manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zico
  6. •
  7. Data Logger
  8. •
  9. Zico ZI-9530 User manual

Zico ZI-9530 User manual

Other manuals for ZI-9530

1

Other Zico Data Logger manuals

Zico ZI-9530 User manual

Zico

Zico ZI-9530 User manual

Zico ZI-9630 User manual

Zico

Zico ZI-9630 User manual

Popular Data Logger manuals by other brands

UGCS SkyHub user manual

UGCS

UGCS SkyHub user manual

Avisaro 4.0 Series user manual

Avisaro

Avisaro 4.0 Series user manual

DDB C3 manual

DDB

DDB C3 manual

TESTO 176 instruction manual

TESTO

TESTO 176 instruction manual

HBM SOMAT XR CX22B-R operating manual

HBM

HBM SOMAT XR CX22B-R operating manual

Agtrix 380i manual

Agtrix

Agtrix 380i manual

Beijing ART Tech PCI2320 user manual

Beijing ART Tech

Beijing ART Tech PCI2320 user manual

Athena GET SL1 user manual

Athena

Athena GET SL1 user manual

Motec Systems C185 user manual

Motec Systems

Motec Systems C185 user manual

Beijing ART Tech USB2832 user manual

Beijing ART Tech

Beijing ART Tech USB2832 user manual

HT Italia XL421 user manual

HT Italia

HT Italia XL421 user manual

Racelogic VBOX LapTimer quick start guide

Racelogic

Racelogic VBOX LapTimer quick start guide

Edu-Logger 900-240 Guide

Edu-Logger

Edu-Logger 900-240 Guide

Elma DT173 manual

Elma

Elma DT173 manual

MadgeTech PRTemp140 Product user guide

MadgeTech

MadgeTech PRTemp140 Product user guide

Comet U0121M user guide

Comet

Comet U0121M user guide

pico Technology PT-104 user guide

pico Technology

pico Technology PT-104 user guide

Sensus DIAVASO user manual

Sensus

Sensus DIAVASO user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Temperature and Humidity
data logger Manual
3-Simple start:
① Check the battery indicator is normal.
② Connect the USB data logger to the Windows PC. The first time using, according to the computer
instructions, install the system’s own driver. Similar to A new U disk.
③ Setting the data logger. Please check the software CD, use the PC software setting the data
logger. For more information, please refer to the PC software help document.
④ Recording and download data.
First step: Open the software. Then open the setting window.
Second step: refer to the picture.
*Logger Name will synchronize to the PDF reports.
*Enable high and low alarm parameter will synchronize to the PDF reports.
Third step:
Fourth step: After recording some data, you can use the PC software download data.
Sample rate is 1minute, 10 minutes is ten data.
4-Sample rate & Record time
2
3
4
5
1
1-Product overview:
1. Sensor
2. Alarm indicator, red/green LED inside.
: green LED flashing, :Red LED flashing.
3. Electronic function key
4. Mechanical switch, hold down the switch,
then pull out the shell.
5. USB protecting hood. Connect PC software,
then you can setting up the data logger.
2-Replace battery
Hold down the switch,
then pull out the shell.
CR2450 Battery
After Setting
“Manual” mode
Waiting start
Long Press
Recording
Sample rate
/min
1
2
3
4
5
6
7
Record time
/day
13.9
27.8
41.7
55.6
69.5
83.4
97.3
Sample rate
/min
8
9
10
15
20
25
27
Record time
/day
111.2
125.1
139.0
208.4
277.9
347.4
375.2
5-LCD display and button
Display:
①... Alarm indicator
②... Battery indicator
③... Record indicator
④... Humidity unit
⑤... Humidity reading
⑥... Temperature unit
⑦... Temperature reading
⑧... Function indicator
Buttons:
① Down key
② Replace battery
③ Enter key
• Alarm indicator
Measurement values are within programmed limits. Green LED is flashing.
Measurement exceeded the programmed limits. If activated during programming a red LED
is flashing.
• Battery indicator
Full battery
Battery OK
Low battery
Empty battery, replace
• Recording indicators
The current state of the recording is indicated by the following symbols:
Waiting start
Recording stopped
Recording started
Appear after setting
234
5
6
7
1
8
23
1
www.zicotech.com
Zi-9530
Rev.180102
State 1:
The logger is in the “Manual ” mode, but the start key has not been not pressed yet.
