CONTENTS
1. Installation 5
1.1 EQUIPMENT 5
1.2 CONNECTING THE ZVK-007 TO THE ZoneVu NETWORK 5
1.3 KEYBOARD ADDRESS 5
1.4 SERIAL COMMUNICATIONS 5
2. GETTING STARTED 6
2.1 POWER-UP MESSAGES 6
2.2 LOGGING ON 6
2.3 MODE SELECTION 7
3. CLASIK MODE 7
3.1 CLASIK MODE FACILITIES 7
3.2 SELECTING A CAMERA 8
3.3 SELECTING A MONITOR 8
3.4 CAMERA CONTROL 8
3.5 RELEASING CAMERA CONTROL 9
3.6 SALVO SEQUENCE 9
3.7 PLACING A MONITOR INTO SEQUENCE MODE 9
3.8 GLOBAL FACILITY 10
3.9 PRESET FACILITY 10
3.10 PATROL FACILITY 10
3.11 LATCHED CAMERA FUNCTIONS 11
3.11.1 FUNCTION TIMEOUT OVERIDE 11
3.12 ZONAL SWITCHING 11
3.12.1 SELECTING ZONES 12
4. Site Mode 12
4.1 SITE MODE FACILITIES 12
4.2 SELECTING A SITE 12

MEYERTECH LIMITED ISSUE 09
4.3 SELECTING A TRUNK 13
4.4 SELECTING A CAMERA 13
4.5 SELECTING A MONITOR 14
5. PCI MODE 14
5.1 PCI MODE FACILITIES 14
6. SUPERVISOR LEVEL 14
6.1 SUPERVISOR LEVEL FEATURES 14
6.2 SELECTING AN OPTION 15
6.3 PASSWORDS 15
6.3.1 CHANGING A PASSWORD 15
6.4 MODE ACCESS 16
6.5 KEYBOARD SET-UP 16
6.5.1 KEYBOARD CAMERA ACCESS 17
6.5.2 KEYBOARD MONITOR ACCESS 17
6.5.3 KEYBOARD ENGINEERING FACILITIES 18
6.5.4 ZONE SETUP 18
6.6 FEATURE ACCESS 19
6.7 ZVR CONFIGURATION 20
6.8 CAMERA CONFIGURATION 21
6.9 ZVM-CONFIGURATION 22
7. VCR MODE 23
7.1 SELECTING A VCR 23
8. MUX MODE 24
8.1 SELECTING A MULTIPLEXER 24
9. TROUBLE SHOOTING GUIDE 25
10. DECLARATION OF CONFORMITY 26
11. Product Warranty 27
12. DOCUMENT HISTORY 28
Page 3http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Whilst every effort has been made to confirm the information in this document is correct,
MEYERTECH LIMITED cannot accept any liability for any errors, omissions and or incorrect
information contained within this document.
No part of this document may be reproduced or distributed in any form or by any means
without prior written consent from MEYERTECH LIMITED
MEYERTECH LIMITED are committed to continuous product development and therefore reserve
the right to change specifications without notice.
©1997-2004 ALL RIGHTS RESERVED.
Page 4 http://www.meyertech.co.uk MAN-007

MEYERTECH LIMITED ISSUE 09
1. INSTALLATION
1.1 EQUIPMENT
The ZVK-007 should be carefully unpacked and the contents checked against the list below.
ZVK-007 KEYBOARD (19 Inch By 4U Panel Mounted)
MAINS CUBE PSU.
ZoneVu NETWORK NODE BOX
1.2 CONNECTING THE ZVK-007 TO THE ZONEVU NETWORK
STEP 1 Wire the Mains Cube PSU to the Network Node box observing the
polarity. Set the PSU to give +12V output.
STEP 2 Wire the Network Node box to the ZoneVu Network observing the
polarity of the connections and ensuring that the screen of the Network
cable is connected to the PSU 0V connection.
STEP 3 Plug the Mains Cube into a convenient power socket.
STEP 4 Plug the ZVK-007 into the FCC connector on the Network Node box.
1.3 KEYBOARD ADDRESS
Each keyboard connected to the ZoneVu network requires a unique Module Access Code (MAC) to
function correctly. Set the MAC by following the procedure in Section 6.5.3.
