2

66
31.53 SD Card:
31.531 Playback from SD Card:
Capacity of the SD card is shown. Click the date listed on the page.
1. The video MPEG4 is in AVI format. If media player can’t play the video files,
please install the decoder program at ftp://59.120.66.60/Tools/ffdshow.exe
2. When the SD card is full, it will overwrite the oldest video files automatically.
31.532 Record Setting: Modify Pre/ Post Alarm seconds (Each 0~5 seconds).
3
SAFETY WARNING
Before using this product, please read installation instructions carefully
and remove the protective lining from the dome before proceeding with
set up.
In case of failure, disconnect power or remove power supply before contact
our service personnel.
To avoid electric shocks, do not disassemble this product on your own. Be
sure to ask a skilled technician for the job.
Use enclosed power supply only. Do not use other type of power supply, or
the product may be damaged or fire can be triggered.
Keep unconnected wires, plugs, duly insulated, or they might cause short
circuit and damage this product.
Do NOT connect power to the unit until all installation steps are completed.
Do not turn the camera lens with your hand, doing so might damage camera.
Do not point this camera to the sun or a shining object, do not put it on a
static object; doing so might damage the camera.
To avoid damage, do not load this camera in a place subject to vibration,
humidity or a dusty environment.
Thanks for your purchase of our product.
zIn order to make good use of this product, please read this user’s manual carefully.
zIn order to use this product correctly and safely; be familiar with all operation steps.
zPlease keep this user’s manual for future reference.
zThis document contains proprietary information, which is protected by copyright.
zAll rights are reserved. No part of this document may be photocopied reproduced or
translated to another language without the prior written consent of Yudor Co., Ltd.
zThe information contained in this document is subject to changes without notice.

4
Safety warning 3
Instructions
1. Accessories
1.1 Outdoor with heater & Blower
7
2. Camera Installation
2.1 Outdoor with heater & Blower
8
3. Camera Cable Connection
3.1 Wire specification
10
4. Infrared Remote Control 11
5. Initial Programming
5.2 Camera ID setup
12
5.3 Load Default
13
5.4 OSD MENU FUNCTION SETUP
13
5.4.1 GROUP (Auto Pan, Group Auto Cruise, Recorded Cruise)
13
5.4.1.1 AUTOPAN
14
5.4.1.2 GROUP1 ~ GROUP5
14
5.4.1.3 CRUISE
14
5.4.2 ALARM (Alarm Mode Setup)
15
5.4.3 MASK 16
5.4.4 TRACKING
18
5.4.5 PROTOCOL
18
5.4.6 ID
18
5.4.7 MISC (Manual control speed setup,Auto Flip, Default)
18
5.4.8 CAMERA
19
Table of Contents
65
31.52 I/O setting and Mail & FTP & Logs:
I/O Out1 ~ Out4 and Mode setting is reserved in option.

64
In each area can choose actions when motion alarm is triggered.
Interval: 10-60 seconds.
Based on the schedule: alarm action is based on schedule.
31.512 Record file format: AVI or JPEG
31.513 Network Dis-connected:
When the network is down, it will save 10 seconds video to local SD card.
This function is only enabled in wire connection.
31.514 IP check:
For the use of recording software, it supports the detection
of this connection. Whenever the connection is down, it
records the video to SD card. Please note video recording is
continuous to save to SD Card. To use this function, input
the IP address of the PC which is installed the specific 16CH
recording software. Enable the function of “Save to SD card”,
then click “Apply”.
31.515 Schedule
5
Camera Operation
6. Infrared remote control mode
6.1 Select Camera - By Input camera ID
20
6.2 Remote control
20
6.3 Alarm and Output On / Off
20
6.4 Preset Positions CALL, SAVE and CLEAR
21
6.5 Recall Preset Positions
21
6.6 Auto Pan Mode and Group Auto Cruise Mode
21
6.7 Speed activate Auto Tracking Function 21
7. RS-485 Control mode
7.3 Controls
22
7.4 Protecting 22
Remarks
8. Maintenance & cleaning
23
9. Troubleshooting
24
10. Specifications
25
11. Optional accessories
27
12.
Lens internal setting 29
Network
30. Network setting
49
31. IP Speed Dome Network Setting 53
31.21 Network Interface
55
31.24 Firmware Update 57
31.3 Network Setting (Static/DHCP)
57
31.35 DDNS 59
31.36 Wireless Setting 61

