ZX420 Series User Guide Page 7
TROUBLESHOOTING
All ZNYX Networks adapters support Plug-and-Play functionality. If you have a Plug-and-
Play system, your card will configure itself automatically. If your operating system does not
discover the board, you can verify that your adapter is property configured by running the
ZNYX Networks DOS-based diagnostics program.
Running DOS Diagnostics
DOS-based diagnostic programs are available from the ZNYX Networks web site
(www.znyx.com) to troubleshoot hardware problems. If you believe you have a hardware
problem, follow the testing procedure below.
Testing ZX420 Adapters in DOS
1. Download the diagnostic program (i.e., DIAG424.exe) from the ZNYX web site.
2. Run the diagnostic program in DOS as follows:
• Enter the following command:
>DIAG424 LIST
• Verify that a list similar to the example below is displayed.
Your card is automatically configured for the ZX424 if four Ethernet-type devices
(represents each port) are listed.
The Note column must indicate four devices are for the ZX424. Each device should
have an IRQ (interrupt line), bus value, and a unique device number.
3. Write down the bus and device numbers for testing each adapter channel (see the
Testing Each Adapter Channel section).
DIAG424 Version 2.05 for ZNYX NetBlaster ZX424 4/100 Mbps adapter
(c) Copyright 2000 ZNYX Corporation - All Rights Reserved.
PCI BIOS Information: Version=2.10, Config Mechanism=1, Last Bus=1
Bus Dev Fn Vendor Device Rev Type Lat IL IRQ Note
========== ================= ============ ========== =====
0 0 0 8086 1250 03 Host Bridge 20 - -
0 7 0 8086 7000 01 PCI-ISA 00 - -
0 7 1 8086 7010 00 IDE 20 - -
2 4 0 1011 0019 01 Ethernet 73 A 10 ZX424
2 5 0 1011 0019 41 Ethernet 73 A 10 ZX424
2 6 0 1011 0019 41 Ethernet 73 A 10 ZX424
2 7 0 1011 0019 41 Ethernet 73 A 10 ZX424
1 0 0 8086 7800 21 VGA 0 A 5
ZX424
includes
four
Ethernet
devices
in list