B.TECHNICALSPECIFICATION
C.OPERATIONINSTRUCTION D.TROUBLESHOOTING
Note: Thistroubleshootingisforreferencepurposesonly.Ifanytechnicalassistanceinneeded,please
yourdistributorforservice.
MODEL AIRFLOW VOLTAGE POWER WATER
CAPACITY
DIMENSION
(cm) N.W
ESC-45P-4R 4500cmh 110V/60Hz 120W 40L 49*36.5*97 12.5kg
ESC-50P-4R 5000cmh 110V/60Hz 150W 50L 56*37*110 15kg
ESC-60P-5RN 7000cmh 110V/60Hz 200W 70L 66*46*117 20kg
Keypad
Instruction Comment
ON/OFF Makethecoolerstartorstoptowork.
Model Normal/Natural/Sleep
Timer Toselect1H-12Hworkingtime
Speed Toselectlow,mediumorhighfanspeed.
Swing Tomaketheventautoswing(leftandright)
Cooling Tomakethepumpstarttoworkandactivatesthecoolingfunction.
Night Turnon/offthelightofscreen.
Malfunction Reason Solution
-Operatingscreen
staysdark
-Nopower
-Maincontrolboardfailure
-Fuseisblown
-Panelfailure
-Checkunitispluggedin
-Changecontrolboard
-Changefuse
-Changepanel
-Displayisnormal
Butwithoutair
Flowortheair
Speedistoolow
-Thefanisjammed
-Coolingpadordustfilteris
blocked
-Fanisdistorted
-Maincontrolboardfailure
-Checktoensurethereisnothing
Preventingfreerotationofthefan
-Cleanthecoolingpadanddustfilter
-Changethefan
-Changethemaincontrolboard
-Motordoesnot
Respondtocontrol
panel
-Maincontrolboardfailure
-Panelfailure
-Changethemaincontrolboard
-Changethepanel
-Waterleaking
Fromdrainvalve
-Drainvalveisloose
-Dirtinvalve
-Tightendrainvalvenut
-Cleandrainvalve
-Airdiffuser/swing
Functionnotworking
-Synchronousmotorburntout
-Crankshaftisbroken
-Changesynchronousmotor
-Changecrankshaft
-Waterdropssplash
Outoftheairdiffuser
-Waterpipehascomeloose -Checkwaterpipetotopoffilterpad