6
31.4 A/V Setting
61
31. 42 Video Setting 62
31.5 Event List (Motion Detect)
63
31.52 FTP & MAIL
65
Recording Software
32. 16Ch recording software menu
67
Software Specifications
81
Mobile Viewer Software
33. PDA/Smartphone Viewer
82
Appendix – Network Connecting 85
63
31.5 Event List:
31.51 Event Setting
31.511 Motion Detection & Sensitivity:
When motion is triggered, it can send the video to specific mail
address; transmit the video to remote ftp server and SD card. To
set up the motion area, click “Area 1/2/3”. Drag the area and press
“Area 1/2/3.

62
Resolution: D1 – 720X480 CIF – 320X240 QCIF – 160X120 (NTSC)
D1 – 720X576 CIF – 320X288 QCIF – 160X144 (PAL)
Quality: Best, High, Standard, Medium, Low
Video System: 60Hz (NTSC) or 50Hz (PAL)
31.422 Advanced Mode:
Bitrate Control Mode: CBR and VBR (Constant/Vary Bit Rate)
CBR: 64 Kbps~4 Mbps. The higher level set, the better video quality is.
VBR:Q=3~30. The higher level set, the better video quality is.
Video Frame Rate: 2~30FPS. FPS is Frame Rate per Second.
GOP: Group of Pictures of 1/2x 1x and 2x Default is 1x.
2x GOP is in better network environment.
1x GOP is in regular network environment.
1/2x GOP is in worse network environment.
Video System: 60Hz (NTSC) or 50Hz (PAL)
31.423 3GPP Mode: For mobile 3GPP streaming.
rtsp://<>/3g to receive the stream 2 with audio
rtsp://<>/3gx to receive the stream 2 without audio
31.43 Audio: Enable or Disable audio. Audio format is ADPCM. (Option)
7
1.1.8 Screw driver
for Securing screws
Please check if the accessories enclosed are completed. If there is any
shortage, please contact your local dealer and replace a new one.
1.1 Outdoor with heater & Blower
1
-
Accessories
1.1.7
No. 4 AAA Batteries
1.1.1 Outdoor
Speed Dome
1.1.6 Infrared
remote control
PAN/TILT
AUTO
2
5
8
0
7
4
1
9
6
3
ARK-503
1.1.5
Infrared receiver
1.1.12
User’s manual
1.1.11
Ceiling mount Bracket
1.1.10
Wall-mount Bracket
1.1.2 Control line
(In camera)
1.1.9
Securing screws
1.1.3
Power supply
1.1.4
AC Power Line

8
2.1 Outdoor with heater & Blower
2.1.1 Names of parts
A. Outer layer of base
B. Base
C. Cover
D. Wall mounted Bracket
E. Wire sheathing
F. Securing screws for wire sheathing
2.1.2 Remove protective lining.
2.1.2.1 Turn counterclockwise and carefully remove
the protective lining.
2.1.2.2 Remove securing screw for shipment (M4
*10mm) by turning counterclockwise
(As mark below).
※
Warning: Securing screw for shipment
must be properly tightened before shipping this product
。
2
-
Installation
61
Ad-hoc: Point to Point Mode.
Infrastructure: AP Mode.
31.364 Operation Mode: Auto/11b (Max. 11Mb)/11g (Max. 54Mb)
31.365 SSID: The name of Access Point that Speed Dome desire to connect.
31.366 Security: 64/128bit “WEP” and “WPA-PSK” security encryption.
More detailed information about WEP and WPA-PSK, please read
Router’s menu.
31.4 A/V SETTING:
31.41 Image Setting:
Adjust “Brightness”, “Contrast”, “Hue” and “Saturation”.
31.42 Video Setting:
31.421 Basic Mode:

