Seng Up the Smoke Detector:
Remove the front cover by pulling as shown in the image above. Remove the insulator
of the baery to power the detector and close back the cover. Press the Sengs
Buon once to acvate the smoke detector.
Note: Install the smoke detector away from possible smoky places (cooking hob, oven
etc).
Smoke sensor has two different indicator, a green light and a red light.
Red Light Meanings:
1. In the User Mode; Red light flashing rapidly or illuminang connuously indicates
that alarm is triggered.
Green Light Meanings:
INSTRUCTIONS
1. In the User Mode; Green light blinking shows that device is working normally.
2. In the User Mode; If you press and hold the Sengs Buon green light will
illuminate connuously indicang that device is in Sengs Mode.
3. In the Sengs Mode; Flashing 5 mes indicates that a wrong buon input or
wrong command have entered.
4. In the Sengs Mode; Flashing 2 mes indicates that the entered command was
successful.
5. In the Sengs Mode; Flashing rapidly indicates that a network connecon is being
made. Green light will flash 3 mes aer connecon made successfully.
Red and Green Light Illuminang Together:
1. If the device is not connected or disconnected from network green and red light will
flash 3 mes simultaneously.
2 To test if the device is working normal or not press the Sengs Buon once. If the
red light flashes 3 mes and alarm sounds 3 mes, that indicates alarm is armed and
working normally.
LED LIGHT CODES
CONTACT
Network Connecons:
Press and hold the Sengs Buon ll the green light illuminates connuously. When
the green light turns on press the buon once(green light will flash once aer
pressing the buon).
Press and hold the buon again ll the green light turns on. Once the device starts
searching for the network the green light will start flashing rapidly and when the
connecon has been made green light will flash 3 mes.
Note: Before connecng this device, network connecon mode should be acvated
on the Gateway by using the Sengs Buon on it.
Factory Sengs:
Press the Sengs Buon for 3 seconds ll the green lights illuminates connuously.
Then press and release the Sengs Buon 10 mes(green light will flash once aer
each pressing). Press and hold the Sengs Buon for 3 seconds. Green light will flash
3 mes indicang that device is successfully returned to factory sengs.
Note: If you press the Sengs Buon more or less than 10 mes green light will flash
55 mes indicang that the process was unsuccessful. You can connue the process by
pressing 10 mes as explained above.
Note: You have to set the network sengs aer returning back to factory sengs.
SHENZHEN VIDEOCOM ELECTRONICS TECHNOLOGY CO.LTD.
5th.Floor East 2nd.Building, Peng Teng Da Industrial Park,
HuarongRd.Longhua, Bao an District Shenzhen CHINA
VIDEOCOM ELEKTRONIK VE BILGISAYAR SISTEMLERI A.S.
Ivedik OSB 1419.Cad. No:72 06370 Y.Mahalle Ankara TURKIYE
VIDEOCOM-UK ELECTRONICS AND SOFTWARE LTD.
Unit 2, Little Britain House, Alma Road, Chesham,
Buckinghamshire, HP5 3HB London, United Kingdom
Headquarter
Distributor
Factory