manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zoeller
  6. •
  7. Plumbing Product
  8. •
  9. Zoeller Tru-Flow 173-0001 User manual

Zoeller Tru-Flow 173-0001 User manual

NOTICE TO INSTALLER: Instructions must remain with installation.
© Copyright 2021. All rights reserved.
HELPFUL INFORMATION FOR EASY INSTALLATION
FILTERED
SLUDGE LAYER
ZOELLER 24 OR 30 INCH ACCESS RISER & LID
STANDARD 4" INLET
TEE OR BAFFLE
CLEAR EFFLUENT
SCUM LAYER
EFFLUENT
COUPLING, RUBBER
(SHOWN) OR PVC
OUTLETS TO
DRAIN FIELD
ZOELLER
ZOELLER SPLITTER SYSTEM
(SUPPLIED BY OTHERS)
FILTER
4" PIPE & CAP (SUPPLIED BY OTHERS)
OR OPTIONAL ZOELLER 6" RISER (SHOWN) P/N 173-0007
SK1975
1. Inspect your Zoeller Pump Company Tru-Flow®Splitter System
unit. Occasionally products are damaged during shipment. If unit is
damaged, contact your dealer before starting the installation.
2. Carefullyreadtheliteratureandinstallationinstructionstofamiliarize
yourself with specic details regarding installation. These materials
should be retained for future reference.
3. The use of an efuent lter is strongly recommended in order to
protect components downstream from the septic tank.
Note: The TRU-FLOW®Splitter System must sit level on undisturbed ground or on packed sand or gravel
before backfilling.
1. Zoeller Pump Company Tru-Flow®Splitter Systems are designed for installation on the outlet pipe of the septic tank. If a complete system
has been purchased, all the components will be included except the trench pipes, ttings, and any necessary risers (See Figure Below).
2. If the Zoeller Pump Company Tru-Flow® Splitter System is being retrotted into an existing septic system, it may be necessary to pump and
clean out the septic tank before attempting to install the splitter system.
3. The septic tank outlet pipe and all trench pipes should be exposed or accessible for connections or insertion to the splitter system.
SECTION: C4.00.003
CL0075
0421
Supersedes
0321
Product information presented
here reects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
Visit our website:
zoellerpumps.com
OWNER'S MANUAL
Register your
Zoeller Pump Company Product
on our website:
http://reg.zoellerpumps.com/
Splitter System
®
2
© Copyright 2021. All rights reserved.
STEP 1 Splitter System Outlets
1.1) Determine the number of outlets to be used on the
splitter system based on the layout of the trench eld.
When pumping to the splitter system, optimum results
are obtained if:
a.) Installations requiring 4 slot openings/trench lines
utilize slot openings 1, 2, 4, & 5.
b.) Installations requiring 3 slot openings/trench lines
utilize slot openings 1, 3, & 5.
1.2) Score and cut through with a knife at the bottom of
v-groove. If required score several times around and
cut through. DO NOT HIT WITH A HAMMER.
1.3) Trim and clean the diameter of the hole, leaving it the same
as the molded diameter. DONOTOVERTRIMDIAMETER.
Refer to Figure 2.2
STEP 2 Installation of Pipe Seals and Slotted Pipe Nipple
Splitter system is supplied with pipe seals that accommodates 4" SDR 35 and Sch 40 pipe.
2.1) Apply sealant around mating surface of pipe seal as shown in Figure 2.1. Repeat for each required pipe seal.
2.2) Place pipe seals in necessary holes as shown in Figure 2.2 & Figure 2.3.
2.3) Insert slotted pipe nipple through the inlet hole and pipe seal, pushing through about 3/4". See Figure 2.4.
Note: Assure the slot end of the pipe nipple is inside the basin and the slot is facing upward and centered.
Figure 2.1 Figure 2.3
STEP 3 Installation of Assembled Basin
3.1) Set basin into place.
3.2) Insert necessary trench pipes into basin, pushing through
