Please read the provided operating and instruction manual
QUICK SET UP GUIDE ZANTINGH CO DETECTOR
Telephone (reception) +31 (0)297 219 100
Telephone (service department) +31 (0)297 219 125
1. Mounting the device
•mount upright and level to a solid wall, do not lay flat (on a horizontal surface)
•do not install without its lit, always leave the device covered
•do not install in a humid environment
•do not install close to a heat source or in a place at a temperature below zero degrees
•never suspend from a condenser or any other vibrating parts
2. Connecting the hose
•make sure the sampling hose first goes upwards from the sampling point side, to prevent condensate to flow back to
the sampling point
•prevent that a water seal is formed (water trap / siphon effect)
•make sure the angled connector with compression fittings is assembled correctly, the connector should point upwards
•tighten the nuts well to fix the compression fittings (rotate 1¼ times)
•the used sampling hose should never be longer than 30 meters and not larger than Ø6mm
•make sure that the following connections are always free:
-condensate drain
-sample gas out
-by-pass out
-calibration gas in
Please read the provided operating and instruction manual
QUICK SET UP GUIDE ZANTINGH CO DETECTOR
Telephone (reception) +31 (0)297 219 100
Telephone (service department) +31 (0)297 219 125
3. Connecting the device electrically
•use the 6- and 7-pole connectors for input and output signals
4. Turning on the device
•after turning on the device, the CO detector is ready for service (metering) after 45 minutes
•adjust the needle valve on the flow meter for a correct by-pass flow (the bullet should be in the green section)
•never turn off the device
5. Functionality of the device
•the value on the display is the current measurement value of the CO gas concentration in ppm
•an error message “OLL”or “OHH” is displayed when the measurement value is out of range (<0 ppm or >100 ppm)
•the display remains blanc if there is a temperature, flow or hardware issue
•while purging (once every 60 minutes) no CO gas should be present near the device; exhaust gasses and (cigarette)
smoke have a negative effect on its functionality
•three bicolour LEDs indicate the status according to the table below
6. Maintenance
•the filter should be replaced every 6 months
•the device needs to be calibrated every 12 months; always use 100% nitrogen (N2) calibration gas
•the sensor should be replaced every 2-3 years
LED name RED GREEN (constant)
Sampling N/A
- System is measuring.
- Too little or no flow (flashes)
- Internaltemperature too low
(constantly on)
- CO concentration is too high.
(>1 minute at set value or at >70
ppm)
System failure
- Flowand temperature are
appropriate.
CO failure
- CO concentration within
programmed limits.

Popular Security Sensor manuals by other brands

Velleman PEREL EMS106 user manual

Velleman

Velleman PEREL EMS106 user manual

LaserLiner CombiFinder Plus quick start guide

LaserLiner

LaserLiner CombiFinder Plus quick start guide

Pilz PSEN cs2.1n manual

Pilz

Pilz PSEN cs2.1n manual

FUHR NB649N Installation and operation instructions

FUHR

FUHR NB649N Installation and operation instructions

Berker 9420 Series operating instructions

Berker

Berker 9420 Series operating instructions

LUXOMAT PD4-M-DALI/DSI-1C-FC Installation and operating instruction

LUXOMAT

LUXOMAT PD4-M-DALI/DSI-1C-FC Installation and operating instruction

CAME R Series manual

CAME

CAME R Series manual

PCB Piezotronics TORKDISC 5302D-01A/012AC080AT Installation and operating manual

PCB Piezotronics

PCB Piezotronics TORKDISC 5302D-01A/012AC080AT Installation and operating manual

Afriso EURO-INDEX LAG-14 ER operating instructions

Afriso EURO-INDEX

Afriso EURO-INDEX LAG-14 ER operating instructions

BGE AUDIO SWlTCH BGE-7500 Installation and operating instructions

BGE

BGE AUDIO SWlTCH BGE-7500 Installation and operating instructions

Newlec EMERGENCY TWINSPOT instructions

Newlec

Newlec EMERGENCY TWINSPOT instructions

EL EL4855 installation instructions

EL

EL EL4855 installation instructions

Applied Strobe AST-14 installation instructions

Applied Strobe

Applied Strobe AST-14 installation instructions

OKM FS Future Series user manual

OKM

OKM FS Future Series user manual

Argus Security TAURUS TW-MI-S-01/916 quick start guide

Argus Security

Argus Security TAURUS TW-MI-S-01/916 quick start guide

Bosch FCP-O 500 Operation guide

Bosch

Bosch FCP-O 500 Operation guide

DoCash BIG Series user manual

DoCash

DoCash BIG Series user manual

ABB KPM KB2 quick guide

ABB

ABB KPM KB2 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.