Zenitel Vingtor Stentofon FCDC1 Instruction sheet

Configuration Manual
Flowire Converter
FCDC1 / FCDC2
A100K11422
TECHNICAL MANUAL

2A100K11422
Flowire Converter Conguration Manual
About this Document
Document Scope
This document provides a detailed guide to the system setup and conguration of the FCDC1
and FCDC2 Flowire Converter in creating IP networks using conventional telecom star-wired
infrastructure (2-wire).
Relevant Products
Product Description Item Name Item No.
Flowire Converter, 24-48V DC FCDC1 1008080110
Flowire Converter for Ex, 24-48V DC FCDC2 1008080210
XP PSU, 48V DC, 120W Flowire XP 120 2990101120
XP PSU, 48V DC, 240W Flowire XP 240 2990101240
Powerbox PSU, 24V DC, 120W Flowire EX 120 2990102120
Powerbox PSU, 24V DC, 250W Flowire EX 250 2990102240
Turbine Extended Ex IP Intercom TFIX-1 1008123010
Turbine Extended Ex IP Intercom TFIX-2 1008123020
Turbine Extended Ex IP Intercom TFIX-3 1008123030
Turbine Extended Ex IP Intercom TFIX-4 1008123040
Exigo Access Panel Ex EAPFX-1 1023221511
Exigo Access Panel Ex EAPFX-6 1023221516
Publication Log
Ver. Date Author Status Comments
1 5.7.2013 HL/HKL Published
2.1 13.4.2016 HKL Published FCDC1 restrictions
3 2.5.2017 HKL Published New GUI, IGMP, CCo
3.2 9.5.2018 HKL Published Ex & industrial connection
3.3 17.10.2018 HKL Published Ex cabling
Related Documentation
For further information, refer to the following documentation:
Doc. number Documentation
A100K11706 Flowire Guidelines for Exigo
A100K11285 Flowire Getting Started
A100K11611 Replacing Flowire Converter
A100K11379 Autocad Dimension Drawing
A100K11499 Exigo & Turbine Ex Installation & Maintenance
Acronyms
Acronym Meaning
FCDC Flowire Converter Direct Current
Flowire Star
Conguration
A star conguration consisting of two or more Flowire devices, with a link to each other,
and one PSU.
NMK Network Management Key
PLC Power Line Communication. This is the basis of the Flowire technology for transporting
both power and signal on power cables or any other cable with at least two conductors.
PSU Power Supply Unit

3
Flowire Converter Conguration Manual
A100K11422
Contents
1 Product Description ............................................................................................................4
1.1 General Description .......................................................................................................4
1.2 Areas of Application .......................................................................................................5
1.2.1 Retrotting Older Intercom & Telephone Systems ......................................................5
1.2.2 Remote IP Intercom Locations In New Buildings ........................................................5
2 Upgrading Conventional Star-Wired Infrastructure .........................................................6
2.1 The Conventional System .............................................................................................6
2.2 Power on Conventional Infrastructure ...........................................................................7
2.3 Precaution & Limitations ................................................................................................7
2.4 Recommendations .........................................................................................................7
2.5 System Conguration with Central Powering of Remote Intercoms ..............................8
2.6 System Conguration with Local Powering of Remote Intercoms .................................9
2.7 System Conguration with Industrial & Ex Devices .....................................................10
3 Connections & Indications ............................................................................................... 11
3.1 Flowire Connection ...................................................................................................... 11
3.2 Ethernet Connection .................................................................................................... 11
3.3 Indicator LEDs ............................................................................................................. 11
3.4 Password Reset Button ............................................................................................... 11
4 Mounting & Recommendations........................................................................................12
4.1 Mounting the Flowire Converter ..................................................................................12
4.2 Power Requirements ...................................................................................................13
5 Troubleshooting ................................................................................................................14
5.1 Power for Stable Connection at Remote Site ..............................................................14
5.2 Cables & Bandwidth ....................................................................................................14
5.3 Collecting Trace Logs ..................................................................................................14
A: Power Consumption & Distances for Typical Cables ....................................................16
B: AdvancedConguration...................................................................................................17
B.1 Setting a Static IP Address ..........................................................................................17
B.2 Disabling DHCP ..........................................................................................................18
B.3 Network Management Key (NMK) Conguration ........................................................19
2.1 IGMP Settings..............................................................................................................20
2.1.1 IGMP Querier ............................................................................................................20
2.1.2 IGMPv2 Compatability ..............................................................................................20
2.2 CCo Settings ...............................................................................................................21
C: Software Upgrade..............................................................................................................22
C.1 Upgrading via VS-IMT on PC ......................................................................................22
C.2 Upgrade via Web Interface on Flowire Device ............................................................25
C.2.1 TFTP Server Setup ...................................................................................................25
C.2.2 Flowire Device Web Interface ...................................................................................25
Figures
Figure 1 FCDC1 Flowire Converter .......................................................................................................................... 4
Figure 2 FCDC1 and FCDC2 .................................................................................................................................... 4
Figure 3 Conventional star-wired infrastructure ........................................................................................................ 6
Figure 4 Conventional star infrastructure with multi-pair cables and junction boxes ................................................ 6
Figure 5 Flowire Upgraded conguration with central power distribution. ............................................................... 8
Figure 6 Conventional analog/digital system conguration....................................................................................... 9
Figure 7 Flowire Upgraded conguration with local power at remote locations. ...................................................... 9
Figure 8 Cabling in Ex & Industrial Zones............................................................................................................... 10
Figure 9 Flowire Converter Dimensions.................................................................................................................. 12
Figure 10 DIN Mounting Clips ................................................................................................................................... 12
Figure 11 IGMP Settings ........................................................................................................................................... 20
Figure 12 Congured PLC Role - CCo, Not CCo, Auto ............................................................................................ 21

