Zinc ZN25154 User manual

Thebe 360 Degree
Surface Mount PIR
With 3 Sensors
ZN25154
3 ×DETECTOR
User Instructions
Welcome to use ST05B infrared motion sensor!
The product adopts good sensitivity detector and integrated circuit. It gathers automatism,
convenience, safety, saving-energy and practical functions. It utilizes the infrared energy from
human as control-signal source and it can start the load at once when one enters detection field. It
can identify day and night automatically. It is easy to install and used widely.
SPECIFICATION:
Power Source: 220-240V/AC Detection Range: 360°
Power Frequency: 50Hz Detection Distance: 12m max(<24℃)
Ambient Light: <3-2000LUX (adjustable) Working Temperature: -20~+40℃
Time Delay: Min.10sec±3sec Working Humidity: <93%RH
Max.15min±2min Power Consumption: approx 0.5W
Rated Load: Max.1200W InstallationHeight:2.2-4m
300W Detection Moving Speed: 0.6-1.5m/s
FUNCTION:
Can identify day and night: The consumer can adjust working state in different ambient light.
It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can
work in the ambient light less than 3LUX when it is adjusted on the “3” position (min). As for
the adjustment pattern, please refer to the testing pattern.
Time-Delay is added continually: When it receives the second induction signals within the
first induction, it will restart to time from the moment.
Good sensitivity Poorsensitivity
INSTALLATION ADVICE:
As the detector responds to changes in temperature, avoid the following situations:
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors
etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units,
light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall
plants etc.
CONNECTION:
Warning. Danger of death through electric shock!
Must be installed by professional electrician.
Disconnect power source.
Cover or shied any adjacent live components.
Ensure device cannot be switched on.
Check power supply is disconnected.
Please move the upper cover with anti-clockwise whirl as per the
diagram on the right.
Connect the power and the load according to the
connection-wire diagram.
Fix the bottom on the selected position with the inflated screw.
Install back the upper cover on the sensor, then you could switch
on the power and test it.
CONNECTION-WIRE DIAGRAM:
(See the right figure)
TEST:
Turn the TIME knob anti-clockwise on the
minimum (10s).Turn the LUX knob clockwise
on the maximum (sun).
Switch on the power; the sensor and its
connected lamp will have no signal at the
beginning. After Warm-up 30sec, the sensor
can start work .If the sensor receives the induction signal, the lamp will turn on. While there is
no another induction signal any more, the load should stop working within 10sec±3sec and
the lamp would turn off.
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX,
the sensor would not work and the lamp stop working too. If the ambient light is less than
3LUX (darkness), the sensor would work. Under no induction signal condition, the sensor
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the
sensor lamp could not work!
SOME PROBLEM AND SOLVED WAY:
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to receive
the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in the
instruction.
e. Please check if the moving orientation is correct.
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction.
Helpline
If you receive this item with parts broken or missing, please telephone:
0333 005 0077
Please have ready your name, address, tel. no., product reference, where purchased
and parts required. An answering service is in operation outside office hours and during busy
periods.
We regret that we are unable to give advice on internal house wiring.
Cascade Holdings Ltd, Gorse Mill, Gorse Street, Chadderton, Oldham. OL9 9RJ

Other Zinc Accessories manuals

Zinc ZN25152 User manual

Zinc

Zinc ZN25152 User manual

Zinc ZN25152 User manual

Zinc

Zinc ZN25152 User manual

Popular Accessories manuals by other brands

Orbegozo HUA 3500 instruction manual

Orbegozo

Orbegozo HUA 3500 instruction manual

Amana POWER VENT & DOOR KIT installation instructions

Amana

Amana POWER VENT & DOOR KIT installation instructions

Stamina 35-1704A owner's manual

Stamina

Stamina 35-1704A owner's manual

Gamko FK user manual

Gamko

Gamko FK user manual

Hukseflux SR30-M2-D1 manual

Hukseflux

Hukseflux SR30-M2-D1 manual

Utilitech UT-7353 quick start guide

Utilitech

Utilitech UT-7353 quick start guide

Homematic IP HmIP-PS-2 operating manual

Homematic IP

Homematic IP HmIP-PS-2 operating manual

Invonics EN1240-60 installation instructions

Invonics

Invonics EN1240-60 installation instructions

Spector&Co Spectech T138 manual

Spector&Co

Spector&Co Spectech T138 manual

Covidien Nellcor MAXA Instructions for use

Covidien

Covidien Nellcor MAXA Instructions for use

Basalte BO.sensor manual

Basalte

Basalte BO.sensor manual

dbell HD Live user guide

dbell

dbell HD Live user guide

Behringer U-PHORIA UMC404HD quick start guide

Behringer

Behringer U-PHORIA UMC404HD quick start guide

Wavetronix Click 510 quick start guide

Wavetronix

Wavetronix Click 510 quick start guide

Suunto Tank POD user guide

Suunto

Suunto Tank POD user guide

Honeywell C7110A1010 installation instructions

Honeywell

Honeywell C7110A1010 installation instructions

Novalynx 200-WS-03D instruction manual

Novalynx

Novalynx 200-WS-03D instruction manual

wtw Oxi ML 41 operating manual

wtw

wtw Oxi ML 41 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.