YOKOGAWA WU10 User manual

IM 12B06W02-02EN-P
1st edition
Instruction
Manual
Model WU10, WF10 and WE10
VP cable and extension cable

2
IM 12B06W02-02EN-P
Contents
1. PREFACE.....................................................................................................................3
1.1 Introduction........................................................................................................3
1.2 Unpacking & Checking.......................................................................................3
1.3 Warranty & Service............................................................................................3
1.4 Serial number.....................................................................................................4
2. GENERAL SPECIFICATIONS......................................................................................5
2.1 WU10 Single coax cable....................................................................................5
2.2 WU10/WF10 Dual coax cable ............................................................................7
2.3 WE10 Dual coax cable XL..................................................................................9
2.4 Environmental conditions.................................................................................11
2.5 Shipping details................................................................................................11
3. INSTALLATION..........................................................................................................12
3.1 Connections of VP Single coax cable WU10-V-S.............................................12
3.2 Connections of VP Dual coax cable WU10-V-D, WF10 and WE10...................13
4. DIMENSIONS..............................................................................................................17
5. MODEL CODES..........................................................................................................19
6. SPARE PARTS...........................................................................................................19
Appendix 1. Protection of environment.......................................................................20

3
IM 12B06W02-02EN-P
1. PREFACE
1.1 Introduction
This instruction manual provides
information for the installation and use of
the WU10/WF10 and WE10 cable. This
universal sensor cable is specified for
reliable transfer of analog signals and
especially designed to be installed in a
heavy industrial environment.
This multicore shielded cable is available in
different lengths, as a single and a dual
coax version. The shielded cable will
protect both the sensor and the analyzer
for interference from high voltages and
currents which are present on other cables
running in the same cable tray.
The WU10/WF10 and WE10 cables can be
used in an explosive atmosphere and
hazardous areas when used with
appropriate accessories and certified
sensors.
1.2 Unpacking & Checking
Upon delivery, unpack the product inspect
it to ensure that it is not damaged during
shipment. If damage is found, retain the
original packing material, and immediately
notify the carrier and the relevant local
Yokogawa Sales office.
Make sure the Model Code and Serial
Number on the product are the same as on
the packing list. Also check if option(s) that
were ordered are included and correct.
1.3 Warranty & Service
Yokogawa products are guaranteed free
from defects in workmanship and materials
under normal use and service for a period
of (typically) 12 months from the date of
shipment from the manufacturer. Individual
Sales organizations can deviate from the
typical warranty period, and the conditions
of sale relating to the original purchase
order should be consulted.
Damage caused by wear and tear,
inadequate maintenance, corrosion, or
by the effects of chemical processes is
excluded from this warranty coverage.
In the event of a warranty claim, the
defective goods should be sent (freight
paid) to the Service Department of the
relevant Yokogawa Sales office for repair
or replacement (at Yokogawa’s discretion).
The following information must be included
in the letter accompanying the returned
goods:
•Model Code and Serial Number.
•Original Purchase Order and Date.
•Length of time in service and
description of the process.
•Description of the fault and
circumstances of the failure.
•Process/environmental conditions that
may be related to the failure of the
cable.
•Statement as to whether warranty or
non-warranty service is requested.
•Complete shipping and billing
instructions for return of material, plus
the name and phone number of a
contact person that can be reached
for further information.
•Clean Statement Returned goods that
have been in contact with process
fluids must be decontaminated and
disinfected prior to shipment.
Goods should carry a certificate to this
effect, for the health and safety of our
employees. Material Safety Data sheets
must be included for all components of
the process to which the cable has been
exposed.