4A100K11422
Flowire Converter Conguration Manual
1 Product Description
1.1 General Description
The Flowire Converter enables Ethernet to run on the same two wires as power, providing simpler
cabling and opening up for longer cable hauls. The Flowire converter is also capable of powering the
Ethernet devices (Vingtor-Stentofon IP intercom stations) attached to it via spare pairs.
1
Flowire/Power Ports
Ground Connection
Sta tus I ndicators1
2
3
2 3 45
Password Reset Button4
Ethernet Port5
Figure 1 FCDC1 Flowire Converter
There are two models of the Flowire Converter:
Model Description
FCDC1 24-48 VDC Flowire Converter with power-forwarding (PoE, type
2). Forwards 48V from the power supply to the spare pairs of the
Ethernet port (not true PoE).
FCDC2 Non-PoE 24-48 VDC Flowire Converter for use with central equipment
rack and Ex devices. Does not forward 48V to the spare pairs of the
Ethernet port.
Figure 2 FCDC1 and FCDC2
LIt is recommended to use FCDC1 only when you need to power the connected device
via the spare pairs of the Ethernet port. In all other situations, use the FCDC2.

5
Flowire Converter Conguration Manual
A100K11422
1.2 Areas of Application
The main areas of application for the Flowire Converter are:
● Retrotting older communication systems
● Providing Ethernet connectivity to remote locations in buildings
1.2.1 RetrottingOlderIntercom&TelephoneSystems
● Analog and digital intercom systems
● Analog and digital telephone systems
The above solutions typically use a conventional star-wired telecom infrastructure with 0.5 mm2 (20
AWG) single-pair twisted cables.
1.2.2 Remote IP Intercom Locations In New Buildings
In some new building projects, it is a challenge to provide Ethernet connectivity to remote locations
(beyond 100 meters from the main equipment room) for critical communication.
By implementing Flowire Converters, it is possible to upgrade these systems with IP products without
costly and time consuming re-cabling of CAT or ber cables.
This manual suits for next models
2
Table of contents
Other Zenitel Media Converter manuals
Popular Media Converter manuals by other brands

H&B
H&B TX-100 Installation and instruction manual

Bolin Technology
Bolin Technology D Series user manual

IFM Electronic
IFM Electronic Efector 400 RN30 Series Device manual

GRASS VALLEY
GRASS VALLEY KUDOSPRO ULC2000 user manual

Linear Technology
Linear Technology DC1523A Demo Manual

Lika
Lika ROTAPULS I28 Series quick start guide

Weidmuller
Weidmuller IE-MC-VL Series Hardware installation guide

Optical Systems Design
Optical Systems Design OSD2139 Series Operator's manual

Tema Telecomunicazioni
Tema Telecomunicazioni AD615/S product manual

KTI Networks
KTI Networks KGC-352 Series installation guide

Gira
Gira 0588 Series operating instructions

Lika
Lika SFA-5000-FD user guide