Zero Breeze MARK 2 Series User manual

MARK 2
Mark 2/Mark 2 Plus/Mark 2 PE
User Manual
www.zerobreeze.com
V1.0
SERIES
Warning: Before using this product, please read this manual carefully and keep it for future reference.
The design and specifications are subject to change without prior notice for product improvement.
Consult with your dealer or manufacturer for details.
Video Tutorial
Visit our official website to watch a video tutorial at www.zerobreeze.com
Model: Z20
Rated Voltage : 24V DC
Cooling Capacity : 650W
Cooling Rated Input : 240W
Refrigerant : R134A
Sound Level : 52dB (A)
Climate Type: T1
Moisture Protection: IPX4
Carton Size: 23.6"Lx12.6"H/60x32x51cm
Net Weight: 16.5Lbs

•This air-conditioning unit is a sealed unit containing a fluorinated gas. For information on specific gas types and
quantities, see the relevant label on the device. Mark2 does not support users adding refrigerant themselves.
•Maintenance or repair of this equipment must be performed by a certified technician.
•Product recycling must be performed in accordance with local regulations.
Note
•All pictures in this manual are for illustration only. Your air conditioner may be slightly different depending on your model.
Notes on fluorinated gases
SAFETY PRECAUTIONS
CAUTION
Read This Manual
Inside you’ll find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive
care on your part can save you a great deal of time and money
as well as extend the life of your air conditioner. You’ll find many answers to common problems in the troubleshooting
tips - you should be able to fix most of them quickly before calling service. These instructions may not cover every
possible condition of use, so common sense and attention to safety is required when installing, operating and main-
taining this product.
•Installation must be performed according to the installation instructions. Improper installation can cause water
leakage, electrical shock, or fire.
•Use only the included accessories and parts, and specified tools for the installation. Using non-standard parts can
cause water leakage, electrical shock, fire, and injury or property damage.
•Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped
with a three-prong grounding plug to protect against shock. Voltage information can be found on the side of the unit,
behind the grille.
•Install the unit on a flat, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
•The unit must be kept free from obstruction to ensure proper functioning and to mitigate safety hazards.
•DO NOT modify the length of the power cord or use an extension cord to power the unit. DO NOT share a single outlet
with other electrical appliances. Improper power supply can cause fire or electrical shock.
•DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Exposure to water can cause
electrical components to short circuit.
•DO NOT install the unit in a location that may be exposed to combustible gas, as this could cause fire.
•DO NOT operate a unit that has been dropped or damaged.
•Only use the included accessories and specified parts for installation. Using nonstandard parts can cause water
leakage, electrical shock, fire, and injury or property damage.
•DO NOT allow children to play with the air conditioner. Children must always be supervised around the unit.
•If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immedi
ately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a
technician or customer service for assistance.
•In a thunderstorm, the unit should be turned off to avoid damage to the machine due to lightning
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabil-
ities, unless they have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
•If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
•Prior to cleaning or other maintenance, the appliance must be disconnected from electricity.
•Do not install the appliance in a location that may be exposed to combustible gas. If combustible gas accumulates
around the unit, it may cause fire.
•Do not run the power cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not
route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
•To reduce the risk of fire or electric shock, do not use this air conditioner with any solid-state speed control device.
•The appliance shall be installed in accordance with national wiring regulations.
•Contact the authorized service technician for repair or maintenance of this unit.
•Do not mix old and new batteries.
•Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh, etc.) batteries.
•Contact the authorized service technician for repair or maintenance of this unit.
•The air conditioner is not intended for use by young children or anyoneunable to operate it
independently.
•When using this unit in the presence of children they should always be supervised.
•If the power cord needs to be replaced, please contact our consumer service to find an autho
rized technician.
•Electrical installation must be performed in accordance to national regulation standards by
qualified personnel only.
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
CAUTION: This symbol indicates the possibility of injury or damage to property
WARNING: This symbol indicates the possibility of death or serious injury.
01 02