60
up.
State: Idle ÆNo DDNS Service
http ://<username>.ddns.camddns.com ÆDDNS Service Active
Update Failed: The name is already registered; Network
Connection Failure; Account information may be wrong.
31.353 Third Party service: WWW.3322.ORG
Please go to the DDNS website to register and type the hostname,
username and password.
31.36 Wireless Setting (optional) IEEE 802.11 b/g wireless network.
31.361 Use RJ-45 wire to connect and setup. After setting, remove RJ45 wire.
31.362 MAC address: The MAC address of WiFi IP Speed Dome.
MAC address of wire and wireless are separated.
31.363 Mode: Ad-hoc/Infrastructure
9
2.1.2.3 Loads cover back and tightened all securing screws (Turn clockwise). Make
sure all the screws are properly tightened to keep camera waterproof
2.1.2.4 Use securing screws (accessory 1.1.9) and choice of Wall mount bracket
(accessory 1.1.10) or Ceiling mount bracket (accessory 1.1.11) install camera
in an appropriate position.
※
Do not touch lens with your hands or other objects.
※
Do not turn the lens or remove other parts. Doing so may cause damage.
※
Ceiling mount bracket(accessory 1.1.11) is for indoor use.
※
Make sure junction between dome cover
、
speed dome and bracket are air tight
sealed with Silicon glue to keep speed dome waterproof.
2.1.3 Basic setup
2.1.3.1 Please refer to 3.1 Cable Connection and 3.2 Cable specification: connect
Power line, Video cable, Infrared receiver insulation cable first, then
connect Alarm cable and RS-485 PVC instrument cable (pair type) if
needed.
2.1.3.2 Load batteries into infrared remote control and use infrared remote control to
setup camera ID and RS-485 control protocol. Please refer to
4Infrared Remote control and 5Initial Programming.
2.1.4 Install Speed Dome
Use securing screws (accessory 1.1.9) install speed dome in an appropriate
position. Before installation, make sure the structure of location you choose can
hold the weight of camera. (3.44Kg/7.58Pond)
※
Keep unconnected wires, plugs, duly insulated, or they may cause short circuit and
damage this product.

10
3.1 A-O Series
3.2 Cable specification:
Power line: 18AWG-2C
Video cable: 5C2V(5CFB) 168
Alarm cable: 22AWG-4C
Infrared receiver insulation cable: 22AWG-3C
RS-485 PVC instrument cable (pair type): 22AWG-1P
※
To insure reliable operation, above requirements must be fulfilled . To obtain better
quality, higher standard cable for long-distance transmission is recommended.
3
-
Cable Connection
59
31.35 DDNS: Supports DDNS (Dynamic DNS) service.
31.351 DynDNS: Only Dynamic service
Key-in the hostname, username and password.
Schedule update: Default is 5 minutes. Please note that
hostname will be blocked by DynDNS if schedule update is
more than once every 5 minutes to 60 minutes.
In general, schedule update in every 1,440 minutes is
recommended.
If need DynDNS service, please go to
http://www.dyndns.com to register a free account.
State: Idle ÆNo DDNS Service
http ://<username>.dyndns.com ÆDDNS Service Active
Update Failed: The name is already registered; Network
Connection Failure; Account information may be wrong.
31.352 Camddns service:
Key-in the hostname and username
Schedule update: Default is 5 minutes. It’s recommended in each 1440
minutes. If IP between schedule (Ex.1440 minutes) is changed, IP in
DDNS service will be changed too. If no IP is changed between schedule
(Ex.1440 minutes), DDNS service will enforce to change IP when time is

