Z-TRAUQ EZM-3735 User manual

EZM-3735 77x35DIN Size DigitalTimer Controller
Instruction Manual. ENG EZM-3735 01 V02 09/14
- 4 Digits Display
- Operation with One Set value
- Single Contact Output for Timing control ( )
- External Start and Pause Input
- Start, Pause, Stop via front panel
- S
-
- Adjustable internal buzzer according to Timer Stop status.
- Password protection for programming section
- Display can be adjusted to show Seconds, Minutes and Hours
ON /OFF
et value high limit boundaries
Programmable Time Bases (Milliseconds, Seconds, Minutes, Hours)
EZM- 77 x 35 DIN Size3735
Digital Timer Controller

Operating Temperature :
Max. Operating Humidity :
Altitude :
0 to 50 °C
90% Rh (non-condensing)
Up to 2000 m.
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Home applications (The unit is only for industrial applications)
1.2 General Specifications
1.Preface
EZM-3735
Some application fields which they are used are below:
Programmable Timer can be used in package machines, production and quality
control rollers, and can be adapted easily to all mechanical construction and automation
system.
Application Fields
Package machines,
Quality Control rollers,
Filling Systems,
Building Automation.
Production bands
Tool Benchs,
EZM-3735
2
Output Relay
ON/OFF Operation
1.1 Environmental Ratings
Output
Power Supply
Input
Digital Input
Start Input
230V ( %15) 50/60Hz±
Optional Supply Voltage
- 30 V
115 V ( %15) 50/60Hz,
24 V ( %15) 50/60Hz,
10
±
±
Standard
Pause Input Digital Input
a
d
a o d
can be applied

3
A visual inspection of this product for possible damage occurred during shipment is
recommended before installation. It is your responsibility to ensure that qualified mechanical
and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power off the
system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch and fuse
as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to prevent
failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble with the
unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may results in
malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During putting equipment in hole on the metal panel while mechanical installation some metal
burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the montage
of the device with inappropriate fixing clamp. Be sure that device will not fall while doing the
montage.
It is your responsibility if this equipment is used in a manner not specified in this instruction
manual.
Z-TRAUQ INC warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts
from the delivery date. This warranty is in force if duty and responsibilities which are determined
in warranty document and instruction manual performs by the customer completely.
Repairs should only be performed by trained and specialized personnel. Cut power to the
device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in
ethyl alcohol or water to clean the external plastic case.
1.3 Installation
1.4 Warranty
1.5 Maintenance
1.6 Z-TRAUQ INC.
Phone : 877-798-7287
e-mail : [email protected]

2.2 Panel Cut-Out
2. General Description
2.1 Front View and Dimensions of EZM-3735 Digital Timer
Mounting Clamp
Panel Surface
(maximum thickness 15 mm / 0.59 inch)
Front Panel
IP65 protection
NEMA 4X
4
76 mm / 3 inch 6 mm / 0.24 inch
34,5 mm / 1.36 inch
65 mm / 2.56 inch
Maximum 15 mm / 0.59 inch
110 mm / 4.33 inch (min)
71 mm / 2.79 inch
29 mm / 1.14 inch
50 mm / 1.97 inch (min)
P
hS
s
m
START
STOP
PAUSE

4. Electrical Wiring Diagram
5
1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
Before starting to remove the unit from
panel, power off the unit and the related
system.
2.3 Panel Mounting
2.4 Removing from the Panel
Relay Output
21 4 5 7 8
P/N : EZM-3735
L
N
Pause
Digital Input
230V
115V
24V 15%) 50/60Hz
(±
(±
(±
10 - 30 V
specify when ordering.
3 6
Supply Voltage Input
3
1
3
2
3
2
1
15%) 50/60Hz
15%) 50/60Hz

