds, press briey with a sharp, properly
insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP device will briey display the message “PASS” if the
assignment of the channel to the receiver module has been successful.
▶If the device displays the message “Err. 03” the assignment has not been
successful. Repeat the operation and make sure to press into the “Connect”
hole on the receiver module within the 30 seconds in which the MD3300MRP
load manager displays the message “InProG”.
▶It is necessary to repeat the procedure for each receiver module you wish to
assign to a channel of the MD3300MRP device.
It is possible to assign more than one receiver module to each channel.
In this case, if the absorption threshold is exceeded, there will be two
or more loads disconnecting at the same time.
REMOVING AN ASSIGNMENT BETWEEN AN MTR RECEIVER MODULE
AND A CHANNEL
It is possible to remove an assignment between an MTR receiver module and
a channel of the MD3300MRP device.
▶On the MD3300MRP device, access the PARAMETER conguration menu by
pressing the key . The icons /and “kW” will start ashing.
▶Press the arrow key or until the icons and ash. Press the key
to enter the CHANNEL conguration menu.
▶The device display shows “Add CH”. Press the arrow keys or until
“dEL CH” is displayed, press the key to remove an assignment.
▶“InProG” is displayed.
▶While “InProG” is ashing for 30 seconds, press briey with a sharp, properly
insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP device will briey display the message “PASS” if the
assignment removal between the channel and the receiver module has been
successful.
▶If the device displays the message “Err. 03” the assignment removal has
not been successful. Repeat the operation and make sure to press into the
“Connect” hole on the receiver module within the 30 seconds in which the
MD3300MRP load manager displays the message “InProG”.
▶It is necessary to repeat the entire procedure for each assignment you wish
to remove.
TEST FUNCTION
The test function is used to check that the assignment between the receiver
module and the MD3300MRP load manager (i.e. the relevant channel) is
working correctly. The test involves a switching on and off sequence (one
every 10 seconds) of the receiver module.
▶On the MD3300MRP load manager, access the PARAMETER conguration
menu by pressing the key . The icons / and “kW” will start
ashing.
▶Press the arrow key or until the icons and ash on the display.
Press the key to enter the CHANNEL conguration menu.
▶The device display shows “Add CH”. Press the arrow keys or until
“test” is displayed, press the key to test a channel.
▶The display shows “CH N. .8” where the parameter “N” indicates the channel
number (from 1 to 8) where the test is performed, the parameter 8indicates
the maximum number of channels.
▶Press the arrow keys or to select the channel “N” on which you want
to perform the test. Press to conrm.
▶Every time the command is transmitted, the icon ashes for a few
seconds while the alarm LED, located between the keys or , shows
the transmission status:
LED on = actuation ON
LED off = actuation OFF
It is possible to interrupt the test by pressing .
▶The MD3300MRP device briey displays the message “PASS” at the end of
the test.
11. OPERATING PARAMETER CONFIGURATION MENU
The following operating parameters can be congured through the parameter
conguration menu:
- Setpoint (kW)
- Ton (seconds)
- Toff (seconds)
When a parameter has been congured, the device automatically
switches to the next parameter conguration. To exit the parameter
conguration menu, simply press the key.
When conguring parameters, long presses of the arrow key or
allows changing the values more quickly.
SETPOINT (kW)
Represents the activation threshold that is to say the maximum value of
accepted consumption. Over this value the MD3300MRP device provides
for the disconnection of the lowest priority load that is connected in that
moment.
▶On the MD3300MRP device, access the PARAMETER conguration menu by
pressing the key. The icons / and “kW” will start ashing. Press
the key for Setpoint conguration.
▶On the display, the icons / will be steady on and the Setpoint
parameter value will start ashing.
▶Press the arrow keys or to set the Setpoint parameter. The
parameter value can be set in an interval from 0.8 kW to 7kW. Press the
key to conrm and go to the next parameter conguration.
Ton (seconds)
Represents the pre-alarm time, that is to say how long the power must be
higher than the setpoint before the load is actually disconnected.
▶On the display, the icons / will be steady on and the prealarm time
value (Ton) will start ashing.
▶Press the arrow keys or to set the prealarm time (Ton). The
parameter value can be set in an interval from 10 seconds to 9999
seconds. Press the key to conrm and go to the next parameter
conguration.
Toff (seconds)
Represents the recovery time, that is to say after how long the most priority
load, disconnected in that moment, is reconnected.
The load is connected only if the absorbed power is lower than the
set power threshold.
▶On the display, the icons / / will be steady on and the alarm
reset time value (Toff) will start ashing.
▶Press the arrow keys or to set the alarm reset time (Toff). The
parameter value can be set in an interval from 10 seconds to 9999
seconds. Press the key to conrm and exit the conguration menu.
Time
Power Load disconnection
Setpoint
Ton Toff
12. ACTIVATION THRESHOLD EXCEEDED
If the absorbed power exceeds the set
activation threshold (Setpoint), the icon ,