58
31.32 Static IP:IP Address, Subnet Mask, Gateway and DNS 0/1 manually.
31.33 DHCP:Using DHCP, it will get all the network parameters automatically
from router.
31.34 Port Assignment:
Web Page Port: Default is port 80.
RTSP Port: Default is port 554 to transmit 3GPP streaming.
RTSP Start/End Port: Default is port 5000~9000.
31.35 PPPoE(xDSL Dial-Up mode):
31.341 Select “Enabled” PPPoE
31.342 Type Username and Password for the DSL connection.
31.343 Send mail after dialed: When connect to the internet, it will send a
mail to a specific mail account. For the mail setting, please refer
to “Mail and FTP” settings.
11
7
4
1
9
6
3
ARK-503
PAN/TILT
AUTO
2
5
8
0
Clear / Camera ID Display key
Camera selected key.
90 Number key for Input camera ID /Function setting
Alarm/subtitle display on or off
Alarm/subtitle display setting
Manual focusing (FAR / NEAR)
Manual zooming (WIDE / TELE)
Call / Save / Clear preset positions
AUTO Camera direction control key and auto cruise key
Star light night vision adjustment
Recall preset position
Up / Right (OSD Menu)
Down/Left (OSD Menu)
Enter into (OSD Menu) / OK
Exit from (OSD Menu) / Skip
網路功能設定 (此機型無作用)
zMake sure to press a key after another within 5 seconds, or you will make an
invalid input.
zIn case of erroneous input, press LK to clear.
zKeys without a description are not operational in this model.
zMake sure that there is nothing between the infrared receiver and the remote
control.
zEffective distance of the remote control is 7 meters.
zIf you find that the effective distance of the remote control is shortened, replace
the batteries with new ones of the same spec.
4
-
Infrared Remote control

12
Be sure to keep the remote control within 7 meters from the receiver. All
inputs shall be made within 5 seconds, or the input mode would be cancelled
automatically. In case of erroneous input, press LK to clear or escape from the
operating mode.
5.1 Power on
After connect power for the first time, the camera will rotate once for reposition,
which is normal.
5.2 Camera ID setup.
There are two ways to setup camera ID
5.2.1 Direct setup camera ID
5.2.1.1 Input digit 3→4→5→6→3→4→5→6→3→4→5→6→3 then camera will
rotate once, indicate that camera is waiting for input camera ID
5.2.1.2 If a monitor is connecting to camera then the screen will show
KEYIN NEW ID:
-
-
-
, each digit input will show on the screen and the
meantime camera will 〝nod
〞
. After that, you can input next digit.
5.2.1.3 Camera ID is three digits totally. It can be set from 001~255.
5.2.1.4 After input all three digits, camera will rotate once and go through Default
preset point group 1 that indicate you already finished camera ID set up.
5.2.1.5 Check camera ID
5.2.1.5.1 Press LK button on the remote control, camera ID will show on the
screen.
5.2.1.5.2 Press CAM button on the remote control then input camera ID (Three
digits) check is the new camera ID show on the screen?
5.2.1.6 If any mistake made on the process of camera ID setup please repeat from
5.2.1.1 to 5.2.1.4
5.2.2 Camera ID setup from OSD MANUAL
Please refer 5.4.6 ID-SET.
5
-
Initial Programming
57
31.241 To upgrade the firmware online, click “Browse…” to select the location of
firmware. Then click “Upgrade” to the procedure. Upgrading firmware in
program as below shown.
31.242 Reboot system: Warm Start the IP Speed Dome.
31.243 Factory default: Return to factory settings. All settings by user will be
removed.
31.244 Setting Management:
Save as a File: Save settings to a text file.
New Setting File: Restore the settings from files.
31.3 Network
31.31 IP Setting: DHCP and static IP.
The settings about IP address, subnet mask, gateway and DNS, please
contact and inquire your local ISP provider