NOTE ! The MIC (Module Identification Code) is not used by the ZVK-007 and can be ignored.
1.4 SERIAL COMMUNICATIONS
The ZVK-007 can operates on a RS422 Topology with the following parameters -
BAUD RATE - 9600 / 19200 / 38400 STOP BITS - 1
DATA BITS - 8 FRAME - 10 BIT
PARITY - NONE FLOW - NONE
Page 5http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 6 http://www.meyertech.co.uk MAN-007
2. GETTING STARTED
2.1 POWER-UP MESSAGES
Whenever the keyboard is powered-up the following messages are displayed by the LCD. Examples
shown.
KEYBOARD MODEL AND COPYRIGHT
SOFTWARE VERSION - 4.21.0.0
RELEASE DATE - 13-05-04
MODULE ACCESS CODE - MAC 01
BAUD RATE - 9600 baud
PRIORITY -1
MODE - Matrix Mode
2.2 LOGGING ON
The ZVK-007 has four levels of access, three User levels and one Supervisor level and is fully LOG
ON / LOG OFF Password Protected.
USER LEVELS can be programmed to allow access to different modes e.g. - CLASIK and PCI.
Keyboard Configuration Management is carried out from the SUPERVISOR LEVEL. User Level
Access, Password allocation and Keyboard Set-up has to be carried out from this Level. Video Matrix
Configuration and Camera Receiver Configuration can also be carried out from this Level.
To protect the keyboard from unauthorized use the operator can LOG the keyboard off the System.
When the keyboard is in this state the display will show -
LOGGEDOFFPLEASEENTERPASSWORD
INFO The password can be alphanumeric and up to TEN Characters.
STEP 1 Type in the PASSWORD for the User Level you require access to.
INFO Use the SHIFT key to shift between the Alpha and Numeric Keys. A capital ‘A’ will
appear on the display whenever the numeric keypad is shifted to select alpha keys.
STEP 2 Press the ENT Key
INFO The Display will then either show ACCESS DENIED if the Password was incorrect or USER
LEVELifAccess to the User Level when the Password is correct.

MEYERTECH LIMITED ISSUE 09
2.3 MODE SELECTION
Once Logged On the display will show SELECTMODE
LOGOFF
STEP 1 Press the MODE key to cycle through the Modes available for this USER LEVEL.
INFO In sequence the display will show for example LOGOFF
CLASIKMODE
VCRMODE
STEP 2 Press ENT to select the Mode required.
3. CLASIK MODE
3.1 CLASIK MODE FACILITIES
MONITOR SELECTION - 1 - 64
CAMERA SELECTION - 0 - 512
GLOBAL - HOME - AUX1 - WIPE - IRIS AUTO - LAMP
PRESETS - HOME - 1 - 16
PATROL - ORDERED - RANDOM
CAMERA CONTROL - PAN & TILT - ZOOM, FOCUS, IRIS
- IRIS AUTO / MANUAL - AUX1, AUX2, LAMP
- PWI, WASH, WIPE
SALVO SEQUENCING - 1- 64 MONITORS 16 SEQUENCE PATTERNS STEP-BACK -STEP-
FORWARD PAUSE
When the Keyboard is in CLASIK MODE the display will show CLASIKMONITOR-n
MODECAMERA-n
Page 7http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 8 http://www.meyertech.co.uk MAN-007
3.2 SELECTING A CAMERA
STEP 1 Using the Numeric Keypad enter the digits of the Camera Number to be selected.
INFO Each Digit entered will be displayed adjacent to CAMERA.
STEP2 Press the ENT Key.
INFO The display will then either retain the camera entered indicating a valid entry or show
CAMERA-ERROR or CAMERA-DENIED
To select another Camera repeat process from Step 1.
3.3 SELECTING A MONITOR
STEP 1 Press the MON key so the display shows MONITOR
STEP 2 Enter a monitor number using the Alpha Numeric Keypad.
INFO Each digit entered will be displayed adjacent to MONITOR.
STEP 3 Press the ENT Key
INFO The display will then either retain the Monitor entered indicating a valid entry or show
MONITOR-ERROR
or
MONITOR-DENIED
3.4 CAMERA CONTROL
The Camera shown on the display will always be the Camera under Control. If you require to control
a different Camera refer to section 3-2 Selecting a Camera.