4.2 Device Label and Connection Diagram
4.1 Supply Voltage Input Connection of the Device
Note-1 E:xternal fuse is recommended.
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
External fuse must b e o n ( + ) connection.
230V CONNECTION DIAGRAM
6
Power Supply Connection
EXTERNAL
FUSE
(1A )
Note-1
Supply
Switch
Supply Voltage
45
LN
230V ( %15) 50/60Hz ,
115V ( %15) 50/60Hz,
24V ( %15) 50/60Hz ,
±
±
±
10 - 30 V 1.5 W
Must be determined when ordering.
16A @
250V 1HP 230 V ± 15%
50/60Hz - 1.5VA
OUTPUT
NO NCC
78
PAUSE
START

5.Front Panel Definition and Accessing to the Menus
BUTTON DEFINITIONS
LED DEFINITIONS
1. Increment Button and Start Button :
2. Decrement, Silencing Buzzer and Stop Button :
3. Pause Button :
Enter Button:
5. Output led :
6.Hour led :
7.Minute led :
8.Second led :
9.Pause led :
10.Set led :
11.Program led :
** It is used to increase the value in the Set screen and Programming mode.
** It is used for Start the Timer in the Main Screen.
** It is used to decrease the value in the Set screen and Programming mode.
** It is used to silence the buzzer.
** It is used for Stop the Timer in the Main Screen.
** While digital timer is running if Pause button is pressed or external pause input is activated,
** In the main operation screen; if this button is pressed, set value will be displayed. Value can be
changed using increment and decrement buttons. When Set button is pressed again, value is
saved and returns back to main operating screen.
** To access the programming screen; in the main operation screen, press this button for 5
seconds.
** It is used to save value in the Set screen and programming screen.
** This led indicates that Output is active.
** Indicates that device is in Hour mode.
** Indicates that device is in Minute mode.
** Indicates that device is in Second mode.
** This led indicates that Pause is active.
** Indicates that device is in Set value changing mode.
**Blinks in programming mode .
timer stops running.After that if the pause button is pressed again or external pause input is
deactivated, timer starts running again.
4.
7
6 7
3
4
1
2
3
56 7 8 7
10 119

6. Changing and Saving Timing Set Value
Main Operation Screen
When Enter button pressed ‘’S’’ led will
be active and temperature set value will
be displayed.
SET Value Screen
Timer set value can be
changed with increment and
decrement buttons.
When Enter button pressed Timing set
value can be saved.
‘’S’’ will be inactive and goes back to
main operation screen.
Main Operation Screen
Timer set value parameter (Default=01:00)
Timer set value, can be programmed between minimum Timer set value 00:01 and maximum
set limit.
8
6.1 Programming Mode Parameter List
Start Type Selection Parameter ( Default = )
Output Functions (Default = )
Time Unit and Scale Selection ( Default = 1 )Parameter
Hour / Minute
It can be adjusted from to .
Minute /Second
It can be adjusted from to .
Filter Time of Digital Inputs ( Default = 100 )
It is used for protection against the electrical contact debounce or the signal that is less than
the determined pulse time.
It can be adjusted from to msec .
Second /10 Milisecond
It can be adjusted from to .
Start / Stop buttons can be used to run or stop the timer.
External Start Input can only be used to run the timer. In order to stop the timer
the Stop button must be used.
External Start Input can be used to run or stop the timer.
if ON is selected timer runs by start and relay contact is closed. When time is
over, relay contact opens.
if OFF is selected timer runs by start. When time is over, relay contact is closed.
Start / Stop buttons can be used to run or stop the timer.
For detailed information refer to graphics.