approximately 1-1/2". See Figure 3.1. The number of pipes
varies for each installation.
3.3) Connect the inlet pipe to slotted pipe nipple with a coupling
(exible rubbers shown). Do not tighten coupling at this
time. If used see Figure 3.2.
3.4) Installations in which the splitter system will be pumped to
are required to have at least a 3' length of 4" PVC and a 4"
elbow connected to the slotted pipe nipple. See Figure 3.3
for required positioning of elbow. This piping conguration
will promote smooth uniform ow. The piping from the pump
to the elbow should be sized based on the pump discharge.
Use bushings/reducers as necessary to connect to the
elbow.
3.5) Maximum ow through the splitter system is dependent on
thenumber oftrench pipeopenings. Thesplittersystemcan
handle 30 gpm with 5 openings, 21 gpm with 4 openings,
17 gpm with 3 openings and 13 gpm with 2 openings.
Note: Assure slot in pipe nipple is centered and facing upward
when connecting coupling or PVC.
Note: Basin must be leveled at this time in both directions.
Note: The splitter system must sit level on undisturbed ground or
on packed sand or gravel before backlling.
SK1941
Figure 2.2 Figure 2.4 SK1942
Figure 1.2
SK1956
SK1944
Figure 3.2
SK1943
Figure 3.1
SK2100
Figure 3.3
INLET HOLE
(DO NOT USE FOR OUTLET)
POSSIBLE CUTOUTS
MOLDED IN HOLES
SK1939
Figure 1.1
BOTTOM OF
V-GROOVE
BASIN WALL
MOLDED
DIAMETER
SK1973
MATING
SURFACE
SK1940
PIPE
DIRECTION
OUTSIDE OF
BASIN WALL
PIPE SEAL
DO NOT OVER
TRIM KNOCK-OUTS
BUCKLE SEAL TO INSERT. 3/4"
SLOTTED
PIPE NIPPLE
SLOT
SLOTTED
PIPE NIPPLE
OUTLET PIPES
1 1/2
SEPTIC TANK
OUTLET PIPE
COUPLING, RUBBER
(SHOWN) OR PVC
(SUPPLIED BY OTHERS)
DO NOT TIGHTEN
FOR THIS STEP
NUMBER OF TRENCH
PIPES VARIES FOR
EACH INSTALLATION.
4" PVC PIPE
MINIMUM 3' LENGTH
COUPLING, RUBBER
(SHOWN) OR PVC
(SUPPLIED BY OTHERS)
DO NOT TIGHTEN
FOR THIS STEP
NUMBER OF TRENCH
PIPES VARIES FOR
EACH INSTALLATION.
4" PVC ELBOW
ORIENTATION AS
SHOWN.
PUMPED EFFLUENT
3
© Copyright 2021. All rights reserved.
STEP 5 Installation of Diverter and Thumb Screw
5.1) Set diverter into place and insert slotted pipe nipple
into the diverter. See Figure 5.1.
5.2) Engage 3/8"-16 thumb screw and large washer
onto the diverter as shown in gure 5.2. DO NOT
OVERTIGHTEN THUMB SCREW.
5.3) Slide diverter and slotted pipe nipple as far forward
as possible, see arrow in Figure 5.1.
5.4) Tighten rubber coupling, which connects inlet
pipe and slotted pipe nipple.
Figure 5.1 Figure 5.2
STEP 6 Installation of Level and Initial Adjustment
6.1) Snap level into the diverter. See Figure 6.1.
6.2) Level the diverter by use of the thumb screw and tap the bottom surface of
the diverter at “A” & “B” see Figure 6.1.
See Figure 6.2. DO NOT OVER TIGHTEN THUMB SCREW.
Figure 6.2
STEP 7 Installation of Riser and Cover
7.1) Apply ample amounts of RTV Silicone to outside of SCH40 or SDR35 pipe (supplied by others).
7.2) Attach riser pipe SCH40 or SDR35 (supplied by others) to cover as shown in Figure 7.1.
7.3) Place an ample coating of RTV Silicone around the basin lip to form a gasket.
7.4) Place cover onto basin, then attach washers and screws as shown in Figure 7.2. Repeat where necessary.
7.5) Fill in dirt around splitter system, necessary pipes, connections, risers, and trenches.
Note: Assure riser opening is capped to prevent debris from entering the splitter system. Do not glue cap.
Flag location of splitter system riser to prevent damage.
Figure 7.1 Figure 7.2
SK1947
SK1948
SK1951 SK1952
Note: Do not over tighten screws.
STEP 4 Installation of Slot Covers
4.1) Determine the required number of slot covers from Figure 1.1 and the required
bafe slot for each slot cover. See Figure 4.1.