Control of the Camera shown on the display is automatically achieved (assuming no other keyboard
with a higher or equal priority is already controlling the camera) when either the Pan & Tilt JOYSTICK
or Zoom & Focus JOYSTICK are moved or when either of the following keys are pressed -WASH -
AUX2 - PWI - PTZ.
To indicate control has been achieved the display will show PTZ
Otherwise the display will show CONTROL DENIED indicating the camera is currently under the control of
another keyboard.

MEYERTECH LIMITED ISSUE 09
3.5 RELEASING CAMERA CONTROL
The PTZ key when pressed will release control of the Camera, (so other keyboards can access it)
without having to select another Camera.
The second function of the PTZ key is to take control of a Camera without having to use the
JOYSTICKS etc.
Control of the Camera is also automatically released when either a new monitor or camera selection
mode, GLOBAL, PRESET or PATROL are selected.
3.6 SALVO SEQUENCE
Any Video Matrix monitor can be placed into SALVO Sequence Mode to display a sequence pattern
of cameras. Camera pictures are Salvo switched to maintain framing between patterns. When one or
more monitors have been assigned to run sequence patterns the STEP FORWARD - STEP BACK
and PAUSE keys can be used to control the SALVO switching.
STEP-BACK Each time the STEP BACK key is pressed all patterns are stepped back one
frame to display the previous camera picture.
STEP-FORWARD Each time the STEP FORWARD key is pressed all patterns are stepped
forward one frame to display the next camera picture in the pattern.
PAUSE Whilst the PAUSE key is held down all patterns will be displaying the current
camera pictures i.e. the salvo dwell time is temporarily suspended.
3.7 PLACING A MONITOR INTO SEQUENCE MODE
STEP 1 Press the SALVO key so the display shows CAMERA-P
STEP 2 Enter a PATTERN number using the Numeric Keypad in the
range 1 - 16
INFO Each digit entered will be displayed adjacent to CAMERA -P3
STEP 3 Press the ENT Key
INFO The display will then either retain the Pattern entered, indicating a valid entry, or show
CAMERA-Error and revert back to the current camera selected.
Page 9http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 10 http://www.meyertech.co.uk MAN-007
3.8 GLOBAL FACILITY
The GLOBAL facility allows a number of camera functions to be activated on all cameras in the
system with a single keystroke. The global facility can be used with the following camera control
facilities.
WIPE - All camera wipers will be switched on or off
LAMP - All camera lamps will be switched on or off
AUX1 - All camera auxiliary 1 outputs will be switched on or off
IRIS - All cameras will revert to Auto-Iris
HOME - All cameras will return to their Home position
STEP 1 Press the GLOBAL key so the display shows GLOBAL
STEP 2 Press one of the above listed function keys
INFO Cameras currently under control from another keyboard will not have the function
activated.
3.9 PRESET FACILITY
The PRESET facility allows camera presets to be recalled in the range 1 - 16. HOME is a special
preset facility which has its own dedicated key.
STEP 1 Press the PRESET key so the display shows PRESET
STEP 2 Enter a PRESET number using the Numeric Keypad in the range 1 - 16
INFO Each digit entered will be displayed adjacent to PRESET -1
STEP 3 Press the ENT Key
3.10 PATROL FACILITY
The PATROL facility allows a camera patrol to be recalled in the range 1 - 2. The camera will
automatically patrol a number of presets on either a Random or Ordered basis.
PATROL 1 - RANDOM Patrol recalls presets randomly and dwells at each preset position for
random period of time up to 15 minutes.
PATROL 2 - ORDERED Patrol recalls presets in a ordered manner dwelling at each preset for a
pre-defined period of time.
STEP 1 Press the PATROL key so the display shows PATROL
STEP 2 Using the Numeric Keypad Press 1to select a Random patrol 2to select an Ordered
patrol.
INFO A camera will continue to Patrol until it receives any valid control command.

MEYERTECH LIMITED ISSUE 09
3.11 LATCHED CAMERA FUNCTIONS
Camera control keys are provided for the following camera latched functions
WIPE LAMP AUX1 IRIS AUTO-MANUAL
STEP 1 Press the function key you require or select camera control by first pressing the PTZ
key and then select the latched function you require.