State 2:
The logger is recording.
State 3:
Recording is stopped.
6-Function Menu
If the logger is not recording, only Start Recording is available.
Press the button to enter the function menu and to display humidity or air pressure,
and select the menu functions.
To activate a user menu function press the button and hold it for three seconds.
• Start Recording
To start the recording if the logger is in “Manual” mode.
• Stop Recording
In recording state, Press the button to select this function to stop recording.
Press button and hold it for three seconds.
After Setting
“Manual” mode
Waiting start
Long Press
Recording
Recording
Long press
Short press
Manual stop
page Stop record
•
The following picture shows remaining recording time is 12 days.
Max & Min
Short press button switch shows the highest reading since start of recording.
Short press button switch shows the lowest reading since start of recording.
Generating a PDF-File
As soon as the logger is connected to a USB-slot, a PDF file with all recorded data in chart and an
overview of alarms is generated automatically. During PDF generation “USB PDF” appears on the
display, green and red led light indicator, when the PDF file is ready “PDF” disappear and remaining
“USB” on the display.
Depending on the number of stored measurements, generating the PDF-file might take up to
30 seconds.
As soon as the logger is reprogrammed, the PDF file on the logger will be deleted.
Remaining Recording Time
Display the remaining time until end of recording.
•
•
Short press
Short press
Max Min
7-LED Status Guide
Relative Humidity
Temperature
Display condition
8-Specification (T = 25℃ unless otherwise noted)
0 to 100%
±5.0%
±3.5%
±3.0%
0.1
Overall Range
Accuracy (0 to 20 and 80 to 100%)
Accuracy (20 to 40 and 60 to 80%)
Accuracy (40 to 60%)
resolution
Overall Range
Action
-Logging
-Logging, low alarm or high alarm.
-Manual mode waiting start
-Memory full
-Stop upon key
-Setup successful
-check upgrade file successful
LED Indication
Cycle green single flash
Cycle red single flash
Green double flash one time
-30 to 60℃(-22 to 140℉)
±1℃,±1.8℉
±0.5℃,±0.9℉
0.1
Accuracy(-30 to +0℃,-22 to 32℉)
Accuracy(0 to 60℃,32 to 140℉)
resolution
-30~60℃
Temperature and Humidity 20010 1min~24h
Type Data memory Sample rate
Remark:
CR2450 battery performance is optimal in room temperature. Battery life cycle will reduce at low
temperature (-18℃). If the device is to be used to record in extremely low temperature, it is advised
to take measures to reduce power consumption to prolong operation time. An option includes:
• Choose battery that is designed to operate at low temperature
• Disable LED to reduce power consumption
• Set longer sample interval, 5 minutes for example
9-Firmware upgrade
User can also upgrade its firmware in this page.
In this page, long press and display will show “UP+USB”
Then insert the device into the PC USB port. The device will appear as a Mass Storage Device in PC
with no content.
Drag and drop the firmware to the folder.
The device will disappear in the OS. DO NOT unplug the device from PC. It takes around
After upgrade completed, Device will automatically appear as a Mass Storage Device again.
The firmware version is indicated in the left bottom corner of the .pdf test report generated.
10-Restore Default factory firmware
Remove the battery, in the following order:
1. Hold down the button (until power on) ; connect to the computer USB, the green
LED light up.
2. Waiting for 2 minutes, computer will identify the instrument USB disk.
11-Delete all data
Logger work normally on battery power. Hold down two buttons , connect to the
computer USB, the logger will delete all data.
*If waiting for 5 minutes and the instrument can’t connect to the computer, maybe need to restore
default factory firmware, or need to delete all data.
Firmware
upgrade page
Long Press
Short press
Firmware
upgrade page
Connect PC,
paste firmware
flie to the logger
disk.
Waiting 2 minutes
or red LED OFF.
www.zicotech.com
Zi-9530