56
31.23 User Management (Administrator, PTZ and Guest).
31.23 Anonymous User Login: (YES/NO)
Yes: Allow anonymous login without password to view video.
No: Need user name & password when logo in.
Add/Set User List: Type the user name and password, then click “Add/Set”.
Click “Edit” or “Remove” to modify the user information.
31.24 System Update:
13
001 SYSTEM SETUP
GROUP-SET
→AUTOPAN
GROUP1
GROUP2
GROUP3
GROUP4
GROUP5
CRUISE
※
There is no time limit on the process of camera ID setup
Default of camera ID is
※〝
000. If you only use one camera you don’t have to setup
camera ID. You can operate all function through remote control directly.
Camera
※
ID
〝
000
〞
is only for single camera user, if you have more than one camera
you have to setup camera ID from
〝
001
〞
.
5.3 Load Default
Input digit 0→1→2→3→0→1→2→3→0→1→2→3→0 , then all setup will be
cleared and back to default.
5.4 OSD MENU FUNCTION SETUP
By holding END (for 5 seconds), OSD menu will show on the screen that indicates
camera is standing by for system setup.
To escape from the menu, you may press and release ESC repeatedly until
001 SYSTEM SETUP disappears or you may press LK to escape rapidly from the
function menu. To do so, you must wait until 001 SYSTEM SETUP disappears
before proceeding.
5.4.1GROUP
Select→GROUP
Up / Right key
Down / Left key
Enter (OSD MANU) / OK key
Escape (OSD MANU)/ Escape key
001 SYSTEM SETUP
→GROUP
ALARM
MASK
TRACKING
PROTOCOL DANA9600
ID
MISC
CAMERA

14
001 SYSTEM SETUP
GROUP-SET GROUP1
→DELAY 005
SPEED
MAX
RUNNING
ENT.
001 SYSTEM SETUP
GROUP-SET CRUISE
START-RECORD →ENT.
RUNNING
ENT.
001 SYSTEM SETUP
GROUP-SET AUTOPAN
START-POINT →ENT.
END-POINT
ENT.
SPEED
X2
RUNNING
ENT.
5.4.1.1 AUTO PAN
Select →AUTO PAN
START-POINT: PAN LIMIT TO THE LEFT
END-POINT : PAN LIMIT TO THE RIGHT
AUTO PAN SPEED SETUP 2.5 ゚~ 60 ゚/s
MIN, X1, X2, X3, X4,
MAX
2.5 ゚5゚10 ゚20 ゚40゚60 ゚
RUNNING: Running Auto pan
5.4.1.2 GROUP1~ 5 Dwell time and cruise speed of group auto cruise set up
Enter into group setup
Choose group from group1~5
DELAY-SET is to setup dwell time of each preset
position 005 ~ 255 seconds
005 ~ 255 stand for 005 ~ 255 seconds
SPEED-SET is to set the cruise speed of group auto
cruise from 2.5 ゚/sec ~ 320 ゚/sec
MIN,
X1,
X2, X3, X4, X5, X6, X7, MAX
2.5 ゚5゚10゚20゚40 ゚60゚80 ゚160 ゚320 ゚
RUNNING: Running group auto cruise
5.4.1.3 CRUISE
Select →CRUISE ( Recorded Cruise)
1. Select START-RECORD
2. Press END and prepare to record
3. Adjust camera (including direction and zoom)
to the spot you want to start recording.
※
When recording, zoom cannot be adjusted.
55
31.2 Configuration:
31.21 Control Interface:
31.22 System information:
31.220 MAC Address: MAC of Ethernet
31.221 Server Name: Maximum 18 characters.
31.222 Select language:
31.223 OSD Setting: Display the timer
31.224 Server time setting: Use NTP or Input Date & Time manually.