4
IM 12B06W02-02EN-P
1.4 Serial number
The Serial number is defined by nine (9)
alphanumeric characters:
X1X2Production location
X3X4Year/Month code
X5X6X7X8X9Tracking number
Example: N3Y295015
Table 1: Production Year code
Year
Year
code
Year
Year
code
2014
P
2026
3
2015
R
2027
4
2016
S
2028
5
2017
T
2029
6
2018
U
2030
7
2019
V
2031
8
2020
W
2032
9
2021
X
2033
A
2022
Y
2034
B
2023
Z
2035
C
2024
1
2036
D
2025
2
2037
E
Table 2: Production Month code
Month
Month code
January
1
February
2
March
3
April
4
May
5
June
6
July
7
August
8
September
9
October
A
November
B
December
C

5
IM 12B06W02-02EN-P
2. GENERAL SPECIFICATIONS
2.1 WU10 Single coax cable
Model WU10-V-S-..-..
Type Single coax cable with VarioPin (VP) connector and wire pin finish
Construction Multicore shielded cable with one low noise coax and three insulated
wires and drain wire
Tabel 3: WU10-V-S single coax cable properties, part 1
Model
WU10-V-S-..-..
Type:
Single coax cable
Mechanical specifications
Outer diameter:
6.5 mm ± 0.2 mm
Bending radius:
• Fixed installation
≥ 10x outer diameter
• Frequently bending
≥ 15x outer diameter
Conductors:
• Coax
Tin plated copper 7 x 0.2 mm (0.22 mm2)
• Wires
Tin plated copper 19 x 0.18mm (0.5 mm2)
• Drain wire
Tin plated copper 7 x 0.2 mm (0.22 mm2)
Insulation materials:
• Outer jacket
Polyvinylchloride (PVC)
• Coax dielectric
Polyethylene (HDPE)
• Coax sheath
Polyethylene (TPE-O)
• Wires
Polyolefin
Filler:
PP
Low noise layer:
Conductive film
Shielding:
• Braiding
Tinned copper wires 0.10mm
optical covering nom. 90%
• Foil shield
Aluminum-coated polyester foil, 30%
overlap.
Finishing:
6-P VP Female + wired pin
Colors:
• Outer jacket
Black
• Coax
Brown
• Wires
Black, Red, Blue
• Drain wire
Yellow
Weight cable:
60.0kg/km

6
IM 12B06W02-02EN-P
Tabel 4: WU10-V-S single coax cable properties, part 2
Model
WU10-V-S-..-..
Description:
Single coax cable
Electrical specifications:
Resistance: (@ 20°C)
Lead 19 x 0.18mm
Lead 7 x 0.2 mm
Drain wire
≤ 40 Ω/km
≤ 80 Ω/km
≤ 45 Ω/km
Capacitance:
• Coax (conductor-shield)
≤ 120 pF/m
• Coax (conductor-overall shield)
≤ 100 pF/m
• Coax (shield-overall shield)
• Lead 19 x 0.18 (cond.-overall shield)
• Lead 7 x 0.2 (cond.-overall shield)
Total cable conductance
≤ 400 pF/m
≤ 150 pF/m
≤ 125 pF/m
≤ 0.8 nF/m
Mechanically induced noise: MIL-C-
17G
≤ 5 mV
Insulation resistance:
• Coax (conductor-shield)
> 1 x 1013Ω*cm
• Conductor-overall shield
> 1 x 1013Ω*cm
Operating voltage:
150V
Operating temperature:
•20.000 hrs
•1.000 hrs
-20°C…+90°C (-4°F…+194°F)
-20°C…+105°C (-4°F…+221°F)
Others:
ROHS
YES
Halogen Free
NO
Flame retardant
YES (acc. IEC 60332-1-2)
UV resistant
NO
Oil resistant
NO
Fire properties
///
Smoke properties
///
EPA
YES
Figure 1: cable layout single coax Figure 2: VP-6 pin female