the measured value and the red alarm LED will
start ashing on the device. If the absorbed
power remains greater than the set activation
threshold (Setpoint) for a time longer than the
time set in the prealarm parameter (Ton), the
MD3300MRP device disconnects the loads
(one every 5 seconds), starting from that with
lowest priority (channel 1 = priority 1 = highest
priority) until the absorbed power falls below
the activation threshold (Setpoint). Then the
device provides the loads connection (one
every 5 seconds) in reverse order, when the
alarm reset time (Toff) has elapsed.
The transmission of commands to radio receivers is shown by the
lighting of the icon on the device display.
13. ECO OPERATION
By pressing for a long time (3 seconds) the key you can disable the
control of the control unit MD3300MRP so as to force all loads to remain
active even if the absorbed power exceeds the set threshold (Setpoint).
This condition is indicated by the symbol switch on.
Upon activation, the loads that are disconnected are activated (in sequence
from the most priority load) every 5 seconds.
To disable the ECO function, press and hold the key until the icon
turns off.
10. CHANNEL CONFIGURATION MENU (PRIORITY)
Setpoint Ton Channel conguration menu
PARAMETER CONFIGURATION MENU
0,8÷7 Kw 10÷9999 s 10÷9999 s
New assignment Assignment removal Test
CH N÷ 8 CH N÷ 8
Procedure completed
Procedure failed
>2 sec.
>2 sec.
CHANNEL CONFIGURATION MENU
MADE IN FRANCE
2) Assigning the receiver module to the MD3300MRP load manager
▶When the Radio Bus has been created, assign the MTR receiver module
which pilots the load to the MD3300MRP load manager following the
procedure described in paragraph “Radio assignment between an MTR
receiver module and the MD3300MRP load manager”.
After performing the RADIO assignment between the receiver modules
and the MD3300MRP load manager, it is necessary to make the assignment
between the receiver modules and the device channels, so as to indicate to
the MD3300MRP load manager which receiver modules are to be piloted
according to the priorities.
The MD3300MRP device is able to manage up to 8 channels, each with
a different priority: channel 1 = priority 1 = highest priority.
DS1054-074B
ASSIGNING AN MTR RECEIVER MODULE TO A CHANNEL
▶On the MD3300MRP load manager, access the PARAMETER conguration
menu by pressing the key . The icons /and “kW” will start
ashing.
▶Press the arrow key or until the icons and ash on the
display. Press the key to enter the CHANNEL conguration menu.
▶The device display shows “Add CH”. Press the key to assign the
receiver module to the channel.
▶The display shows “CH N. .8” where the parameter “N” indicates the
channel number (from 1 to 8) where the assignment to the receiver module
is made, the parameter 8indicates the maximum number of channels.
It is recommended to perform the assignment starting with the
channels with the highest priority. Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C - For technical information, go to www.yokis.com or call:
Customer Service: +39 011.23.39.810 - export dept. Phone: +39 011.24.00.250/256
▶Press the arrow keys or to select the channel “N” on which you want
to perform the assignment. Press the key to conrm.
▶While “InProG” is ashing for 30 seconds, press briey with a sharp, properly
insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP device will briey display the message “PASS” if the
assignment of the channel to the receiver module has been successful.
▶If the device displays the message “Err. 03” the assignment has not been
successful. Repeat the operation and make sure to press into the “Connect”
hole on the receiver module within the 30 seconds in which the MD3300MRP
load manager displays the message “InProG”.
▶It is necessary to repeat the procedure for each receiver module you wish to
assign to a channel of the MD3300MRP device.
It is possible to assign more than one receiver module to each channel.
In this case, if the absorption threshold is exceeded, there will be two
or more loads disconnecting at the same time.
REMOVING AN ASSIGNMENT BETWEEN AN MTR RECEIVER MODULE
AND A CHANNEL
It is possible to remove an assignment between an MTR receiver module and
a channel of the MD3300MRP device.
▶On the MD3300MRP device, access the PARAMETER conguration menu by
pressing the key . The icons /and “kW” will start ashing.
▶Press the arrow key or until the icons and ash. Press the key
to enter the CHANNEL conguration menu.
▶The device display shows “Add CH”. Press the arrow keys or until
“dEL CH” is displayed, press the key to remove an assignment.
▶“InProG” is displayed.
▶While “InProG” is ashing for 30 seconds, press briey with a sharp, properly
insulated tool into the “Connect” hole on the receiver module.
▶The MD3300MRP device will briey display the message “PASS” if the
assignment removal between the channel and the receiver module has been
successful.
▶If the device displays the message “Err. 03” the assignment removal has
not been successful. Repeat the operation and make sure to press into the
“Connect” hole on the receiver module within the 30 seconds in which the
MD3300MRP load manager displays the message “InProG”.
▶It is necessary to repeat the entire procedure for each assignment you wish
to remove.
TEST FUNCTION
The test function is used to check that the assignment between the receiver
module and the MD3300MRP load manager (i.e. the relevant channel) is
working correctly. The test involves a switching on and off sequence (one