03 04
The Mark2 is equipped with a new 24V high-performance compressor, and the outlet temperature can be lower than
the ambient temperature of 28℉in 10 minutes. The new dual-hose exhaust system improves space cooling speed by
40% over the first generation. The classic handle design makes it easy to move. Using Mark2's special battery can
achieve a maximum continuous working time of about 5 hours.
GETTING TO KNOW THE MARK 2
Power Button
•When power on, press once to turn on, then press to turn off.
•After the unit is stopped, the compressor cannot be restarted for one minute. This is to protect the equipment.
STRONG mode
Press the "STRONG" mode button, the
indicator lights up, and the other mode
lights go out.
The air conditioner enters the STRONG
mode and works at full load. The air
conditioner status indicator is blue.
SLEEP mode
Press the SLEEP mode button, the
indicator lights up, and the other mode
lights go out.
The air conditioner enters SLEEP mode
and works at low load. The air
conditioner status indicator is blue.
LIGHT button
Press the LIGHT button, the indicator
light is on, the front light is on, and
press it again, the light is off.
When the air conditioner is powered on,
there is no need to turn on the air
conditioner, and the lighting can be
turned on or off.
Alternative function Long press for 3
seconds, air outlet temperature display
switch between Fahrenheit and Celsius.
Unplug the plastic sheet and use the
remote control.
CONTROL PANEL&REMOTE CONTROL PANEL
1.Control Panel
2.Outlet air direction adjustment
3.Outlet air temperature display
4.Air filter
5.LED lights
6.Status light
7.Exhaust air outlet
8.Exhaust air inlet
9.Power input
10.Drain
Design and Compliance Notes
* The batteries shown in this manual need to be purchased separately, please refer to the zerobreeze.com for more details.
** The cooling speed and maximum working time are measured under the experimental environment and are for reference only.
*** Mark2 already contains a set of intake and exhaust hoses. If you need a longer hose, learn more from zerobreeze.com.
LIGHT ON/OFF
SPEED
FAN
SLEEP COOL STRONG
❆
+Button
Increase blowing speed.
*Alternative function
FAN mode
Press the FAN button, the FAN indicator is
on, and the other modes are off.
When the air conditioner enters in FAN
mode, the compressor and exhaust fan
will be turned off after 5 seconds, and the
air conditioner status indicator will
change from blue to red.
When the FAN mode is switched to
another mode, the compressor will have a
protection delay of 1 minute before it
starts to work.
❆
❆
❆
COOL mode
The default cooling mode, when the power
supply voltage is lower than 19V, the air
conditioner will stop working automatically.
Press and holdthe cooling mode control
button(hold for 2 seconds), Mark 2 will
enter the car mode (tail indicator light will
bepurple).In this mode, when the power
supply voltage is lower than 22V, the air
conditioner will automatically power off to
prevent the car battery from running out.
When the cooling mode button is pressed
and hold for 2 secondsagain, it switches to
the default cooling mode.
This setting has a memory function, that is,
after unplugging the power supply, when
powered on next timeitmaintainsthe
previous setting mode.
❆
❆
❆
❆
-Button
Decrease blowing speed
*Alternative function
❆
❆
❆
❆
❆
❆
❆
❆
❆
1
2
3
4
6
8 7
9
10
5
LIGHT ON/OFF
SPEED
FAN
SLEEP COOL STRONG
In order to ensure the optimal performance of our
products, the design specifications of the unit and
remote control are subject to change without prior
notice.
The Energy Rating for this unit is based on the
installation of two unextended exhaust ducts.
Long press to decrease temperature
display brightness.
Long press to increase temperature
display brightness.

05 06
Disconnect battery instructions
Home AC outlet
13
1
2
4
2
3
4
Air conditioning power interface Mark 2 power adapter Home AC 100~240V(50Hz/60Hz) Air conditioner status light is red
*Use the official adapter provided by Zero Breeze. Do not use a third-party adapter.
Mark 2 can be battery operated or operated with the power adapter.
USE YOUR MARK 2
Tutorial on Operating with the included Adapter.
Tutorial Battery Operation.
Connect battery instructions
12
3
4
Align the four feet Pull back Connect the power cord Turn on the battery switch Air conditioner status light is red
Power off the battery Disconnect the power cord Press the buckle Pull forward Take off
5
24V power adapter

07 08
Battery Input Interface Mark 2 Power Adapter
Home AC 100~240V(50Hz/60Hz)
Home AC
100~240V(50Hz/60Hz)
Battery charging status indicator flashes
Charging the battery through the power adapter
BATTERY charging state
*Zero Breeze will not be held responsible for any consequences caused by charging with chargers not provided by Zero Breeze.
*When the battery level indicators are all on, it means that the battery is fully charged.
*The batteries shown in this manual need to be purchased separately, please refer to the zerobreeze.com for more details.
24V Power Adapter
*Take care not to place the drain hose close to the power supply.
*Make sure that the hose is fastened and that there are no leaks and no kinks that impede the flow of water. Make sure that the end of the hose is
facing down to allow the water to flow smoothly.
ACCESSORY CONNECTION Drain pipe connection instructions
LED1 LED2 LED3 LED4 LED5 Current power
0%-20%
20%-40%
40%-60%
60%-80%
Full
1.Air condition needs to be equipped with drain pipe.
Connect the drain pipe to the drain and place the other end of the drain pipe into a container or drain area.
2. The machine should be kept level when it is in use. It is best to leanitbackward5-10 degrees, not forward or left or
right, otherwise the condensate water will leakfrom the front, side andbottom of the air conditioner.
3. Do not move the air conditioner immediately after using the air conditioner. Tilt the air conditioner backwardsslowly
by 30 degrees to ensure that the water in the air conditioner is drained.
Note: if there is leakage due to improper placement, there is no need to be nervous, just wipe it or cool it naturally, it will
not affect the performance of the machine.
√ √ ×