7
IM 12B06W02-02EN-P
2.2 WU10/WF10 Dual coax cable
Model WU10-V-D-..-.. WF10-…
Type Dual coax cable with Cable without connector (-FF) for use
Vario pin and wire pin finish as extension cable with BA10 terminal
extension box
Construction Multicore shielded cable with two low noise coaxes and four insulated
wires
Tabel 5: WU10-V-D and WF10 dual coax cable properties, part 1
Model
WU10-V-D-..-.. and WF10-…
Type:
Dual coax cable
Mechanical specifications
Outer diameter:
7.0 mm ± 0.2 mm
Bending radius:
• Fixed installation
≥ 10x outer diameter
• Frequently bending
≥ 15x outer diameter
Conductors:
• Coax
Tin plated copper 19 x 0.14mm (0.3 mm2)
• Wires
Tin plated copper 19 x 0.14mm (0.3 mm2)
• Drain wire
Tin plated copper 19 x 0.14mm (0.3 mm2)
Insulation materials:
• Outer jacket
Thermoplastic Rubber (TPK)
• Coax dielectric
Thermoplastic Rubber (TPK)
• Coax sheath
Thermoplastic Rubber (TPK)
• Wires
Thermoplastic Rubber (TPK)
Filler:
Cotton
Low noise layer:
Conductive film
Shielding:
• Braiding
Tinned copper wires 0.10mm
optical covering nom. 85%
• Foil shield
Aluminum-coated polyester foil, 30%
overlap.
Finishing:
WU10: 8-P VP + wired pin
WF10: Finish wire pins or no finish
Colors:
• Outer jacket
Black
• Coax
Brown, White
• Wires
Red, Blue, Yellow, Green
• Drain wire
Black
Weight cable:
75.5kg/km

8
IM 12B06W02-02EN-P
Tabel 6: WU10-V-D dual coax cable properties, part 2
Model
WU10-V-D-..-.. and WF10-…
Type:
Dual coax cable
Electrical specifications:
Resistance: (@ 20°C)
Lead 19 x 0.14mm
Drain wire
≤ 45Ω/km
≤ 45Ω/km
Capacitance:
• Coax (conductor-shield)
≤ 180 pF/m
• Coax (conductor-overall shield)
≤ 110 pF/m
• Coax (shield-overall shield)
• Lead 19 x 0.14 (cond.- overall shield)
Total cable conductance
≤ 350 pF/m
≤ 150 pF/m
≤ 1.3 nF/m
Mechanically induced noise: MIL-C-
17G
≤ 5 mV
Insulation resistance:
• Coax (cond,-shield)
> 1 x 1013Ω*cm
• Conductor-overall shld
> 1 x 1013Ω*cm
Operating voltage:
150V
Operating temperature:
•20.000 hrs
•3.000 hrs
-30°C …+105°C (-22°F…+ 221°F)
-20°C …+125°C (-4°F… + 257°F)
Others:
ROHS
YES
Halogen Free
NO
Flame retardant
YES (acc. IEC 60332-1-2)
UV resistant
NO
Oil resistant
NO
Fire properties
///
Smoke properties
///
EPA
YES
Figure 3: cable layout Dual coax Figure 4: VP-8 pin female

9
IM 12B06W02-02EN-P
2.3 WE10 Dual coax cable XL
Model WE10-H-D-...-..
Type Dual coax cable XL
- Female connector with wire pins for direct connection to
terminals
- With female-male connector as extension cable
- or without connectors for use as extension cable with BA10
terminal extension box
Construction Multicore shielded cable with two low noise coaxes and four insulated
wires, halogen free.
Tabel 7: WE10 Dual coax cable XL properties, part 1
Model
WE10-H-D-...-..
Type:
Dual coax cable XL
Mechanical specifications
Outer diameter:
8.3 mm ± 0.2 mm
Bending radius:
• Fixed installation
≥ 5x outer diameter
• Frequently bending
≥ 12x outer diameter
Conductors:
• Coax
Tin plated copper 19 x 0.15 mm (0.34 mm2)
• Wires
Tin plated copper 19 x 0.15 mm (0.34 mm2)
• Drain wire
///
Insulation materials:
• Outer jacket
XL TPE-E
• Coax dielectric
Polyethylene (TPE-O)
• Coax sheath
Polyethylene (TPE-O)
• Wires
Polyethylene (TPE-O)
Filler:
Glass fiber yam
Low noise layer:
Conductive film
Shielding:
• Braiding
Tinned copper wires 0.10mm,
optical covering nom. 85%
• Foil shield
Aluminized polyester foil.
Conductive side to braided shield
optical coverage 100%
Finishing:
8-P VP + wired pin
8-P VP male-female
Finish wired pins, No finish
Colors:
• Outer jacket
Black
• Coax
Brown
• Wires
Black, Red, Blue, Yellow
Weight cable:
112kg/km