4.2) Blank slot covers should be installed in the bafe slot openings of 2, 3 and 4 if their
corresponding cutouts are not to be used for trench pipes. See Figure 1.1 and
4.1. When cutouts 2 and/or 3 and/or 4 are used and the splitter system is being
pumped to, these bafe slots must have slot covers with the restrictor opening
installed.
4.3) Apply RTV Silicone or PVC cement to the bottom and sides of the necessary slot
cover. See Figure 4.2.
4.4) Place slot cover into bafe slot. Apply additional RTV Silicon or PVC cement as
needed along edges. See Figure 4.2. Repeat steps 4.3 & 4.4 for each required slot
cover.
Note: Assure each required slot cover is sealed to prevent leakage into D-Box basin.
Figure 4.2
1 2
3
4
5
SK1945 SK1946
Figure 4.1
SLOTTED
PIPE NIPPLE
DIVERTER
CONNECT
SLOT
THUMB SCREW
WASHER
"A"
"B"
SK1949
Figure 6.1
ADJUST DIVERTER ROTATION
SEE STEP 6.2
ADJUST TIGHTNESS
BY USE OF
THUMB SCREW
LEVELING DEVICE
SK1950
SCREWS
PIPE (SUPPLIED BY OTHERS)
BASIN
LID
SLOTTED
PIPE NIPPLE
DIVERTER
CONNECT
SLOT
SK1947
Apply RTV
Silicone
Apply RTV
Silicone
© Copyright 2021. All rights reserved.
STEP 8 Final Adjustment
8.1) Check the level on the diverter. If adjustment is not needed, proceed to the next step. If adjustment is needed, reference the Maintenance
Instructions (below) for proper adjustment and leveling of the diverter.
Your new Zoeller Pump Company Splitter System is now in service.
Maintenance
1) Remove cap on riser.
2) Check the level on the diverter with ashlight. If the level does not
need adjustment, then maintenance is not required at this time. If
level is not centered between the lines, then proceed to the next
step.
3) Loosen the thumb screw (two full turns max) until the diverter can
be adjusted. The thumb screw can be adjusted by hand or by using
a 3/4" pipe ( not supplied) with a slot as shown in Figure A.1.
4) Using the 3/4" pipe, or by hand, tap at point “A” or “B” on the
bottom surface of the diverter until the diverter is level. See Step 6
on page 3, Figure 6.1.
5) Once the diverter is leveled, tighten the thumb screw until the
diverter is stationary. DO NOT OVERTIGHTEN THE THUMB SCREW.
Check bubble level with ashlight. If diverter becomes unlevel
during tightening, repeat steps 3, 4 and 5.
6) Replace cap on riser.
The splitter system should be checked annually in conjunction with your yearly septic system inspection.
THUMB SCREW
3/16" X 3/16"
SLOT
3/4" PIPE
AS NEEDED
Figure A.1
SK1953
All Zoeller Pump Company products must be installed and maintained in accordance with all applicable codes.
Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies.
Replacement Parts List for Model 173-0001 Splitter System
SK1954
REF.# DESCRIPTION QTY. PART
173-0001
1Hardware Pack 1013236
2 Cover 1 013043
3 Slotted Pipe Nipple 1 013241
4 Diverter 1012925
5 Basin 1013044
8 Thumb Screw, Plastic 3/8"-16 1013239
10 Washer, SS-1" O.D. 1006413
(BLANK COVER)
(3 SEALS NOT SHOWN) (2 COVERS NOT SHOWN)
(RESTRICTOR COVER)
(2 COVERS NOT SHOWN)
4
14
13
10
11
12
5
3
9
8
6
2
1
HARDWARE PACK P/N 013236
REF.# P/N DESCRIPTION QTY.
6 014515 Screw, SS#12 x 3/4" Phillips 12
9 013238 Pipe Seal, Tuf-Tite/ Yellow 6
11 013237 Bubble Level, 3/8" x 1 3/8" LG 1
12 013240 Slot Cover 3
13 011644 Screw, SS #10-16 x 1/2" Phillips 2
14 013753 Cover, Slot Diverter 3
Lifetime Warranty: Every Zoeller Splitter System is guaranteed to be free from defects in materials and workmanship for the lifetime of the homeowner/purchaser. Free repair or
replacement, excluding labor, will be made on return of the splitter system prepaid to the factory. This warranty is limited to product proven to be free from abuse or improper installation.