54
31.11 : Administration page ; : Snapshot ; : Live Video
31.12 : (Option Reserved)
31.13 Online visitors: How many people is connecting to this IP Dome.
31.14 Info Bar: Show system date, time, video resolution and FPS
31.15 Double-click the video to change to full screen mode. Press “Esc” or
double-click the video again to return normal mode.
31.16 Right-Click the mouse on the video, it will show a pop-up menu.
Snapshot: Save a jpg picture
Record Start: Record the video in the local PC.
Mute: Turn of the audio. Click again to turn on it.
Full Screen: Full-screen mode.
Note: When record Start, system will ask you where to save the video. If
need stop recording, right-click the mouse again and select “Record
Stop”. The video format is AVI. Microsoft Media Player or some other
MPEG4 media compatible players can play the recorded file.
31.17 PTZ Control Panel: (Relay Out 1~4 are reserved.)
It needs the same settings with Camera.
SeeP.14ProtocolandP.15IDsettings.
PTZ Sensitivity
Add or remove
Preset Point
15
001 SYSTEM SETUP
CRUISE RECORDING
D: 127 T: 655
001 SYSTEM SETUP
GROUP-SET CRUISE
START-RECORD
ENT.
RUNNING
→ENT.
001 SYSTEM SETUP
ALARM
→ALARM1 NO
ALARM2 NO
ALARM3 NO
ALARM4 NO
MODE OFF
DELAY
005
OUTPUT
OFF
5.4.1.3.1 RECORDING
1. Press END to start recording
2. Use direction key to control camera to the spot
need to be monitoring
3. When finish recording, press END to save
※
When recording only camera direction control key and END
、
ESC
、
LK key can
function
。
※〝
D: 127
〞,〝
T: 655
〞
Show on monitor indicate data and time left to be recorded
5.4.1.3.2 RUNNING CRUISE (PRECORDED CRUISE)
Select→RUNNING
1. Press END twice to start cruise
2. Press any key to stop
※
When exit OSD MENU
,
press AUTO
→
6to start cruise.
5.4.2 ALARM
Select→ALARM
ALARM1~4 alarm trigger mode setup
NO
alarm triggered when short circuit
NC
alarm triggered when broken circuit
OFF no alarm will be triggered
MODE:set alarm mode:
SAT When alarm 1 triggered camera will automatically goes to preset position
1,activate auto tracking function and output switch “ON” until finish
delay time count down.
ON When alarm 1 triggered camera will automatically goes to preset position
1,activate output switch “ON” until finish delay time count down.
OFF alarm output goes off

16
001 SYSTEM SETUP
GROUP
ALARM
MASK
→NO .1
TRACKING
PROTOCOL DANA9600
ID
MISC
CAMERA
001 SYSTEM SETUP
MASK NO.1
RELOAD
→ENT.
CLEAR
ENT.
SAVE ENT.
DELAY:Delay time setup, after finish delay time count down , camera will back to
original status before alarm triggered.
BY SAT
Delay time will automatically go with 5.4.4 TRACKING delay time
setup。(Can be set only whenALARM MODE set on SAT)
005 Delay time can be set from 005 ~ 255 秒。(Can be set only when
ALARM MODE set on “ON” or ”OFF”)
OUTPUT:switch of small electric facility (Max load 300mA),
ON
OFF
(Only when MODE is setup to OFF, OUTPUT will show on the OSD MENU)
※ Output switch goes off by press LK key during delay time count down.
Auto tracking functions keep working.
※ Press LK key to know the current status of alarm.
Twinkling ” AL001”: ALARM1 keeping triggered.
” AL001”: ALARM1was triggered, but already goes off.
: No alarm been triggered.
5.4.3 MASK
Only M / T-Series provide Function
Only 4 blocks of privacy masking can be set in a
single frame of monitor.
Maximum 24 blocks of privacy masking can be set。
Choose one block from No.1 ~ No. 24,
Press END to enter.
5.4.3.1 RELOAD, CLEAR, SETUP BLOCK OF MASKING
RELOAD Load masking or reload previous setup。
CLEAR Clear block of masking
SAVE Setup position and size of masking
53
31. Live Video
Start a IE browser, type the IP address of the IP camera in the address field. It will show
the following dialogue box. Type the user name and password. The default user
name and password are “admin” and “admin”.
31.1 The following GUI shows.