every 10 seconds) of the receiver module.
▶On the MD3300MRP load manager, access the PARAMETER conguration
menu by pressing the key . The icons / and “kW” will start
ashing.
▶Press the arrow key or until the icons and ash on the display.
Press the key to enter the CHANNEL conguration menu.
▶The device display shows “Add CH”. Press the arrow keys or until
“test” is displayed, press the key to test a channel.
▶The display shows “CH N. .8” where the parameter “N” indicates the channel
number (from 1 to 8) where the test is performed, the parameter 8indicates
the maximum number of channels.
▶Press the arrow keys or to select the channel “N” on which you want
to perform the test. Press to conrm.
▶Every time the command is transmitted, the icon ashes for a few
seconds while the alarm LED, located between the keys or , shows
the transmission status:
LED on = actuation ON
LED off = actuation OFF
It is possible to interrupt the test by pressing .
▶The MD3300MRP device briey displays the message “PASS” at the end of
the test.
11. OPERATING PARAMETER CONFIGURATION MENU
The following operating parameters can be congured through the parameter
conguration menu:
- Setpoint (kW)
- Ton (seconds)
- Toff (seconds)
When a parameter has been congured, the device automatically
switches to the next parameter conguration. To exit the parameter
conguration menu, simply press the key.
When conguring parameters, long presses of the arrow key or
allows changing the values more quickly.
SETPOINT (kW)
Represents the activation threshold that is to say the maximum value of
accepted consumption. Over this value the MD3300MRP device provides
for the disconnection of the lowest priority load that is connected in that
moment.
▶On the MD3300MRP device, access the PARAMETER conguration menu by
pressing the key. The icons / and “kW” will start ashing. Press
the key for Setpoint conguration.
▶On the display, the icons / will be steady on and the Setpoint
parameter value will start ashing.
▶Press the arrow keys or to set the Setpoint parameter. The
parameter value can be set in an interval from 0.8 kW to 7kW. Press the
key to conrm and go to the next parameter conguration.
Ton (seconds)
Represents the pre-alarm time, that is to say how long the power must be
higher than the setpoint before the load is actually disconnected.
▶On the display, the icons / will be steady on and the prealarm time
value (Ton) will start ashing.
▶Press the arrow keys or to set the prealarm time (Ton). The
parameter value can be set in an interval from 10 seconds to 9999
seconds. Press the key to conrm and go to the next parameter
conguration.
Toff (seconds)
Represents the recovery time, that is to say after how long the most priority
load, disconnected in that moment, is reconnected.
The load is connected only if the absorbed power is lower than the
set power threshold.
▶On the display, the icons / / will be steady on and the alarm
reset time value (Toff) will start ashing.
▶Press the arrow keys or to set the alarm reset time (Toff). The
parameter value can be set in an interval from 10 seconds to 9999
seconds. Press the key to conrm and exit the conguration menu.
Time
Power Load disconnection
Setpoint
Ton Toff
12. ACTIVATION THRESHOLD EXCEEDED
If the absorbed power exceeds the set
activation threshold (Setpoint), the icon ,
the measured value and the red alarm LED will
start ashing on the device. If the absorbed
power remains greater than the set activation
threshold (Setpoint) for a time longer than the
time set in the prealarm parameter (Ton), the
MD3300MRP device disconnects the loads
(one every 5 seconds), starting from that with
lowest priority (channel 1 = priority 1 = highest
priority) until the absorbed power falls below
the activation threshold (Setpoint). Then the
device provides the loads connection (one
every 5 seconds) in reverse order, when the
alarm reset time (Toff) has elapsed.
The transmission of commands to radio receivers is shown by the
lighting of the icon on the device display.
13. ECO OPERATION
By pressing for a long time (3 seconds) the key you can disable the
control of the control unit MD3300MRP so as to force all loads to remain
active even if the absorbed power exceeds the set threshold (Setpoint).
This condition is indicated by the symbol switch on.
Upon activation, the loads that are disconnected are activated (in sequence
from the most priority load) every 5 seconds.
To disable the ECO function, press and hold the key until the icon
turns off.
10. CHANNEL CONFIGURATION MENU (PRIORITY)
Setpoint Ton Channel conguration menu
PARAMETER CONFIGURATION MENU
0,8÷7 Kw 10÷9999 s 10÷9999 s
New assignment Assignment removal Test
CH N÷ 8 CH N÷ 8
Procedure completed
Procedure failed
>2 sec.
>2 sec.
CHANNEL CONFIGURATION MENU
MADE IN FRANCE
2) Assigning the receiver module to the MD3300MRP load manager
▶When the Radio Bus has been created, assign the MTR receiver module
which pilots the load to the MD3300MRP load manager following the
procedure described in paragraph “Radio assignment between an MTR
receiver module and the MD3300MRP load manager”.
After performing the RADIO assignment between the receiver modules
and the MD3300MRP load manager, it is necessary to make the assignment
between the receiver modules and the device channels, so as to indicate to
the MD3300MRP load manager which receiver modules are to be piloted
according to the priorities.
The MD3300MRP device is able to manage up to 8 channels, each with
a different priority: channel 1 = priority 1 = highest priority.