10
IM 12B06W02-02EN-P
Tabel 8: WE10 Dual coax cable XL properties, part 2
Model
WE10-H-D-...-..
Description:
Dual coax cable XL
Electrical specifications:
Resistance: (@ 20°C)
• Lead 19 x 0.15mm
≤ 57Ω/km
Capacitance:
• Coax (conductor-shield)
≤ 225 pF/m
• Coax (conductor-overall shield)
≤ 150 pF/m
• Coax (shield-overall shield)
• Lead 19 x 0.15 (cond.-overall shield)
Total cable capacity
≤ 400 pF/m
≤ 180 pF/m
≤ 1.5 nF/m
Mechanically induced noise: MIL-C-17G
≤ 5 mV
Insulation resistance:
• Coax (cond,-shield)
> 1 x 1013Ω*cm
• Conductor-overall shld
> 1 x 1013Ω*cm
Operating voltage:
450V
Operating temperature:
•20.000 hrs
•3.000 hrs
-20°C…+105°C (-4°F…+ 221°F)
-20°C …+125°C (-4°F… + 257°F)
Others:
ROHS
YES
Halogen Free
YES (EN 50267-2-2 / IEC 60754-2)
Flame retardant
YES (acc. IEC 60332-1)
UV resistant
YES (outer jacket)
Oil resistant
YES (72 h / (100 ± 2)°C / IRM 902)
Fire properties
IEC 60332-1-2 / IEC 60332-3-24
Smoke properties
IEC 61034-2 >60% (light transmission)
EPA
YES
Figure 6: 8-pin VP male
Top-view
Figure 5: cable layout Dual coax
Figure 7: 8-pin VP female
inside-view