Whenever camera control is selected the display will show any camera latched
functions switched on.
WIPER LAMP A1 MAN
INFO Camera Latched functions can be selected without having first to attain control of the
camera.
3.11.1 FUNCTION TIMEOUT OVERIDE
The lamp and manual iris controls have a timeout function, controlled by the video matrix, which can
be overridden by the 007 keyboard. The function keys F1 and F2 are used for this purpose.
After activating the lamp or switching to manual Iris from the keyboard, the timer if enabled is started.
To cancel the Lamp timer, press F1 after the Lamp key.
To cancel the Iris timer, press F2 after the Iris manual key.
3.12 ZONAL SWITCHING
The Zonal Switching facility is a powerful feature capable of switching eight cameras to eight monitors
with a single keystroke. Eight ZONES can be configured per system keyboard (see section 5-10)
providing an overall Zonal Switching capability for each keyboard of sixty-four cameras to sixty-four
monitors.
Practical applications for Zonal Switching are endless but here are a few that we know have been
successfully implemented by our customers.
Using Zonal Switching to switch between floors of Car Parks and Department Stores.
Using Zonal Switching to route cameras to Quad Screen splitters and Multiplexers.
Using Zonal Switching to route S-VHS Y/C signals to VCR’s.
A typical application would involve a monitor wall and an operator control monitor. The operator would
select and operate cameras displayed on the control monitor. Zonal Switching would take place on the
monitor wall with the operator being able to view up to sixty-four cameras with just eight keystrokes.
If a particular picture on the monitor wall demanded closer inspection it would be transferred to the
operators monitor for instant control access by simply entering the camera number.
Page 11http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 12 http://www.meyertech.co.uk MAN-007
3.12.1 SELECTING ZONES
Zones are selected via the dedicated Zone Keys Z1M - Z8M. e.g. pressing Z4M would select Zone 4.
Confirmation of which Zone has been selected will be displayed on the LCD for approximately two
seconds.
E.g.ZONE4
4. SITE MODE
4.1 SITE MODE FACILITIES
SITE SELECTION - 0 - 255
MONITOR SELECTION - 1 - 64
CAMERA SELECTION - 0 - 512
GLOBAL - HOME - AUX1 - WIPE - IRIS AUTO - LAMP
PRESETS - HOME - 1 - 16
PATROL - ORDERED - RANDOM
CAMERA CONTROL - PAN & TILT - ZOOM, FOCUS, IRIS
- IRIS AUTO / MANUAL - AUX1, AUX2, LAMP
- PWI, WASH, WIPE
When the Keyboard is in SITE MODE the display will show SITE MONITOR-n
nCCAMERA-n
All Facilities operate as in clasik mode with the exception of those covered in the following sections.
4.2 SELECTING A SITE
STEP 1 Press the Site Key labeled as DEC / Record. The current site number will be cleared.
STEP 2 Using the Numeric Keypad enter the digits of the Site Number to be selected.
INFO Each Digit entered will be displayed below the word SITE.
STEP3 Press the ENT Key.

MEYERTECH LIMITED ISSUE 09
INFO A Trunk will then be automatically selected and displayed on the current monitor. The
display next to the site number will update to show the status of the selected trunk as
follows:
C – Control, operator has control of the trunk
D – Denied, operator has no control of the trunk but can view what is on it, or the
site-monitor combination is invalid
To select another Site repeat process from Step 1.
NOTE: To select the local Site, select site 0.
4.3 SELECTING A TRUNK
When selection of a site is made as described above, the first unused trunk is automatically selected
and displayed.
If all trunks are in use, the first available trunk is selected and the status shows Denied.
A different trunk can then be manually selected, or control taken of a used trunk, with the following
procedure.
STEP 1 Press the Trunk Key labeled as ENC / Play.
INFO If the current trunk was denied a +is displayed next to the status to indicate that that
the operator has manually accepted the trunk selection, and therefore may take
control of it.
Otherwise, the next trunk is selected and displayed on the current monitor. The status
of the trunk will update to reflect it’s usage.