This manual suits for next models

1

Other Yokis Relay manuals

Yokis MTR2000 User manual

Yokis

Yokis MTR2000 User manual

Yokis MTR2000ERX User manual

Yokis

Yokis MTR2000ERX User manual

Yokis MTR500 Series User manual

Yokis

Yokis MTR500 Series User manual

Popular Relay manuals by other brands

IME RD1GP manual

IME

IME RD1GP manual

IFM BasicController CR0431 Programming manual

IFM

IFM BasicController CR0431 Programming manual

Woodward MFD 11 Packages manual

Woodward

Woodward MFD 11 Packages manual

ABB TA 200 DU V1000 operating instructions

ABB

ABB TA 200 DU V1000 operating instructions

Basler BE1-59N instruction manual

Basler

Basler BE1-59N instruction manual

ABB CM-MSS.12 Operating and installation instructions

ABB

ABB CM-MSS.12 Operating and installation instructions

Freelap Relay Coach BLE quick start guide

Freelap

Freelap Relay Coach BLE quick start guide

IDEC LD6A Series instruction sheet

IDEC

IDEC LD6A Series instruction sheet

Omron K8DT-PM manual

Omron

Omron K8DT-PM manual

Eaton Digitrip 3000 series Installation, operation and maintenance instructions

Eaton

Eaton Digitrip 3000 series Installation, operation and maintenance instructions

Schweitzer Engineering Laboratories SEL-751 instruction manual

Schweitzer Engineering Laboratories

Schweitzer Engineering Laboratories SEL-751 instruction manual

Omron MK-S -  2 datasheet

Omron

Omron MK-S - 2 datasheet

OEZ MINIA RPI-16-001-X230-S Series Instructions for use

OEZ

OEZ MINIA RPI-16-001-X230-S Series Instructions for use

KUSSMAUL 091-63-OV instruction manual

KUSSMAUL

KUSSMAUL 091-63-OV instruction manual

Pilz PNOZ X7.1 operating manual

Pilz

Pilz PNOZ X7.1 operating manual

WEG CPW17 user manual

WEG

WEG CPW17 user manual

Tekmar 304P Installation & operation manual

Tekmar

Tekmar 304P Installation & operation manual

Woodward HighProTec Series troubleshooting guide

Woodward

Woodward HighProTec Series troubleshooting guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.