Other Zoeller Plumbing Product manuals

Zoeller SRS User manual

Zoeller

Zoeller SRS User manual

Zoeller QWIK JON PREMIER 201 User manual

Zoeller

Zoeller QWIK JON PREMIER 201 User manual

Zoeller QWIK JON 200 User manual

Zoeller

Zoeller QWIK JON 200 User manual

Zoeller 910 User manual

Zoeller

Zoeller 910 User manual

Zoeller QWIK JON 100 User manual

Zoeller

Zoeller QWIK JON 100 User manual

Zoeller QWIK JON ULTIMA 202 User manual

Zoeller

Zoeller QWIK JON ULTIMA 202 User manual

Zoeller QWIK JON PREMIER 201 Operation and maintenance manual

Zoeller

Zoeller QWIK JON PREMIER 201 Operation and maintenance manual

Zoeller Qwik Jon Ultima 204 User manual

Zoeller

Zoeller Qwik Jon Ultima 204 User manual

Zoeller 1910-0009 User manual

Zoeller

Zoeller 1910-0009 User manual

Popular Plumbing Product manuals by other brands

Isenberg Ecomatic CFB.2300 installation manual

Isenberg

Isenberg Ecomatic CFB.2300 installation manual

Oras Saga 3941 Installation and maintenance guide

Oras

Oras Saga 3941 Installation and maintenance guide

Blanco BLANCOTERA ND INSTALLATION AND CARE INSTRUCTIONS

Blanco

Blanco BLANCOTERA ND INSTALLATION AND CARE INSTRUCTIONS

Kohler Symbol 18471-4FP installation instructions

Kohler

Kohler Symbol 18471-4FP installation instructions

Symmons Dia SLS-3512 Series Installation Brief

Symmons

Symmons Dia SLS-3512 Series Installation Brief

Hans Grohe Metropol Classic 31304 Series Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Metropol Classic 31304 Series Instructions for use/assembly instructions

artedomus ASEN0958O Instructions for installation

artedomus

artedomus ASEN0958O Instructions for installation

Wirquin PRO CHRONO Assembly instructions

Wirquin

Wirquin PRO CHRONO Assembly instructions

Axor Starck FixFit Round 27451 Series Assembly instruction

Axor

Axor Starck FixFit Round 27451 Series Assembly instruction

HydroMinder 511 user manual

HydroMinder

HydroMinder 511 user manual

KWC DOMO 11.062.002.000 Installation and service instructions

KWC

KWC DOMO 11.062.002.000 Installation and service instructions

Moen 9417 Series installation guide

Moen

Moen 9417 Series installation guide

American Standard One 2064.15X installation instructions

American Standard

American Standard One 2064.15X installation instructions

Maxxus MX-J206-01 instruction manual

Maxxus

Maxxus MX-J206-01 instruction manual

SBM KIT QDC-DXP Assembly instructions

SBM

SBM KIT QDC-DXP Assembly instructions

Dietsche RD540 Assembly instruction

Dietsche

Dietsche RD540 Assembly instruction

OVE BREEZE B14 user manual

OVE

OVE BREEZE B14 user manual

ALTMANS Nuva NU14 installation instructions

ALTMANS

ALTMANS Nuva NU14 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.