To select another Trunk repeat Step 1. The selection will cycle through the available trunks.
4.4 SELECTING A CAMERA
STEP 1 Using the Numeric Keypad enter the digits of the Camera Number to be selected.
INFO Each Digit entered will be displayed adjacent to CAMERA.
STEP2 Press the ENT Key.
INFO The display will then either retain the camera entered indicating a valid entry or show
CAMERA-ERROR or CAMERA–DENIED
If the current trunk is denied and has not been manually selected (indicated by a +
next to the status) the switch will be denied.
To select another Camera repeat process from Step 1.
Page 13http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 14 http://www.meyertech.co.uk MAN-007
4.5 SELECTING A MONITOR
As in classic mode. The site number and trunk status is updated as well as the camera number.
5. PCI MODE
5.1 PCI MODE FACILITIES
CAMERA CONTROL - PAN & TILT
- ZOOM FOCUS IRIS
- IRIS AUTO/MANUAL - AUX1 - AUX2 - LAMP - PWI -
WASH - WIPE
PCI MODE (PC Interactive Mode) allows the Keyboard to function interactively with a PC.
Camera selections are made via the PC GUI with the last camera selected being automatically
assigned to the keyboard for Camera Control.
6. SUPERVISOR LEVEL
6.1 SUPERVISOR LEVEL FEATURES
The SUPERVISOR LEVEL is a system management level provided to configure keyboard and system
parameters.
The system cannot be operated in the normal manner associated with the three USER LEVELS.
Once logged onto the SUPERVISOR LEVEL the display will show
SUPERVISOR CONFIGURATION
LEVEL ESCTOLOGOFF
To view the configuration options available press the MODE key - with each press the display will
show -

MEYERTECH LIMITED ISSUE 09
ESCTOLOGOFF ZVRCONFIG
PASSWORDS ZVMCONFIG
MODEACCESS CAMERACONFIG
KEYBOARDSET-UP FEATUREACCESS
6.2 SELECTING AN OPTION
STEP 1 Press the MODE key until the option is displayed
STEP 2 Press the ENT key
6.3 PASSWORDS
The display will show SUPERVISOR PASSWORDS
LEVEL ESCTOEXIT
Use the MODE key to cycle through each users password - with each key press the display will show
SUPERVISOR PASSWORDS USERLEVEL1
LEVEL USER1
SUPERVISOR PASSWORDS USERLEVEL2
LEVEL USER2
SUPERVISOR PASSWORDS USERLEVEL3
LEVEL USER3
SUPERVISOR PASSWORDS SupervisorLevel
LEVEL SUPERUSER
6.3.1 CHANGING A PASSWORD
STEP 1 Press the MODE key until the password you wish to change is displayed
STEP 2 Press the PROG key. The display will erase the current password
STEP 3 Enter the new password (10 - characters maximum) using the alphanumeric keys
INFO To enter a numeric remember to press the SHIFT key first
STEP 4 Press the ENT key to save the new password
Page 15http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 16 http://www.meyertech.co.uk MAN-007
INFO Use the DEL key to backspace incorrect entries
STEP 5 Press the ESC to exit PASSWORDS
6.4 MODE ACCESS
MODE ACCESS configuration limits the modes available to each USER LEVEL thereby allowing each
user to have a different class of service. The display will show -
SUPERVISOR MODEACCESS
LEVEL ESCTOEXIT
The first thing we have to do is select the USER LEVEL whose MODE ACCESS we wish to configure
STEP 1 To select the desired USER LEVEL press the MODE key to cycle through the three
USER LEVELS
STEP 2 When the required USER LEVEL is displayed press the ENT key the display will
show
SUPERVISOR MODEACCESS USERLEVEL1
LEVEL ESCTOEXIT
STEP 3 Press the MODE key to cycle through each MODE category. The display will show
each category and current access status for the USER LEVEL selected
SUPERVISOR MODEACCESS USERLEVEL1
LEVEL CLASIK GRANTACCESS
INFO The display may also show that the MODE will be available as a future software
release by showing
SUPERVISOR MODEACCESS USERLEVEL1
LEVEL ZONEVU FUTUREFEATURE
STEP 4 To change the access status for a particular category press the PROG key the
display will show
SUPERVISOR MODEACCESS USERLEVEL1
LEVEL CLASIK DENYACCESS
INFO Each press of the PROG key will toggle the status between DENY and GRANT
STEP 5 Press the ESC key to exit MODE ACCESS
6.5 KEYBOARD SET-UP
KEYBOARD SET-UP allows the keyboard to be configured for particular system requirements.