9
Output Relay On Delay Time ( Default = 0 )
= .
It determines how long output relay will be active. Ifi t is 0000 second, then it operates
indefinitely.It can be adjusted from to minute/second. This parameter is
active only if
Buzzer Function Selection Parameter ( Default = 0 )
if this parameter is selected 0, Buzzer is inactive. Adjustable 16 different buzzer sounds.
It can be adjusted from 0 to16.
Buzzer is active during this time ( Default = )
Buzzer stays active during this time. It can be adjusted from 1 to 99 seconds When this
parameter is 1, if decrement button is pressed, is observed. In this condition
buzzer is active till buzzer Stop button is pressed.
Programming Section Access Password
.
( Default = 0 )
It is used for accessing to the programming section. It can be adjusted from 0 to 9999. If it is 0,
password will not be asked
Data Record ( Default = 1 )
Timer count value is saved to memory when power is disconnected and restored
on power up.
Timer count value is not saved to memory when power is disconnected. When
power up, Set value is shown on the screen.
Maximum Set Value Parameter ( Default = 01:00)
Maximum set value for set time value.
It can be adjusted from to .
It can be adjusted from to .
( If time value is monitored in miliseconds )
( If time value is monitored in Hours or
Minutes. )
Timer Counting Direction ( Default = )1
Timer upcount. 0 to Set value.
Timer downcount. Set value to 0.
Button Protection Parameter 0( Default = )
Button protection is not active.
Buttom protection is active for Timer Set Value.

10
6.3 Operation Graphics of ESM-3735 Digital Timer
1.1 Ifi s selected as .Start type
1.1.1 If downcount =1 and is the control diagram is shown in Figure 1.1
1.Control diagram using .Start / Stop buttons
1.1.2 If downcount =1 and is the control diagram is shown in Figure 1.2
Figure 1.1 Figure 1.2Figure 1.2
1.2 Ifi s selected as .Start type
1.2.1 If Upcount =0 and is the control diagram is shown in Figure 1.3
1.2.2 If Upcount =0 and is the control diagram is shown in Figure 1.4
Figure 1.3 Figure 1.4Figure 1.4
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Pause PausePause Pause
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Pause Pause

11
2.1 Ifi s selected as .Start type
2.1.1 If Downcount =1 and is the control diagram is shown in Figure 2.1
2.2.2 If Downcount =1 and is the control diagram is shown in Figure 2.2
Figure 2.1 Figure 2.2
1.4 Ifi s selected as .Start type
1.4.1 If Upcount =0 and is the control diagram is shown in Figure 2.3
1.4.2 If Upcount =0 and is the control diagram is shown in Figure 2.4
Figure 2.3
Figure 2.3 Figure 2.4
2.Control diagram using .Start / Stop buttons
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Pause Pause
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Power
Output
Start
Button
Start
Button
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Pause Pause

12
3.1 is selected as .
If Start type
3.1.1 If Downcount =1 and is the control diagram is shown in Figure 3.1
3.1.2 If Downcount =1 and is the control diagram is shown in Figure 3.2
Figure 3.1 Figure 3.2Figure 3.2
3.2.1 If Upcount =0 and is the control diagram is shown in Figure 3.3
3.2.2 If Upcount =0 and is the control diagram is shown in Figure 3.4
Figure 3.3 Figure 3.4Figure 3.4
3.Control diagram using External Digital Start Input.
Power
Output
Start
Input
Start
Input
Set
Screen
Set
Screen
Power
Output
Start
Input
Start
Input
Set
Screen
Set
Screen
Pause Pause
Power
Output
Start
Input
Start
Input
Set
Screen
Set
Screen
Power
Output
Start
Input
Start
Input
Set
Screen
Set
Screen
Pause Pause

13
4.1 is selected as .
If Start type
4.1.1 If Downcount =1 and is the control diagram is shown in Figure 4.1
4.1.2 If Downcount =1 and is the control diagram is shown in Figure 4.2
Figure 4.1
Figure 4.1 Figure 4.2
4.2.1 If Upcount =0 and is the control diagram is shown in Figure 4.3
4.2.2 If Upcount =0 and is the control diagram is shown in Figure 4.4
Figure 4.3 Figure 4.4
4.Control diagram using External Digital Start Input.
Power
Output
Start
Input
Start
Input
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Power
Output
Start
Input
Start
Input
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Pause Pause
Power
Output
Start
Input
Start
Input
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Power
Output
Start
Input
Start
Input
Stop
Button
Stop
Button
Set
Screen
Set
Screen
Pause Pause