11
IM 12B06W02-02EN-P
2.4 Environmental conditions
Storage temperature : -10°C to +50 ºC (14 to 122 ºF)
Ingress Protection VP connector1: IP67 (conform IEC 60529)
Hazardous areas2: The WU10/WF10 and WE10 cables can be
used in an explosive atmosphere and
hazardous areas when used with appropriate
accessories and certified sensors.
Note 1: VP connector is IP67 rated when properly connected to a IP67 or better rated
sensor or extension cable.
Note 2: Please check “Control Drawing” of specific sensor or analyzer for the specific
conditions of use.
2.5 Shipping details
Type
Package size (LxWxH)
Package weight (max.)
model
mm (inch)
g
lbs
WU10-V-S-02
220 x 220 x 90 (8.7x8.7x3.6)
368
0.811
WU10-V-S-05
220 x 220 x 90 (8.7x8.7x3.6)
550
1.213
WU10-V-S-10
220 x 220 x 90 (8.7x8.7x3.6)
860
1.896
WU10-V-S-15
220 x 220 x 90 (8.7x8.7x3.6)
1135
2.502
WU10-V-S-20
220 x 220 x 90 (8.7x8.7x3.6)
1470
3.241
WU10-V-D-02
220 x 220 x 90 (8.7x8.7x3.6)
387
0.85
WU10-V-D-05
220 x 220 x 90 (8.7x8.7x3.6)
600
1.323
WU10-V-D-10
220 x 220 x 90 (8.7x8.7x3.6)
928
2.046
WU10-V-D-15
220 x 220 x 90 (8.7x8.7x3.6)
1314
2.897
WU10-V-D-20
220 x 220 x 90 (8.7x8.7x3.6)
1676
3.695
WE10-H-D-003-V1
220 x 220 x 90 (8.7x8.7x3.6)
615
1.356
WE10-H-D-003-V2
220 x 220 x 90 (8.7x8.7x3.6)
615
1.356
WE10-H-D-002-VF
220 x 220 x 90 (8.7x8.7x3.6)
460
1.014
WE10-H-D-005-VF
220 x 220 x 90 (8.7x8.7x3.6)
796
1.755
WE10-H-D-010-VF
220 x 220 x 90 (8.7x8.7x3.6)
1356
2.989
WE10-H-D-020-VF
220 x 220 x 90 (8.7x8.7x3.6)
2476
5.459
WE10-H-D-050-NN
460 x 350 x 300 (18.1x13.8x11.8)
5850
12.897
WE10-H-D-100-NN
460 x 350 x 300 (18.1x13.8x11.8)
11450
25.243
WE10-H-D-200-NN
500 x 500 x 270 (19.7x19.7x10.6)
22650
49.935
WE10-H-D-005-FF
220 x 220 x 90 (8.7x8.7x3.6)
673
1.484
WE10-H-D-010-FF
220 x 220 x 90 (8.7x8.7x3.6)
1233
2.718
WE10-H-D-020-FF
220 x 220 x 90 (8.7x8.7x3.6)
2353
5.187
WE10-H-D-050-FF
460 x 350 x 300 (18.1x13.8x11.8)
5850
12.897

12
IM 12B06W02-02EN-P
3. INSTALLATION
3.1 Connections of VP Single coax cable WU10-V-S
Parameter pH Conventional
pH Conventional is a combined sensor with high ohmic pH membrane and low ohmic internal
reference. For ORP and pH-differential measurement the WU10-V-S cannot be used.
For these measurements the WU10-V-D or WE10 is necessary
WU10-V-S
Color
VP pin
EXA/FLXA terminal no.
Description
Coax core
brown
A
15
pH input
Coax shield
brown
B
13
Ref input
Wire
black
C
16
pH guard
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Drain wire
yellow
D
14
Liquid Earth (LE)
Parameter pH differential
For pH differential the WU10-V-S cannot be used, for this parameter the WU10-V-D or WE10 is
necessary
Parameter SC
For SC the WU10-V-S cannot be used, for this parameter the WU10-V-D or WE10 is
necessary
Parameter ISC
For ISC the WU10-V-S cannot be used, for this parameter the WU10-V-D or WE10 is
necessary
Parameter DO-galvanic
WU10-V-S
Color
VP pin
EXA/FLXA terminal no.
Description
Coax core
brown
A
13
Cathode
Coax shield
brown
B
15
Anode
Wire
black
C
16
Membrane check
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Drain wire
yellow
D
14
Shield
Parameter DO-Polarographic
WU10-V-S
Color
VP pin
EXA/FLXA terminal no.
Description
Coax core
brown
A
17
Cathode
Coax shield
brown
B
18
Anode
Wire
black
C
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Drain wire
yellow
D
14
Shield/Liquid Earth (LE)
Parameter LDO
For LDO the WU10-V-S cannot be used, for this parameter the WU10-V-D or WE10 is
necessary