52
30.53 IE ÆTools ÆInternet Options… ÆSecurity Tab ÆCustom Level… ÆInitialize
and script ActiveX controls not marked as safe ÆSelect “Enable” or Prompt.
17
001 SYSTEM SETUP
MASK NO.1MODIFY
H-POS. →08
V-POS.
08
H-SIZE
08
V-SIZE
08
001 SYSTEM SETUP
TRACKING
DELAY
→005
MODE
SAT2
RUNNING ENT.
5.4.3.2 SETUP POSITIONAND SIZE OF MASKING
Enter SAVE, Use UP、DN key to adjust position
and size of masking. Exit SAVE to finish setup.
H-POS. Horizontal position adjustment
V-POS. Vertical position adjustment
H-SIZE
Horizontal size adjustment
V-SIZE
Vertical size adjustment
5.4.4 AUTO TRACKING
Only T-Series provide Auto Tracking Function
DELAY Delay time setup, can setup from 005 ~ 255Secs
MODE Tracking mode setup
SAT1 When the object been tracking make no move or out of range, start to count
down delay time, when finish count down, camera automatically goes back to
previous activate position to stand by.
SAT2 When activate Auto tracking function, start to count down delay time, when
finish count down, camera automatically goes back to previous activate
position to stand by.
RUNNING Activate Auto tracking function (Ätwinkles on upper-left corner of
monitor after activate.
※
Auto tracking function may be influenced by dark environments or lights.

18
001 SYSTEM SETUP
ID
OLD- ID: 0
0
0
NEW- ID:
-
-
-
↑
KEYIN NUM<000-255>
001 SYSTEM SETUP
GROUP
ALARM
MASK
TRACKING
PROTOCOL →DANA9600
ID
MISC
CAMERA
001 SYSTEM SETUP
MISC
→SPEED MAX
AUTO-FLIP ON
DEFAULT
ENT.
5.4.5 PROTOCOL
Select→PROTOCOL (For RS-485 systems)
DYNA9600 (DYNACOLOR Rate 9600)
ELITAR2400
(ELITAR Rate 2400)
CHIPER9600
(CHIPER Rate 9600)
LILIN9600
(LILIN Rate 9600)
PELCOD2400 (PELCO-D Rate 2400)
PELCOP4800 (PELCO-P Rate 4800)
PELCOP9600 (PELCO-P Rate 9600)
Please choose protocol that match to your control device (DVR or KEYPAD).
※
Protocol can not be set through RS-485
※
The only way to set protocol is through Infrared remote control
5.4.6 ID
Select→ID
Setup new camera ID (three digits 001~255) then
press END to store.
※
Camera ID cannot be setup through RS-485.
※
Only way to setup camera ID is through infrared remote control.
5.4.7 MISC (Manual control speed setup, Auto flip, Default)
5.4.7.1 SPEED
Select→SPEED
SPEED Manual control speed setup
From 2.5 ゚/sec to 160 ゚/sec
MIN, X1, X2, X3, X4, X5, X6, MAX
2.5 ゚5゚10 ゚20 ゚40゚60゚80 ゚160 ゚
Rotation speed can be variable by controlling a joystick
※
51
30.42 Change color quality to highest (32bit).
30.5 Install ActiveX control:
30.51 For the first time to view the camera video via IE, program will ask to install the
ActiveX component as below message.
30.52 If the installation failed, please check the security setting for the IE browser.
IE ÆTools ÆInternet Options… ÆSecurity Tab ÆCustom Level… Æ
Security Settings ÆDownload unsigned ActiveX controlsÆSelect “Enable”
or Prompt.