Camera and Monitor access, Zonal Switching can be programmed along with Keyboard Engineering
facilities.
The display will show
SUPERVISOR KEYBOARDSET-UP
LEVEL ESCTOEXIT

MEYERTECH LIMITED ISSUE 09
STEP 1 Press the MODE key until the required option is displayed. With each press the
display will show -
ESCTOLOGOFF MONITORS ENGINEERING
CAMERAS ZONALSWITCHING
STEP 2 Press the ENT key
6.5.1 KEYBOARD CAMERA ACCESS
From the CAMERA menu we can enable and disable access to VIDEO and CONTROL for any
system camera.
The display will show
SUPERVISOR KEYBOARDSET-UP CAMERA-1
LEVEL ESCTOEXIT VIDEO-ON
STEP 1 Press the MODE key to cycle through the camera options
VIDEO-ON
CONTROL-ON
STEP 2 Use the VCR REW and FF keys to cycle through the system cameras
STEP 3 Use the PROG key to Enable or Disable the facility
6.5.2 KEYBOARD MONITOR ACCESS
From the MONITOR menu we can enable and disable access to VIDEO and SALVO and also assign
MONITOR numbers associated with this keyboard to specific video outputs on the VIDEO MATRIX for
any keyboard monitor.
The display will show
SUPERVISOR KEYBOARDSET-UP MONITOR-1
LEVEL ESCTOEXIT VIDEO-ON
STEP 1 Press the MODE key to cycle through the monitor options
VIDEO-ON
SALVO-ON
VOPXR-1
STEP 2 Use the VCR REW and FF keys to cycle through the keyboard monitors
STEP 3 Use the PROG key to Enable or Disable the facility.
Page 17http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 18 http://www.meyertech.co.uk MAN-007
6.5.3 KEYBOARD ENGINEERING FACILITIES
From the ENGINEER menu we set the keyboard MAC, re-program the keyboards MIC and set the
keyboards camera control PRIORITY.
The display will show
SUPERVISOR KEYBOARDSET-UP MAC
LEVEL ESCTOEXIT 01
STEP 1 Press the MODE key to cycle through the engineer options
MAC KBDPRIORITY BaudRate Networktype
1 1 9600 ZVM
STEP 2 To edit an option press the PROG key and then using the numeric
keypad enter the new assignment e.g.
FOR MAC Enter a number in the range 01 to 16
INFO If the number is less than 10 the leading zero MUST be entered.
INFO Not all ZoneVu controllers support 16 keyboards. Therefore the MAC must be set
accordingly.
FOR KBD PRIORITY Enter a number in the range 1 to 9.9
being the highest priority.
6.5.4 ZONE SETUP
Zone Set-up allows each of the eight Zones available to be configured with monitor and camera
numbers. Each Zone can be SIZEd independently in the range 2 - 8. Up to eight Monitor numbers in
the range 1 - 64 and camera numbers in the range 0 - 512 can then be entered for each Zone.
Camera 0 will produce a blank monitor.
After selecting ZONAL SWITCHING from the KEYBOARD SET-UP Menu the display will show:
SUPERVISOR KEYBOARDSET-UP ZONE-1
LEVEL ESCTOEXIT SIZE -4
STEP 1 Select the ZONE to Configure using PIP and ACT Keys.
STEP 2 Set the SIZE of the Zone in the range 2 - 8 using the numeric keypad.
INFO This effectively sets the number of Monitors that will be used when the ZONAL
SWITCH is selected.
STEP 3 Press the ENT key. The display will show -
SUPERVISOR ZONE-1 MONITOR-1 MC1
LEVEL SIZE-4 CAMERA-1
INFO MC1 displayed in the top right hand corner of the LCD tells your location within the
ZONE currently being configured i.e. MC1 - MC8.
STEP 4 Use the PIP and ACT keys to set the location within the ZONE.