13
IM 12B06W02-02EN-P
3.2 Connections of VP Dual coax cable WU10-V-D, WF10 and WE10
Parameter pH conventional + ORP
pH conventional is where combined sensor with high ohmic pH membrane and low ohmic
internal reference.
WU10-V-D,
WF10, WE10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
15
pH input
Coax1 shield
brown
B
13
Ref input
Coax2 core
white
C
16
pH guard
Coax2 shield
white
D
14
Liquid Earth (LE)
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
Not connected
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield
Parameter ORP (for pH conventional)
WU10-V-D,
WF10, WE10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
Not connected
Coax1 shield
brown
B
13
Ref input
Coax2 core
white
C
Not connected
Coax2 shield
white
D
15 & 14
(interconnected)
Metal / Liquid
Earth (LE)
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
Not connected
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield
Parameter ORP (pH compensated, for pH conventional)
WU10-V-D, WE10
Color
VP pin
EXA/FLXA terminal
no.
Description
Coax1 core
brown
A
13
pH input
Coax1 shield
brown
B
Ref input
Coax2 core
white
C
17
pH guard
Coax2 shield
white
D
15 & 14
(interconnected)
Liquid Earth (LE)
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
Not connected
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield

14
IM 12B06W02-02EN-P
Parameter pH differential + ORP
pH differential is where the combined sensor has two dissimilar glass membranes
WU10-V-D,
WF10, WE10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
15
pH input
Coax1 shield
brown
B
16
pH guard
Coax2 core
white
C
13
Ref input
Coax2 shield
white
D
17
Ref guard
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
14
Liquid Earth (LE)
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield
Parameter ORP (for pH differential)
WU10-V-D,
WF10, WE10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
13
Not connected
Coax1 shield
brown
B
Not connected
Coax2 core
white
C
17
Ref input
Coax2 shield
white
D
15 & 14 (interconnected)
Ref guard
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
Metal/Liquid Earth (LE)
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield
Parameter ORP (pH compensated for pH differential)
WU10-V-D,
WF10, WE10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
13
Ref input
Coax1 shield
brown
B
17
Ref guard
Coax2 core
white
C
Not connected
Coax2 shield
white
D
Not connected
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
15 & 14 (interconnected)
Metal / Liquid Earth (LE)
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield

15
IM 12B06W02-02EN-P
Parameter SC
WU10-V-D,
WF10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
15
Ui (inner electrode)
Coax1 shield
brown
B
16
Ii (Inner electrode)
Coax2 core
white
C
13
Uo (Outer electrode)
Coax2 shield
white
D
14
Io (Outer electrode)
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
Not connected
Wire
green
H
Not connected
Drain wire
black
shield
63 (4W analyzer only)
Shield
Parameter ISC
WU10-V-D,
WF10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
13
Receive coil high
Coax1 shield
brown
B
17
Receive coil low
Coax2 core
white
C
15
Drive coil high
Coax2 shield
white
D
16
Drive coil low
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
14
Sensor shield
Wire
green
H
Not connected
Drain wire
Black
Shield
63 (4W analyzer only)
Shield

16
IM 12B06W02-02EN-P
Parameter DO - galvanic
WU10-V-D,
WF10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
13
Cathode
Coax1 shield
brown
B
15
Anode
Coax2 core
white
C
Not connected
Coax2 shield
white
D
Not connected
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
16
Membrane check
Wire
green
H
Not connected
Drain wire
black
Shield
14
Shield
Parameter DO - polarographic
WU10-V-D,
WF10
Color
VP pin
EXA/FLXA terminal no.
Description
Coax1 core
brown
A
17
Cathode
Coax1 shield
brown
B
18
Anode
Coax2 core
white
C
Not connected
Coax2 shield
white
D
Not connected
Wire
red
E
11
Pt1000-T1
Wire
blue
F
12
Pt1000-T2
Wire
yellow
G
Not connected
Wire
green
H
Not connected
Drain wire
black
Shield
14
Shield
Parameter LDO
WU10-V-D,
WE10-VF
Color
VP pin
FLXA terminal no.
Description
Coax1 core
brown
A
Not connected
Coax1 shield
brown
B
Not connected
Coax2 core
white
C
10
Power supply +
Coax2 shield
white
D
13
Power supply -
Wire
red
E
Not connected
Wire
blue
F
Not connected
Wire
yellow
G
11
RS485 Data –(A)
Wire
green
H
12
RS485 Data + (B)
Shield / Drain
wire
black
Shield
14
Cable shield