09 10
Conventional tent / tent with air conditioning interface
Suggestions:
•Pay attention to tent insulation. If the tent is poorly insulated, cover the tent with an insulated mat.
•Pay attention to the tightness of the tent. For tents with vents, close or cover the vents.
•Pay attention to shade the tent, it is recommended to use it in the shade.
•If it is a large tent, beyond the cooling range of Mark 2, please add one or more air conditioners, or create a small
cooling space with a cloth partition in the tent.
>30cm >100cm
ACCESSORY CONNECTION Exhaust hose connection instructions
1 2
3
*When using the Mark 2 in a large space or
outdoor open space, the Mark 2 is
equivalent to a cooler, without the need to
connect the exhaust hose.
*When using in a small confined space and
want to cool down the space, please
connect the exhaust hose and place it
properly.
USE ENVIRONMENT
•Make sure that you install your unit on an even surface to minimize noise and vibration.
•If using with a power adapter, the unit must be put near a grounded plug.
•When Mark 2 is working and the air duct is not connected, make sure that there is no obstruction in the exhaust air
inlet and outlet at least 100cm, and there is no obstruction in the front supply air and inlet at least 30cm.
•DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.
Your installation location should meet the following requirements:
Electrical Safety
PLACED IN A TENT
When using outdoors, pay attention to waterproofing, especially in rainy days. Keep the exhaust and air inlets clear and prevent foreign objects from
blocking or inhaling.
1.Please leave Mark 2 flat for more than 30 minutes before turning on
when it is turned on for the first time, or after long distance or bumpy
transportation.
2.Please ensure Mark 2 is placed smoothly, not tilted, not upside down
when using it at any time.
Tips:

11 12
WINDOW INSTALLATION COLD AIR COLD AIR EXTENSION PIPE
INSTALLATION INSTRUCTIONS
Tools Needed
Knife
Cautions When Placing Exhaust Hoses
•To ensure proper functioning, do not extend or bend the hose excessively.
•Make sure there are no obstacles around the exhaust hose outlet (within 500mm) for the exhaust system to work
properly.
•All illustrations in this manual are for illustration only. Your air conditioner may be slightly different depending on the
actual product.
a.Use the protection panel (in the Mark 2 battery pack-
age) as the window baffle.
This is only included in Zero Breeze Plus and Zero
Breeze PE series.
b.DIY to cut out two circular holes with a diameter of
11cm, the distance of 15cm between each hole.
Use a utility knife to remove the excess. If the width is not enough, cut out some other foam and stitch it together.
Choose the right angle and place it on the window. Close the window and insert the two exhaust pipes into the round
holes.
This accessory can be used in some environments, such as the cab, where it is not convenient to place the Mark 2 for
cold air to reach the position we want. Remove the 2 rubber plugs on the front panel of Mark 2 and align the adapter
with Mark 2. Tighten the two screws, hold the adapter with one hand, and pull the air duct to the desired position.
•When adjusting the position of the cold air pipe, press the extension adapter with the other hand
•Not all models include this accessory
* (Not all models include this accessory)
Duct tape

13 14
AIR FILTER CLEANING MALFUNCTION DIAGNOSIS
Trouble Shooting Tips
E0 Error Code.
E1 Error Code
Unit does not cool well
The unit is noisy
and vibrates too
much
The unit makes a gurgling
sound
Unit stops frequently
Communication failure between driver
board and control board.
Temperature sensor error.
The air conditioner doesn’t work at
COOL or STRONG mode.
The air filter is blocked
with dust or animal hair.
Exhaust hose is not
connected or is blocked.
The unit is low on refrigerant.
The windows and doors in the
room are open.
The room area is too large.
There are heat sources inside
the room.
The floor is not level.
The air filter is blocked with
dust or animal hair.
This sound is caused by the flow of
refrigerant inside the unit.
The exhaust hose is blocked,
extended or otherwise restricted.
Contact the consumer service.
Contact the consumer service.
Set the working mode to COOL or STRONG mode.
Turn off the unit and clean the filter according
to instructions.
Turn off the unit, disconnect the hose, check for
blockage and reconnect the hose.
Contact the consumer service.
Make sure all windows and doors are closed.
Double-check the cooling area.
Remove the heat sources if possible.
Place the unit on a flat, level surface.
Turn off the unit and clean the filter according to
instructions.
This is normal.
Remove the exhaust hose to see if the unit
continues to operate. If yes, shorten the extension,
reduce the number of bends or eliminate restriction.
•Always unplug the unit before cleaning or servicing.
•DO NOT use flammable liquids or chemicals to clean the unit.
•DO NOT wash the unit under running water. Doing so causes electrical danger.
•DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be
replaced with a new cord from the manufacturer.
•Always clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth.
•Drain the unit's water collection tray by tilting the machine backwards.
•After draining the water run the unit on FAN mode for 12 hours in a warm room to dry it and prevent mold.
•Turn off the unit and unplug it.
•Clean the air filter . Always reinstall the clean, dry filter before storing.
Care and Cleaning
Symptom Possible Cause Solution
This manual suits for next models
4
Table of contents
Popular Air Conditioner manuals by other brands

Frigidaire
Frigidaire FAS183K2A1 Factory parts catalog

Samsung
Samsung AP500PF Service manual

Mitsubishi
Mitsubishi Mr. Slim PEA-A12AA4 installation manual

Carrier
Carrier 48-50 UH-UA installation instructions

Fujitsu
Fujitsu AOYG14KBTA2 Service manual

McLean Cooling Technology
McLean Cooling Technology ProAir CR29 instruction manual