ZEN FLOAT TENT User manual

FLOAT TENT TM
ASSEMBLY INSTRUCTIONS
VIDEO INSTRUCTIONS: zenfloatco.com/setup
Version 2.3, updated 09/31/2020.
For help with watercare maintenance go to, Zenfloatco.com/water-care/
1

IMPORTANT SAFETY INSTRUCTIONS &
WARNINGS
READ AND FOLLOW ALL INSTRUCTIONS.
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
LOAD BEARING CAPACITY &
WATER
THE FLOAT TANK IS INTENDED FOR USE BY ONE PERSON AT
A TIME. CONFIRM THAT FLOOR LOAD BEARING CAPACITIES
ARE ABLE TO SUPPORT THE FLOAT TANK WEIGHT WHEN
FILLED AND OCCUPIED. CALCULATE AT APPROXIMATELY 75
LBS (34 KG) PER SQUARE FOOT WHICH IS BASED ON A HUMAN FLOATING IN
THE TANK THAT WEIGHS UP TO 300 LBS. TOTAL FLOAT TANK WEIGHT WITH
WATER AND SALT IS APPROXIMATELY 2200 LBS (998 KG).
TEMPERATURE
ALWAYS CHECK YOUR TEMPERATURE BEFORE GETTING
INTO THE FLOAT TANK. DO NOT EVER FLOAT IF THE
TEMPERATURE IS ABOVE 96º F (36º C), OR IF IT FEELS
ABNORMALLY WARM.
2

FIRE HAZARD
KEEP ALL FLAME AND OTHER HEAT SOURCES AWAY FROM
THE FLOAT TENT, INCLUDING THE TENT FABRIC. THE
FABRIC MAY BURN OR MELT IF PLACED IN CONTACT WITH
ANY FLAME OR OTHER HEAT SOURCE.
DRUGS AND ALCOHOL USE
DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING
USE OF THE FLOAT TENT. THE USE OF DRUGS OR
ALCOHOL MAY INCREASE THE RISK OF INJURY,
UNCONSCIOUSNESS, AND POSSIBLE DROWNING.
SLIPPING AND FALLING
TO AVOID FALLING OR OTHER INJURY, USE CAUTION WHEN
ENTERING OR EXITING THE FLOAT TENT.
CHILDREN
THE FLOAT TENT SHOULD NOT BE USED BY CHILDREN
UNDER THE AGE OF 12. CLOSELY WATCH ALL CHILDREN IN
AND AROUND THE FLOAT TENT, AND NEVER LEAVE ANY
CHILD UNATTENDED INSIDE THE FLOAT TENT OR WITH
ACCESS TO THE FLOAT TENT. IT IS RECOMMENDED THAT
ALL DOORS AND WINDOWS TO THE ROOM CONTAINING
THE FLOAT TENT REMAIN LOCKED TO LIMIT ACCESS.
PREGNANCY AND OTHER HEALTH
CONCERNS
USERS WITH HIGH BLOOD PRESSURE OR WHO ARE
PREGNANT SHOULD CONSULT A PHYSICIAN BEFORE
USING THIS PRODUCT.
3

ADDITIVES AND SALT INGESTION
DO NOT ADD ADDITIVES (SUCH AS BUBBLE BATH AND BATH
SALTS) TO THE WATER IN THE FLOAT TENT, OTHER THAN
EPSOM SALT AS DIRECTED. DO NOT INGEST THE WATER IN
THE FLOAT TENT.
PROPERTY DAMAGE
DO NOT OVERFILL THE FLOAT TENT. NEVER LEAVE THE
FLOAT TENT UNATTENDED WHEN FILLING WITH WATER. BE
AWARE THAT WATER RISES AS YOU ENTER THE FLOAT
TENT. AVOID USING SHARP OBJECTS WHEN NEAR THE
FLOAT TENT AS THIS COULD PUNCTURE THE FLOAT TENT
AND CAUSE FLOODING. ALWAYS DRAIN THE FLOAT TENT
AS DIRECTED BEFORE MOVING THE FLOAT TENT TO PREVENT FLOODING.
ALWAYS DETACH THE TENT FROM THE TUB BEFORE DISASSEMBLING THE
TENT. NEVER PULL ON THE TENT TO REMOVE POLES.
SUITABLE INSURANCE
IMPROPER USE OF THIS PRODUCT MAY CREATE CERTAIN
RISKS OF DAMAGE TO PERSON AND PROPERTY,
INCLUDING WATER DAMAGE. PLEASE CONSULT WITH
YOUR INSURANCE ADVISOR FOR INFORMATION ABOUT
SUITABLE INSURANCE COVERAGE.
RISK OF ELECTRICAL SHOCK
PLUG AND INSTALL THE FLOAT TENT AT LEAST THREE
FEET FROM ALL ELECTRICAL OUTLETS AND METAL
SURFACES. DO NOT ALLOW ANY ELECTRIC APPLIANCES
WITHIN THREE FEET OF THE FLOAT TENT, AND NEVER
INTRODUCE ELECTRIC APPLIANCES INTO THE WATER, AS
THIS MAY RESULT IN SERIOUS BODILY INJURY OR DEATH.
DO NOT PERMIT ANY ELECTRIC APPLIANCE, SUCH AS A LIGHT, TELEPHONE,
RADIO, OR TELEVISION, WITHIN 5 FEET (1.5 M) OF TENT.
4

