QUICK SET UP GUIDE ZANTINGH CO DETECTOR
Telephone (reception) +31 (0)297 219 100
Telephone (service department) +31 (0)297 219 125
1. Mounting the device
•mount upright and level to a solid wall, do not lay flat (on a horizontal surface)
•do not install without its lit, always leave the device covered
•do not install in a humid environment
•do not install close to a heat source or in a place at a temperature below zero degrees
•never suspend from a condenser or any other vibrating parts
2. Connecting the hose
•make sure the sampling hose first goes upwards from the sampling point side, to prevent condensate to flow back to
the sampling point
•prevent that a water seal is formed (water trap / siphon effect)
•make sure the angled connector with compression fittings is assembled correctly, the connector should point upwards
•tighten the nuts well to fix the compression fittings (rotate 1¼ times)
•the used sampling hose should never be longer than 30 meters and not larger than Ø6mm
•make sure that the following connections are always free:
-condensate drain
-sample gas out
-by-pass out
-calibration gas in
Please read the provided operating and instruction manual
QUICK SET UP GUIDE ZANTINGH CO DETECTOR
Telephone (reception) +31 (0)297 219 100
Telephone (service department) +31 (0)297 219 125
3. Connecting the device electrically
•use the 6- and 7-pole connectors for input and output signals
4. Turning on the device
•after turning on the device, the CO detector is ready for service (metering) after 45 minutes
•adjust the needle valve on the flow meter for a correct by-pass flow (the bullet should be in the green section)
•never turn off the device
5. Functionality of the device
•the value on the display is the current measurement value of the CO gas concentration in ppm
•an error message “OLL”or “OHH” is displayed when the measurement value is out of range (<0 ppm or >100 ppm)
•the display remains blanc if there is a temperature, flow or hardware issue
•while purging (once every 60 minutes) no CO gas should be present near the device; exhaust gasses and (cigarette)
smoke have a negative effect on its functionality
•three bicolour LEDs indicate the status according to the table below
6. Maintenance
•the filter should be replaced every 6 months
•the device needs to be calibrated every 12 months; always use 100% nitrogen (N2) calibration gas
•the sensor should be replaced every 2-3 years
LED name RED GREEN (constant)
Sampling N/A
- System is measuring.
- Too little or no flow (flashes)
- Internaltemperature too low
(constantly on)
- CO concentration is too high.
(>1 minute at set value or at >70
ppm)
System failure
- Flowand temperature are
appropriate.
CO failure
- CO concentration within
programmed limits.

Popular Security Sensor manuals by other brands

Kyongbo GD16-L05A user manual

Kyongbo

Kyongbo GD16-L05A user manual

Elko iNELS Air AirKey quick start guide

Elko

Elko iNELS Air AirKey quick start guide

AWINIC AW86225 manual

AWINIC

AWINIC AW86225 manual

Dräger Flame 5000 Technical manual

Dräger

Dräger Flame 5000 Technical manual

SharpEye 40I user guide

SharpEye

SharpEye 40I user guide

LEGRAND Mosaic 0 489 22 manual

LEGRAND

LEGRAND Mosaic 0 489 22 manual

PCE Health and Fitness PCE-186 CB user manual

PCE Health and Fitness

PCE Health and Fitness PCE-186 CB user manual

Newport 818-BB-20 user guide

Newport

Newport 818-BB-20 user guide

System Sensor B224RB Installation and maintenance instructions

System Sensor

System Sensor B224RB Installation and maintenance instructions

D+H VRS 10 Original instructions

D+H

D+H VRS 10 Original instructions

Honeywell Home PROSiX Series Installation and setup guide

Honeywell Home

Honeywell Home PROSiX Series Installation and setup guide

Mustang Survival MSD901 user manual

Mustang Survival

Mustang Survival MSD901 user manual

systemax Poolnanny installation guide

systemax

systemax Poolnanny installation guide

iBeam TE-BPCIR product manual

iBeam

iBeam TE-BPCIR product manual

DSC pg9945 installation instructions

DSC

DSC pg9945 installation instructions

BST Flamonitec IFR 400 operating manual

BST

BST Flamonitec IFR 400 operating manual

koban KDP3 360 manual

koban

koban KDP3 360 manual

PNI SafeHouse HS003 user manual

PNI

PNI SafeHouse HS003 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.