17
IM 12B06W02-02EN-P
4. DIMENSIONS
Dimensions in mm [inches]
Figure 8: Dimensions WU10-V-S (left) and WU10-V-D and WE10-H-D (right)
WE10 Ø=8.3 ±0.2
[0.33±0.01]
WU10 Ø=7.0 ±0.2
[0.28±0.01]
WU10 Ø=6.5 ±0.2
[0.26±0.01]
WU10-V-S
WU10-V-D
WE10-H-D

18
IM 12B06W02-02EN-P
Figure 9: WF10 (suffix -N) and WE10 (suffix -NN) without cable finishing
Figure 10: WF10 (suffix -F) and WE10 (suffix -FF) with wire pin cable finishing
Figure 11: WE10-H-003-V1(V2)
WE10 Ø=8.3 ±0.2
[0.33±0.01]
WF10-***-N Ø=7.0 ±0.2
[0.28±0.01]
WF10-***-F Ø=7.0 ±0.2
[0.28±0.01]
WE10 Ø=8.3 ±0.2
[0.33±0.01]

19
IM 12B06W02-02EN-P
5. MODEL CODES
Model Code
Suffix code
Description
WU10
Sensor cable
Connection type
-V
Variopin
Cable type
-S
-D
Single coax
Dual coax
Cable length
-02
-05
-10
-15
-20
2 meters
5 meters
10 meters
15 meters
20 meters
Model Code
Suffix code
Description
WF10
Connecting cable
Length in m
-005 up to and including
200
Length in meter between 005
and 200 with multiple of 5 meter.
Finishing
-F
-N
Finished
Not finished
Model Code
Suffix code
Description
WE10
Generic cable
Material
-H
Halogen free/low smoke/flame retardant
-D
Dual coax
Cable Length
-002
-003
-005
-010
-020
-050
-100
-200
2 m (-VF finishing)
2.95 m (-V1, V2 finishing)
5 m (-FF, -VF finishing)
10 m (-FF, -VF finishing)
20 m (-FF, -VF finishing)
50 m (-FF, -NN finishing)
100 m (-NN finishing)
200 m (-NN finishing)
Finishing
-FF
-V1
-V2
-VF
-NN
Both ends wire pins finish
Variopin male- female (pH conv.)
Variopin male- female (universal)
Variopin Female wire pins
No finish
Note: V1 –for Smart Adapter, model SA11-P1
V2 –for Smart Adapter, model SA11-P2, SA11-C1
VF –for connection Vario pin sensors (e.g. FU20, FU24, SC25 and DO72)
6. SPARE PARTS
Spare parts for Vario pin cables
Part no.
Description
Quantity
K1548GF
O-ring for Female VP connector
5

20
IM 12B06W02-02EN-P
Appendix 1. Protection of environment
Protection of Environment (Use in China)
这个标志是基于SJ/T11364,在中国(不包括台湾,香港,澳门)贩售
的电子电器
产品所适用的环境保护期限,6种有害物质的含有量都低于GB/T26572所
规定的限
量要求以下。
Production date
关于生产日期
生产日期在产品铭牌上9位数的序列号中,用以下形式表示生产日期。
从左数第3位数:生产年份
R:2015,S:2016,T:2017,U:2018,V:2019,W:2020,X:2021,Y:2022,Z:2023,
1:2024,2:2025,3:2026,…
从左数第4位数:生产月份
1:1月,2:2月,3:3月,…,9:9月,A:10月,B:11月,C:12月
(示例)N3S700001:2016年7月
IM 12B06W02-02EN-P Printed in The Netherlands, 01-2112
Subject to change without notice
Copyright ©
Other manuals for WU10
1
This manual suits for next models
31
Table of contents
Other YOKOGAWA Cables And Connectors manuals