A) REPLACE ANY DAMAGED CORD IMMEDIATELY.
B) CONNECT TO A GROUNDED, GROUNDING TYPE RECEPTACLE ONLY.
C) THIS PRODUCT MAY BE PROVIDED WITH A GROUND-FAULT
CIRCUIT-INTERRUPTER (GFCI). THE GFCI MUST BE TESTED BEFORE
EACH USE. WITH THE PRODUCT OPERATING, PUSH THE TEST BUTTON
ON THE GFCI AND THE PRODUCT SHOULD NOT OPERATE. PUSH THE
RESET BUTTON ON THE GFCI AND THE PRODUCT SHOULD NOW
OPERATE NORMALLY. WHEN THE PRODUCT FAILS TO OPERATE IN THIS
MANNER, THERE IS A GROUND CURRENT FLOWING INDICATING THE
POSSIBILITY OF AN ELECTRICAL SHOCK. DISCONNECT THE POWER
UNTIL THE FAULT HAS BEEN IDENTIFIED AND CORRECTED.
D) IF THE UNIT WAS NOT PROVIDED WITH A GFCI IT MUST BE WIRED BY A
CERTIFIED ELECTRICIAN. FAILURE TO DO SO COULD RESULT IN
SERIOUS BODILY INJURY OR DEATH AND WILL VOID ALL WARRANTY
COVERAGE.
ADDITIONAL WARNINGS
★DANGER – Risk of Injury. The Water Pump and UV Water Filter provided should
always be turned off before you enter the Tent. Failure to do so could result in
serious bodily injury or death.
★CAUTION: To avoid damage to the Water Pump it must never be operated
unless the Tent is filled with water.
★NOTE: Please examine equipment before use. Notify Zen at the customer
service address listed on this manual for any damaged or missing parts at the
time of purchase. Verify that the equipment components represent the model that
you had intended to purchase.
5

PACKAGE CONTENTS
6 x SHORT POLES - 14”
8 x MEDIUM POLES - 34”
6 x LONG POLES - 42”
2 x T-CONNECTOR
3 x METAL DOOR POLES
5 x PLASTIC DOOR
POLES
6

1 x TOP CONNECTOR
*Pre-assembled w/ Top Connector
Nut & Bolt
2 x RIGHT CORNER
2 x LEFT CONNECTOR
1 x VINYL TENT COVER
1 x VINYL TUB
1 x DRIP MAT
2 x HEATING PADS
4 x VENT CAPS
1 x TEMP CONTROLLER
*Pre-plugged w/ Grounding Probe
7

1 x WATER PUMP &
1 x UV WATER FILTER
*Pre-connected
1 x FILTER BAG
*Additionals incl. w/ Float Ready
Package
2 x FILTER HOSE, 1 x T &
1 x 90 DEGREE
FITTINGS, & 1 x PUMP
MANIFOLD
1 x STRUCTURE STRAP
1 x WALL GFCI
*120V models only
1 x GROUND PROBE
*Pre-plugged to Temperature
Controller
1 x HYDROMETER
1 x INLINE CARBON
WATER FILTER
1 x WATER TEST STRIPS
8

1. CHOOSE PROPER PLACEMENT
★Choose a preferred location that will stay between 70° and 90° Fahrenheit (21° to
32° Celsius).
★Allow at least 1 ft (30 cm) of space between the Float Tent and the room’s walls
to allow for maintenance and cleaning.
TIP: If your tent is located in a room with a tile or concrete floor, we strongly
recommend that you add insulation between your heating pads and floor.
9

2. ASSEMBLE WATER TUB
To verify there were no punctures in transit, move the tub to an outdoor area and fill up
to ten inches. If you have any leaks contact us immediately.
NOTE: Poles are threaded through sleeves on the water tub.
NOTE: Make sure the open end of corner pieces point toward the center of the Float
Tent. Also, don’t forget to connect center pole bases with the structure strap.
10

3. ASSEMBLE PYRAMID FRAME
Assemble the frame onto the existing tub, then make the final connection at the tip of
the pyramid last.
11

4. PLACE LINER AND TANK IN PLACE
IMPORTANT
VERIFY THE PADS ARE THE CORRECT SIDE UP!
★They will have markings on each pad to verify which side is up.
★Plug in the pads temporarily to verify they werenít damaged in transit. The pads
will heat almost too hot to touch.
BURNS
USE HEATING PADS ONLY AS DIRECTED. CONFIRM THAT
THE HEATING ELEMENT IN THE HEATING PAD IS FACING
UPWARD. WHILE THE HEATING PAD IS ACTIVATED, DO NOT
LEAVE IN CONTACT WITH ANY OBJECT OTHER THAN THE WATERPROOF
LINER AS DIRECTED, AND AVOID DIRECT CONTACT OF SKIN WITH THE
HEATING PAD.
12

