QUICK SET UP GUIDE ZANTINGH CO DETECTOR
Telephone (reception) +31 (0)297 219 100
Telephone (service department) +31 (0)297 219 125
3. Connecting the device electrically
•use the 6- and 7-pole connectors for input and output signals
4. Turning on the device
•after turning on the device, the CO detector is ready for service (metering) after 45 minutes
•adjust the needle valve on the flow meter for a correct by-pass flow (the bullet should be in the green section)
•never turn off the device
5. Functionality of the device
•the value on the display is the current measurement value of the CO gas concentration in ppm
•an error message “OLL”or “OHH” is displayed when the measurement value is out of range (<0 ppm or >100 ppm)
•the display remains blanc if there is a temperature, flow or hardware issue
•while purging (once every 60 minutes) no CO gas should be present near the device; exhaust gasses and (cigarette)
smoke have a negative effect on its functionality
•three bicolour LEDs indicate the status according to the table below
6. Maintenance
•the filter should be replaced every 6 months
•the device needs to be calibrated every 12 months; always use 100% nitrogen (N2) calibration gas
•the sensor should be replaced every 2-3 years