MEYERTECH LIMITED ISSUE 09
STEP 5 To enter a Monitor Press the MON key and use the numeric keypad to enter a number
in the range 1 - 64 followed by the ENT key.
STEP 6 To enter a Camera use the numeric keypad to enter a number in the range 0 - 512
followed by the ENT key.
STEP 7 Repeat STEPS 4 - 6 to configure an entire ZONE. Repeat STEPS 1 - 3 to select
another ZONE.
INFO Monitors and Cameras entered in locations above the ZONE SIZE will be ignored
when the ZONE is selected in CLASIK MODE.
INFO To EXIT ZONE CONFIGURATION press the ESC key.
6.6 FEATURE ACCESS
FEATURE ACCESS configuration enables and disables a USER LEVELS to the following keyboard
features
GLOBAL PRESETS PATROL
HOME ALARMS ZONAL SWITCHING
The display will show
SUPERVISOR FEATUREACCESS
LEVEL ESCTOEXIT
The first thing we have to do is select the USER LEVEL whose FEATURE ACCESS we wish to
configure
STEP 1 To select the desired USER LEVEL press the MODE key to cycle through the three
USER LEVELS
STEP 2 When the required USER LEVEL is displayed press the ENT key the display will
show
SUPERVISOR FEATUREACCESS USERLEVEL1
LEVEL ESCTOEXIT
STEP 3 Press the MODE key to cycle through each MODE category. The display will show
each category and current access status for the USER LEVEL selected
SUPERVISOR MODEACCESS USERLEVEL1
LEVEL GLOBAL GRANTACCESS
STEP 4 To change the access status for a particular category press the PROG key the display
will show
SUPERVISOR MODEACCESS USERLEVEL1
LEVEL GLOBAL DENYACCESS
INFO Each press of the PROG key will toggle the status between DENY and GRANT
STEP 5 Press the ESC key to exit MODE ACCESS
Page 19http://www.meyertech.co.ukMAN-007

MEYERTECH LIMITED ISSUE 09
Page 20 http://www.meyertech.co.uk MAN-007
6.7 ZVR CONFIGURATION
ZVR CONFIG allows camera receivers to be configured from the comfort of the keyboard by utilising
the camera receiver OSD (On Screen Display)
The display will show
SUPERVISOR CONFIGURATION
LEVEL ZVRCONFIG
STEP 1 Press the ENT key the display will show
SUPERVISOR 510CONFIG MONITOR-1
LEVEL ESCTOEXIT CAMERA-1
STEP 2 Select the camera you want to configure using the numeric keypad and pressing the
ENT key.
STEP 3 Press the MODE key. The display will change to
SUPERVISOR 510CONFIG MONITOR-1
LEVEL PROGTOSELECT CAMERA-1
STEP 4 Press the PROG key to select the type of receiver: ZVR-510, ZVR-530, or ZVR-500
STEP 5 Press the MODE key. The display will change to
SUPERVISOR 530CONFIG MONITOR-1
LEVEL PROGTOCONFIG CAMERA-1
STEP 6 Press the PROG key to access the camera receiver OSD. The display will show
ACCESSGRANTED and then ZVRTALKMODE
STEP 7-8 The operation of the menus varies according to the receiver type.
ZVR-510 / 500
STEP 7 Follow the OSD Menus to configure the camera receiver. Select fields by pressing the
alphanumeric key corresponding to the capitalised letter in the field name, and
pressing Enter, or move between fields using the Pan/Tilt joystick and then pressing
Enter. Once a data field is selected, the Space key toggles its value, or alpanumeric
data can be entered directly. The Shift key toggles between alpha and numeric
modes and the DEC key between upper and lowercase text.
STEP 8 When you have completed configuring the camera receiver exit all menus until the
Main menu is displayed. Select either Save changes or Abandon changes, and press
Enter. Now press the ESC key to exit ZVR CONFIG.
INFO Use the joysticks to position the camera head when requested to do so by the menu -
this will be indicated by the flashing word HOME.
ZVR-530
STEP 7 Follow the OSD Menus to configure the camera receiver.
The currently selected option is shown in flashing text: Use UP and DOWN to move
the selection, and press SELECT to choose the current selection.