NOTE: Heating Pads will overlap in the center.
With heating pads properly placed, cover with waterproof liner and place the tub
directly over pads. The liner should stick out evenly on three sides, but there should be
excess on the side where the tent door will face. With the liner in place, the tub will sit
exactly over them. To avoid damage, make sure tub legs are not on top of pads.
13

5. INSTALL FILTRATION SYSTEM
A. Pump Manifold
B. Water Pump & UV Water Filter
C. Filter Bag (at front of tank)
D. T Fitting
E. 90 Degree Fitting
1. Start by setting the Water Pump and UV Water Filter (B) in place.
2. Once your Water Pump and UV Water Filter (B) are in the right position, screw
the Pump Manifold (A) on top of it. This would be the time to make sure it aligns
well with your filter bag (C) in place. Adjustment may be necessary.
3. Once A,B, and C are in place it is time to add the rest of the filtration line. The
hoses should connect together with some force. Be sure to use the T Fitting (D)
in the middle, followed by the 90 Degree Fitting (E) at the end.
14

6. FILL TANK WITH EPSOM SALT
1. Install Inline Carbon Water Filter to the hose you are using to fill your tent.
p
NOTE: To make sure no carbon from your filter enters your tank, run about 5 gallons of
water through the filter into a drain, or until water runs clear.
2. After adding 2 to 3 inches (5 to 7.5 cm) of water, start smoothing out creases on
the tub floor. Once smooth, continue to fill the tank with 5 inches (13cm) of water.
Add 100 lbs (45 kg) of salt at a time, mixing in fully as you go.
NOTE: If you bought your salt from zen float co., we provide 800 lbs (363 kg) of salt
per pallet and you will need all of it for the first fill of your tent.
3. Agitate water and salt by stirring and mixing. It may be easiest to stand in the
water and mix it around with your feet.
15

4. Once 800 lbs (363 Kg) of salt is added, fill until the water level reaches 10 inches
(25.5 cm).
16

7. PLUG - IN AND VERIFY SAFETY
Plug the Temperature Controller, the Water Pump and the UV Pump into the GFCI
outlet. For safety, the tank water should be electrically grounded due to a possible
induced current from the heaters. Make sure the Grounding Probe is plugged in and
submerged at all times.
Plug everything with the tank through the GFCI provided (120V versions only) or one of
your choosing. GFCI’s cut the power if the electricity ever comes in contact with the
water. If an accident were to happen, they will save your life! Test them once a month
with the test button. If it powers off they are good. Be sure your GFCI is at least plug
height, not lower.
IMPORTANT
EVERYTHING MUST PLUG INTO A
GFCI OR RCD
NEVER PLUG ANYTHING NEAR YOUR TANK INTO THE WALL
DIRECTLY. EVERYTHING SHOULD PLUG INTO A GFCI
DEVICE. FAILURE TO DO SO MAY RESULT IN SERIOUS
INJURY OR DEATH.
17

8. TURN ON AND VERIFY SETTINGS
1. Plug the two heating pads into the Temperature Controller.
2. Plug the UV Filter in.
The first thing you will notice is a slight glow from the UV filter. The Temperature will
now display a temperature detected by the attached temperature sensor.
3. Securely place the sensor in the water toward the bottom of the tank to allow the
Temperature Controller to auto-regulate water temperature through heating pads.
4. Set Temperature Controller to: 93.5º F (34º C)
Anticipate the temperature rising approximately 1º F (1/2º C), per hour.
To set the temperature controller,
single click bottom button to set the
temperature, and use the top and
middle buttons to adjust
To change degrees to Celsius hold
the top and middle (up and down)
buttons simultaneously for three
seconds.
You should now see the heating indicator light turn on and within minutes be able to
feel warmth coming up through the pads in your tank.
18

9. INSTALL TENT COVER
Float Tent Cover will have a tight fit. Work each corner one at a time sliding them down
a few inches each time around.
19

10. INSTALL TENT DOOR
Door poles go in sleeves located around the perimeter of both the tent wall and tent
door flap. Each pole will have a number on it. Insert poles in their corresponding pole
sleeves as illustrated below.
TIP: The poles tend to shift when using the tank regularly. You can use a small piece
(½”x1”) of double-sided foam tape to secure them in place if you prefer.
20
Other manuals for FLOAT TENT
1
Table of contents
Other ZEN Hot Tub manuals
Popular Hot Tub manuals by other brands

Iberspa
Iberspa Hotel Spa manual

Aquatic
Aquatic HOTSOAK 84 AI7236SVHS Specification sheet

HOT TUBS
HOT TUBS Muskoka user manual

treesse
treesse minipool Quarz Operating and maintenance manual

Whitehall
Whitehall E-27-S Instructions for operation and care

VANITY PLANET
VANITY PLANET ULTIMATE SKIN SPA Instruction manuals

LMS
LMS AM-628TS Pre-Delivery Guide

American Standard
American Standard CADENZA ELITE 6060E SERIES installation instructions

Image
Image renew 455 831.104550 user manual

infinite spa
infinite spa CHAMPION 6 places operating manual

Polhus
Polhus Polar Tub Royal Assembly

Master Spas
Master Spas INT EVO COMPACT owner's manual