14
When Enter button is pressed for 5
seconds, “P” led starts to blink. If
programming mode entering
password is different from 0,
programming mode entering screen
will be observed.
Main Operation Screen
Programming Screen
Change the value with increment
and decrement buttons.
Filter Time of Start Input
Press Enter button to access the parameter
value. Press increment button to access the
next parameter, press decrement button
to access the previous parameter.
Press OK button to save
the parameter.
Press increment button to access the
next parameter, press decrement button to
access the previous parameter
Password Entering Screen
Programming Mode
Entering Screen
Press Enter button to
access the
password entering
screen.
Password Entering Screen
Enter programming mode accessing password
with increment and decrement buttons.
Note2:If programming mode accessing password is 0, only three parameters
are accessible, and the parameter values can be changed.
Press OK button to enter
the password.
Note1: If programming
mode accessing
password is 0,
Time Unit screen
is observed instead of
programming screen
Filter Time of Start Input
If no operation is performed in programming mode for 20 seconds, device returns to main
ioperation screen automatically..
Filter Time of Start Input
6.5 Entering the Programming Mode, Changing and Saving Parameters
PAUSE PAUSE
PAUSE
PAUSE
PAUSE
PAUSE
PAUSE
PAUSE

15
Device Type
Housing & Mounting
Protection Class
Weight
Environmental Ratings
Storage / Operating Temperature
Storage / Operating Humidity
Installation
Overvoltage Category
Pollution Degree
Operating Conditions
Supply Voltage and Power
Time Accuracy
Digital Start and Pause Inputs
Control Form
Relay Output
Display
LED
Internal Buzzer
: Digital Timer
: 76mm x 34.5mm x 71mm plastic housing for panel
Mounting. Panel cut-out is 71x29mm.
: Ip65 at front, Ip20 at rear.
: Approximately 0.20 Kg.
: Standard, indoor at an altitude of less than 2000 meters
with non condensing humidity.
: -40 C to +80 C / -30 C to +80 C
: 90 % max. (Non condensing)
: Fixed installation
: II.
: II, office or workplace, non conductive pollution
: Continuous
:
: 115
: 24
: within
: Mechanical contact
: ON / OFF
: A@250V for Resistive load (Output Relay)
(Electrical life : 100.000 switching at full load)
: 14 mm Red 4 digits LED Display
: S (Green), P (Green), h (Red), m(Red),s (Red),
Output (Red)
: 83dB
: ,
o o o o
16(8)
Approvals
230V ( %15) 50/60Hz - 1.5VA
V ( %15) 50/60Hz - 1.5VA
V ( %15) 50/60Hz - 1.5VA
±
±
±
±%1 error
7. Specifications
: 10 - 30V

16
All order information of EZM-3735 Digital Timer are given in the table above. User
may form appropriate device configuration from information and codes therein
and convert it to the ordering codes. Firstly, supply voltage then other specifications
must be determined. Please fill the order code blanks according to your needs.
Please contact us, if your needs are other than the standard.
8.Ordering Information
A BC D E FG HI /
/
UV W Z/
/
0 0 0
1Relay Output (16(8) A@250 V ,at resistive Load, 1 NO+NC )
Output
E
Supply VoltageA
EZM-3735
4115V ( %15) 50/60Hz - 1.5VA±
5230V ( %15) 50/60Hz - 1.5VA±
07 07
810 - 30 V
(77x35 DIN Sizes) 0 1 01
07 Digital Input
Input
FG
07 Digital Input
Input
HI
324V ( %15) 50/60Hz - 1.5VA±
a
d
a o d
can be applied