50
30.32 The GUI of the IP Installer:
30.33 IP Installer searches all the IP cameras which connect to the LAN and
lists on the left side of the IP Installer. Just click the “Search Device” to
re-search again.
30.34 Click one of the IP camera listed on the left
side. The network configuration of this IP
camera will show on the right side. Change
the parameter and click “Submit”. The
following dialogue box will show. Just click
“OK”. It will the change the IP and reboot the camera.
30.35 Click “Search Device” to research the IP camera. Double click the IP
camera listed on the left side. It will open an IE browser and connect to
this IP camera directly.
30.4 PC Color Quality Setting
30.41 Right-Click on the desktop. Select “ Properties”
19
001 SYSTEM SETUP
MISC
SPEED MAX
→AUTO-FLIP ON
DEFAULT
ENT.
001 SYSTEM SETUP
MISC
SPEED MAX
AUTO-FLIP ON
→DEFAULT
ENT.
001 SYSTEM SETUP
GROUP
ALARM
MASK
TRACKING
PROTOCOL DANA9600
ID
MISC
→CAMERA
5.4.7.2 AUTO-FLIP
AUTO-FLIP
Select→AUTO-FLIP
ON
OFF
5.4.7.3 DEFAULT
DEFAULT
All Setup will restore DEFAULT
Except PROTOCOLand camera ID.
5.4.8 CAMERA
Select→CAMERA
※
Please refer to Page 28 for lens internal setting.
12 Lens internal setting

20
6.1 Select Camera - By Input camera ID
6.1.1 Press CAM then CALL ID<001-255>:
-
-
-
show on the screen.
6.1.2 Input CAMERA ID (Three digits) then you can set function or control
camera.
Example: To select ID 1 camera: CAM
→0→0→1, the operation must be completed
within 5 seconds, or the Camera ID Selection mode would be cancelled
automatically. When selecting a correct Camera ID, the Camera ID will
appear on the screen; otherwise no display would appear on the screen.
※
If you do not know the Camera ID, Press LK to check the Camera ID.
6.2 Remote control
After you select the camera you want by input camera ID, then you may press the
direction key or the lens control key to control it. Press it down for operation and
release it to stop. When you operate, a status code will appear below the screen,
such as: Direction key Up½, Down¾, Left », right ¼, Tilt left up»½, Tilt right
up¼½, Tilt left down»¾, tilt right down¼¾, ZOOMST z/Z, FOCUSST f/F
IRISST adjust IRIS from MIN ~ MAX。
※
The rotation speed will change according to the zoom lens in or out.(5~60 ゚/sec).
For speed setting, please refer to MENU SPEED-SET menu setting.
※
When ½¾»¼twinkles means this direction is already to the end.
6.3 Alarms and Output On/Off
6.3.1 Press EX screen shows SET EX<1 - 5>
-
6.3.2 Press 1~4 to choose alarm 1~4 on or off.
Example: Alarm input 1: EX→1→ON / EX→1→OFF
6.3.3 Press 5 to choose output ON or OFF
Example: Output ON: EX→5→ON / Output OFF: EX→5→OFF
※
When alarm input 1 triggered, the camera will corresponding goes to preset
position1For alarm mode setting, please refer to MENU ALARM-SET.
※
Output switch can control small electric facility Max Load 300mA.
※
Functional only when alarm-set
:
MODE is OFF
6
-
Infrared Remote Control mode
49
30. Network IP Assignment
30.1 Use the software, “IP Installer” to assign the IP address. The software is in the
attached software CD.
30.2 There are two languages for the IP installer
30.21 IPInstallerCht.exe: Chinese version
30.22 IPInstallerEng.exe: English version
There are 3 kinds of IP configuration.
Static IP (Public IP or Virtual IP)
DHCP (Dynamic IP)
PPPoE (Dial-up)
30.3 Execute IP Installer
30.31 For Windows XP SP2 user, it may popup the following message box. Please click
“Unblock”.
This manual suits for next models
7
Table of contents
Other Yudor Security Camera manuals
Popular Security Camera manuals by other brands

COMPRO
COMPRO TN65 user manual

Panasonic
Panasonic WV-SFR631L installation guide

Digital Technology Art
Digital Technology Art DISCOVERY Plus series user manual

Digital Watchdog
Digital Watchdog MEGApix DWC-MF5Wi4TW user manual

Vitek
Vitek VTC-IRHCM1A Specifications

Vivotek
Vivotek FD8361 Technical specifications